Subject: Spot position measurement on the diode mounts 

Remeasured the spot positions:

DCPD1: 1.50mm+0.085mm => Beam 0.084mm too high

DCPD2: 1.50mm+0.085mm => Beam 0.023mm too high

QPD1:   1.25mm+0.085mm => Beam 0.001mm too low

QPD2:   1.25mm+0.085mm => Beam 0.155mm too low
 

Attachment 1: DCPD1.png  3.621 MB  | Hide | Hide all
DCPD1.png
Attachment 2: DCPD2.png  2.953 MB  | Hide | Hide all
DCPD2.png
Attachment 3: QPD1.png  3.612 MB  Uploaded Fri May 10 11:16:38 2013  | Hide | Hide all
QPD1.png
Attachment 4: QPD2.png  2.136 MB  Uploaded Fri May 10 11:17:30 2013  | Hide | Hide all
QPD2.png