ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
11898
|
Tue Dec 22 16:44:03 2015 |
gautam | Update | General | FS725 Rubidium reference - REPAIRED |
|
|
11897
|
Tue Dec 22 16:39:42 2015 |
Steve | Update | endtable upgrade | ETMY optical table enclosure | I think there should be a scientifically
based aveluation of the ETMY enclosure so
we can make the ETMX better. |
  |
11896
|
Tue Dec 22 16:23:33 2015 |
gautam | Update | IOO | Input alignment to PMC tweaked | When I came in this afternoon, I saw that
the PZT voltage to the PMC had railed. Following
the usual procedure of turning the servo |
|
11895
|
Mon Dec 21 14:31:41 2015 |
Steve | Update | PEM | Rat traps set | Two mechanical and two sticdky traps were
set to catch univited visitor.
Absolutely |
|
11894
|
Mon Dec 21 02:29:49 2015 |
ericq | Update | LSC | AUX X RIN measurements | I'll finish up the beat / frequency
noise parts of the diagnosis tomorrow
later, but I've done some investigation |
|
11893
|
Sun Dec 20 23:23:54 2015 |
ericq | Update | ALARM | Rats. | A small rat / large mouse just ran through
the control room. Ugh. |
|
11892
|
Fri Dec 18 17:37:04 2015 |
rana | Update | LSC | Uncooperative AUX X | Here's how we should diagnose the EX
laser:
Compare IR RIN of laser |
|
11891
|
Thu Dec 17 16:44:03 2015 |
gautam | Update | CDS | ALS Slow control MEDM screen updated |
|
|
11890
|
Thu Dec 17 14:02:05 2015 |
gautam | Update | CDS | IPC channels for beat frequency control set up | I've set up two IPC channels that take
the output from the digital frequency counters
and send them to the end front-ends (via |
|
11889
|
Thu Dec 17 01:55:16 2015 |
ericq | Update | LSC | Uncooperative AUX X | [ericq, Gautam]
We were not able to fix the excess
frequency noise of the AUX X laser by the |
|
11888
|
Wed Dec 16 23:15:28 2015 |
ericq | Update | Green Locking | Green beat channels temporarily set up as IR beat channels | With the IR beats going to the nominal
ALS channels as Gautam left them, we're
able to measure the free running frequency |
|
11887
|
Wed Dec 16 18:34:40 2015 |
gautam | Update | Green Locking | Green beat channels temporarily set up as IR beat channels | Since there
are a few hours to go before the locking
efforts tonight, I've temporarily borrowed |
|
11886
|
Wed Dec 16 10:56:22 2015 |
gautam | Update | CDS | hard reboot of FB | [ericq,gautam]
Forgot to submit this yesterday...
While we were trying to get the |
|
11885
|
Wed Dec 16 10:22:14 2015 |
Steve | Update | IOO | this morning | c1sus and c1ioo were restarted. PMC locked.
|
|
11884
|
Tue Dec 15 18:08:22 2015 |
Max Isi | Update | General | Summary archive cleaning cron job | I have added a new cron job in pcdev1 at
CIT using the 40m shared account. This will
run the /home/40m/DetectorChar/bin/cleanarchive |
|
11883
|
Tue Dec 15 11:22:53 2015 |
gautam | Update | CDS | c1scx and c1asx crashed | I noticed what I thought was excessive
movement of the beam spot on ITMX and
ETMX on the control room monitors, and when |
|
11882
|
Mon Dec 14 23:56:29 2015 |
ericq | Update | CDS | c1pem reverted | To get C1PEM data back into the frames,
I removed the new BLRMS blocks, recompiled,
reinstalled, re-enabled it in daqd, restarted. |
|
11881
|
Mon Dec 14 23:49:03 2015 |
ericq | Update | Optical Levers | Calibration of oplevs for ITMX/ETMX |
|
|
11880
|
Mon Dec 14 16:46:42 2015 |
ericq | Update | WienerFiltering | Noise Subtraction Puzzler | Here's something to ponder.
Our online MCL feedforward uses
perpendicular vertex T240 seismometer signals |
|
11879
|
Mon Dec 14 16:27:11 2015 |
gautam | Update | Green Locking | Y-end AUX PDH noise breakdown | Summary:
I've
attached the results from my measurements |
 |
11878
|
Mon Dec 14 14:08:49 2015 |
Steve | Update | SUS | Ruby wire standoffs update | Two companies are willing to make
the ruby grooves and the third one is still
working on their quote. |
|
11877
|
Sun Dec 13 21:55:28 2015 |
gautam | Update | Green Locking | Y end laser (Lightwave) PZT calibration | Summary:
After
the discussions at the Wednesday meeting, |
   |
11876
|
Fri Dec 11 23:12:09 2015 |
Koji | Summary | COC | Loss map measurement document | Yutaro left detailed slides for his loss
map measurement
https://dcc.ligo.org/LIGO-G1501547 |
|
11875
|
Fri Dec 11 16:16:36 2015 |
yutaro | Update | Optical Levers | Calibration of oplevs for ITMX/ETMX | Based on calibration measurement I have
done (elog
11785, 11831), I |
|
11874
|
Fri Dec 11 15:37:50 2015 |
yutaro | Update | LSC | Power recycling gain estimation from arm loss measurement | Attached is the plot of relation between
the average arm round trip loss and
power recycling gain. 2 % loss due to PR3 |
|
11873
|
Fri Dec 11 13:28:36 2015 |
Koji | Update | LSC | Power recycling gain estimation from arm loss measurement | Can I ask you to make a plot of the power
recycling gain as a function of the average
arm loss, indicating the current loss value? |
|
11872
|
Fri Dec 11 09:35:44 2015 |
yutaro | Update | LSC | Power recycling gain estimation from arm loss measurement | I took PR3 AR reflectivity and calculated
PRG (PR3 is flipped and so AR surface is
inside PRC). |
|
11871
|
Thu Dec 10 19:53:22 2015 |
yutaro | Update | LSC | strange behavior of ASDC | To check if the strange behavior of ASDC
is caused by SR2/SR3 or not, I did the following
measurement: |
  |
11870
|
Thu Dec 10 12:33:04 2015 |
yutaro | Update | LSC | strange behavior of ASDC | I did additional tests for the strange
behavior of ASCD. ETMY, ETMX and ITMY were
misaligned so that only light reflected by |
  |
11869
|
Wed Dec 9 23:16:13 2015 |
rana | Update | Computer Scripts / Programs | Nodus security | NDS2 and the usual ports so that we can
use optimus as a comsol server.
|
|
11868
|
Wed Dec 9 19:01:45 2015 |
jamie | Update | CDS | back to fb1 | I spent this afternoon trying to debug
fb1, with very little to show for it.
We're back to running from fb. |
|
11867
|
Wed Dec 9 18:45:58 2015 |
Koji | Summary | General | Network Topology Check | [Eric Q, Gautam, Koji]
We went through the network connections
to produce the mapping of the instruments. |
 |
11866
|
Wed Dec 9 11:25:55 2015 |
Steve | Update | VAC | normal RGA scan at day 435-436 | Glitches are gone. Rga scan is good
|
 |
11865
|
Tue Dec 8 23:24:08 2015 |
gautam | Update | Green Locking | Y end laser (Lightwave) PZT calibration | Summary:
I
measured the PZT actuator gain for the Lightwave |
|
11864
|
Tue Dec 8 15:57:16 2015 |
yutaro | Summary | LSC | Power recycling gain estimation from arm loss measurement | I estimated power recycling gain with the
results of arm loss measurement.
From elog |
|
11863
|
Tue Dec 8 15:40:48 2015 |
Steve | Update | VAC | glitchy RGA scan at day 434 | The noise floor of the Rga scan is glitching
less today
|
|
11862
|
Tue Dec 8 15:18:29 2015 |
ericq | Update | Computer Scripts / Programs | Nodus security | I've done a couple things to try and
make nodus a little more secure. Some have
worried that nodus may be susceptible to |
|
11861
|
Tue Dec 8 11:24:45 2015 |
yutaro | Summary | Computer Scripts / Programs | Scripts for loss map measurement | Here I explain usage of my scripts
for loss map measurement. There are 7 script
files in a same directory /opt/rtcds/caltech/c1/scripts/lossmap_scripts. With |
|
11860
|
Mon Dec 7 15:56:35 2015 |
yutaro | Update | LSC | XARM lock with ITMX actuated and related change on ASS | I changed the snapshot file for ASS, /opt/rtcds/caltech/c1/scripts/ASS_DITHER_ON.snap
as follows: |
|
11859
|
Mon Dec 7 11:25:10 2015 |
jamie | Update | CDS | daqd is mad |
|
|
11858
|
Mon Dec 7 11:17:51 2015 |
Steve | Update | VAC | noisy RGA scan at day 433 |
|
|
11857
|
Mon Dec 7 11:11:25 2015 |
yutaro | Summary | LSC | round trip loss of X arm | On the day before yesterday and in this
morning, I measured loss map of ETMX. I reported
the method I used to change the beam spot |
 |
11856
|
Mon Dec 7 10:45:21 2015 |
ericq | Update | CDS | daqd is mad | Since removing c1pem from the daqd master
file, daqd has not crashed. I suppose we're
running into the stability issue that motivated |
|
11855
|
Mon Dec 7 10:40:09 2015 |
yutaro | Update | Computer Scripts / Programs | Added 1 line to UNFREEZE_DITHER.py | I added 1 line to one of the ASS scripts,
UNFREEZE_DITHER.py like this:
L29> ez.cawrite('C1:ASS-'+dof+'_GAIN', |
|
11854
|
Mon Dec 7 00:45:28 2015 |
ericq | Update | CDS | daqd is mad | I glanced at the summary pages and noticed
that, since Friday around when we first
loaded up the new BLRMS parts, daqd has crashing |
|
11853
|
Sat Dec 5 21:57:32 2015 |
yutaro | HowTo | Cameras | When image capture does not work... | I don't know if just running "modprobe"
will work or not, because I didn't try
it... When the same problem happens |
|
11852
|
Sat Dec 5 21:28:33 2015 |
Koji | HowTo | Cameras | When image capture does not work... | Do we need "make" everytime?
Do you mean just running "modprobe"
didn't work? |
|
11851
|
Sat Dec 5 12:02:25 2015 |
yutaro | HowTo | Cameras | When image capture does not work... | Today image capture did not work again,
though it had worked 3 days before. I also
found that red indicator light on the |
|
11850
|
Fri Dec 4 23:02:13 2015 |
yutaro | Update | LSC | Beam on POX11 is possibly not centered well | [yutaro, Koji]
Now, the beam on POX11 PD is well
centered and well focused. |
  |
11849
|
Fri Dec 4 18:20:36 2015 |
gautam | Update | CDS | BLRMS for IMC setup | [ericq, gautam]
BLRMS filters
have been set up for the coil outputs and |
 |