  OMC elog, Page 13 of 13  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  67   Tue Mar 5 19:37:00 2013 ZachOpticsCharacterizationeLIGO OMC visibility vs. power measurement detailsEDIT (ZK): Koji points out that (1 -
Ti) should really be the non-resonant reflectivity
of the aligned cavity, which is much closer
 eOMC_visibility_3_4_13.png 
  68   Wed Mar 6 23:24:58 2013 ZachOpticsCharacterizationeLIGO OMC visibility vs. power measurement detailsI found that, in fact, I had lowered
the modulation depth since when I measured
it to be 0.45 rads --> Psb = 0.1.
 TEK00005.PNGTEK00007.PNGeOMC_visibility_3_4_13.pngeOMC_AMTF_vs_power_3_6_13.png 
  107   Wed Apr 10 00:40:30 2013 ZachOpticsConfigurationfauxMC locked[Koji, Zach]
 fauxMC_labeled.jpg 
  362   Thu May 16 12:41:28 2019 ChubGeneralGeneralfire pillow found on optics tableThat is an expanding fire pillow, also
known as firebrick.  It is used to create
a fire block where holes in fire-rated walls
  
  608   Thu Aug 17 07:57:12 2023 Camille MakaremOpticsGeneralmode-matching in the cavity[Camille, Thejas, Koji]
16 August 2023
  
  606   Mon Aug 14 14:13:34 2023 Camille MakaremOpticsGeneralmode-mismatch in the cavityFor Set 1 of the data in https://nodus.ligo.caltech.edu:8081/OMC_Lab/604,

VREFL(unlocked) = 3.226V
VREFL(locked) = 0.13V
  
  607   Tue Aug 15 16:15:13 2023 Camille MakaremOpticsGeneralnew power measurements (after cleaning)[Camille, Thejas, Masayuki]

This afternoon we finished the realignment
 REFL_CCD.PNGPowerBudgetAnalysis.PNGipad_notes.PNGSpotPositions.PNG 
  592   Mon Aug 7 07:40:33 2023 Camille MakaremOpticsGeneraloptimizing reflected signal[Camille, Thejas] 4 August 2023

-REFL PD signal (unlocked): 3.5V
  
  593   Mon Aug 7 08:37:59 2023 KojiOpticsGeneraloptimizing reflected signalWith the current level of the mode
matching, the spot positions can be optimized.
I'd work on it first as the mirror RoC
  
  594   Mon Aug 7 08:51:56 2023 Camille MakaremOpticsGeneraloptimizing reflected signalWe will plan to look at the reflection
CCD image this afternoon.

  
  603   Thu Aug 10 12:33:42 2023 Camille MakaremOpticsGeneraloptimizing the cavity post-cleaning[Camille, Thejas]

This morning, we continued the efforts
 REFL_CCD.PNGCM1_Ap16.pngCM2_Ap8.pngFM1_Ap16.pngFM2_Ap8.png 
  591   Mon Aug 7 07:36:09 2023 Camille MakaremGeneralGeneralparticle count[Camille, Thejas]

We lowered the setting to MEDIUM on
  
  585   Thu Aug 3 07:22:19 2023 Camille MakaremGeneralGeneralparticle count and cavity optimization/alignmentYesterday, we measured the particle count
in the enclosure to ensure that the lower
setting on one of the HEPAs is still acceptable.
  
  582   Mon Jul 31 13:19:14 2023 Camille MakaremGeneralGeneralplans for this week 31 July 2023Plans for this week:
1) Verify electronics setup for cavity
locking.
 4ae4ed99-007e-4246-85b6-fadccc5ba19d.mp4 
  604   Fri Aug 11 10:42:05 2023 Camille MakaremOpticsCharacterizationpower budget measurements[Camille, Thejas]
10 August 2023
 1000006624.jpgPowerMeasurments_10Aug2023.PNG 
  609   Thu Aug 17 09:06:51 2023 Camille MakaremOpticsGeneralrealignment of beam path through mode-matching lenses[Camille, Thejas]
16 August 2023
 irises.PNG 
  583   Tue Aug 1 11:04:13 2023 Camille MakaremGeneralGeneralreoptimizing cavity alignment before locking[Camille, Thejas]
We rechecked the alignment this morning
and re-optimized the resonance a bit. There
  
  598   Tue Aug 8 07:39:17 2023 Camille MakaremOpticsGeneralsteering the beam spot on the curved mirrors[Camille, Thejas]
7 August 2023
 CM1_initial.jpgCM2_initial.jpgCM1_AfterAdjustment.jpgCM2_AfterAdjustment.jpg 
  600   Tue Aug 8 10:42:11 2023 ThejasOpticsGeneralsteering the beam spot on the curved mirrorsThe spots look quite bright on the CMs,
we need to move the spots towards the center
of the mirorrs to avoid scatter points.
  
  601   Wed Aug 9 07:47:21 2023 Camille, ThejasOpticsGeneralsteering the beam spot on the curved mirrors[Camille, Thejas, Masayuki]
8 August 2023
 7x 
  527   Mon Apr 24 15:29:48 2023 Camille MakaremOptics summary of zygo setupsSummary of Zygo setups

Initial Zygo Setup:
Our initial Zygo setup consisted of
 6x 
  454   Mon Nov 14 08:34:45 2022 CamilleOpticsCharacterizationtransmission measurements through OMC #1 (before cleaning)[Camille, Koji]

Friday, Nov 11th, 2022

Setting up OMC #1 for transmission
 PXL_20221111_200942943.jpgPXL_20221111_200957951.jpg 
  455   Mon Nov 14 09:27:13 2022 KojiOpticsCharacterizationtransmission measurements through OMC #1 (before cleaning)The measured total optical loss of the
OMC was

1st:   0.015 +/- 0.003
 OMC_Powerbudget.xlsx 