Tue Oct 18 18:56:57 2016 |
gautam | Update | General | OM5 rotated to bypass OMC, green scatter is from window to PSL table | [ericq, lydia, gautam]
We started today by checking
leveling of ITMY table, all was okay on that |
   |
12567
|
Tue Oct 18 17:11:42 2016 |
Yinzi | Update | Green Locking | More serial port troubleshooting | I connected to the serial port using |
|
12566
|
Mon Oct 17 22:45:16 2016 |
gautam | Update | General | AS beam centered on all OMs | [ericq, lydia, gautam]
IMC realignment, Arm
dither alignment |
7x |
12565
|
Mon Oct 17 14:48:12 2016 |
Steve | Update | safety | safety training | Ashley Fowler "high shool"
student received basic 40m safety training
and Lydia is her guarding angle. |
|
12564
|
Fri Oct 14 19:59:09 2016 |
Yinzi | Update | Green Locking | Continuing work with the TC 200 | Oct. 15, 2016
Another attempt (following elog
8755) |
|
12563
|
Fri Oct 14 18:33:55 2016 |
gautam | Update | General | AS clipping investigations | [steve,ericq,gautam]
In the afternoon, we took the heavy
door off the OMC chamber as well, such that |
7x |
12562
|
Fri Oct 14 15:47:00 2016 |
rana | Update | Treasure | filters + clip | I say just fix the clipping. Don't
worry about the PRM OSEM filters. We can
do that next time when we put in the ITM |
|
12561
|
Fri Oct 14 10:31:53 2016 |
gautam | Update | General | doors are off ITMY and BS/PRM chambers | [steve,ericq,gautam]
We re-checked IMC locking, arm
alignments (we were able to lock and dither |
|
12560
|
Thu Oct 13 19:28:14 2016 |
gautam | Update | General | in-air alignment | I did the following today to prepare for
taking the doors off tomorrow.
Locked MC at low power
low |
|
12559
|
Thu Oct 13 16:48:34 2016 |
Steve | Update | VAC | vent 79 is completed | IFO is at atmosphere. The MC can be locked
in air now.
The doors will be coming off tomorrow |
|
12558
|
Thu Oct 13 14:49:57 2016 |
Koji | Configuration | PEM | XLR(F)-XLR(M) cable took from the fibox to the Blue microphone | [Gautam Koji]
XLR(F)-XLR(M) cable for the blue
microphone is missing. Steve ordered one. |
|
12557
|
Thu Oct 13 09:30:38 2016 |
Steve | Update | General | vent 79 is happening |
|
 |
12556
|
Thu Oct 13 00:23:54 2016 |
ericq | Update | VAC | Pre-vent prep | I have completed the following non-Steve
portions of the pre-vent checklist [wiki-40m.ligo.caltech.edu]
Center all oplevs, transom |
|
12555
|
Wed Oct 12 22:51:26 2016 |
Koji | Update | General | Clipping could not be improved by the PZTs - NEED ANOTHER VENT | [Gautam Koji]
We engaged the HV driver
to the output port PZTs, hoping to mitigate |
|
12554
|
Wed Oct 12 18:09:25 2016 |
Lydia | Update | General | Acromag Progress | [Lydia, Johannes]
Johannes acquired a crate to contain
the Acromag setup and wiring, and installed |
|
12553
|
Wed Oct 12 15:01:22 2016 |
steve | Update | SUS | SOS ITM baffles plates are ready | The two 40 mm apeture baffles at the ends
were replaced by 50 mm one. ITM baffles with
50 mm apeture are baked ready for installation. |
  |
12552
|
Wed Oct 12 13:34:28 2016 |
gautam | Update | SUS | PRM LR problematic again | Looks like what were PRM problems are now
seen in the SRM channels, while PRM itself
seems well behaved. This supports the hypothesis |
|
12551
|
Tue Oct 11 13:30:49 2016 |
gautam | Update | SUS | PRM LR problematic again | Perhaps the problem is electrical? The
attached plot shows a downward trend for
the LR sensor output over the past 20 days |
|
12550
|
Tue Oct 11 10:38:51 2016 |
Steve | Update | SUS | wire standoffs update | 100 Sapphire prizms arrived.
|
 |
12549
|
Tue Oct 11 10:15:04 2016 |
Steve | Update | SUS | PRM LR problematic again | It started here
|
|
12548
|
Tue Oct 11 08:09:46 2016 |
Max Isi | Update | DMF | summar pages dead again | Summary pages will be unavailable today
due to LDAS server maintenance. This is unrelated
to the issue that Rana reported. |
|
12547
|
Tue Oct 11 02:48:43 2016 |
ericq | Update | LSC | Revival Attempts | Still no luck relocking, but got a little
further. I disabled the output of the problematic
PRM OSEM, it seems to work ok. Looking at |
|
12546
|
Tue Oct 11 00:43:50 2016 |
ericq | Update | SUS | PRM LR problematic again | Tonight, and during last week's locking,
we noticed something intermittently kicking
the PRM. I've determined that PRM's |
  |
12545
|
Mon Oct 10 18:34:52 2016 |
gautam | Update | General | PZT OM Mirrors | I did a quick survey of the drive electronics
for the PZT OM mirrors today. The hope is
that we can correct for the clipping observed |
|
12544
|
Mon Oct 10 17:42:47 2016 |
Max Isi | Update | DMF | summar pages dead again | I've re-submitted the Condor job; pages
should be back within the hour.
|
|
12543
|
Mon Oct 10 17:27:29 2016 |
rana | Update | DMF | summar pages dead again | Been non-functional for 3 weeks. Anyone
else notice this? images missing since ~Sep
21. |
|
12542
|
Mon Oct 10 11:48:05 2016 |
gautam | Update | CDS | Power-cycled c1susaux, realigned PMC, spots centered on WFS1 and WFS2 | [Koji, Gautam]
We did the following today morning:
I re-aligned the PMC - |
|
12541
|
Mon Oct 10 09:31:25 2016 |
Steve | Update | SUS | PRM damping restored | Local earth quake 3.7 mag trips PRM
ETMY_UL glitch
What about the MC? |
  |
12540
|
Fri Oct 7 20:56:15 2016 |
Koji | Update | SUS | Output matrix diagonalization | I wanted to see what is the reason to have
such large coupling between pitch and yaw
motions. |
 |
12539
|
Fri Oct 7 20:25:14 2016 |
Koji | Update | CDS | Power-cycled c1psl and c1iool0 | Found the MC autolocker kept failing, It
turned out that c1iool0 and c1psl went bad
and did not accept the epics commands. |
|
12538
|
Fri Oct 7 15:36:03 2016 |
Steve | Update | PEM | the lab temp is up | The IFO room temp is up
|
 |
12537
|
Fri Oct 7 10:29:57 2016 |
Steve | Update | VAC | RGA removed | The RGA is removed for repaire. It's
volume at atmophere and sealed.. P4 reading
of 38 Torr is not correct. |
|
12536
|
Thu Oct 6 15:42:51 2016 |
Lydia | Update | SUS | Output matrix diagonalization | Summary: At the 40m meeting yesterday,
Eric Q. gave the suggestion that we
accept the input matrix weirdness and adjust |
|
12535
|
Thu Oct 6 03:56:43 2016 |
ericq | Update | LSC | Revival Attempt | [ericq, Gautam, Lydia]
We spent some time tonight trying
to revive the PRFPMI. (Why PR instead of |
|
12534
|
Wed Oct 5 19:43:13 2016 |
gautam | Summary | General | Vent review | This elog is meant to review some of the
important changes made during the vent this
summer - please add to this if I've forgotten |
|
12533
|
Wed Oct 5 19:10:04 2016 |
gautam | Update | General | Arm loss measurement review | [ericq,gautam]
There are multiple methods by which
the arm loss can be measured, including, |
|
12532
|
Wed Oct 5 16:28:10 2016 |
gautam | Update | endtable upgrade | EX laser power monitor PD installed | I installed a 10% BS to pick off some of
the light going to the IR fiber, and have
added a Thorlabs PDA55 PD to the EX table |
|
12531
|
Tue Oct 4 22:18:24 2016 |
Johannes | Update | General | X/YARM loss measurement | [gautam, johannes]
We let the PSL shutter closed overnight
and observed the POXDC, POYDC and ASDC offsets. |
|
12530
|
Tue Oct 4 11:02:31 2016 |
Steve | Update | VAC | RGA is out of order | The last good rga scan at vent 78
day 38
|
|
12529
|
Tue Oct 4 02:59:48 2016 |
ericq | Update | General | mucking about | [ericq, gautam]
We poked around trying to figure
out the X PDH situation. In brief, the glitchiness |
|
12528
|
Mon Oct 3 21:24:02 2016 |
Johannes | Update | General | XARM loss measurement | [gautam, johannes]
I started a script on Friday night
to collect some data for a reflection armloss |
|
12527
|
Sat Oct 1 10:03:28 2016 |
ericq | Update | General | mucking about | Some things I did last night:
I measured the X PDH OLG, and turned
the gain down by ~6dB to bring the UGF back |
|
12526
|
Fri Sep 30 19:53:07 2016 |
gautam | Update | endtable upgrade | X end IR pickoff fiber coupled | [johannes, gautam]
Today we re-installed the fiber
coupler on the X-endtable to couple some |
|
12525
|
Fri Sep 30 10:37:57 2016 |
Steve | Update | VAC | vacuum VME machines rebooted | [ Gautam and Steve ]
c1vac1 and c1vac2 were rebooted
and the gauges are communicating now. V1, |
|
12524
|
Thu Sep 29 20:21:29 2016 |
Johannes | Update | General | YARM loss measurement | [Gautam, Johannes]
I scripted a series of YARM DC
reflectivity measurements last night alternating |
|
12523
|
Thu Sep 29 16:19:29 2016 |
Lydia | Update | SUS | Free swing eigenmodes | [Lydia, Teng]
Motivated by the strange pitch/yaw
coupling behavior we ran into while doing |
 |
12522
|
Thu Sep 29 09:49:53 2016 |
rana | Update | General | mucking about | With the WFS and OL, we never have figured
out a good way to separate pit and yaw. Need
to figure out a reference for up/down and |
|
12521
|
Wed Sep 28 04:27:33 2016 |
ericq | Update | General | mucking about | PMC was terribly misaligned. The PMCR camera
seems to have drifted somewhat off target
too, but I didn't touch it. |
 |
12520
|
Tue Sep 27 18:04:50 2016 |
Lydia | Update | SUS | ITMX slow channels down, ITMY diagonalization update | [Teng, Lydia]
When we plugged in the back cables
yesterday on the whitening boxes after switching |
|
12519
|
Tue Sep 27 08:49:47 2016 |
Steve | Update | SUS | seismic activity is up | The earth quake shook ITMX free for a
short while.
|
 |