  503   Tue Mar 7 23:00:16 2023 Thejas OpticsCharacterizationOMC Lab clean upToday, Koji and I cleaned up the the lab
space and made some space on the
optical table for radius of curvature measurement
 IMG_0173-2.jpgIMG_0175-2.jpg 
  504   Wed Mar 8 17:27:51 2023 Thejas OpticsCharacterizationA+ OMC Curvature minimum of curved optics [Stephen, Thejas]

Today, a more rigorous effort was
made to re-measure the position of the optics
 image.jpeg 
  505   Fri Mar 10 10:23:08 2023 ThejasOpticsCharacterizationA+ OMC curved mirror radius of curvature OMC test set-up

Yesterday, laser beam output from
the fibre follwoing teh mode-matching lenses
 IMG_1E4662B2100B-1.jpegScreenshot_2023-03-10_at_10.49.45.pngScreenshot_2023-03-10_at_10.51.42.pngOMC_8_(dragged).pdf 
  506   Fri Mar 10 11:12:57 2023 Thejas OpticsCharacterizationA+ OMC Curvature minimum of curved optics [GariLynn, Stephen, Thejas]

Yesterday, we placed an iris (borrowed
from OMC Lab) infront of the spherical transmission
  
  507   Tue Mar 14 10:41:06 2023 Thejas OpticsCharacterizationA+ OMC curved mirror characterization[Camille, GarriLynn, Stephen, Thejas]

Folllowing the replacement of the
spherical transmission / reference mirror
 image.jpeg 
  508   Tue Mar 14 12:12:41 2023 Koji OpticsCharacterizationA+ OMC curved mirror characterizationRoC: 2.65m ! Interesting. I'll wait
for the follow-up analysis/measurements.
The RoC may be dependent on the area (diameter)
  
  509   Tue Mar 14 18:24:03 2023 Thejas OpticsCharacterizationA+ OMC Curved mirror radius of curvatureToday, I tried to measure the radius of
curvature of the curved mirror using the
input beam for the OMC test set-up. It was
 Screenshot_2023-03-14_at_18.29.56.pngScreenshot_2023-03-14_at_18.32.32.pngScreenshot_2023-03-14_at_18.33.28.png 
  510   Tue Mar 14 20:06:03 2023 Koji OpticsCharacterizationA+ OMC Curved mirror radius of curvatureIf the mirror has the RoC, it works as
a lens. And you should be able to see the
effect in the beam profile.
  
  511   Wed Mar 15 15:28:24 2023 Thejas OpticsCharacterizationA+ OMC Curved mirror radius of curvatureThanks for teh comment Koji. Yes, I did
see this effect by comparing the beam sizes
with and without the curved mirror. But the
  
  512   Wed Mar 15 17:07:35 2023 Koji OpticsCharacterizationA+ OMC Curved mirror radius of curvatureI hope you can find useful lenses from
the lens kit in the cabinet. If you need
more lenses and mounts, talk to our students
  
  513   Fri Mar 17 15:01:21 2023 Koji OpticsCharacterizationA+ OMC Curved mirror radius of curvatureThanks Koji, the lenses available in the
cabinet in the lab actually sufficed. 

  
  514   Fri Mar 24 07:38:54 2023 Camille MakaremOpticsCharacterizationROC measurements of the curved mirrors[Thejas, Camille]
21 March 2023

We made slight adjustments to the
  
  515   Fri Mar 24 07:47:37 2023 Camille MakaremOpticsCharacterizationROC measurements of the curved mirrors[Camille]
22 March 2023
Beam profile measurements were continued
 CurvedMirror_FL_measurments.PNGsn07.PNG 
  516   Tue Mar 28 11:21:27 2023 Camille MakaremOpticsCharacterizationSagitta measurements of curved mirrors[Camille, Stephen, Thejas]

Curved mirror sn02 was used to test
 CurvedMirrorSN02_SurfaceProfiles.PNG 
  517   Mon Apr 3 11:06:47 2023 Thejas OpticsCharacterizationFlat mirror flatnessData can be found in DCC document T2300050. 

 

On Friday. Camille and I measured
  
  518   Tue Apr 4 16:14:06 2023 KojiOpticsLoan / LendingC7 mirror to DownsI handed Camille the C7 mirror for the
cross-calibration of the ROC characterization
techniques.
  
  519   Wed Apr 5 22:09:30 2023 KojiFacilityGeneralHEPA Enclosure extensionChub finished the HEPA enclosure extension
project.
 20230405_120322.jpg20230405_120308.jpg20230405_120033.jpg 
  520   Tue Apr 11 16:18:25 2023 ThejasOpticsCharacterizationA+ OMC Curved mirror radius of curvatureCurved mirror radius of curvature raw data
can be found in the DCC document: T2300050

The input beam falling on the curved
 Screenshot_2023-04-11_at_16.23.18.pngScreenshot_2023-04-11_at_16.35.16_(2).pngini_beam.pdf 
  521   Thu Apr 13 07:47:28 2023 Camille MakaremOpticsCharacterizationZygo setup for curved mirror measurements[Camille, Thejas, Stephen]

We modified the Zygo setup for
measuring the sagitta of the curved mirrors.
 dist_angle_spread.PNG 
  522   Fri Apr 14 15:52:53 2023 Camille MakaremOpticsCharacterizationDetermining the curvature bottom of the curved mirrors[Camille, Thejas]

We repeated Zygo measurements (using
the same setup and method as below) for curved
 dist_angle_spread_v2.PNG 
  523   Fri Apr 14 16:36:29 2023 ThejasOpticsCharacterizationDetermining the curvature bottom of the curved mirrorsAttached here with are relevant plots.




 21x 
  524   Mon Apr 17 17:56:25 2023 Thejas OpticsCharacterizationA+ OMC Piezos wedge angle PZT dimension analyzed and characterized.
The blue dot in the images represents the
position of the cathode. The length of the
 19x 
  525   Tue Apr 18 07:59:46 2023 Madeline LesovskyGeneralGeneralTest Cure Bake - Curved Mirror Subassembly BondingThis is a test bake conducted in Air Bake
Oven A (ABO-A) held in the 40m Clean and
Bake facility. The overall objective is to
 6x 
  526   Wed Apr 19 14:28:08 2023 ThejasOpticsCharacterizationA+ OMC Curved mirror radius of curvatureRestimation of the parameters

Camille and I went back to the
lab to re-measure the beam profile follwoing
 ini_beam.pdf 
  527   Mon Apr 24 15:29:48 2023 Camille MakaremOptics summary of zygo setupsSummary of Zygo setups

Initial Zygo Setup:
Our initial Zygo setup consisted of
 6x 
  528   Wed Apr 26 13:23:00 2023 StephenOpticsCharacterizationPZT DC Response with Shadow Sensor - QPD Calibration[Stephen, Camille, Thejas, with support
from Marie, Dean, Luis]

We setup a shadow sensor! (Attachment
 qpd_dc_response_setup_image_20230425.jpgShadow_Sensor_Stage_Calibration_plot_20230426.png 
  529   Wed Apr 26 14:43:44 2023 StephenGeneralLoan / LendingBorrowed Items for PZT DC Response Shadow Sensor SetupBorrowed for PZT DC Response Shadow Sensor
Setup (see Attachment 1):


Thorlabs PDA100A Photodiode
 PXL_20230426_185227710.jpg 
  530   Fri Apr 28 13:25:40 2023 Thejas OpticsGeneralaLIGO OMC Unit-4[Camille, Koji, Thejas]

Yesterday, we cleaned the cavity
optics with first contact, aligned the input
 image.jpegPXL_20230428_010507088.png 
  531   Fri Apr 28 14:24:03 2023 Thejas OpticsCharacterizationA+ OMC Matching [Thejas, Camille, Stephen] 

Here are some notes on how
I plan to approach matching of
  
  532   Mon May 1 13:30:40 2023 StephenOpticsCharacterizationPZT DC Response with Shadow Sensor - PD Calibration[Stephen, Camille, Thejas, with support
from Luis]

Calibration reattempted
 pd_pzt_dc_response_setup_image_20230426.jpgShadow_Sensor_Stage_Calibration_plot_PD_20230427.png 
  533   Tue May 2 12:49:43 2023 StephenOpticsCharacterizationPZT DC Response with Shadow Sensor - First measurement attempt[Stephen, Camille, Thejas]

A running log of our efforts from
Monday 1 May. Data continues to be placed
  
  534   Thu May 4 11:39:19 2023 StephenOpticsCharacterizationPZT DC Response with Shadow Sensor - First measurement attemptEfforts from Tuesday through Thursday Wednesday,
02 through 04 May, are described below.

The main outcomes were:
  
  535   Thu May 4 15:12:14 2023 KojiGeneralCharacterizationOMC (004): Final Testing
FSR measurement (dip) -
done May 3, 2023
FSR
measurement (RFAM injection) - done
  
  536   Fri May 5 18:37:31 2023 StephenOpticsCharacterizationPZT DC Response with Shadow Sensor - First measurement attempt[Thejas, Camille, Stephen]

In Downs 227 on 05 May 2023

We took the following actions:
 Shadow_Sensor_Stage_Calibration_plot_PD_smaller_beam_20230505.pngupdated_setup_smaller_beam_spectrum_analyzer_20230505.jpg 
  537   Thu May 11 10:46:17 2023 Thejas GeneralCharacterizationaLIGO OMC[Thejas, Camille, Koji]

We aligned the laser beam to the
cavity and drove the OMC cavity PZTs (0 to
  
  538   Fri May 12 10:00:06 2023 Camille MakaremGeneralLoan / LendingBorrowed Items for PZT DC Response Shadow Sensor SetupThe ThorLabs MDT694B piezo driver was returned
to the OMC lab.

 PXL_20230511_201545235.jpg 
  539   Mon May 15 14:20:03 2023 Thejas OpticsCharacterizationA+ OMC ROC Herewith attached are the results
of curved mirror radius of curvature characterization. 

 
 21x 
  540   Mon May 15 14:24:41 2023 Thejas OpticsCharacterizationA+ OMC ROC Koji's mirror measurement result attached
herewith for comparison. 

 Screenshot_2023-05-15_at_14.24.02.png 
  541   Tue May 16 10:26:12 2023 KojiGeneralCharacterizationOMC (004): Final Testing
FSR measurement (dip) -
done May 3, 2023
FSR
measurement (RFAM injection) - done
  
  542   Tue May 16 13:07:11 2023 StephenOpticsCharacterizationPZT DC Response with Shadow Sensor - DC Response Qualitative Results, Batch 112 May 2023, Downs 227

Stephen, Camille, Thejas

We completed a first batch of PZT
  
  543   Fri May 19 16:09:31 2023 StephenGeneralGeneralA+ OMC Build Progress, Week of 2023.05.15A+ OMC Build efforts ongoing or completed
this week:


 PZT lead onboard
  
  544   Tue May 23 16:30:09 2023 Thejas ElectronicsCharacterizationA+ OMC Piezos LA coupling Oplev setup was built: arm length about
2 m 

As the PZT 44 was actuated with
 drive.png 
  545   Fri Jun 2 13:28:09 2023 Camille MakaremElectronics PZT op-lev measurementsThe op-lev setup was modified slightly
(picture attached). The He-Ne laser was replaced
with one with a lower divergence angle. The
 PXL_20230602_224339446.jpgPXL_20230602_224359795.jpg 
  546   Fri Jun 2 17:15:44 2023 StephenGeneralGeneralA+ OMC Build Progress, Weeks of 2023.05.22 and 2023.05.29A+ OMC Build efforts ongoing or completed
in the last two weeks:


 PZT lead onboard
  
ELOG V3.1.3-