Thu Feb 26 18:47:59 2015 |
Zach | Laser | M2 ISS | 3-mm diode dark current and noise | Given that we see some excess noise in our 3-mm Laser Components diodes (IG17X3000G1i), especially with one of them, I went ahead and did a more careful measurement of both the dark currents and noise.
To make this measurement, I switched to OPA140 transimpedance amps on the M2 readout board and used a 1-M transimpedance.
Dark current
The OPA140 has a bias/offset current of 10 pA max and an offset voltage of 120 uV max, the latter which therefore limits the DC current sensitivity with this transimpedance to 0.12 nA. There is also some allowed current variation over temperature (±3 nA bias and ±1 nA offset over -40 to +125 °C), so this can add some more DC uncertainty if the lab temperature is a few degrees away from 25 °C. Plugging the outputs into the DMM without the diodes connected, I measured 0.0 mV and 0.2 mV on amps 1 and 2, respectively. This is consistent with the op amp spec.
The Laser Components spec for the dark current (at 5-V bias, where I measured it) is 20 nA typ, 100 nA max. Plugging in the diodes while keeping them in a blocked box and with the room lights off, I measured the following bias currents (output voltage divided by 1 M ):
- S/N 7842: 78.9 nA
- S/N 7843: 61.7 nA
- S/N 7844: 43.8 nA
- S/N 7845: > 200 nA (started below 100 nA, increased continuously while energized---see below)
The first 3 diodes are within the max spec, while 7845 seems to be exhibiting some catastrophic failure mode where the dark current is avalanching whenever the bias is engaged. Below is a plot of the measured amplifier output after a turn-on of this diode, with one of a healthy diode for comparison to the right. This was taken in the middle of the testing, and the last measurement of the current before this turn-on was around 140 nA. As you can see, there is an initial slew (not inconsistent with the timescale of the bias turn-on), followed by a slow but monotonic increase of the dark current over time. When this was repeated, the initial slew brought the current again to the last-known highest level.

So, as you can see, S/N 7845 is clearly broken. Maybe we can get a replacement
Noise
I used the same transimpedance amp setup to measure the noise. All diodes show spectactularly higher noise than the advertised level of 3.2 x 10-14 W/rtHz NEP (~3 x 10-14 A/rtHz), with a 1/f characteristic that, if extrapolated, would not intercept the quoted spec until ~1 MHz. A frequency for this spec is not mentioned on the datasheet. In all cases, the circuit was allowed to equilibrate for a few minutes before a measurement was made. The spectra below were found to be stationary, with the exception of occasional glitches.
The readout noise is limited from several 100 mHz up to near 1 kHz by the Johnson noise of the 1-M transimpedance resistor, above which there is some noise peaking centered around 40 kHz that is not inconsistent with other measurements I have made with this op amp in very-high-impedance environments (c.f., 40m:8151).

What gives?
Quote: |
IF the DC dark current is out of spec, we might be able to get a replacement. Might be specs on the website. I think Frank had a Keithley instrument to measure dark currents that are low - probably in his diode destruction elogs or DCC docs.
|
|
1211
|
Wed Feb 25 04:29:49 2015 |
Zach | DailyProgress | SiFi - ringdown | Taiwan cantilever has higher Q, going for cryo cycle now | [Nic, Zach]
Nic got a Glasgow-style cantilever from a group in Taiwan, and a quick test in the rapid cycle chamber showed that it had pretty low loss, so we are running it in the cryostat now. As a reminder, these are the rough dimensions of this style cantilever:

Below is a photo of the box it came in, showing the actual 92-um thickness of this sample, as well as a shot of it in the vacuum chamber. For some reason, this particular sample's clamping tab did not fit in the groove that Nic had built into the clamping block for the other Glasgow cantilevers, so I had to mount it to the side against the flat faces of the clamp (as I've been doing with our larger samples).

This evening, we transferred it over to the cryostat and restored all the electrical connections for what will hopefully be a fruitful cryo run. Here is a ringdown of the fundamental mode (~106 Hz) at room temperature:

The measured decay time of 41 seconds corresponds to a Q of around 14,000, which is about as good as we expect at room temperature. This sample is probably better than our other ones for at least 2 reasons:
- It is made from a better-quality (FZ) wafer, and
- It has been manufactured monolithically with a thicker clamping tab, which our modeling suggests is a very effective way to evade clamping losses by keeping strain energy within the silicon.
Given that we didn't see much improvement at all with our other samples when going to low temperature, I believe (2) is by far the biggest effect. The Glasgow wafers only have the clamp-region thickness extended to one side, which is modelled to be worse than if you go both ways, but it is still much better than we can do with our discrete sandwiching.
I filled the LN2 reservoir and the volume is cooling overnight. I did some rough ringdowns at a point when the steel block was registering around 160 K and found greatly improved Qs already (approaching and perhaps exceeding 105). We will continue to make measurements tomorrow. |
1210
|
Tue Feb 24 05:17:04 2015 |
Zach | DailyProgress | M2 ISS | First real M2 test | Tonight I succeeded in using the M2 ISS readout board and the 3-mm diodes to do some real intensity stabilization using the SiFi test setup.
First, I built a foam box to use as a temporary enclosure for the PMC and diodes until we get our real box finished:

There are holes for the input and REFL beams, and the diodes are held with makeshift mounts that clamp down on the sockets. Clearly, these aren't as stiff or stable as what we're having built, but they do the job for now. There is a steering mirror before the 50/50 BS so that the position on each diode can be adjusted separately with ease.
I didn't want to open the Chachi ISS box can of worms yet, so I just built my own temporary breadboard circuit. I had done some preliminary SR560 locking, so I knew roughly what I wanted, and I measured the modulator -> PD transfer function again today and verified that it was flat well above 100 kHz. I made a 2-stage pole/zero-style circuit, with a double (removable) pole at 300 Hz and a zero at 10 kHz to bring phase back to -90° around the target UGF of 100 kHz. It looks like this:

I wanted to DC couple, so I came up with an idea to pick off the stable 5-V bias supply from the M2 board and sum it with the (negative) output of the in-loop PD in the first stage of the servo. I had some current-related issues with the summer at first, but these went away when I increased the input resistors a bit (n.b., to fix the gain I had to change some other components, and as a result the controller TF is actually slightly different than shown above, but not much).
Hooking it up, it locked right away with the expected UGF of near 100 kHz (not yet measured, but inferred from the transfer functions and spectra). Here is the stabilization result:

As you can see, the out-of-loop signal is stabilized to the shot noise level (which is higher than the bare shot noise for half the beam due to the well-understood correlated noise imprinted by the loop) from about 5 kHz down to just below 100 Hz. Below this, there is clearly some differential environmental noise between the PDs. I did some beam scanning to try and minimize with some success, but not much. I'm not sure what the coherence below 20 Hz indicates---the in-loop signal is suppressed to below the measurement noise level, while the OOL signal exhibits excess differential noise, so I don't see why there should be any coherence.
In any case, this is a nice verification that:
- The M2 readout board works with real optical signals
- The intensity feedback system for the SiFi experiment works
- The 3-mm diodes (save for the one bad one---see CRYO:1207) behave nicely, at least for these relatively low powers
- The PMC -> PD scheme shows promise for our future tests with nicer hardware
|
1209
|
Mon Feb 23 19:55:08 2015 |
Koji | Laser | M2 ISS | 3-mm diode initial noise measurement | Frank had = PeterK had = It went to LHO
I wonder if it helps to use FEMTO's DLPCA-200 that I have somewhere in my lab. |
1208
|
Mon Feb 23 17:57:49 2015 |
rana | Laser | M2 ISS | 3-mm diode initial noise measurement | IF the DC dark current is out of spec, we might be able to get a replacement. Might be specs on the website. I think Frank had a Keithley instrument to measure dark currents that are low - probably in his diode destruction elogs or DCC docs. |
1207
|
Mon Feb 23 14:57:23 2015 |
Zach | Laser | M2 ISS | 3-mm diode initial noise measurement | I was preparing to do an initial test of the M2 ISS readout board with the 3-mm diodes on the SiFi test setup when I noticed some anomalously high noise on one of the diodes. So, I decided to make a more careful measurement and test all 4 diodes. I found that only one (S/N 7845) exhibits this very bad excess 1/f noise, but all four have it present at some level.
For this test, I had the transimpedance fairly high at Z = 2.7 k since I am only working with < 5 mW of power, and the diodes were completely blocked for this measurement and put in a dark box. The bias was 10 V at first, but then reduced to 5 V in an attempt to reduce the excess noise after I read on the datasheet that 10 V was an absolute maximum for some reason. I did not record the difference in noise from 10 V to 5 V, but this is a test I will likely try (though perhaps not up to 10 V anymore).
While 7845 is clearly bad, the others are probably OK for now; they are not acceptable for low-power/high-Z operation, but are likely just fine for our high-power testing since we will expect shot noise levels of >100 pA/rtHz, with SNR with respect to PD noise increasing as .

|
1206
|
Fri Feb 20 05:41:04 2015 |
Zach | DailyProgress | Laser | Simple ISS test | I wanted to do some intensity feedback testing, for two reasons:
- Just to get used to using the fiber amplitude modulators
- While I wait for the machined parts for the 1064nm M2 ISS testing on the old gyro table, I might as well use this basically perfect setup to do some initial runs with the M2 at 1550nm
So that I can have as much power as possible, I removed the fiber phase modulator and installed the amplitude modulator in its place. To generate the PDH sidebands, I simply drove into the laser bias tee with the 30 MHz oscillator signal and increased the amplitude until I got the same modulation depth as I measured with the modulator. I also had to readjust the demod phase via cable lengths, but after that the cavity locked just as before (and with an identical OLTF---not shown here). I don't claim that this locking technique is as good as using a phase modulator, in light of possible RFAM effects, but it is likely fine for intensity testing.
I also tried to increase the DC drive current of the laser, but it kept stalling after I tried to increase it above ~115 mA (the output power would increase in accordance with the plot on the datasheet, but then would suddenly crash and not return if the current was lowered until the driver output ON/OFF was cycled---not sure what gives here). So, I set it to 100 mA, where it seemed stable. The output of the laser head at this current is ~12 mW, so the max-transmission output of the amplitude modulator is about 6 mW (due to the 50% insertion loss). Adding a slight DC offset to the modulator, I reduced the output to ~92% to get some linear actuation strength for feedback.
I then tried to create an AC-coupled loop with an SR560, but had problems with stability on the low end. Eventually, I gave up and used the A-B function to subtract the measured DC level of around 4 V from the TRANS PD signal. I then put a pole at 300 Hz and scaled up the gain until I saw oscillations up near 100 kHz, and then slightly back down. Using this offset-subtracted DC-coupled loop, I was able to get solid in-loop performance, obtaining a UGF near 100 kHz and suppressing fluctuations to the dark noise level (consistent with the PDA255's noise) over a wide band.

The next step will be to use my low-noise readout optoelectronics and try out the Chachi servo.
|
1205
|
Fri Feb 20 05:22:19 2015 |
Zach | DailyProgress | Laser | Error calibration -> actuation TFs and new laser frequency noise measurement | Using the REFL PDH setup I built the other day (and that was detailed somewhat by Nic and Chris W. in CRYO:1204), I calibrated the error response so that I could make some further measurements. To refresh, this is using 30-MHz sidebands applied using one of our fiber phase modulators, sensing with a 1611 in reflection. The sideband drive was 0 dBm.
Using the sidebands as a reference, I calculated the slope at 6.4 nV/Hz:

Note that the error signal is slightly asymmetric, but there is no large offset.
With this information, I made some measurements:
Actuation transfer functions
I wanted to measure the actuation transfer functions afforded by:
- The standalone ThorLabs laser diode driver (LDC201C) that is currently used to drive the west laser
- The diode driver in the integrated ThorLabs laser controller (ITC502) that is currently used to drive the east laser
- Simply driving into the bias tee on the diode
All measurements were done with the west laser head, driving as described and reading out at the error point, then correcting for the loop gain and calibrating to Hz.

Everything is more or less as expected:
- The LDC201C only claims 3 kHz bandwidth, which is actually a bit of a stretch as usual
- The ITC502 claims 500 kHz, and this is also a stretch (there is -45° at 40 kHz), but it's not so bad for some early locking
- Directly driving into the diode works across this measurement band and likely far, far beyond
- There are some common features, prominently at low frequencies and somewhat so at higher ones that likely arise from the current -> frequency response of the diode itself
Laser frequency noise
I now have another calibrated measure of laser frequency noise, wherever it dominates over the PMC length noise. I measured the error signal, corrected for the loop gain and calibrated to Hz. For comparison, I've added the measurement using the Zurich PLL on the beat between the two free-running lasers on 12/17/2014 (see CRYO:1185), as well as the RIO spec for this laser.

As you can see, tonight's measurement agrees quite well with the earlier one upt to ~1 kHz, above which the old measurement is probably marred by the relatively low-bandwidth PLL. It seems that the PMC is quiet enough to see the laser noise throughout, and the new measurement now sits closer to the spec up to the highest available point at 10 kHz. Below ~50 Hz, we are probably seeing the well-documented excess noise from the ThorLabs driver. Everything looks as expected.
Locking via laser feedback
Relatively early in the night, after having measured the actuation transfer functions, I sucessfully locked the cavity via feedback to the laser (as opposed to the PMC PZT) for the first time. Below is a comparison of the OLTFs for a 1-kHz loop using the same servo shape (a pole at 1 Hz) using both actuation schemes.

Because of what I had hooked up at the time, I only did this with the (low-bandwidth) LDC201C, so, while the absence of a ~10-kHz resonance is clear, the phase margin is not improved at all (worsened, actually). I only report this as a milestone, and the margin afforded by the ITC502 or by directly driving via the bias tee should be far better. |
1204
|
Thu Feb 12 15:34:12 2015 |
Nic, Chris | Laser | Transfer Functions | higher bandwidth frequency readout | In order to better measure the effect of this nonlinear current to frequency modulation, we'll need to do Zach's measurement but with much higher drive frequencies. (His measurement was 1kHz).
We'd like to do a full TF of the nonlinear current amplitude modulation path to the laser frequency. There are two effects in Zach's setup that limit the bandwidth of the measurement.
First, is the modulation input of the Marconi, which only reaches 30kHz. We plan to use a mixer to do higher frequency AM of the RF carrier.
The second is the frequency readout. We potentially could PLL the two lasers together and have a pretty high bandwidth readout. or, instead we decided to add some additional PDH sidebands to the light using the fiber modulator. This was then sensed in reflection of the PMC and demodulated. We used 30MHz at 0.5Vpp into the fiber modulator.
With this setup, we were able to measure some amount of nonlinear current to frequency modulation, and when we unlocked the cavity the transfer function was reduced by at least 20dB, which rules out some other coupling path.
Next step is to set up high bandwidth AM of the 500MHz marconi output (driving the current). |
1203
|
Wed Feb 11 03:58:52 2015 |
Zach | Laser | Transfer Functions | Wipf nonlinear temperature actuation proof of principle | Nic elucidated to me today Chris W.'s idea for getting truly wideband (~500 MHz) actuation out of our diode lasers. In case the reader isn't familiar, the lasers have two parallel linear actuation pathways converting current into frequency: one from current modulating the temperature, which is the strongest effect at DC and then dies off above ~1 MHz due most likely to the thermal response, and another, weaker but much wider-band, flat pathway arising from solid state effects that did not survive the elucidating. At some frequency (around 50 MHz, I believe?), there is a crossover between these paths, but there is a differing sign, which creates a "non-minimal-phase zero", leaving the phase at -180° and making the overall system a difficult actuator to deal with at high frequencies.
As I understand it, Chris's idea involves using the full, nonlinear current-to-temperature response to effectively circumvent the direct linear response at low frequencies. This can be done, for example, by pumping a strong RF carrier current (say, around 1 GHz) into the diode, and then using amplitude modulation on this carrier to produce baseband frequency actuation from the temperature beating. By choosing the phase of the AM correctly, one can make it so this pathway (now dominant at low frequencies) results in a nicer crossover with linear pathway #2 from above.
I performed a very simple proof-of-principle test today by doing the following:
- Dither lock my temporary diagnostic PMC to one laser using the setup described in CRYO:1195.
- Set the UGF fairly low (a few 100 Hz)
- Drive the laser current with a 1-kHz sine wave, strong enough to be clearly present above the noise in the error signal. I found that 200 uVpp (= 2 uApp) gave me a nice SNR around 20.
- Using a Marconi into the SMA bias tee adapter directly on the diode, inject a fairly strong RF carrier current. I used 600 MHz at ~200 uArms, though the amplitude was determined empirically over the course of the test to see an effect.
- Engage amplitude modulation at 1 kHz and a pretty strong modulation (I chose "50%").
- (As I mentioned a couple bullets above, in reality, I removed the direct 1-kHz injection and pumped this RF-with-AM current up until I saw an effect in the error signal)
- With these two signals on, and adjusting the AM phase, I was clearly able to see modulation of the line in the error signal, indicating that the two drives were interfering as desired.
Trimming the RF amplitude and phase a bit to get a nice result, I was able to take the two spectra shown below. In the first trace, only the direct current line is present at 1 kHz. In the second one, the RF source is engaged and you can see an exact cancellation of the line in the error signal. Increasing or decreasing the RF (or audio) amplitudes led to the reemergence of the line (assuredly with 180º relative phase from one case to the other). To do the wideband actuation, one would simply make sure that the RF power is strong enough that the nonlinear path dominates.

So, it should work! We'll have to change the measurement setup to make a full transfer function showing clean actuation to very high frequencies, but it should be pretty straightforward. |
1202
|
Wed Feb 11 03:15:02 2015 |
Zach | DailyProgress | SiFi - ringdown | Only some extra damping is from wires | Following my preliminary conclusion from yesterday (CRYO:1201), I set out to confirm or deny this seeming decrease in Q for a given clamp when going from the simple vacuum chamber to the cryostat.
One potential source of extra damping I considered was the wires attached to the block for the power resistor and RTD, so, while I still had the clamp in the cryostat assembly, I just disconnected these wires and pumped down the cryostat to see if I saw an improvement. I did see an increase in Q from ~3000 to ~5500, but not to the full 7000 I saw before in the standalone chamber. So, I conclude that there is some appreciable damping added by this kapton wiring. We need to use less rigid wire for the last stretch between the coldplate-mounted strain releif and the block.
The last step was to transport the clamp back into the simple chamber and see if I could recover the Q of 7000 that I measured initially. I did, completing the circle of repeatablility. I'm not sure what else could be causing the excess damping in the cryostat.
It is a shame, because I would be very interested to see what this particular silicon sandwich clamp looks like at 120 K, but I seem to have now way of doing so without the extra losses empirically associated with putting it in the cryostat. |
1201
|
Tue Feb 10 04:37:05 2015 |
Zach | DailyProgress | SiFi - ringdown | Q consistently lower in cryostat | A lot of things happened tonight (mostly in the realm of setbacks followed by recovering frome them), but the take-home is that the measured Q of my silicon sandwich clamp seems consistently lower when measured in the cryostat, compared to in the new chamber from the gyro. Here's a rundown of what happened today/tonight:
- Before dinner, I made a first measurement on the silicon sandwich idea (cantilever sandwiched between a couple spare pieces of silicon on each side --- see CRYO:1200). This gave me the highest room-temperature Q I've measured yet at ~6800.
- After dinner, I wanted to port this to the cryostat and potentially do a cooling run. Unfortunately, to fit it in the cryo volume, I had to flip the sandwich around so that it was protruding from the clamp in the other direction (for the first run, I had it sticking out over the power resistor to avoid clamping in the region on the other side that has the groove for the Glasgow-style cantilevers, but there wasn't enough room for that orientation in the cryostat, so I had to flip back---I made it work so I didn't clamp over the groove anyhow).
- Unwittingly, I made the dumb mistake of not first testing this freshly-clamped system again in the simple chamber, and after I closed the whole cryostat again and pumped down, I measured a much lower Q (back down around 3000).
- So, I opened the cryostat again, and then spaced out and made the further mistake of still not testing this apparently bad clamp job in the simple chamber, just to verify that I got the same low Q. Instead, I went straight to cleaning all the pieces and re-clamping.
- This time, I put it into the simple chamber and immediately recorded a high Q around 7000 again.
- This is when some setbacks kicked in:
- In opening the chamber, one of the RTD wires came loose from the feedthrough.
- Not realizing that these were just press-fit sockets, I unscrewed the feedthrough to have access so I could reattach the single loose wire, only to have several others fall off.
- So, I disconnected all the wires, spent some time mapping which one went where, re-soldered some and re-kapton shieled all, then reattached all wires, bunch taped them and taped the bunch to the feedthrough so that none could easily come loose. I also took this time to resolder the ESD wire that I broke the other day.
- In moving stuff around, I accidentally tugged on the ribbon cable between the QPD and its vectorboard readout circuit, pulling a couple connections.
- So I spent some time fixing that
- Now I was ready to do science again, so I transferred the (known good) clamp from the simple chamber back into the cryostat and carefully closed it all up again.
- After seal and pumpdown, I again measured a low Q around 3000.
So, it seems that the Q is repeatably lower for a particular clamp in the cryostat vs. in the simple chamber. To be sure, I'm going to do the final step of returning the clamp back to the simple chamber tomorrow and see if I again get a higher Q.
I'm not exactly sure why this could be happening. The only mechanical differences from one chamber to the other are:
- The clamping block is screwed via holes in the PEEK base to the cold plate in the cryostat, while it is dogclamped to the breadboard in the simple chamber.
- In the cryostat, there are wires soldered to the power resistor attached to the clamping block as well as a wire-attached Pt RTD kapton-taped to it. None of this is present in the simple chamber.
I'm tempted to think that (2) could be causing some excess damping, so one thing I will try is simply not connecting these just to see if that makes the probem go away. |
1200
|
Mon Feb 9 18:49:55 2015 |
Zach | DailyProgress | SiFi - ringdown | Q ~ 6800 at room temp with Si sandwich | As I planned yesterday (CRYO:1199), I tried out a new clamp using spare pieces of broken silicon instead of sapphire washers to sandwich the cantilever (as with the last run, I used the old, stiff rectangular block clamp---the newer cylindrical one is still in the cryostat).
I didn't take a photo, but this was basically just a sandwich consisting of the cantilever (still attached to the central wafer region) as the meat and two scrap broken-off cantilevers on each side as the bread. This was all put near the center of the steel block clamp so that the clamping force was normal, and I made sure that the protruding cantilever had enough room not to be clipped by the block as it swings.
I put it in the new chamber and pumped down, and immediately measured a fairly high Q of ~6800 (ringdown tau ~ 6.4 s, while the mode frequency is ~340 Hz---slightly higher than before due to the clamping being a bit further along the cantilever).

This is the highest room-temperature Q I've yet measured, beating the ~4300 I measured after we first installed the sapphire washers on the newer cylindrical clamp (see CRYO:1191), and is within a factor of 2 of Marie's prediction in the absence of clamping loss (also shown in that post). This is also by far the cleanest ringdown I've seen: there are a few high-frequency modes present when I first deliver the impulse, but they die away and do not return. The Q also seems far less amplitude-dependent than I've noticed before. |
1199
|
Mon Feb 9 02:59:28 2015 |
Zach | Lab Infrastructure | SiFi - ringdown | New vacuum chamber for rapid room-temperature iteration | It is a little tedious waiting for a full cryo cycle to iterate on the clamp. Also, in many cases we can learn a lot from just running at room temperature, but opening and closing the cryostat to get at the experiment takes a fair bit of effort. So, tonight I repurposed one of the gyro corner chambers to serve as a rapid-iteration room-temperature testbed. I used the northeast chamber since it had the pump connection. It has 2 KF flanges (on which I have put blanks) and 2 CF (one which goes to the gauges and valve, and the other which used to have a blank that I have replaced with a window).
I set it up next to the cryostat so that we only have to move 2 mirrors to switch between setups.

Given my revelation about the energy leakage and PEEK loss last night (see CRYO:1198), I resurrected the old rectangular block clamp to try a new idea. Namely, I just tried sandwiching the silicon cantilever (the central region with the hole, that is) between two sapphire washers, and then clamping the whole sandwich using the block clamp. The block clamp also has a PEEK base, but it should have provided a much stiffer clamp than the newer, cylindrical one, and that should result in less energy getting to the base. Here is what it looked like:

I pumped the chamber down and took a quick ringdown measurement. Unfortunately, the result was a Q in the ~2000 region, similar to what it was when we first installed the sapphire washers in the newer clamp and the bottom one was sitting on the clamp's lip (see CRYO:1191). Never fear---I have a new suspect: in looking at my photos, I'm noticing that the sapphire washers are not particularly flat. This could mean that the clamp contact is some strange shape and/or that the silicon is being stressed in some strange way.

Instead of the washers, I think I'm going to try sandwiching the cantilever between some other spare pieces of silicon that we have. If I use enough pieces to make a decently thick clamping region, this should serve the same purpose that we hoped the sapphire washers would. I'll try this tomorrow.
I sealed the cryostat vacuum line so I could use the pump for the new chamber. The LN2 reservoir was empty before I did so, and the clamp was registering around 250 K when I left. In any case, I'm going to keep iterating with the new chamber, and I think we shouldn't bother with the cryostat again until we can demonstrate a Q of close 104 at room temperature. |
1198
|
Sun Feb 8 02:49:27 2015 |
Zach | DailyProgress | SiFi - ringdown | Q still low after clamp adjustments, mode cross-coupling suspected | The cantilever was fully cooled by the time I got in this afternoon. I measured some quick ringdowns by looking at the amplitude on the scope, and estimated a Q of 2-2.5 x 104. This is slightly better than what I measured the other day before improving the clamping (see CRYO:1193), but not good---still a few orders of magnitude below what we expect. I heated the system up near 120 K and found a slight reduction in Q.
Unlike before, I noticed a strange sort of sloshing of energy into a higher-frequency mode (~1350 Hz). It was hard to tell, but I got the sense that energy was being dissipated out of the fundamental mode through this higher-order one. I looked at a time-lapse spectrum of the ringdown, and it seemed to confirm this effect. If you look at the movie below (which is just about real time), you can see that the RMS of the two modes between 1-2 kHz pump up and down, while the fundamental mode around 215 Hz monotonically decreases. If you squint, it appears that the full RMS stays constant in most cases while the high-frequency modes ring up, while they all decrease together. This, coupled with the fact that everything rings down to zero if left alone, indicates to me that energy is leaking from the fundamental mode out through these others. As an order-of-magnitude estimate, the amount of energy pumped through these modes as the amplitudes increase and decrease is not inconsistent with the energy lost from the fundamental based on the observed Q.
I did some COMSOLing to try and figure out what is going on, and at first I couldn't explain it; it appeared that even the higher-frequency modes should have too little strain energy density leakage into the steel to explain the effect, especially with the sapphire spacers. In looking a little more carefully, though, I realized that we have not been careful enough in modeling our system: at the bottom of the clamp stack, there is a PEEK platform between the clamp post and the cold plate. This is there by design, to thermally insulate the clamp from the bath (for heating), but it also considerably softens the contact there.
This PEEK piece shouldn't have much of an effect on the fundamental mode, as the energy ratio for that mode is of order 10-4. The second mode at 1350 Hz is nearly as well isolated. However, for the third mode around 1800 Hz, something like 70%(!!) of the energy is expected to reside in the PEEK layer. Since PEEK has very high loss, this is not good. Here are some COMSOL screenshots, with the first 3 showing the first 3 mode shapes, and the fourth showing the (log) strain energy density for the 3rd mode. Note that this model is run at room temperature, so the eigenfrequencies are somewhat higher than in my spectra.

So, my hypothesis is that somehow energy is leaking from the (otherwise well-isolated) fundamental mode into these higher-order ones, where it is immediately lost to friction in the PEEK. One possible step is to get rid of the PEEK piece, but that doesn't address the question of why the cross-coupling exists in the first place. My intuition fails me, so I'm not sure what the right thing to do is. |
1197
|
Sat Feb 7 03:50:14 2015 |
Zach | DailyProgress | SiFi - ringdown | Electrical connections fixed, clamp adjusted, chamber repumped and cooling | I vented the chamber today to redo the clamping and investigate our wiring issues.
Clamp
Since I observed relatively low Q even at cryogenic temperatures, I assumed there was some jankiness with how we clamped the cantilever when we installed the sapphire washers. Recall that the lower part of the steel clamp has a circular lip near the center around the screw hole, and it was too wide to allow the sapphire washers to fit around it. This meant that the lower washer was only being held by this lip, and not by the full surface area of the clamp. Also, when we installed the washers, we didn't remove the smallest can around the physics package, so we were doing a bit of guesswork as to how well aligned the entire clamp stack was. This meant that there could have been some slight rubbing, for example. Here is a photo of what it looked like in profile when I did remove the can today:

You can see what I mean about the lip, and it's also clear that the stack was not very well aligned. To fix the lip problem, I found a steel washer that was just about the right thickness and drilled the center hole out wide enough that it fit around the lip. This way, the lower sapphire washer will be supported by a larger surface from below (of course, the real solution will be to either design a new clamp or get wide-enough-ID sapphire washers). The picture on the left below shows the washer around the lip.
There was also some dust and other gunk visible to the eye, so I thoroughly cleaned all parts in the stack with methanol and isopropanol. I then carefully restacked the components and reclamped (a little tighter than we did last time, as well). The final stack is shown below at right.

Wiring
I checked each connection from the feedthrough to the heater or RTD, and found that everything seemed to be in order, so there must have just been a short when we closed up last time. I wrapped some extra kapton around each connector solder joint to provide insulation and extra strain relief, and everything stayed as it should be when I resealed the chamber. I *did* accidentally break a joint on the wire for the ESD while closing up---whoops---but I decided it was more hassle to fix it than necessary for this next run. I'll resolder it when we cycle again.
The chamber is under vacuum now and I filled the reservoir with nitrogen. The clamp was at 200 K when I left around 10pm, so I'm hoping things will be calm and cool when I come in tomorrow.
|
1196
|
Fri Feb 6 05:31:43 2015 |
Zach | Laser | SiFi | Phase modulator characterization | After rebuilding the PMC setup (see CRYO:1195), I was finally able to move on to characterizing the Photline fiber-coupled phase modulators we will be using (MPX-LN-0.1 --- datasheet attached nope google it yourself). I measured a couple things:
Insertion loss
As with the amplitude modulators (see CRYO:1187), I determined this simply by measusing the power straight out of the laser, then quickly connecting each phase modulator (one at a time) between the laser and the output coupler and measuring again. As I mentioned in the linked post, this is not an exact science due to the somewhat unpredictable behavior from connector to connector. Nevertheless, one can be confident at the one-to-few-percent level.
S/N 10:
2.66 mW out / 5.00 mW in --> loss ~ 2.74 dB
S/N 2:
2.88 mW out / 5.38 mW in --> loss ~ 2.71 dB
Supposedly, we had these two units hand selected for loss < 2.5 dB (for free, after we paid for the $500 low-loss selection of the amplitude modulators), while the standard typical loss from the datasheet is closer to what we have at 2.7 dB. An extra 0.2 dB isn't going to break the bank, but it's a bit disappointing that they didn't give us what they said. Probably too late to say anything anyway...
Response
My plan was to use the modulators to pump light into RF sidebands, then use the frequency selectivity of the PMC to measure the SB power and back out the actuation strength (Vpi). I was able to do this, to a degree, but I was thwarted by an unexpected issue: the modulators and the fibers coupling to/from them appear to change the output mode emerging from the collimator. What's worse, the mode seems highly sensitive to any touching of the fiber whatsoever. This was most egregious with S/N 10, with which my new cavity coupling maxed out at 83%(!), even after slight empirical MMT tweaking. S/N 2 wasn't as nasty; I got ~91.5% with it.
Given this, my new plan was to make a quick-and-dirty measurement in the following way:
- Optimize the mode matching and record the contrast defect (17% and 8.5%, for S/N 10 and S/N 2, respectively, as mentioned above)
- Drive the modulator at a chosen RF frequency (I chose 30 MHz since this is near where we'll be using them), and determine the amplitude necessary to double the reflected power.
- The measured amplitude is associated with the modulation depth necessary to pump the same fractional power as the contrast defect out of the carrier (really, you could use any SB power level additively distinguishable from the contrast defect, but doubling it seemed the easiest thing)
- Use the bessel function to infer that modulation depth, then scale the measured amplitude up to infer Vpi.
S/N 10:
Measured amplitude to double REFL power: 0.78 Vpp --> 0.39 Vpk.
2*J1^2 = 17% --> gamma = 0.611
Vpi = 0.39 * (pi / 0.611) ~ 2.00 V
S/N 2:
Measured amplitude to double REFL power: 0.52 Vpp --> 0.26 Vpk.
2*J1^2 = 8.5% --> gamma = 0.422
Vpi = 0.26 * (pi / 0.422) ~ 1.93 V
The datasheet claims 3.5 V typical, so this seems pretty good (though the spec is only officially at 50 kHz drive). Holding the amplitudes constant, I also swept the frequency down from 30 MHz to 10 MHz, and the reflected power was stable to around 5%.
Again, this is only really a quick-and-dirty measurement. Unfortunately, the only real way to get a good measurement is to reprofile the beam again with each modulator in place. Then, the contrast defect can presumably be brought down closer to 2% or better again, and the measurement can be made more cleanly. I'm hesitant to waste time doing so, though, given the observed mode dependence on the fiber resting position.
|
1195
|
Fri Feb 6 04:46:26 2015 |
Zach | Laser | SiFi | Beam profile remeasured, test PMC aligned well and locked | I was having some issues with the beam(s) I had previously mode matched into the PMC. Apart from not having gotten great coupling to begin with, the alignment seemed to have drifted over a few days (I noticed this last week). I attributed this to 2 things: 1) the MMT I had was a pretty sensitive one, owing partly to the fact that I had to work with the beam far outside the Rayleigh zone due to the beam beat recombination being upstream, and 2) having the recombining BS in the way, I was susceptible to clipping in the output path I was using for the PMC. I don't really need the beat setup at the moment, and I can do the modulator characterization using a single laser, so I decided to rebuild the PMC test setup using a single laser.
As a first step, I simply remeasured the output beam profile of the West laser using the razor blade technique. The beam seems very circular and not astigmatic, so I only profiled in the horizontal direction. The result:

Using this, I recalculated a better MMT:
------------------------------------------------------------
Other solution:
mismatch: 0.00011786
w0x = 303.7849 um
w0y = 303.7849 um
lens 1: f = 103.2118 mm
lens 2: f = 206.4236 mm
Distances:
d1 = 6.161 cm
d2 = 14.3007 cm
d3 = 29.5383 cm
(Total distance = 50 cm)
I then installed this, aligned the PMC and was able to get ~96% coupling with little trouble. By locally optimizing the second lens, I pushed this to about 97.5%. While a bullseye was faintly evident on the card in the first case, it was very hard to tell what was reflected after the reoptimization.

I borrowed the RF electronics from the steel gyro PMC temporarily (splitter, mixer, bias tee and filters). For some reason, the 1-MHz dither I used with that PMC did not work with this one, but I was able to derive a nice error signal using a 300-kHz dither at 3 Vpp. I wanted to use the uPDH box I used to use before I had the digital servo for the gyro PMC, but I forgot that Eric Q had borrowed it for the 40m. Instead, I was actually able to lock robustly and stably with just an SR560 and a single pole at 10 Hz. The control signal stays within its output range over ~10 min+ time scales. (I didn't bother measuring the loop---all I needed for my phase modulator characterization is essentially a DC lock, and the bandwith was easily 10s-100s of Hz).
The transmission dither lock leaves the REFL port open so that I can measure the rejected sideband light pumped by the modulator as planned. |
1194
|
Fri Feb 6 04:23:20 2015 |
Zach | DailyProgress | SiFi - ringdown | No big Q increase at low temperature | I monitored the reservoir level periodically over the day and night. As of the evening, there appeared to be ~1 cm of LN2 still there. As of around 4am, it appears empty, so it should be OK to open tomorrow. I've sealed the vacuum and shut off the pump in preparation.
Quote: |
I'm going to wait for things to warm up and then vent the chamber so that we can:
- Improve the clamp
- Fix our wiring issues
|
|
1193
|
Thu Feb 5 02:04:39 2015 |
Zach | DailyProgress | SiFi - ringdown | No big Q increase at low temperature | Dmass helped me solve the Great Funnel Problem of 2015 by fashioning a foil extender to put in the tip of his metal funnel, since my glass funnel has a spout that is too narrow to get enough nitrogren through it. We spent some time yesterday afternoon filling the reservoir, after which I waited and then came back to see if it was still holding liquid. It was, so I added some more and left it overnight, and there still seemed to be some liquid by late this afternoon.
Assuming the cold volume had had enough time to reach low temperature, I made a quick ringdown measurement, only to find that the Q had only increased from ~4000 to ~8000 between room temperature and now. I think this means that the clamp integrity afforded by the sapphire washer sitting on just the lip of the steel clamp is not good.
I'm going to wait for things to warm up and then vent the chamber so that we can:
- Improve the clamp
- Fix our wiring issues
|
1192
|
Wed Jan 21 15:21:19 2015 |
Zach | Lab Infrastructure | Cryo | New LN2 dewar delivered | I ordered a new LN2 dewar and it has just arrived. Appropriately, for me, it is #305.

|
1191
|
Thu Jan 15 18:27:02 2015 |
Zach | DailyProgress | SiFi - ringdown | Sapphire washers added, ringdown setup rebuilt, higher Q measured | [Nic, Zach]
Yesterday, we opened up the small cryostat and installed the sapphire washers (SwissJewel SP-175). This is hypothesized to increase the resonator Q by reducing the strain energy leaking into the lower-Q steel clamp.
We found that the inner diameter of the washers is slightly too small to accomodate the inner lip of the lower part of the clamp. We were able to make do just by having the lower sapphire washer sitting on this lip---rather than on the full wider area of the lower clamp section---but it is not ideal.
Nevertheless, we clamped it, resealed and pumped the chamber down. As it pumped, I rebuilt the HeNe optical lever readout. When I finished, I was quickly able to tap the cryostat and see a mode ringing at almost exactly 250 Hz, which is known to be the frequency of this cantilever at room temperature. At a respectable pressure of several x 10-5 Torr, I made a quick-and-dirty ringdown measurement using a scope and a stopwatch. I estimated at roughly 2.5 seconds, giving Q ~ 2000. This was already a few times higher than Marie was able to measure at room temperature (see below).

I went down today and did an actual measurment, using the Zurich box sampling at 7 kHz as DAQ. Fitting the envelope by eye, I found a time constant closer to = 5.55 s, giving Q ~ 4300 (I don't think my stopwatch method was all that wrong yesterday, but I do think the residual gas might have been contributing at the time---the pressure is now at 10-7 Torr). This is not only much better than the previous result, but also within a factor of less than 3 of the expected result for Si, according to Marie's data. Given how cavalier we were with the clamping, I'm fairly confident that the sapphire washer idea (and therefore also the monolithic thicker-clamp idea) works as intended.

|
1190
|
Wed Jan 14 02:38:43 2015 |
Zach | Laser | SiFi | PMC set up as test cavity | To continue with the laser/modulator testing, I have added Dmass's old PMC to the temporary characterization setup. I have used the other output of the 50/50 BS that combines the two laser diode outputs, so that we can keep the beat setup intact while also being able to send either of the two beams into the PMC.

To do this, I:
- Made a cursory razor beam scan of the beam emerging from the BS
- Calculated a MMT solution to the PMC mode using some of our new lenses
- Installed the telescope and directed the beam towards the PMC
- Macropositioned the PMC by hand to rougly center it on the transmission of the single-pass beam, as measured using a power meter
- Scanned the PZT using a 0-10 V triangle from an SRS function generator, then used the diode temperature as a coarse adjustment to look for modes
- Maximized the first found mode (a horizontal HOM)
- Looked for nearby lower-order modes, then maximized them and iterated to get to TEM00
- Installed HWP upstream and then maximized visibility by rotating polarization
The coupling isn't stellar yet, at roughly ~66%, but the MMT is fairly tight and I'm sure I can improve easily. The laser and cavity are stable to well within a linewidth at high frequencies, and only drift apart over many seconds.
Some things I plan to do with this setup:
- Dither lock the PMC to the laser(s)
- Characterize the phase modulators
- Set up reflection PDH lock and feed back to lasers
- More stuff
|
1189
|
Mon Jan 12 13:35:31 2015 |
Dmass | Notes | Cavity | Cavity Parameters from Dec 2014 Labwork | The boring way:
|
Attachment 1: CavityParameters.pdf
|
|
1188
|
Mon Jan 12 13:10:08 2015 |
Dmass | Notes | Cavity | Cavity Parameters from Dec 2014 Labwork | |
1187
|
Fri Dec 19 21:37:12 2014 |
Zach | Laser | SiFi | Amplitude modulator characterization | Tonight, I did some characterization of the Photline fiber-coupled amplitude modulators we will use for our experiment (MXAN-LN-10 --- datasheet attached nope google it yourself). These are electro-optic devices that work by using an internal mach-zehnder to convert phase modulation into amplitude modulation.
The test setup for all measurements was the same. I used the exact configuration that I have been using for the beat (see CRYO:1182), but I simply blocked one laser, so that only one beam was hitting the 1811 PD. The amplitude modulators were inserted (one at a time) between the East laser and its output coupler.

Insertion loss
The first thing I did was to investigate the insertion loss of the modulators. We chose the low-loss option, which just meant that the company hand-selected modulators with loss of < 3dB (= 50% power transmission).
I didn't go crazy with precision here, because systematics with fiber coupling can easily prevent a measurement to better than a few percent (an example of this: I installed a 1-meter patch fiber between the laser and the output coupler, instead of the modulator, and I actually saw a slight increase in output power vs. the case with the laser going straight to the output coupler… go figure).
In both cases, I measured very nearly 50% reduction in power (at the top of the MZ fringe---see below) vs. the case with no modulator. So, these things have a loss very close to 3 dB, as advertised. An important thing to point out is that we will need to bias these away from maximum transmission to get a linear PM -> AM coupling, so the real power reduction in our setup will be more than 50%.
DC response
These modulators have an SMA-connectorized "RF" input, as well as two bare pins connected to a separate set of "DC" electrodes (they also have two more pins connected to the cathode and anode of an internal PD, presumably at the other MZ output port, which is kind of cool). As far as I can tell, the RF input is also DC coupled, only it is 50-ohm terminated.
I did a DC sweep of both electrodes from 0-10 V while measuring the output power:

(The RF applied voltage range is lower due to sagging from the 50-ohm load).
Fitting these curves, I determined the following Vpis:
These are consistent with the numbers listed on the datasheet.
Transfer functions
Next I measured the actuation transfer functions ([RIN/V]) from 1 Hz to 100 MHz, driving the RF input while applying a mid-fringe bias to the DC input, and using
- Agilent 35670A FFT analyzer and the 1811 DC output for 1 Hz - 50 kHz, and
- Agilent 4395A RF analyzer and the 1811 AC output for 500 kHz - 100 MHz
Note the dead zone from 50-500 kHz---this was by accident, as I forgot to check the low-frequency resolution of the RF measurement. I will redo this sometime.
Here are the results:

Notes:
- The jump from 50 kHz - 500 kHz is from the measurement dead zone and carries no information
- The lag beginning around 10 kHz is from the stated ~50 kHz bandwidth of the DC output of the 1811. The AC output has a low end at ~25 kHz, so there isn't really a good way to make a measurement in this region with that detector. We could use a DC-coupled version to make a continuous spectrum.
- The slow rollup at low frequencies is well-sampled and repeatable. I'm not sure what causes it, but it appears to be real. In any case, it's pretty small.
- The delay at high frequencies is consistent with the optical path length from the modulator to the PD. I calibrated the cables' transfer function out, and what is left is this delay which has a 4.13-m free-space equivalent. There is ~64 cm of free-space travel on the table, plus well over a meter from the output fiber of the modulator.
The response very flat, and roughly what is expected from the DC sweep:
(1/P0) * dP/dV|mid-fringe = pi/Vpi ~ 0.5 ( = -6 dB). |
1186
|
Fri Dec 19 18:02:33 2014 |
Chris | Lab Infrastructure | Control System | cymac model at 64K rate | I upped the sample rate of the x1cry model to 64K, in the following way:
- Change
rate=16K to rate=64K in the Simulink model
- Recompile, reinstall
- Fix the filter coefficients in the Foton file
The only tricky part is the last step. Changing the sample rate requires the filter coefficients to be updated, so they still match the filter designs. But when you open the filter file in Foton, it does the opposite: updates the designs so they match the old, incorrect coefficients. Since x1cry had only a few filters defined, I went through the file and reverted the designs by hand. (Newer versions of Foton would let you automate this step.) |
1185
|
Thu Dec 18 03:39:32 2014 |
Zach | Laser | SiFi | free-running laser frequency noise | I spent some time tonight measuring the free-running laser beat noise in various ways. Recall that, as of yesterday, I had tried setting up a couple analog PLLs to no avail and I didn't trust the spectrum I was getting from the Zurich PLL. So, I wanted to measure it another way to see if I could corroborate.
First, eye candy:

Now, an explanation of the various measurements.
I-Q demodulation method

This is a method I have used with some success in measuring the Marconi noise in its quietest state (with no modulation and therefore no means of feedback---see ATF:1877). It is done in the following way:
- Split the beat PD output and send it to the RF input of two mixers (I used level-7 ZAD-1-1s), using equal path lengths.
- Set Marconi to a frequency close to the beat (~50 MHz in this case) and an amplitude of +10 dBm
- Split the Marconi output, send one splitter output to each mixer from (1), but with 90º rotation between them.
- The outputs of the mixers are now at the difference frequency between the beat and the Marconi, but maintain their I-Q separation. (This is the reason for using the Marconi rather than beating the lasers at a lower frequency in the first place---the I-Q separation is maintained regardless of the differential laser drift, and it also only requires a short cable length.)
- Acquire both I and Q signals and perform the I-Q analysis:
- Normalize the signals and atan2(I,Q) to get phi, then unwrap(phi) to get continuous phase evolution vs time
- diff(detrend(phi))/diff(t)/2/pi to get instantaneous frequency as a function of time
- pwelch
The main complication here is that, as you can see in the plot, the high-frequency RMS of the beat is several tens of kHz, which means you still have to sample at a high rate to get what you need. The best acquisition scheme I could think of was the Zurich box, which can do 460 kS/s. Still, to take meaningful data, I had to very carefully tune the laser beat to the Marconi LO and then quickly engage acquisition before the (wildly fluctuating) IF signals drifted above the Nyquist frequency (around one second of data was used to make this trace).
That said, the result doesn't look that crazy, and in fact it agrees very well with the DFD measurement that was carried out in a completely different way (see below).
Delay-line frequency discriminator (DFD) method

This is the usual scheme where one mixes a signal with a time-delayed version of itself to create dispersion. What I did:
- Split the PD signal
- Using one splitter output, find the appropriate combination of attenuators and amplifiers needed to obtain a LO-worthy +7-dBm signal (I needed -7 dB and then ~+25 from a ZFL-500-LN) and send it to a mixer LO input via a long (several-meter) cable.
- Send the other output to the mixer RF input via a short cable (attenuate if necessary---wasn't in my case).
- Verify that the DC level of the IF output varies sinusoidally with the beat frequency
- Null the output and measure the frequency resolution. I measured 5.5 nV/Hz.
- Amplify with SR560 and measure spectrum on spectrum analyzer
- Divide spectrum by SR560 gain and the number in (5) to get frequency noise
This method worked swimmingly and reproduced exactly the result I found using the I-Q scheme. The noise floor (cyan in the plot) was measured by sending a quiet Marconi sine wave of the same amplitude and frequency as the beat through the pipeline.
Zurich PLL method
This method is incredibly straightforward. Simply plug the beat (ensuring it's < 1 Vrms and under 50 MHz) into the Zurich box and lock the internal PLL by pressing "ON" on the screen. Route the PLL control signal to one of the front panel outputs and choose the scale factor in V/Hz. I chose the same number as I measured for the DFD (including the SR560 gain) for ease of comparison on the spectrum analyzer.
Results
- All methods agree below ~50 Hz
- The I-Q and DFD methods agree everywhere, but they are higher than the PLL result by ~2 from 50 Hz to around 10 kHz, above which they re-converge somewhat
- All traces (save for the PLL in a narrow band from ~50-500 Hz) are higher than those on the spec sheets sent with the laser (shown in black on the plot---note that the West laser is everywhere noisier than the East one).
I'm not sure what to believe. One would think the Zurich PLL is the most trustworthy, but a) I still am bothered by the time-domain behavior I see in the PLL control signal when I adjust the laser beat while watching it, and b) I've generated two nearly identical spectra that differ from it using completely different schemes from measurement to FFT.
All that said, I think the excess noise (and thanks to Dmass for saving me time by pointing this out) is just coming from the ThorLabs drivers, so this should be redone when we have our low-noise ones.
|
1184
|
Wed Dec 17 18:11:38 2014 |
Zach | Laser | SiFi | Lasers mounted, energized, beat set up |
Quote: |
If the "locked indicator" light is not green on the Zurich (first tab, under "Reference", then what you get out is junk (e.g. you have unlocked the lock in, and i hasn't re-acquired yet) - you can do this by kicking it too hard with a frequency shift, which would be easy to do if you were slewing laser frequency, as the coefficients of the laser [Hz/mA] is so big. When the lock in loses the signal, you have to manually re-lock it (toggle off and on the button which has the mouseover text: "enable the fixed center frequency mode of the PLL"). You can get something which sort of looks like a PLL signal which has terrible noise and weird glitchy response when the lock in isn't locked in.
Your instinct to look for slewing at the PLL control point is correct, and a sign that the state of the PLL is healthy/unhealthy
|
Yes, I noticed this effect. I'm talking about immediately after acquiring---or re-aquiring---PLL lock. I did this several times at different beat frequencies to see what effect it had on the noise (the spectrum changed considerably, which is another bad sign). |
1183
|
Wed Dec 17 14:40:15 2014 |
Dmass | Laser | SiFi | Lasers mounted, energized, beat set up |
- With Dmass's help, locking a Zurich PLL to the free-running beat. This appeared to work, and we saw a preliminary frequency noise spectrum that looked about right, but I'm skeptical because the control signal doesn't seem to respond to my slewing one laser's frequency
- Briefly, locking one laser to the other at low frequencies using the Zurich PLL control signal as a frequency discriminator. This didn't work, adding to my suspicion.
If the "locked indicator" light is not green on the Zurich (first tab, under "Reference", then what you get out is junk (e.g. you have unlocked the lock in, and i hasn't re-acquired yet) - you can do this by kicking it too hard with a frequency shift, which would be easy to do if you were slewing laser frequency, as the coefficients of the laser [Hz/mA] is so big. When the lock in loses the signal, you have to manually re-lock it (toggle off and on the button which has the mouseover text: "enable the fixed center frequency mode of the PLL"). You can get something which sort of looks like a PLL signal which has terrible noise and weird glitchy response when the lock in isn't locked in.
Your instinct to look for slewing at the PLL control point is correct, and a sign that the state of the PLL is healthy/unhealthy
|
1182
|
Wed Dec 17 13:54:19 2014 |
Zach | Laser | SiFi | Lasers mounted, energized, beat set up | On Monday, after I did some inventory of all the parts we have received from various companies, Dmass helped me mount the RIO lasers into their mounts so that I could get started with the optical setup. We cleaned the surfaces with methanol, applied a small layer of silver thermal compound, and then screwed them in.
I then borrowed the following to run the lasers:
- The (separate) ThorLabs diode driver and temperature controller from Haixing's maglev setup
- An integrated ThorLabs diode driver / temperature controller from the TCS lab
After finding the right cables, I powered up the lasers and verified the P-I curve for each as listed on the spec sheets.
I then built a quick (temporary) optical beat setup, combining the two beams on an 1811. I had the temperatures (actually, thermistor resistances) set to what was listed as the testing set point on the datasheet, and as soon as I overlapped the beams and focused them onto the PD, there was already a strong ~50 MHz optical beat.

I have spent some time since then trying to lock various kinds of PLLs, both to interrogate the free-running frequency noise and to get used to controlling the lasers. Some things I've tried:
- Locking a Marconi to the free-running beat, which I think might be an exercise in futility due to the relatively small range of the Marconi FM
- Locking one laser to the other directly using a PLL, which I think might be an exercise in futility due to the bandwidth of the current actuation from the ThorLabs driver
- With Dmass's help, locking a Zurich PLL to the free-running beat. This appeared to work, and we saw a preliminary frequency noise spectrum that looked about right, but I'm skeptical because the control signal doesn't seem to respond to my slewing one laser's frequency.
- Briefly, locking one laser to the other at low frequencies using the Zurich PLL control signal as a frequency discriminator. This didn't work, adding to my suspicion.
The first two were not helped by the fairly basic loop shaping afforded by attenuators and an SR560.
I think my next step will be to simply use the I-Q demodulation method (like I did to measure the no-FM Marconi noise in ATF:1877) to measure the frequency noise. I'll compare that to what I get with the Zurich PLL. |
1181
|
Wed Dec 17 13:24:00 2014 |
Zach | Lab Infrastructure | SiFi | Cryostat unpacked (x-post from SUS elog) | (I realized that we should probably use the CRYO elog rather than the SUS one, so I've reposted this here).
[Nic, Zach]
Today, we unpacked the IR Labs cryostat that will be the centerpiece of the Cryo SUS experiment. 
Everything was more or less in order, except that the baseplate does not have any outward extensions with which to mount the cryostat to the table. Also, the holes for the screws holding the baseplate to the barrel are not countersunk. So, as of right now, the entire cryostat sits on these screws' caps, which is not ideal. We need to either a.) get a new baseplate made up with some wings on it and countersinking for the screws, or b.) work out another way to hold and mount the cryostat (for example, we might want some soft isolating material there anyway, though it will come at the expense of alignment drift).
I followed the instructions and removed the strange anodized heat shield bottom plate that comes with it during shipping, replacing it with the usual one and then resealing the chamber. As directed, I also pumped out the air again---the charcoal getter is not supposed to be exposed to atmosphere for long periods of time. |
1180
|
Fri Dec 12 17:15:00 2014 |
Dmass | Noise Hunting | Noise Budget | West Photothermal Transfer Function Actually Measured | Photothermal (and other absorption effects) actually measured.
Cavity loss at 300K is 10ppm for west cavity. Fit looks very good, and jives with our understanding of the transfer functions. More to follow. |
Attachment 1: W_Ptherm300K.png
|
|
1179
|
Mon Dec 8 16:12:28 2014 |
Chris | Electronics | General | Using the prologix gpib adapter | The 4395A network analyzer in the Cryo lab takes ages to save data to floppy. Someone had hooked up a Prologix GPIB-ethernet adapter to it, but it wasn't working on our network. I set it up as follows:
- Prologix adapter: autoconfigure by DHCP
- Cryo router's DHCP server: reserve IP address 10.0.5.222 for the Prologix
So, it acts like it has the static address 10.0.5.222 while on the cryo network -- but you can still take it to other networks and use it without monkeying with the settings.
Python scripts copied over from the 40m are installed on gaston, in the directory ~controls/netgpibdata. The AG4395A.py script was tested and works (much faster than the floppy drive).
While testing, Nic and I found and disabled a rogue DHCP server running on the framebuilder. |
1178
|
Sun Dec 7 12:42:55 2014 |
rana | Noise Hunting | Noise Budget | Scatter Noise hump is RAM |
I think that if you see a signal in the demodulated PDH error point with the cavity unlocked, that this must be RF AM on the light.
What mechanism would produce this much AM? It can't be made through common path modulation of the carrier and sidebands. It must be an etalon formed somewhere between the EOM and the input mirror of the suspended cavity. Could be windows / viewports; this can be tested with the ND filter insertion technique we discussed on Wednesday. |
1177
|
Fri Dec 5 12:50:24 2014 |
Dmass | Notes | General | dBm conversion table | The 4395 saved data in dBm/Hz while displaying Vrms/rtHz, so I had to figure out the conversion factor, and found the following useful table:

|
1176
|
Thu Dec 4 19:52:11 2014 |
nicolas | Electronics | General | Using the Zurich HF2 built in PLL |
The Zurich Instruments HF2 has a very nice built in PLL feature. You give it a sine wave up to 50MHz and it will lock a PLL on it, and it will give the control signal at one of the outputs.
It has a nice PLL design interface (first attachment) (the design can be compared to the measured closed loop gain in the second attachment, this doesn’t include the marconi frequency modulation calibration). You tell it the bandwidth you want and it can internally set it’s PID to achieve that, and it will complain if you are asking it for too much. It claims to be able to get a 50kHz UGF, but I was only reliably able to get like 20kHz.
So right off the bat, this won’t be what we want if our goal is a very high BW PLL to suppress whatever nonlinear noise mechanism Rana and Dmass are worried about.
However, if 20kHz BW is enough, then this might be a pretty nice PLL to use. With a 1MHz modulation range, 20kHz PLL BW, and a 20MHz carrier, the noise is given in the last attachment. (below 1mHz/rtHz up to 1kHz, then starts to rise like f until it hits the PLL bandwidth, and it rolls off again.) The red trace is the spectrum analyzer noise.
data and scripts are all here.
|
Attachment 1: 45.png
|
|
Attachment 2: PLLCLG.pdf
|
|
Attachment 3: PLLNoise.pdf
|
|
1175
|
Thu Dec 4 02:45:49 2014 |
Dmass | Noise Hunting | Noise Budget | Noise budget cleaning up | PDH sensing noise:

New lower sensing noise with addition of transformers between LO and RF in both paths.
Cavity unlocked (detuned with temp) noise shows the scatter bump - unsure if this is interesting or should be totally obvious
LBservo noise:

The LB input noise gets to a minimum of 40 nV/rtHz if we turn the gain 100% up at high freq. This is 4x over what they claim
(shown it is 50 nV/rtHz)
Data is all on svn and will be put into noisebudget update |
1174
|
Wed Dec 3 17:02:31 2014 |
Dmass | Noise Hunting | Noise Budget | Noise budget cleaning up | Looked at noisebudget on SVN and some of the measurements are dated / no loner applicable:
Update Noisebudget:
- PDH sensing noise with transformers in demod chain
- LB1005 input referred noise with low pass + higher gain setting
- Current driver output noise (measured across resistive load with Rai's low noise preamp)
- PDH loops E+W
- Transmitted RIN E+W (potentially new minima)
Take and compare:
- Err and control for E+W PDH past 100 kHz (and scope RMS / peak to peak vs integrated RMS of PSD)
|
1173
|
Wed Dec 3 15:43:15 2014 |
Dmass | Noise Hunting | Meetings | Meeting notes | ISS - what Koji has done with ISS/FSS would be good to copy - sum in DC offset at end of ISS box -
Stefan - input to last stage - change + pin to offset
Check out Nic's old elog after recp't of NEOS drivers - want [ V_rf / V_aud ]
Noise to back of AOM driver (SR785 -> SR560), measure RIN, measure beat, see beat increase
Check out Evan's median subtraction algo (to estimate coupling of RIN) - this takes median of spectra
RIN on transmission - coherent or not?
ND filter before PBS - increase power by X, decrease using ND filter
Isolators good? These are untested-ish - do we want translation stages for these?
Coherent white noise added into error point?
High freq noise at monitor PDs + low PD bandwidth (what PDs are we using / do we see the high RIN on the beat PD)?
Birefringence in coatings leading to multiple peaks with overlapping PDH error signals?
Get FTB-1-1 minicircuits transformers - skip RF grounding for now
New PLL scheme - mix beat down into low band
Zurich PLL?
Other servo boxes if no zurich: Old uPDH box? PDHv1? Misc NIM servo boards?
AD829 xover with SR560 for PLL?
PLOT Look at PLL RMS when beat, make PLL rms go down |
1172
|
Tue Dec 2 22:51:52 2014 |
Dmass | Noise Hunting | Noise Budget | Beat spectrum not ltd by | Talked to Rana about the increase in sensing noise due to DC grounding in the PDH demod electronics (we were plugging the Gold PD directly into the mixer- he confirmed that we want transformers here)
He agreed that we want to not make monstrously sized ground loops and should use transformers for DC isolation like so:

I borrowed a pair of "balanced to unbalanced" 1:1 transformers in the PSL/CTN lab and stuck them in the readout chain - the noise went down.
I tried all four permutations of balanced / unbalanced on both the LO and RF inputs of the mixer - I saw no difference in noise between these.
There is no grounding done at RF in these mixers (I opened and looked). I have seen grounding put into the transformers in other demod chains.
Questions I need answered:
-
What kind of transformers do we want to buy for this?
-
What are the consequences of not grounding / grounding the transformer at RF (say with a 4 nF cap across the ground which gives => 1 ohm at 33 MHz)
Slightly downstream of this I (previously) made another change in the setup: here is a picture of what I added between the LB1005 box and the driver:

The LB1005 is a P-I with crossover at 30 kHz (near the cav pole)
The RC filter between the driver and LB acts as 40 dB of low frequency boost
Measurements/plots wanted:
- Sensing noise for each path with transformers in play
- LB1005 + atten input ref noise (I believe the atten doesn't change this)
- *also need: in loop error signal + ctrl sig noise out to high freq
|
1171
|
Tue Dec 2 16:12:18 2014 |
Dmass | Update | Roadmap | The week's measurements | The following measurements are being done this week:
Photothermal transfer function at 120K
Wilcoxen seismometer (accelerometer?) added to setup
Cold seismic noise (boiling noise)
Cold temp noise
Cold beat w/ Weiner subtraction of PDH** / intensity / seismic
**PDH error signal f-domain Weiner subtraction @ low gain regime |
1170
|
Tue Dec 2 16:05:06 2014 |
Dmass | Noise Hunting | Cryo ISS | ISS loops almost work | [Dmass, Nic]
We resurrected the intensity loops on Friday. They almost work.
Why is it difficult?
- The AOM driver we have is only linear over a narrow range of input voltages, and requires an offset:
- Approximately 500 mV linear range with offsets of +/- 600 mV (the driver is symmetric and does roughly the same thing with + or - inputs at the back
- Outside of these regions we see major harmonic distortion / clipping
- The ISS servo board has a fixed input offset (the voltage on transmission PD which it tries to to via the AOM) - can tune the power / make a voltage divider
- The ISS servo board does NOT have any way of independently tuning the output offset
- We resorted to fine tuning the power at transmission via the input power in order to set the offset to exactly what we wanted:
- We drove the AOM driver in its linear range with the cavities locked, plugged the transmission into the ISS servo box, and looked at the signal coming out of the ISS servo box - we tuned it close to the correct offset for the input of the AOM driver (with a negative sign and lots of gain) by eye/scope
- We closed the loop and gently fiddled with the input power, and were able to lock the ISS
- IT WAS EXTREMELY FINNICKY (re: there was a very narrow range of input power that it would lock for, the spectrum was nonstationary/bouncy, and it would break after a minute or so at max)
- We have ~5% fluctuation in RIN at transmission due to the platform swinging
- We could re-lock by fine tuning the input power again and get another couple minutes.
- The boosts worked.
Does it work?
- Almost / sort of. We could get fast measurements done with it, but it will require constant babysitting and quick spectra collection
- It does not have enough range to make it into the "healthily working" category.
|
1169
|
Tue Nov 25 23:11:41 2014 |
Dmass | Noise Hunting | Cryo ISS | Anomalous intensity noise | We still have the strangely large intensity noise in both paths.
The lowest transmitted RIN we have measured in lab is:
- White up to the cavity pole
- 1/f after the cavity pole
- few times 1e-5
- Decades higher than the intensity noise on the beam measured simultaneously right before the crytostat, via a pickoff mirror
A plot of the [RIN/Hz] transfer function as a function of offset from cavity resonance is below -
Maximum possible value is 2.5e-5 RIN/Hz
When we have tuned offsets to try to make this go away (in the past), we have not been crazy offset. I think a reasonable estimate based on this, and transmitted power optimization is < 0.5 RIN/Hz
If we had a monstrous offset (~40 kHz), the frequency noise required to produce this is ~1Hz/rtHz, which is well in excess of our previous best beat
=> the intensity noise measured at transmission is not frequency noise + offset
Nic and I are turning on the ISS and taking a beat tomorrow, to see if Intensity noise -> frequency noise coupling is currently limiting (photothermal)
Musings -
Would there be any way to get white jitter noise which couples into intracavity power but not into the input PDs?
We discovered that we can effect the intensity noise with the half-wave plate right before the cryostat input window - the L/4 plate next to it has no effect.
I would suspect laser feedback**, but measured frequency noise at transmission, and laser output intensity noise are both too low, unless it could somehow be laser feedback induced jitter which looked white up to high frequency?
** because it is so easy to mode hop the lasers even with Faraday's at their output
|
Attachment 1: CavHz2RIN.png
|
|
1168
|
Tue Nov 25 22:45:43 2014 |
Dmass | Noise Hunting | Noise Budget | New beat spectrum: | I was artificially limiting my PLL range by directly driving the Marconi with the IF output of the mixer - this restricted it to ~500mV range.
The input range of the Marconi is (measured to be) +/- 2V (~ 8x higher than the mixer output I was using. Free-ish lunch here.
We might have to wait until we're cold to have low enough drift to use the Marconi in any truly low noise way, but I believe it's no longer limiting at even room temperatures. Beat noise spectra tomorrow. |
1167
|
Tue Nov 25 16:06:55 2014 |
Dmass | Things to Buy | PDH | EOM response | I replicated Koji's impedance measurement setup for those-who-cannot-afford-an-impedance-mesaurement-kit (a la this elog), but did not see any large dips in the impedance from mechanical features. I guess this is not so surprising, as the coupling of acoustic modes into impedance isn't necessarily large.
After discussing with Chris, we decided to misalign the polarisation into the EOM and measure the transfer function of Volts -> RIN.
Attached are plots of [RIN/V] through the EOM - the magnitude fluctuates with the polarization misalignment, but the phase remained consistent.
Using this as a proxy for [rad / V], it is unclear which one would be easier to use as a high frequency path - The West EOM has a much higher Q single resonance, and larger phase excursion, but we might be able to correct for it electronically, whereas the East EOM has larger more frequent phase excursions at lower frequency.
REGARDLESS, both of these EOMs are in use for generating sidebands, and if we want to have a high frequency phase correction path, we need to purchase two more EOMs**
** we explored using a bias T at the laser to switch to laser current mod produced sidebands to free up the EOMs and save $$, but this made the laser noise go up and we were unable to track down the culprit over a couple days. We also began to explore making a circuit which had resonant gain and DC coupling so that we could use one EOM for both paths, but we found little enough evidence that this was efficient (but it is interesting), and thus abandoned it. |
Attachment 1: EOM_V2RINcompare_full.png
|
|
Attachment 2: EOM_V2RINcompare_zoom.png
|
|
1166
|
Wed Nov 19 14:54:36 2014 |
nicolas | Noise Hunting | Noise Budget | ISS servo fail? |
Quote: |
I tried to implement the ISS servo today for the east path with little to no success
It it not clear to me that the servo was engineered with the actual driver in mind
The AOM driver is only linear over a narrow input range: [156mV to 450 mV] (can be + or -)
The ISS board seems to go to not have this offset built in, and it is not clear if the excitation inputs would be an appropriate place to add this.
I played around with using terminators on the input and output signals to try to force the DC value at the output of the ISS board to the middle of the linear range, but could not get the loop to do any actual intensity noise suppression for any switching state on the front
I punt to Nic, interim king of ISS servo board, following the passing of Prince Chaz, rightful heir to the throne, to determine what the correct way to sum an offset into the output of the board is.
|
It's not pretty, but the servo will create the output offset internally because of the low frequency boost and integrator. When you close the loop, it will push the driver into the linear range. |
1165
|
Mon Nov 3 20:36:14 2014 |
Dmass | Noise Hunting | Noise Budget | New beat spectrum: | Noise floor is marconi noise in PLL (see elog:1049)
Explored anomalous intensity noise with Chris. Were able to get sizable decrease in the noise by tuning the L/2 plates on the input beam.
No change to beat spectrum level.
With both temperature loops engaged, beat drift rate is 400Hz/sec.
RMS frequency noise from PDH loops is ~200Hzrms - mostly from Fourier frequencies 100kHz to 500kHz
Might be able to get away with 2kHz Marconi range if we take care of the drift rate => this problem might disappear @ 120K because of the zero crossing
Would need a 400 Hz marconi range (assuming no other noise pops up) to see coating thermal noise @ 1kHz
What noise/range did the DFD box from the 40m end up hitting? |
1164
|
Mon Nov 3 20:27:28 2014 |
Dmass | Noise Hunting | Noise Budget | ISS servo fail? | I tried to implement the ISS servo today for the east path with little to no success
It it not clear to me that the servo was engineered with the actual driver in mind
The AOM driver is only linear over a narrow input range: [156mV to 450 mV] (can be + or -)
The ISS board seems to go to not have this offset built in, and it is not clear if the excitation inputs would be an appropriate place to add this.
I played around with using terminators on the input and output signals to try to force the DC value at the output of the ISS board to the middle of the linear range, but could not get the loop to do any actual intensity noise suppression for any switching state on the front
I punt to Nic, interim king of ISS servo board, following the passing of Prince Chaz, rightful heir to the throne, to determine what the correct way to sum an offset into the output of the board is. |
1163
|
Mon Nov 3 16:15:21 2014 |
Dmass | Noise Hunting | Noise Budget | Beat spectrum not ltd by | I looked at the sensing noise (which goes WAY up when the ground of the IF port of the mixer touches the ground of the servo box - from 13 nV to 100 nV)
Sensing noise, input referred servo box noise, and in loop err signal noise are ALL below the current beat limit ( ~ 7e-2 Hz/rtHz around 1kHz ) by ~5x
We should figure out what this noise floor is. |
|