40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 94 of 171  Not logged in ELOG logo
   +  Reply  Fri Oct 14 18:38:41 2011, kiwamu, Update, SUS, C1:SUS-ETMX_SPDMon fixed 
   +  Reply  Fri Oct 14 04:35:45 2011, kiwamu, Update, LSC, locking tonight Screen_shot_2011-10-14_at_4.24.01.png
   +  Reply  Thu Oct 13 21:40:59 2011, rana, Summary, VAC, Recovery from the power shutdown is completed 
Entry  Thu Oct 13 20:25:32 2011, Katrin, Update, Green Locking, LPF transfer function YARM designLPF.pngLC_LPF.TIF
Entry  Wed Oct 12 19:58:32 2011, Katrin, Update, Green Locking, Power splitter is unbalanced 
Entry  Wed Oct 12 18:54:02 2011, Katrin, Update, Green Locking, 60 Hz oscillation due to broken BNC cable 
   +  Reply  Wed Oct 12 17:53:01 2011, kiwamu, Update, LSC, BS actuator response : fitting done and histroy of delays bode_BSactuator.png
Entry  Wed Oct 12 00:35:42 2011, kiwamu, Update, LSC, TRY path realigned 
   +  Reply  Tue Oct 11 21:23:51 2011, Jenne, Update, LSC, Arm absl lengths 
   +  Reply  Tue Oct 11 17:32:05 2011, jamie, HowTo, Environment, 40m google maps link 
Entry  Tue Oct 11 00:59:55 2011, Suresh, Update, IOO, Preliminary locking of WFS loops 6x
Entry  Mon Oct 10 18:53:04 2011, Katrin, Update, Green Locking, Mirrors whose angle of incidence is not 45 
   +  Reply  Mon Oct 10 16:32:18 2011, steve, Update, SUS, UL sensor of ETMY is recovered ETMY_UL.pngETMY_OSEM_UL.pngnoisyETMY_UL.png
Entry  Mon Oct 10 15:41:56 2011, Koji, Update, PSL, PMC aligned 
   +  Reply  Mon Oct 10 13:52:04 2011, kiwamu, Update, LSC, RE: First attempt to estimate mode matching efficiency using interferometer 
Entry  Mon Oct 10 12:14:00 2011, Mirko, Update, Computer Scripts / Programs, IMC simulations opticke_xaxis.pngDC_power.pngDC_power_B.pngIMC_simulation.zip
   +  Reply  Mon Oct 10 10:14:43 2011, rana, Update, LSC, length fluctuations in SRCL 
   +  Reply  Sat Oct 8 00:44:42 2011, kiwamu, Update, LSC, calibration of SRM actuator actuators.png
Entry  Fri Oct 7 22:48:26 2011, Suresh, Update, IOO, MC2 Trans QPD spot size and incident power decreased 
Entry  Fri Oct 7 22:41:05 2011, Koji, Configuration, General, Script backup fixed  
Entry  Fri Oct 7 19:06:46 2011, Suresh, Update, IOO, MC spot positions: checked and corrected. 
Entry  Fri Oct 7 17:35:26 2011, Katrin, Update, Green Locking, Power on green YARM table DSC_3496_power.JPG
   +  Reply  Fri Oct 7 11:53:47 2011, Koji, Update, LSC, DRMI locked and some plans 
Entry  Fri Oct 7 11:45:24 2011, Koji, Summary, LSC, POY11 installed, 55MHz PD at POY removed 
Entry  Thu Oct 6 15:37:26 2011, Jenne, Update, Green Locking, Y-green Mech Shutter Button 
   +  Reply  Thu Oct 6 05:18:20 2011, kiwamu, Update, LSC, Noise in AS55 was from clipping : fixed  outofloop.png
Entry  Wed Oct 5 18:31:02 2011, Katrin, Update, Green Locking, Exchanged mirror on YARM table 
Entry  Wed Oct 5 17:08:49 2011, steve, Update, SUS, BS oplev spectra BSoplservON2.png
   +  Reply  Wed Oct 5 14:18:09 2011, kiwamu, Update, CDS, some DAQ channel lost in c1sus : fb, c1sus and c1pem restarted 
Entry  Tue Oct 4 20:34:20 2011, Katrin, Update, Green Locking, 7kHz Peak in servo input YARM servoinput.pngservoinput2.png
   +  Reply  Tue Oct 4 19:06:46 2011, Koji, Update, IOO, closed the shutter before the MC 
   +  Reply  Tue Oct 4 16:58:45 2011, Suresh, Update, PSL, AM / PM ratio 
Entry  Tue Oct 4 16:10:45 2011, Suresh, Update, Computer Scripts / Programs, MC was not damping 
   +  Reply  Tue Oct 4 15:57:30 2011, Suresh, Update, IOO, MC Trans channels are digital 0 
Entry  Tue Oct 4 10:35:08 2011, Mirko, Update, CDS, c1lsc and c1sus running again 
   +  Reply  Tue Oct 4 07:51:36 2011, steve, Update, CDS, c1lsc and c1sus are still down 
Entry  Mon Oct 3 23:52:49 2011, kiwamu, Update, CDS, some more tests for the Dolphin  
   +  Reply  Mon Oct 3 17:57:12 2011, kiwamu, Update, ASC, IPPOS fixed 
   +  Reply  Mon Oct 3 17:06:27 2011, Jenne, HowTo, Computer Scripts / Programs, Kissel Button Generator 
   +  Reply  Mon Oct 3 16:18:05 2011, Jenne, Update, Adaptive Filtering, Meditations on the OAF 
   +  Reply  Mon Oct 3 13:04:12 2011, Jenne, Update, SUS, AUXEX, AUXEY rebooted 
Entry  Sun Oct 2 18:33:36 2011, kiwamu, Update, SUS, inversion of the input matrix on ETMX, ITMX and PRM ETMX.pngPRM.pngITMX.png
Entry  Sun Oct 2 02:21:27 2011, kiwamu, Update, SUS, free swinging test once more 
   +  Reply  Fri Sep 30 19:12:56 2011, Koji, Update, General, prep for poweroutage 
Entry  Fri Sep 30 18:06:24 2011, kiwamu, Summary, IOO, PZTs straing guage beforeOutage110930.png
Entry  Fri Sep 30 17:01:29 2011, steve, Update, SUS, ETMX oplev intensity effect on noise ETMXoplintens.jpgP1080267.JPG
   +  Reply  Fri Sep 30 16:17:10 2011, kiwamu, Update, Green Locking, things to be done for the Yarm green lock 
Entry  Fri Sep 30 03:36:19 2011, Suresh, Update, Computer Scripts / Programs, CIOO modified, but not yet compiled 
   +  Reply  Fri Sep 30 03:14:18 2011, kiwamu, Update, CDS, suspension became crazy : c1sus rebooted  
   +  Reply  Fri Sep 30 01:18:39 2011, kiwamu, Update, ASC, C1ASS : status update 
ELOG V3.1.3-