40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  OMC elog  Not logged in ELOG logo
Entry  Mon Jul 2 11:30:22 2018, Koji, Electronics, Characterization, 3IFO EOM impedance measurement impedance_eom.pdfEOM_Z_DATA.zip
    Reply  Wed Jul 4 18:30:51 2018, Koji, Electronics, Characterization, EOM circuit models eom_models.pdfeom9.pdfeom24.pdfeom45.pdf180704_3IFO_EOM_model.zip
Message ID: 302     Entry time: Wed Jul 4 18:30:51 2018     In reply to: 298
Author: Koji 
Type: Electronics 
Category: Characterization 
Subject: EOM circuit models 

The circuit models for the 3IFO EOM (before mods) were made using LISO.
Then the modification plan was made to make it a new LLO EOM.

Impedance data, LISO model, Mathematica files are zipped and attached at the end.

Attachment 1: eom_models.pdf  371 kB  Uploaded Wed Jul 4 19:34:08 2018  | Show | Hide all | Show all
Attachment 2: eom9.pdf  66 kB  Uploaded Wed Jul 4 19:34:20 2018  | Hide | Hide all | Show all
eom9.pdf
Attachment 3: eom24.pdf  63 kB  Uploaded Wed Jul 4 19:34:20 2018  | Hide | Hide all | Show all
eom24.pdf
Attachment 4: eom45.pdf  62 kB  Uploaded Wed Jul 4 19:34:20 2018  | Hide | Hide all | Show all
eom45.pdf
Attachment 5: 180704_3IFO_EOM_model.zip  3.956 MB  Uploaded Wed Jul 4 19:34:49 2018
ELOG V3.1.3-