ID |
Date |
Author |
Type |
Category |
Subject |
6159
|
Tue Jan 3 15:49:27 2012 |
Jamie | Update | Computers | possible front-end timing issue |
Quote: |
Is there a reason the framebuilder status light is red for all the front ends?
Also, I reenabled PRM watchdog.
|
Apparently there is a bug in the timing cards having to do with the new year roll-over that is causing front-end problems. From Rolf:
For systems using the Spectracom IRIG-B cards for timing information, the code did not properly roll over the time for
2012 (still thinks it is 2011 and get reports from DAQ of timing errors (0x4000)). I have made a temporary fix for this
in the controller.c code in branch-2.3, branch-2.4 and release 2.3.1.
I was going to check to see if the 40m is suffering from this. I'll be over to see if that's the problem. |
6168
|
Wed Jan 4 09:06:50 2012 |
steve | Update | Computers | possible front-end timing issue |
Quote: |
Quote: |
Is there a reason the framebuilder status light is red for all the front ends?
Also, I reenabled PRM watchdog.
|
Apparently there is a bug in the timing cards having to do with the new year roll-over that is causing front-end problems. From Rolf:
For systems using the Spectracom IRIG-B cards for timing information, the code did not properly roll over the time for
2012 (still thinks it is 2011 and get reports from DAQ of timing errors (0x4000)). I have made a temporary fix for this
in the controller.c code in branch-2.3, branch-2.4 and release 2.3.1.
I was going to check to see if the 40m is suffering from this. I'll be over to see if that's the problem.
|
The problem is the same as yesterday. |
6171
|
Wed Jan 4 16:40:52 2012 |
Jamie | Update | Computers | front-end fb communication restored |
Communication between the front end models and the framebuilder has been restored. I'm not sure exactly what the issue was, but rebuilding the framebuilder daqd executable and restarting seems to have fixed the issue.
I suspect that the problem might have had to do with how I left things after the last attempt to upgrade to RCG 2.4. Maybe the daqd that was running was linked against some library that I accidentally moved after starting the daqd process. It would have kept running fine as was, but if the process died and was attempted to be started again, it's broken linking might have kept it from running correctly. I don't have any other explanation.
It turns out this was not (best I can tell) related to the new year time sync issues that wer seen at the sites. |
6243
|
Fri Feb 3 10:48:24 2012 |
Den | Update | Computers | c1lsc kernel |
This morning I killed again c1lsc kernel with the new realization of fxlms algorithm. It works fine with gcc compiler during the tests. However, smth forbidden for the kernel is going on. I'll spend some more time on investigatin it. Interesting thing is that I did not even pressed "On" at the OAF MEDM screen to make the code running. c1lsc suspended even before. May be there is some function-name mismatch.
After c1lsc suspention I recomiled back non-working code and rebooted c1lsc. c1sus is also bad after c1lsc reboot as they communicate. I killed x04, lsc, ass, oaf models on the c1lsc computer and sus, mcs, rfm, pem on the c1sus computer. Then I restarted x02 model and restored its burt snapshot from 08:07. After I started all models back and restored their burt snapshots from 08:07. Then I diag reset all started models.
Before starting new fxlms code I've shutted down all the optics so that possible c1lsc suspention would not make them crazy. After reboot I turned the coils back. Everything seems to work fine. |
6249
|
Fri Feb 3 17:29:28 2012 |
Den | Update | Computers | c1lsc kernel |
The reason I've killed the c1lsc kernel was the following - when the code starts to run, it initializes some parameters and this takes ~0.2 msec per dof. Now, the old code did nothing with a DOF if C1:OAF-ADAPT_???_ONOFF == OFF. My code still initialized the parameters but then does nothing because no witness channels are given. But it spends 8*0.2 = 1.6 msec for initializing all 8 dof. As the code is called with frequency 2k, this was the reason for crashing. Now I've corrected my code, it compiles, runs and does not kill c1lsc. However, the old code would also kill the kernel if all DOF are filtered. So, when we'll use all 8 DOF, we'll have to split variable initialization.
But this is not the biggest problem. C1OAF model must be corrected, because, as for now, all 8 DOF call the same ADAPT_XFCODE function. As this function uses static variables, they will be all messed up by different DOF signals. |
6314
|
Fri Feb 24 16:10:48 2012 |
mike | Update | Computers | PyNDS and a Plot |
Power Spectral Density plot using PyNDS, comparing 5 fast data channels for ETMX.
**EDIT** Script here:
import nds
import numpy as np
import matplotlib.pyplot as plt
import time
daq=nds.daq('fb', 8088)
channels=daq.recv_channel_list()
e=0
start=int(time.time()-315964819)
rqst=['C1:SUS-ETMX_SENSOR_UR','C1:SUS-ETMX_SENSOR_UL','C1:SUS-ETMX_SENSOR_LL','C1:SUS-ETMX_SENSOR_LR','C1:SUS-ETMX_SENSOR_SIDE'] #Requested Channels
for c in channels:
if c.name in rqst:
daq=nds.daq('fb', 8088)
data=daq.fetch(start-100, start, c.name)
vars()['psddata'+str(e)], vars()['psdfreq'+str(e)]=plt.psd(data[0],NFFT=16384,Fs=c.rate)
vars()['label'+str(e)]=c.name
e+=1
plt.figure(1)
plt.clf()
plt.title('PSD Comparison')
plt.grid(True, which='majorminor')
plt.xlabel(r'Frequency $Hz$')
plt.ylabel(r'Decibels $\frac{dB}{Hz}$')
for x in np.arange(0,e):
plt.loglog(psdfreq0, 10*vars()['psddata'+str(x)], label=vars()['label'+str(x)])
plt.legend()
plt.show() |
6316
|
Fri Feb 24 18:59:04 2012 |
Jenne | Update | Computers | PyNDS and a Plot |
Quote: |
Power Spectral Density plot using PyNDS, comparing 5 fast data channels for ETMX.
|
Is there any stuff to install, etc? Y'know, for those of use who don't really know how to use computers and stuff.... |
6341
|
Wed Feb 29 17:32:11 2012 |
Mike | Update | Computers | PyNDS and a Plot |
Quote: |
Quote: |
Power Spectral Density plot using PyNDS, comparing 5 fast data channels for ETMX.
|
Is there any stuff to install, etc? Y'know, for those of use who don't really know how to use computers and stuff....
|
No new stuff for these computers. Everything should be installed already. |
6431
|
Tue Mar 20 17:50:44 2012 |
Suresh | Update | Computers | Beam Scan machine fixed |
There was something wrong with the Beam Scan PC. The mouse and screen were not responding and the PC was asking for drivers for any new hardware that we plugged in. We called in the services of Junaid and co. since we do not have a Win98 Second Edition installation disk in the lab. Junaid came with the disk, we changed the screen and the mouse and installed everything.
We tried to get the network going on the PC so that we could update stuff easily over the net. This didnt succeed. For now, we still have to depend on a Win98se CD to get drivers if any new hardware is connected to this machine.
For future reference, some notes:
1) We will get a copy of Win98SE for the lab from Junaid
2) We have to use a USB mouse from Dell. We have several spares of this. The drivers for these are present in the machine.
The Beam Scan is working okay now. We will proceed with the beam profile measurements. |
6434
|
Wed Mar 21 19:12:27 2012 |
steve | Update | Computers | AC power back on both ends |
Quote: |
Quote: |
ETMY sus damping was disabled. Green locking laser and associated electronics turned off. Computers and power supplies turned off at rack 1Y4
The electricians picking up ac power from 1Y4 manual disconnect box and installing conduit line to ISCT-ETMY east end optical table.
There will be no more daisy chaining this way.
|
The power is back on at ETMY . c1iscey has not been restarted.
Now I'm turning ac power off at ETMX for the same job to be done.
|
The power was turned back on at 4pm It took some time for Suresh to restart the computers. We have damping but things are not perfect yet. Auto BURTH did not work well. |
6463
|
Wed Mar 28 21:15:53 2012 |
rana | Omnistructure | Computers | Wireless router for GC |
I installed a NETGEAR Wireless Router (WPN824N) today on the 131 network. The admin password for it as well as the wireless access password are in the usual places.
The SSID is 40EARTH. I have set it to allow WPA as well as WPA2 access, so the speed is only 54 Mbps for now. In a year or so, we can turn off the WPA support and up the speed. |
6465
|
Thu Mar 29 13:23:05 2012 |
Jenne | Omnistructure | Computers | Wireless router for GC |
Quote: |
I installed a NETGEAR Wireless Router (WPN824N) today on the 131 network. The admin password for it as well as the wireless access password are in the usual places.
The SSID is 40EARTH. I have set it to allow WPA as well as WPA2 access, so the speed is only 54 Mbps for now. In a year or so, we can turn off the WPA support and up the speed.
|
This router was confiscated by the GC guys this morning around ~10am. They barged in and said that someone at the 40m had connected a new router, and we had magically taken down half of the GC network. The cable was plugged in to the wrong port on the back of the router.
Junaid / Christian said that they would "secure" the router, and then reinstall it. Apparently just having a password didn't satisfy them. This was the compromise, versus them just taking the router and never bringing it back.
|
6467
|
Thu Mar 29 19:13:56 2012 |
Jamie | Omnistructure | Computers | Wireless router for GC |
I retrieved the newly "secured" router from Junaid. It had apparently been hooked up to the GC network via it's LAN port, but it's LAN services had no been shut off. It was therefore offering a competing DHCP server, which will totally hose a network. A definite NONO.
The new SSID is "40mWiFi", it's WPA2, and the password is pasted to the bottom of the unit (the unit is back in it's original spot on the office computer rack. |
6479
|
Tue Apr 3 12:42:19 2012 |
Mike J. | Update | Computers | Hysteresis Model |
Here's my first hysteresis model in Simulink. It's based on the equation y=Amplitude*sin(frequency*t+phase)+(hysteresis/frequency2) as a solution to y''+frequency2*y+hysteresis=0. All values in the model are variables that should be manipulated through the model workspace or external code. |
6485
|
Wed Apr 4 21:43:16 2012 |
Mike J. | Update | Computers | Better Hysteresis Model |
A better hysteresis model based on the simple harmonic oscillator equation. Useless variables have been removed and output can now be saved to workspace for plotting. The model is at "/users/mjenson/matlab/SHO_hyst.mdl". |
6487
|
Thu Apr 5 01:07:08 2012 |
Mike J. | Update | Computers | Hysteresis Plots |
Here are the hysteresis plots from the most recent model, which uses a modified harmonic oscillator equation y''=-(Frequency)2*y-Hysteresis. The hysteresis constant seems to change both the amplitude and equilibrium point of the pendulums, which is akin to changing the length of a pendulum without changing the frequency. This does not make sense. Perhaps the hysteresis value should be moved to the "spring" constant for the pendula and not restricted to a position-biasing value.

|
6494
|
Fri Apr 6 11:32:09 2012 |
Jenne | Update | Computers | RAID array is rebuilding.... |
Suresh reported to Den, who reported to me (although no elogs were made.....) that something was funny with the FB. I went to look at it, and it's actually the RAID array rebuilding itself. I have called in our guru, Jamie, to have a look-see. |
6495
|
Fri Apr 6 14:39:21 2012 |
Jamie | Update | Computers | RAID array is rebuilding.... |
The RAID (JetStor SATA 416S) is indeed resyncing itself after a disk failure. There is a hot spare, so it's stable for the moment. But we need a replacement disk:
RAID disks: 1000.2GB Hitachi HDT721010SLA360
Do we have spares? If not we should probably buy some, if we can. We want to try to keep a stock of the same model number.
Other notes:
The RAID has a web interface, but it was for some reason not connected. I connected it to the martian network at 192.168.113.119.
Viewing the RAID event log on the web interface silences the alarm.
I retrieved the manual from Alex, and placed it in the COMPUTER MANUALS drawer in the filing cabinet. |
6498
|
Fri Apr 6 16:35:37 2012 |
Den | Update | Computers | c1ioo |
c1ioo computer can not connect to the framebuilder and everything is red in the status for this machine, C1:FEC-33_CPU_METER is not moving.
EDIT by KI:
We rebooted the c1ioo machine, but none of the ftont end model came back. It looked like they failed the burt process for some reasons according to dmesg.
Then we restarted each front end model one by one, and every time after immediately we restarted it we hit the 'BURT' button in the GDS screen.
Everyone came back to the normal operation. |
6502
|
Fri Apr 6 20:24:31 2012 |
Mike J. | Update | Computers | Sensoray |
The Sensoray device is currently viewing Monitor 4 and plugged into Pianosa. The user interface is run at /home/controls/Downloads/sdk_2253_1.2.2_linux/python demo.py. It can preview and capture the video stream, however the captured files are terrible. I believe it has something to do with the bitrate, since the captured video with lower bitrates are not as bad as the ones with higher bitrates, but I am not certain. |
6503
|
Fri Apr 6 20:38:41 2012 |
Mike J. | Update | Computers | Sensoray |
Turns out that the "MPEG-4 VES" video format is just bad for captured video. Everything except "MP4" and "MPEG-TS" works for streaming, and "MP4" and "MPEG-TS" seem to be the only captured formats that can be viewed properly. |
6505
|
Sat Apr 7 01:45:02 2012 |
Mike J. | Update | Computers | Even Better Hysteresis Model and Plots |
The new hysteresis model is slightly based on the SHO equation, but with the force being out of phase with the position by an amount of hysteresis {x(t)=Amp*sin(freq*t), F(t)=Amp*sin(freq*t+Hyst)}. The new model can be found at /users/mjenson/matlab/hyst_v_3.mdl. Pictures are: new hysteresis model, x(t) subsystem in new model[xh''(t) only lacks -1 multiplier and includes hysteresis variable], new plots.
 .png?lb=40m&thumb=1)  |
6507
|
Sat Apr 7 02:01:29 2012 |
Mike J. | Update | Computers | Projector Cable Management |
I replaced the projector video and power cables with longer ones, and zip-tied them to the ceiling and wall so they don't block the image.

|
6513
|
Mon Apr 9 20:02:19 2012 |
Mike J. | Update | Computers | Sensoray |
The highest resolution available is 720x480 pixels. Bit depth of captured images and video is most likely 16 bits per pixel. Video may be captured raw as well, which will be necessary for image subtraction/enhancement, however it cannot currently be played raw. A captured image is shown below, along with MP4 video.
|
6517
|
Tue Apr 10 23:56:44 2012 |
rana | Update | Computers | Sensoray |
Now that Mike has got the Sensoray working, Jenne/Suresh should grab some new images of the ETM cage as Keiko did so that we can analyze them for another mode matching diagnostic. |
6518
|
Wed Apr 11 12:25:11 2012 |
Ryan | Update | Computers | Updating aLIGO Conlog |
Over the next few days, I will be working on upgrading the aLIGO Conlog install to include new bugfixes distributed by Patrick T. The currently running conlog *should* not be affected, but please let me know if it is (ryan.fisher@ligo.org). |
6530
|
Thu Apr 12 22:04:17 2012 |
Mike J. | Update | Computers | New Hysteresis Model & Plots |
The new hysteresis model uses a triangle wave with offset zero points as the position function and a sinusoidal force function, creating a loop similar to this. Model is at /users/mjenson/matlab/ferro_hyst.mdl.
 
|
6539
|
Tue Apr 17 10:55:50 2012 |
Ryan | Update | Computers | Updating aLIGO Conlog |
Quote: |
Over the next few days, I will be working on upgrading the aLIGO Conlog install to include new bugfixes distributed by Patrick T. The currently running conlog *should* not be affected, but please let me know if it is (ryan.fisher@ligo.org).
|
The upgrade to the aLIGO Conlog is completed. The conlog is once again running on megatron in a screen session. (see http://nodus.ligo.caltech.edu:8080/40m/6396) |
6585
|
Mon Apr 30 18:46:34 2012 |
rana | Update | Computers | megatron |
Last week I found that megatron was still off after the power outage. Apparently, the power recovery checklist had not been followed during the recovery.
Please remember to use the checklist and post the checklist results after each power outage. Megatron is now on and functioning. |
6592
|
Tue May 1 17:42:15 2012 |
Mike J. | Update | Computers | Sensoray |
I've upgraded the Sensoray GUI so it can now switch the video channel it receives, thanks to the videoswitch script.

|
6645
|
Tue May 15 23:40:46 2012 |
Mike J. | Update | Computers | Image Subtraction |
I acquired 2 raw frames of MC2 using "/users/mjenson/sensoray/sdk_2253_1.2.2_linux/capture -n -s 720x480 -f 1", one while the laser was off the mode cleaner and another while it was on:

I then used "/users/mjenson/sensoray/sdk_2253_1.2.2_linux/imsub/display-image.py" to generate bitmaps of the raw images, which I then subtracted using the Python Imaging Library to generate a new image:

It doesn't look all that different, but the first image didn't have that much lit up in it to begin with. I should be able to write a script that does all of this without needing to generate new files in between acquisition and subtraction. |
6646
|
Wed May 16 11:53:45 2012 |
Jenne | Update | Computers | Image Subtraction |
Quote: |
It doesn't look all that different, but the first image didn't have that much lit up in it to begin with.
|
This is totally cool! You can see that the OSEM lights are almost entirely gone in the subtracted image.
Can you switch to trying with one of the *TM*F cameras? (ITMXF, ITMYF, ETMYF, ETMXF) They tend to have more background, so there should be a more dramatic subtraction. Den or Suresh should be able to lock one of the arms for you. |
6662
|
Tue May 22 20:24:06 2012 |
Jamie | Update | Computers | rossa is now running Ubuntu 10.04 |
Now same as pianosa and rosalba. I'll upgrade allegra on Friday. |
6677
|
Thu May 24 16:13:05 2012 |
yuta | Update | Computers | ASS scripts on new ubuntu machines |
[Den, Yuta]
Background:
ASS and many other scripts don't work on new ubuntu machines.
What we did:
1. Installed C-shell on rossa and rosalba(Ubuntu machine).
sudo apt-get insall csh
2. Find out that
/opt/rtcds/caltech/c1/scripts/AutoDither/alignY
runs, but
/opt/rtcds/caltech/c1/scripts/medmrun /opt/rtcds/caltech/c1/scripts/AutoDither/alignY
doesn't run. It gives us the following error messages.
ezcawrite: error while loading shared libraries: libca.so: cannot open shared object file: No such file or directory
ezcaswitch: error while loading shared libraries: libca.so: cannot open shared object file: No such file or directory
Result:
ASS scripts run on rossa and rosalba, but not with medmrun.
At least ASS scripts run on pianosa(ubuntu machine) with medmrun. So we decided to wait for JAMIE to fix it. |
6683
|
Fri May 25 16:58:54 2012 |
Jamie | Configuration | Computers | .bashrc for workstations |
I have setup a shared .bashrc for all the workstations that is symlinked to the normal location on all machines:
controls@rossa:~ 0$ ls -al /home/controls/.bashrc
lrwxrwxrwx 1 controls controls 23 2012-05-25 15:37 /home/controls/.bashrc -> /users/controls/.bashrc
controls@rossa:~ 0$
This should help simplify maintenance considerably. Editing that file on one machine will edit it for all. Just edit this one file! Don't try to get fancy and add extra files!
I also added a bunch of aliases that had previously been missing. This should help with some of the problems that people had been having.
NOTE: PLEASE DO NOT CHANGE THE DEFAULT SHELL! We are using bash, because that's what the sites are now using and we want to be as compatible as possible.
You can of course still write scripts in csh/tcsh or use tcsh in a shell if you wish. Just don't change the default shell for the controls user. |
6684
|
Fri May 25 17:50:38 2012 |
Jamie | Update | Computers | ASS scripts on new ubuntu machines |
Quote: |
[Den, Yuta]
Background:
ASS and many other scripts don't work on new ubuntu machines.
What we did:
1. Installed C-shell on rossa and rosalba(Ubuntu machine).
sudo apt-get insall csh
2. Find out that
/opt/rtcds/caltech/c1/scripts/AutoDither/alignY
runs, but
/opt/rtcds/caltech/c1/scripts/medmrun /opt/rtcds/caltech/c1/scripts/AutoDither/alignY
doesn't run. It gives us the following error messages.
ezcawrite: error while loading shared libraries: libca.so: cannot open shared object file: No such file or directory
ezcaswitch: error while loading shared libraries: libca.so: cannot open shared object file: No such file or directory
Result:
ASS scripts run on rossa and rosalba, but not with medmrun.
At least ASS scripts run on pianosa(ubuntu machine) with medmrun. So we decided to wait for JAMIE to fix it.
|
Apparently the environment was not being properly inherited by the scripts launched from medmrun. We modified the medmrum script so that it executes things with an interactive shell ("bash -i -c ...") and this fixed the problem (by assuring that it sources all the interactive environment configs (i.e. ~/.bashrc)). I'm still not sure why we were seeing different behavior on pianosa, but at least the solution we have now should be robust.
As a reminder, all scripts launched from MEDM should use medmrun:
/opt/rtcds/caltech/c1/scripts/medmrun
|
6685
|
Fri May 25 17:52:08 2012 |
Jamie | Update | Computers | allegra now running Ubuntu 10.04 |
The last of the control room machines is now upgraded. |
6703
|
Tue May 29 15:29:16 2012 |
Jamie | Update | Computers | latest pynds installed on all new control room machines |
The DASWG lscsoft package repositories have a lot of useful analysis software. It is all maintained for Debian "sqeeze", but it's mostly installable without modification on Ubuntu 10.04 "lucid" (which is based on Debian squeeze). Basically the only thing that needs to access the lscsoft repositories is to add the following repository file:
controls@rossa:~ 0$ cat /etc/apt/sources.list.d/lscsoft.list
deb http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze contrib
deb-src http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze contrib
deb http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze-proposed contrib
deb-src http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze-proposed contrib
controls@rossa:~ 0$
A simple "apt-get update" then makes all the lscsoft packages available.
lscsoft includes the nds2 client packages (nds2-client-lib) and pynds (python-pynds). Unfortunately the python-pynds debian squeeze package currently depends on libboost-python1.42, which is not available in Ubuntu lucid. Fortunately, pynds itself does not require the latest version and can use what's in lucid. I therefore rebuilt the pynds package on one of the control room machines:
$ apt-get install dpkg-dev devscripts debhelper # these are packages needed to build a debian/ubuntu package
$ apt-get source python-pynds # this downloads the source of the package, and prepares it for a package build
$ cd python-pynds-0.7
$ debuild -uc -us # this actually builds the package
$ ls -al ../python-pynds_0.7-lscsoft1+squeeze1_amd64.deb
-rw-r--r-- 1 controls controls 69210 2012-05-29 11:57 python-pynds_0.7-lscsoft1+squeeze1_amd64.deb
I then copied the package into a common place:
/ligo/apps/debs/python-pynds_0.7-lscsoft1+squeeze1_amd64.deb
I then installed it on all the control room machines as such:
$ sudo apt-get install libboost-python1.40.0 nds2-client-lib python-numpy # these are the dependencies of python-pynds
$ sudo dpkg -i /ligo/apps/debs/python-pynds_0.7-lscsoft1+squeeze1_amd64.deb
I did this on all the control room machines.
It looks like the next version of pynds won't require us to jump through these extra hoops and should "just work". |
6722
|
Thu May 31 00:56:13 2012 |
Jamie | Metaphysics | Computers | Please remember to check in code changes |
I know it's really hard to remember, but our future selves will thank us dearly if we remember to commit all of our code changes to the svn with nice log messages. At the moment there's a LOT of modified stuff in the userapps working directory that needs to be committed:
controls@pianosa:/opt/rtcds/userapps/release 0$ svn status | grep '^M'
M cds/c1/models/c1rfm.mdl
M sus/c1/medm/templates/SUS_SINGLE.adl
M sus/c1/models/c1mcs.mdl
M sus/c1/models/c1sus.mdl
M sus/c1/models/c1scx.mdl
M sus/c1/models/c1scy.mdl
M isc/c1/models/c1pem.mdl
M isc/c1/models/c1ioo.mdl
M isc/c1/models/ADAPT_XFCODE_MCL.c
M isc/c1/models/c1oaf.mdl
M isc/c1/models/c1gcv.mdl
M isc/common/medm/OAF_OVERVIEW.adl
M isc/common/medm/OAF_DOF_BLRMS.adl
M isc/common/medm/OAF_OVERVIEW_BAK.adl
M isc/common/medm/OAF_ADAPTATION_MICH.adl
controls@pianosa:/opt/rtcds/userapps/release 0$
This doesn't even include things that haven't even been added yet. It doesn't take much time. Just copy and paste what you elog about the changes. |
6737
|
Fri Jun 1 02:33:40 2012 |
Jenne | Update | Computers | c1sus and c1iscex - bad fb connections |
Something bad happened to c1sus and c1iscex ~20 min ago. They both have "0x2bad" 's. I restarted the daqd on the framebuilder, and then rebooted c1sus, and nothing changed. The SUS screens are all zeros (the gains seem to be set correctly, but all of the signals are 0's).
If it's not fixed when I get in tomorrow, I'll keep poking at it to make it better. |
6738
|
Fri Jun 1 08:01:46 2012 |
steve | Update | Computers | c1sus and c1iscex are down |
Quote: |
Something bad happened to c1sus and c1iscex ~20 min ago. They both have "0x2bad" 's. I restarted the daqd on the framebuilder, and then rebooted c1sus, and nothing changed. The SUS screens are all zeros (the gains seem to be set correctly, but all of the signals are 0's).
If it's not fixed when I get in tomorrow, I'll keep poking at it to make it better.
|
|
6740
|
Fri Jun 1 09:50:50 2012 |
Jamie | Update | Computers | c1sus and c1iscex - bad fb connections |
Quote: |
Something bad happened to c1sus and c1iscex ~20 min ago. They both have "0x2bad" 's. I restarted the daqd on the framebuilder, and then rebooted c1sus, and nothing changed. The SUS screens are all zeros (the gains seem to be set correctly, but all of the signals are 0's).
If it's not fixed when I get in tomorrow, I'll keep poking at it to make it better.
|
This is at least partially related to the mx_stream issue I reported previously. I restarted mx_stream on c1iscex and that cleared up the models on that machine.
Something else is happening with c1sus. Restarting mx_stream on c1sus didn't help. I'll try to fix it when I get over there later. |
6742
|
Fri Jun 1 14:40:24 2012 |
Jamie | Update | Computers | c1sus and c1iscex - bad fb connections |
Quote: |
This is at least partially related to the mx_stream issue I reported previously. I restarted mx_stream on c1iscex and that cleared up the models on that machine.
Something else is happening with c1sus. Restarting mx_stream on c1sus didn't help. I'll try to fix it when I get over there later.
|
I managed to recover c1sus. It required stopping all the models, and the restarting them one-by-one:
$ rtcds stop all # <-- this does the right to stop all the models with the IOP stopped last, so they will all unload properly.
$ rtcds start iop
$ rtcds start c1sus c1mcs c1rfm
I have no idea why the c1sus models got wedged, or why restarting them in this way fixed the issue. |
6761
|
Wed Jun 6 00:37:11 2012 |
Jenne | Update | Computers | mx_stream restarted on iscey, sus |
Just as Yuta and I were sitting down to look at our beatnote (really the output of the freq discriminator) on Dataviewer, all the FB net boxes on the CDS status screen were white. I restarted daqd, and most of the computers came back fine. c1iscey and c1sus still had some red bad boxes. So I restarted mx_stream on both, and they are now fine.
Somehow, this also fixed whatever I had done to the lsc model yesterday (although I think TRY is still not recorded at this time - not messing with it yet). |
6765
|
Wed Jun 6 14:17:56 2012 |
steve | Update | Computers | iMac ordered |
Rana, Steve,
- Part number: Z0M6
Configuration
- 2.7GHz Quad-Core Intel Core i5
- 16GB 1333MHz DDR3 SDRAM - 4x4GB
- 1TB Serial ATA Drive
- AMD Radeon HD 6770M 512MB GDDR5
- Apple Mouse
- Apple Keyboard with Numeric Keypad (English) & User's Guide
- Accessory Kit
|
6772
|
Wed Jun 6 22:04:19 2012 |
Jamie | Update | Computers | Failed attempt to get pianosa to support dual monitors |
I've spent an inordinate amount of time trying to figure out how to get pianosa to support dual monitors. It apparently has some special nvidia graphics that are not well supported in Ubuntu (10.04 at least). I've tried installing a newer kernel (3.0.0) and installing the special nvidia compile-from-source Ubuntu packages, but nothing is working. And now unfortunately he's not giving me any video at all. I'm sick of this today, so I'll try again tomorrow.
In the future we should avoid these bullshit nvidia cards like the plague. |
6773
|
Wed Jun 6 22:23:53 2012 |
Jamie | Update | Computers | Failed attempt to get pianosa to support dual monitors |
I managed to get pianosa working again with just a single monitor. I'm done trying to configure it for dual, though. |
6774
|
Wed Jun 6 22:25:05 2012 |
Jamie | Update | Computers | zita now running ubuntu 10.04 |
I'll finish the rest of the config to turn it into a full-fledged workstation tomorrow. |
6783
|
Thu Jun 7 10:39:21 2012 |
Jamie | Update | Computers | pianosa dual monitor working |
I decided to remove what I thought was the problematic extra nVidia video card, since there are already two DVI outputs build-in. The card turned out to not even be nVidia, so I don't know what was going on there.
I futzed with the BIOS to configure the primary video card, which is some new Intel card. The lucid (10.04) support for it is lacking, but it was easy enough to pull in new drivers from the appropriate Ubuntu PPA repository:
controls@pianosa:~ 0$ sudo apt-add-repository ppa:f-hackenberger/x220-intel-mesa
controls@pianosa:~ 0$ sudo apt-add-repository ppa:glasen/intel-driver
controls@pianosa:~ 0$ sudo apt-get update
...
controls@pianosa:~ 0$ sudo apt-get upgrade
Reading package lists... Done
Building dependency tree
Reading state information... Done
The following packages will be upgraded:
libdrm-intel1 libdrm-nouveau1 libdrm-radeon1 libdrm2 libgl1-mesa-dri libgl1-mesa-glx libglu1-mesa xserver-xorg-video-intel
8 upgraded, 0 newly installed, 0 to remove and 0 not upgraded.
Need to get 3,212kB of archives.
After this operation, 25.2MB disk space will be freed.
Do you want to continue [Y/n]?
...
controls@pianosa:~ 0$
After a reboot, both monitors came up fine.
http://www.subcritical.org/running_ubuntu_lts_on_sandy_bridge/ |
6784
|
Thu Jun 7 12:49:50 2012 |
Jamie | Update | Computers | zita network configured |
Added zita to the martian host table, and configured his network accordingly:
zita A 192.168.113.217
https://wiki-40m.ligo.caltech.edu/Martian_Host_Table |