Fri Jan 7 12:01:39 2011 |
Osamu | Update | Computers | c1lsc running |
I got a new adapter board for expansion chassis from CDS and exchanged the existing adapter board which was laid on the floor around ETMX to new one.
Then I connected the chassis to c1lcs, c1lsc seems to be running now. I will return the old board to CDS since Rolf says he wants to return it to manufacture.
I found an interface box from ADC to D-SUB37pin and a cable to connect them.
I needed to make cables to connect the interface box to existing LSC whitening filters that has a 37 pin female D-SUB connector on one end and a 40pin female flat connector on the other end. We should use shielded cables for them, but unfortunately CDS did not have right one. Temporarily I made one cable for 1-8ch using a ribbon twist cable like Joe did.
I found a saturation at ch5 of ADC0 on c1lsc. I did not check carefully but it seemed to come from the LSC whitening board. Input of ch5 of the whitening board was not terminated and had a huge output voltage, but also ch6 was not terminated and had no big output. I guess something wrong on the LSC whitening board. Needs to be checked. Anyway I unplugged the small ribbon cable between the whitening board and the next LSC AA filter board.
Finally I realized that fiber connection of RFM did not exist. What I saw was the fiber cable of Dolphin. We need a RFM PCIe interface board, and a long fiber cable between c1lsc and RFM hub. |
4127
|
Sat Jan 8 23:18:03 2011 |
rana | Update | Computers | network table |
There's, as usual, a disconnect between the real martian host table and the one displayed on the Wiki. Basically, the point is: DO NOT TRUST THE WIKI, because people who update the actual host table only randomly update the wiki table.
The only thing worth trusting is the file
/var/named/chroot/var/named/martian.zone
on linux 1.
You will need to have 'root' or 'sudo' to get into that directory to read the file. |
4135
|
Tue Jan 11 14:05:11 2011 |
josephb | Update | Computers | Martian host table updated daily |
I created two simple cron jobs, one running on linux1 and one running on nodus, to produce an updated copy of the martian host table linkable from the wiki every day.
The scripts live in /opt/rtcds/caltech/c1/scripts/AutoUpdate/. One is called updateHostTable.cron and run on linux1 everyday at 4 am, and the other is called moveHostTable.cron which is run on nodus everyday at 5am.
The new link has been added to the Martian Host table wiki page here.
|
4151
|
Thu Jan 13 16:34:02 2011 |
josephb | Update | Computers | 32 bit matlab updated |
There was a problem with running the webview report generator in matlab on Mafalada. It complained of not having a spare report generator license to use, even though the report generator was working before and after on other machines such as Rosalba. So I moved the old 32 bit matlab directory from /cvs/cds/caltech/apps/Linux/matlab to /cvs/cds/caltech/apps/Linux/matlab_old. I installed the latest R2010b matlab from IMSS in /cvs/cds/caltech/apps/Linux/matlab and this seems to have made the cron job work on Mafalda now. |
4162
|
Mon Jan 17 04:10:10 2011 |
rana | Configuration | Computers | NTPD restarted on c1dcuepics (to fix the MEDM screen times) |
I installed NTPD on Megatron (its Ubuntu, so different from the CentOS workstations). Here's the terminal cap to show that its actually working:
megatron:/etc>sudo /etc/init.d/ntp restart
* Stopping NTP server ntpd [ OK ]
* Starting NTP server ntpd [ OK ]
megatron:/etc>/etc/init.d/ntp status
* NTP server is running
megatron:/etc>ntpq -p
remote refid st t when poll reach delay offset jitter
==============================================================================
nodus.martian 204.123.2.72 2 u 7 64 1 0.217 3.833 0.001
europium.canoni 193.79.237.14 2 u 6 64 1 155.354 3.241 0.001
megatron:/etc>date
Mon Jan 17 04:07:08 PST 2011
Along the way, I also updated the /etc/inet/ntp.conf file for nodus. It was using the USNO as a NTP server and I've pointed it to the Caltech NTP server as per the IMSS NTP page. |
4221
|
Fri Jan 28 13:05:56 2011 |
Koji | Configuration | Computers | script path fixed |
We had some issues in terms of the script paths. I have fixed it by replacing /cvs/cds/caltech/scripts to /cvs/cds/rtcds/caltech/c1/scripts
Here is the output of diff
----------------------------------------------
rossa:caltech>diff cshrc.40m cshrc.40m.20110128
44,47c44,45
< # OBSOLETE set path = ($path /cvs/cds/caltech/scripts/general)
< # OBSOLETE set path = ($path /cvs/cds/caltech/scripts/general/netgpibdata)
< set path = ($path /cvs/cds/rtcds/caltech/c1/scripts/general)
< set path = ($path /cvs/cds/rtcds/caltech/c1/scripts/general/netgpibdata)
---
> set path = ($path /cvs/cds/caltech/scripts/general)
> set path = ($path /cvs/cds/caltech/scripts/general/netgpibdata)
50,51c48
< # OBSOLETE setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/perlmodules:/cvs/cds/caltech/libs/solaris9/usr_local_lib/perl5/5.8.0/:/cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
< setenv PERL5LIB /cvs/cds/caltech/libs/solaris9/usr_local_lib/perl5/5.8.0/:/cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
---
> setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/perlmodules:/cvs/cds/caltech/libs/solaris9/usr_local_lib/perl5/5.8.0/:/cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
61,64c58,59
< #OBSOLETE setenv PATH ${SOLARISPATH}/bin:$GDSPATH/bin:$ROOTSYS/bin:$TDSPATH/bin:/cvs/cds/caltech/scripts/general/netgpibdata:$PATH
< setenv PATH ${SOLARISPATH}/bin:$GDSPATH/bin:$ROOTSYS/bin:$TDSPATH/bin:/cvs/cds/rtcds/caltech/c1/scripts/general/netgpibdata:$PATH
< #OBSOLETE setenv SCRIPTS /cvs/cds/caltech/scripts
< setenv SCRIPTS /cvs/cds/rtcds/caltech/c1/scripts
---
> setenv PATH ${SOLARISPATH}/bin:$GDSPATH/bin:$ROOTSYS/bin:$TDSPATH/bin:/cvs/cds/caltech/scripts/general/netgpibdata:$PATH
> setenv SCRIPTS /cvs/cds/caltech/scripts
87,88c82
< #OBSOLETE setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
< setenv PERL5LIB /cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
---
> setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
99,100c93
< #OBSOLETE setenv SCRIPTPATH /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/netgpibdata
< setenv SCRIPTPATH /cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/scripts/general/netgpibdata
---
> setenv SCRIPTPATH /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/netgpibdata
103,104c96
< #OBSOLETE setenv SCRIPTS /cvs/cds/caltech/scripts
< setenv SCRIPTS /cvs/cds/rtcds/caltech/c1/scripts
---
> setenv SCRIPTS /cvs/cds/caltech/scripts
135,137c127
< #OBSOLETE alias listenDARM '/cvs/cds/caltech/scripts/c1/listenDARM'
< alias listenDARM '/cvs/cds/rtcds/caltech/c1/scripts/c1/listenDARM'
<
---
> alias listenDARM '/cvs/cds/caltech/scripts/c1/listenDARM'
156,157c146
< #OBSOLETE setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/perlmodules
< setenv PERL5LIB /cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/c1/scripts/general/perlmodules
---
> setenv PERL5LIB /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/perlmodules
167,168c156
< #OBSOLETE setenv SCRIPTPATH /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/netgpibdata
< setenv SCRIPTPATH /cvs/cds/rtcds/caltech/c1/scripts/general:/cvs/cds/rtcds/caltech/scripts/general/netgpibdata
---
> setenv SCRIPTPATH /cvs/cds/caltech/scripts/general:/cvs/cds/caltech/scripts/general/netgpibdata
172,173c160
< #OBSOLETE setenv SCRIPTS /cvs/cds/caltech/scripts
< setenv SCRIPTS /cvs/cds/rtcds/caltech/c1/scripts
---
> setenv SCRIPTS /cvs/cds/caltech/scripts
198,199c185
< #OBSOLETE alias listenDARM '/cvs/cds/caltech/scripts/c1/listenDARM'
< alias listenDARM '/cvs/cds/rtcds/caltech/c1/scripts/c1/listenDARM'
---
> alias listenDARM '/cvs/cds/caltech/scripts/c1/listenDARM'
288,295c274,277
< #OBSOLETE alias makefiltscreen '/cvs/cds/caltech/scripts/Admin/makeFilterScreen.pl'
< #OBSOLETE alias makelockinscreen '/cvs/cds/caltech/scripts/Admin/makeLockInScreen.pl'
< #OBSOLETE alias f_and_r '/cvs/cds/caltech/scripts/Admin/find_and_replace.pl'
< #OBSOLETE alias plotrgascan '/cvs/cds/caltech/scripts/RGA/plotrgascan'
< alias makefiltscreen '/cvs/cds/rtcds/caltech/c1/scripts/Admin/makeFilterScreen.pl'
< alias makelockinscreen '/cvs/cds/rtcds/caltech/c1/scripts/Admin/makeLockInScreen.pl'
< alias f_and_r '/cvs/cds/rtcds/caltech/c1/scripts/Admin/find_and_replace.pl'
< alias plotrgascan '/cvs/cds/rtcds/caltech/c1/scripts/RGA/plotrgascan'
---
> alias makefiltscreen '/cvs/cds/caltech/scripts/Admin/makeFilterScreen.pl'
> alias makelockinscreen '/cvs/cds/caltech/scripts/Admin/makeLockInScreen.pl'
> alias f_and_r '/cvs/cds/caltech/scripts/Admin/find_and_replace.pl'
> alias plotrgascan '/cvs/cds/caltech/scripts/RGA/plotrgascan'
|
4247
|
Thu Feb 3 17:25:03 2011 |
josephb | Update | Computers | rsync script was not really backing up /cvs/cds |
So today, after an "rm" error while working with the autoburt.pl script and burt restores in general, I asked Dan Kozak how to actually look at the backup data. He said there's no way to actually look at it at the moment. You can reverse the rsync command or ask him to grab the data/file if you know what you want. However, in the course of this, we realized there was no /cvs/cds data backup.
Turns out, the rsync command line in the script had a "-n" option. This means do a dry run. Everything *but* the actual final copying.
I have removed the -n from the script and started it on nodus, so we're backing up as of 5:22pm today.
I'm thinking we should have a better way of viewing the backup data, so I may ask Dan and Stewart about a better setup where we can login and actually look at the backed up files.
In addition, tomorrow I'm planning to add cron jobs which will put changes to files in the /chans and /scripts directories into the SVN on a daily basis, since the backup procedure doesn't really provide a history for those, just a 1 day back backup. |
4250
|
Fri Feb 4 13:45:25 2011 |
josephb | Update | Computers | Temporarily removed cronjob for rsync.backup |
<p>I removed the rsync backup from nodus' crontab temporarily so as to not have multiple backup jobs running. The job I started from yesterday was still running. Hopefully the backup will finish by Monday.</p>
<p>The line I removed was:</p>
<p>0 5 * * * /opt/rtcds/caltech/c1/scripts/backup/rsync.backup</p>
<table align="left" width="786" cellspacing="1" cellpadding="1" border="2">
<tbody>
<tr>
<td><span style="font-size: larger;">MC damp</span></td>
<td><span style="font-size: larger;">dataviewer</span></td>
<td><span style="font-size: larger;">diaggui</span></td>
<td><span style="font-size: larger;">AWG</span></td>
<td><span style="font-size: larger;">c1lsc</span></td>
<td><span style="font-size: larger;">c1ioo</span></td>
<td><span style="font-size: larger;">c1sus</span></td>
<td><span style="font-size: larger;">c1iscex</span></td>
<td><span style="font-size: larger;">c1iscex</span></td>
<td><span style="font-size: larger;">RFM</span></td>
<td><span style="">The Dolphins</span></td>
<td><span style="font-size: larger;">Sim.Plant</span></td>
<td><span style="font-size: larger;">Frame builder</span></td>
<td><span style="font-size: larger;">TDS</span></td>
<td><span style="font-size: larger;">Cabling</span></td>
</tr>
<tr>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="green"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="yellow"><span style="font-size: larger;"> </span></td>
<td bgcolor="orange"><span style="font-size: larger;"> </span></td>
<td bgcolor="yellow"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="yellow"><span style="font-size: larger;"> </span></td>
<td bgcolor="yellow"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="red"><span style="font-size: larger;"> </span></td>
<td bgcolor="blue"><span style="font-size: larger;"> </span></td>
<td bgcolor="orange"><span style="font-size: larger;"> </span></td>
<td bgcolor="orange"><span style="font-size: larger;"> </span></td>
</tr>
</tbody>
</table> |
4251
|
Fri Feb 4 15:03:20 2011 |
josephb | Update | Computers | Modified cshrc.40m |
Removed some lines from the PATH environment variable since they point to old codes which no longer work with the new frame builder and setup.
The change was:
#setenv PATH $LINUXPATH/bin:$GDSPATH/bin:$ROOTSYS/bin:$TDSPATH/bin:${SCRIPTPATH}:$PATH
setenv PATH $TDSPATH/bin:${SCRIPTPATH}:$PATH
|
4252
|
Fri Feb 4 18:58:19 2011 |
rana | Update | Computers | Temporarily removed cronjob for rsync.backup |
Quote: |
I removed the rsync backup from nodus' crontab temporarily so as to not have multiple backup jobs running. The job I started from yesterday was still running. Hopefully the backup will finish by Monday.
The line I removed was:
0 5 * * * /opt/rtcds/caltech/c1/scripts/backup/rsync.backup
|
Actually, this is not true. Joe actually killed the currently running backup and set it to start tomorrow morning at 6AM. Its taking forever since its not an incremental backup but a new one due to the change in the setup. |
4256
|
Mon Feb 7 10:37:28 2011 |
josephb | Update | Computers | Temporarily removed cronjob for rsync.backup |
The backup appears to have finished on nodus, and I've put the rsync job back in the crontab.
Quote: |
I removed the rsync backup from nodus' crontab temporarily so as to not have multiple backup jobs running. The job I started from yesterday was still running. Hopefully the backup will finish by Monday.
The line I removed was:
0 5 * * * /opt/rtcds/caltech/c1/scripts/backup/rsync.backup
|
|
4263
|
Tue Feb 8 16:44:43 2011 |
Jenne | Update | Computers | LIGO Grid Cluster client upgraded on Rossa |
I did a yum-install of the latest ldg-client (to get onto the LIGO Clusters) on Rossa.
I followed the instructions on the wiki page, and everything seemed to work nicely.
I think the new ldg client installs somewhere on the local computer, so if anyone wants cluster access on any other computer, they should follow the same directions. |
4271
|
Thu Feb 10 14:52:36 2011 |
Aidan | HowTo | Computers | Adding filenames in MATLAB plots |
The following code is incredibly useful when creating MATLAB plots as it adds the filename of the script to the plot itself. I think it should be used for all MATLAB plots that go on the elog.
For example, I have no idea where the data/script is that was used to generate these plots.
orient landscape
xposn = 0.0;
yposn = -0.13; % you sometimes have to tweak this value depending on the page size and the number of subplots
text(xposn,yposn,[filename('fullpath'), '.m'], ...
'Units', 'normalized', ...
'Interpreter', 'none', ...
'FontSize', 6)
print('-dpdf', [filename('fullpath'), '.pdf'])
|
4298
|
Tue Feb 15 11:43:53 2011 |
Jenne | Update | Computers | Occasional error with NDS2 |
Just in case anyone has encountered this / knows how to fix it....
I'm running NDS2 on Rossa, trying to get a bunch of raw data from S5. I get 10min of data at a time, and it goes through ~200 iterations successfully, and then throws the following error:
Getting new data
Connecting.... authenticate ... done
daq_recv_id: Wrong length read (0)
Error reading writerID in daq_recv_block
Warning: daq_request_data failed
??? Error using ==> NDS2_GetData
Fatal Error getting channel data.
Error in ==> getDARMdataTS at 37
oot = NDS2_GetData({...
Error in ==> SaveRawData_H1_DARM at 40
oot = getDARMdataTS(t0s(ii), strideDuration, srate); |
4541
|
Mon Apr 18 21:09:45 2011 |
Jamie | Configuration | Computers | new control room machine: pianosa |
I've just installed the new control room machine: "pianosa". It is a replacement for the old sun machine "op440m" [0].
Hardware:
- dual dual-core Intel Core i7-2600 CPU @ 3.40GH, hyperthreaded to provide 8 effective cores
- 16G memory (4x 4G dimms)
- nVidia GF108 GeForce GT 430
It's now running Ubuntu 10.04 LTS 64bit. Unfortunately, the default 10.04 kernel is 2.6.32, which does not support pianosa's apparently very new network adapter, which is (from lspci):
00:19.0 Ethernet controller: Intel Corporation 82579LM Gigabit Network Connection (rev 04 )
To get around this I temporarily added a PCI nic so that I could get on the network. I then added the Ubuntu kernel team PPA archive and installed linux-image-2.6.38-2, which is new enough to have the needed network driver, but not completely bleeding edge:
sudo add-apt-repository ppa:kernel-ppa/ppa
sudo apt-get update
sudo apt-get install linux-image-2.6.38-2-generic linux-headers-2.6.38-2-generic
Once the built in nic was working I removed the temporary one. Everything seems to be working fine now.
I have not yet done any configuration to integrate pianosa into the CDS network. I'll do that tomorrow.
[0] op44m has been moved into the control room rack next to linux1, in headless mode. If there is still a need to run scripts that only run on solaris, op440m can still be accessed via ssh as normal. Hopefully we can fully decommission this machine soon.
[1] https://launchpad.net/~kernel-ppa/+archive/ppa |
4542
|
Mon Apr 18 21:14:53 2011 |
Jamie | Configuration | Computers | new control room machine: pianosa |
Also, op440m's Sun monitor did not work well with pianosa, so I'm lending pianosa my HP monitor until we can get a suitable replacement. |
4549
|
Wed Apr 20 23:20:49 2011 |
jamie | Summary | Computers | installation of CDS tools on pianosa |
This is an overview of how I got (almost) all the CDS tools running on pianosa, the new Ubuntu 10.04 control room work station.
This is machine is experiment in minimizing the amount of custom configuration and source code compiling. I am attempting to install as many tools as possible from existing packages in
available packages
I was able to install a number of packages directly from the ubuntu archives, including fftw, grace, and ROOT:
apt-get install \ libfftw3-dev \ grace \ root-system
LSCSOFT
I installed all needed LSCSOFT packages (framecpp, libframe, metaio) from the well-maintained UWM LSCSOFT repository.
$ cat /etc/apt/sources.list.d/lscsoft.list deb http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze deb-src http://www.lsc-group.phys.uwm.edu/daswg/download/software/debian/ squeeze contrib
sudo apt-get install lscsoft-archive-keyring sudo apt-get update sudo apt-get install ldas-tools-framecpp-dev libframe-dev libmetaio-dev lscsoft-user-en
You then need to source /opt/lscsoft/lscsoft-user-env.sh to use these packages.
EPICS
There actually appear to be a couple of projects that are trying to provide debs of EPICS. I was able to actually get epics working from one of them, but it didn't include some of the other needed packages (such as MEDM and BURT) so I fell back to using Keith's pre-build binary tarball.
Prereqs:
apt-get install \ libmotif-dev \ libxt-dev \ libxmu-dev \ libxprintutil-dev \ libxpm-dev \ libz-dev \ libxaw7-dev \ libpng-dev \ libgd2-xpm-dev \ libbz2-dev \ libssl-dev \ liblapack-dev \ gfortran
Pulled Keith's prebuild binary:
cd /ligo/apps wget https://llocds.ligo-la.caltech.edu/daq/software/binary/apps/ubuntu/epics-3.14.10-ubuntu.tar.gz tar zxf epics-3.14.10-ubuntu.tar.gz
GDS
I built GDS from svn, after I fixed some broken stuff [0]:
cd ~controls/src/gds svn co https://redoubt.ligo-wa.caltech.edu/svn/gds/trunk cd trunk #fixed broken stuff [0] source /opt/lscsoft/lscsoft-user-env.sh ./bootstrap export GDSBUILD=online export ROOTSYS=/usr ./configure --prefix=/ligo/apps/gds --enable-only-dtt --with-epics=/ligo/apps/epics-3.14.10 make make install
dataviewer
I installed dataviewer from source:
cd ~controls/src/advLigoRTS svn co https://redoubt.ligo-wa.caltech.edu/svn/advLigoRTS/trunk cd trunk/src/dv #fix stupid makefile /opt/rtapps --> /ligo/apps make make install
I found that the actual dataviewer wrapper script was also broken, so I made a new one:
$ cat /ligo/apps/dv/dataviewer
#!/bin/bash export DVPATH=/ligo/apps/dv ID=$$ DCDIR=/tmp/${ID}DC mkdir $DCDIR trap "rm -rf $DCDIR" EXIT $DVPATH/dc3 -s ${NDSSERVER} -a $ID -b $DVPATH "$@"
environment
Finally, I made a environment definer file:
$ cat /ligo/apps/cds-user-env.sh # source the lscsoft environment . /opt/lscsoft/lscsoft-user-env.sh
# source the gds environment . /ligo/apps/gds/etc/gds-user-env.sh
# special local epics setup EPICS=/ligo/apps/epics export LD_LIBRARY_PATH=${EPICS}/base/lib/linux-x86_64:$LD_LIBRARY_PATH export LD_LIBRARY_PATH=${EPICS}/extensions/lib/linux-x86_64:$LD_LIBRARY_PATH export LD_LIBRARY_PATH=${EPICS}/modules/seq/lib/linux-x86_64:$LD_LIBRARY_PATH export PATH=${EPICS}/base/bin/linux-x86_64:$PATH export PATH=${EPICS}/extensions/bin/linux-x86_64:$PATH export PATH=${EPICS}/modules/seq/bin/linux-x86_64:$PATH
# dataviewer path export PATH=/ligo/apps/dv:${PATH}
# specify the NDS server export NDSSERVER=fb
[0] GDS was not compiling, because of what looked like bugs. I'm not sure why I'm the first person to catch these things. Stricter compiler?
To fix the following compile error:
TLGExport.cc:1337: error: ‘atoi’ was not declared in this scope
I made the following patch:
Index: /home/controls/src/gds/trunk/GUI/dttview/TLGExport.cc =================================================================== --- /home/controls/src/gds/trunk/GUI/dttview/TLGExport.cc (revision 6423) +++ /home/controls/src/gds/trunk/GUI/dttview/TLGExport.cc (working copy) @@ -31,6 +31,7 @@ #include <iomanip> #include <string.h> #include <strings.h> +#include <stdlib.h> namespace ligogui { using namespace std;
To fix the following compile error:
TLGPrint.cc:264: error: call of overloaded ‘abs(Int_t&)’ is ambiguous
I made the following patch:
Index: /home/controls/src/gds/trunk/GUI/dttview/TLGPrint.cc =================================================================== --- /home/controls/src/gds/trunk/GUI/dttview/TLGPrint.cc (revision 6423) +++ /home/controls/src/gds/trunk/GUI/dttview/TLGPrint.cc (working copy) @@ -22,6 +22,7 @@ #include <fstream> #include <map> |
4552
|
Thu Apr 21 15:03:29 2011 |
steve | Update | Computers | juction board finds home |
The anti aliasing box was opened up at the back to accommodate the junction board and the SCSI cable towards the ADC. Aluminum plate was attached to the bottom to hold the strain relief clamp.
Three more hanging junction cards will be replaced in this manner. |
Attachment 1: P1070570.JPG
|
|
Attachment 2: P1070568.JPG
|
|
4563
|
Mon Apr 25 11:23:41 2011 |
Alastair | Bureaucracy | Computers | wiki? |
40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it. Is there some ongoing problem?

|
4564
|
Mon Apr 25 11:58:37 2011 |
Jamie | Bureaucracy | Computers | wiki? |
Quote: |
40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it. Is there some ongoing problem?
|
There was an email from Dave Barker about this. They had to reorganize the DNS at LHO. The URL that should be used is: http://blue.ligo-wa.caltech.edu:8000/40m |
4565
|
Mon Apr 25 12:55:19 2011 |
Jenne | Bureaucracy | Computers | wiki? |
Quote: |
Quote: |
40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it. Is there some ongoing problem?
|
There was an email from Dave Barker about this. They had to reorganize the DNS at LHO. The URL that should be used is: http://blue.ligo-wa.caltech.edu:8000/40m
|
Nope. I know I had the right address, and it was down for me too all weekend. It's better now though. blue.ligo-wa.caltech.edu was up though. |
4566
|
Mon Apr 25 12:55:35 2011 |
Alastair | Bureaucracy | Computers | wiki? |
Quote: |
Quote: |
40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it. Is there some ongoing problem?
|
There was an email from Dave Barker about this. They had to reorganize the DNS at LHO. The URL that should be used is: http://blue.ligo-wa.caltech.edu:8000/40m
|
Thanks Jamie, I've updated the links from the ATF wiki to reflect this. |
4603
|
Tue May 3 00:44:02 2011 |
Koji | Configuration | Computers | Martian WIreless Bridge |
The Martian wireless bridge has the ethernet cable inserted in the wrong connector.
It should be inserted to one of the four port. Not in the "INTERNET" connector.
Once the connector has been changed, the martian net as well as the internet became accessible from the laptops. |
4642
|
Thu May 5 15:26:52 2011 |
Leo Singer | Configuration | Computers | 'glue' installed on some control room computers |
I installed 'glue' on Rossa, Allegra, and Rosalba. This is a Python module that includes a facility for LIGO_LW XML files. Oddly, I couldn't find the glue package on Pianosa. |
4712
|
Fri May 13 14:54:20 2011 |
Leo Singer | Update | Computers | Diaggui fixed on pianosa |
I fixed diaggui on pianosa. Previously, it was not able to start because it depended on libreadline5, whereas Ubuntu distributed libreadline6. Now pianosa has both libreadline5 and libreadline6, so diaggui works. |
4784
|
Fri Jun 3 18:12:03 2011 |
steve | Update | Computers | no PEM channels |
AA filter box was removed and modified at 1Y7 today. The -5V power supply was current limited when I plugged it back in. It was removed for medical attention.
NO PEM channels available! because of this.
|
4789
|
Mon Jun 6 17:28:31 2011 |
steve | Update | Computers | still, no PEM channels |
Quote: |
AA filter box was removed and modified at 1Y7 today. The -5V power supply was current limited when I plugged it back in. It was removed for medical attention.
NO PEM channels available! because of this.
|
D68L8EX-850Hz filter chips were removed and bypassed-shorted as Rana's entry on March 17, 2006 in old elog.
This unit is still has a short somewhere. |
Attachment 1: P1070846.JPG
|
|
4866
|
Thu Jun 23 10:35:12 2011 |
steve | Update | Computers | old computers leaving the lab |
Rod Luna picked up these computers for Larry Wallace yesterday: Dell Inspiron 530, Dell Dimension 4600 and SunBlade 1000 |
Attachment 1: P1070905.JPG
|
|
Attachment 2: P1070904.JPG
|
|
Attachment 3: blade1000.JPG
|
|
4897
|
Tue Jun 28 11:25:56 2011 |
Alastair | Bureaucracy | Computers | restarted elog |
The manual instructions on the 40m wiki for restarting wouldn't work. I killed the process okay, but then I got an error saying it "couldn't bind to port 8080, please try again using -p to select port". The automated script worked though. |
4982
|
Mon Jul 18 14:39:53 2011 |
Jenne | Update | Computers | LSC PD chans acquired |
There's too much tromping around, so I'm not going to actually measure PRC length right now, but I did set some channels to be acquired (POPDC, POXDC, POYDC) in addition to ASDC which was already acquired, so that I can look at the resonance fringes when I sweep the ABSL laser (hopefully later tonight....) |
4991
|
Tue Jul 19 20:36:08 2011 |
rana | Update | Computers | VirtualBox + Windows 7 on rossa |
I installed Virtual Box on rossa. Then I put Windows 7 in there and am now installing Altium.
You can run Windows on rossa by just clicking Applications -> System Tools -> Virtual Box. |
5002
|
Wed Jul 20 17:43:33 2011 |
suresh | Update | Computers | restarted the frame builder |
I restarted the frame builder in the last 15mins.
I was making a change to a DAC channel in the C1IOO model. |
5058
|
Thu Jul 28 21:52:40 2011 |
rana | Update | Computers | another attempt to use pianosa |
- Pianosa doesn't cache the SVN pwds so you need to re-enter at each SVN up or commit. This is different from the rest of our workstations. We need to determine what behavior we want.
- Tried to use the netGPIB scripts:
pianosa:gpib 0> ./readSR785.csh rb2
rb2
netgpibdata.py: Command not found. |
5184
|
Thu Aug 11 08:29:28 2011 |
steve | Update | Computers | dataviewer at Rosalba |
I'm having this problem with DTV every morning at Rosalba only. It wants to start with a negative GPS time and it can not connect to the frame builder.
Normally after a few time of starting it, it will work. |
Attachment 1: gpsfmb.png
|
|
5379
|
Sat Sep 10 18:52:45 2011 |
rana | Update | Computers | conlog getting filled up |
One of the reasons that conlog seems so slow lately is that its been writing 100's of MB of .log files every day since early summer. It looks like the people who have been working on the mdl builds have not been properly adjusting the conlog channel lists. When this is not done conlog just gets filled up with non-control channels like OUT, OUTPUT, OUTMON, etc.
Peter Shawhan has supplied us with many scripts in the conlog directory to clean up these bloated files and fix the channel list. |
5548
|
Mon Sep 26 17:49:21 2011 |
Jenne | Update | Computers | We now have BURT restore for slow channels |
Koji and Suresh found that there have not been any autoburt snapshots taken of slow channels since ~December 13th 2010. Not good!
We have found an elog from Joe talking about autoburt changes from that day: elog 4046
Joe pointed all of the autoburt stuff to the new directory system, so it now decides to take a snapshot of every system in the *new* target directory. This means, since all of the aux things were left in the *old* target directory that none of them were getting snapshots taken. I have added the old target path back to the autoburt cron file so that every hour it will search through both old and new target directories and take snapshots of everything in both.
So, the systems which will now once again have autoburt snapshots taken are the following:
c1aux
c1auxex
c1auxey
c1dcuepics
c1iool0
c1iscaux
c1iscaux2
c1iscepics
c1losepics
c1omcepics
c1psl
c1susaux
c1vac1
c1vac2
I moved some old stuff (and especially things which would conflict with the new stuff) to the old target directory/oldfe/ : c1ass, c1assepics, c1susvme1, c1susvme2, c1sosvme, c1iovme.
The following systems don't have an autoburt.req file, so don't get snapshots: c0daqawg, c1daqctrl, c1dcu1, c1iscex, c1iscey. If any of these need autoburts, we should create them.
All the new systems in the new target directory still have their autoburts working.
The first test of this will be in a few minutes, at 18:07:00 Pacific during the regular cron job. Hopefully nothing crashes.... |
5552
|
Mon Sep 26 22:40:41 2011 |
Jenne | Update | Computers | We now have BURT restore for slow channels |
[Jenne, Koji]
After much Perl-learning and a few iterations, we have fixed the burt restore script, so that it actually does the slow channels. We have so far had one successful run, at 22:25, and the regular cron job should start doing the slow channels as of 23:07. |
5558
|
Tue Sep 27 15:33:03 2011 |
Jenne | Update | Computers | Making models, wreaking havoc |
[Jenne, Mirko, Den]
We have entered into an adventure in model compiling. What follows is a stream-of-consciousness report of what the hell we're doing, so Jamie can figure it out and fix it if everything goes to hell.
Note that for the first part of things, we have used a new version of the Adaptive XFCODE, which Mirko and Den modified last night to be able to handle multiple control signal inputs.
On c1lsc, make uninstall-daq-c1oaf , make clean-c1oaf , make c1oaf .
***ERROR: The following IPCx RECEIVER module(s) not found in the file /opt/rtcds/caltech/c1/chans/ipc/C1.ipc:
C1:RFM_OAF_MCL
On c1sus, make uninstall-daq-c1sus , make clean-c1sus , make c1sus . (This was an accident. I should have been making c1rfm. Oops.) Then make install-c1sus . It looks like this automatically did make install-daq-c1sus and make install-screens-c1sus, so I'm not doing those.
On c1sus, make uninstall-daq-c1rfm , make clean-c1rfm, make c1rf m.
***ERROR: The following IPCx RECEIVER module(s) not found in the file /opt/rtcds/caltech/c1/chans/ipc/C1.ipc:
C1:IOO-RFM_MCL
On c1ioo, make uninstall-daq-c1ioo , make clean-c1ioo, make c1ioo. No errors.
On c1lsc, make c1oaf . Here's some of the ouptut, with some of the error stuff:
: warning: ISO C90 forbids mixed declarations and code
/opt/rtcds/caltech/c1/core/branches/branch-2.1/src/fe/c1oaf/../controller.c:2954: warning: ISO C90 forbids mixed declarations and code
make[3]: *** [/opt/rtcds/caltech/c1/core/branches/branch-2.1/src/fe/c1oaf/c1oaffe.o] Error 1
make[2]: *** [_module_/opt/rtcds/caltech/c1/core/branches/branch-2.1/src/fe/c1oaf] Error 2
make[2]: Leaving directory `/usr/src/linux-2.6.34.1-cs'
make[1]: *** [default] Error 2
make[1]: Leaving directory `/opt/rtcds/caltech/c1/core/branches/branch-2.1/src/fe/c1oaf'
make: *** [c1oaf] Error 2
Again on c1lsc, make clean-c1oaf, make c1oaf. Here are some things:
Warning: variable "sysnum" is used but not declared.
In file included from build/c1oafepics/c1oaf.i:38:
src/include/fmReadCoeff.h:4:1: warning: "NO_FM10GEN_C_CODE" redefined
<command-line>: warning: this is the location of the previous definition
build/c1oafepics/c1oaf.i:5156: warning: passing argument 2 of 'strcpy' discards qualifiers from pointer target type
/usr/include/string.h:127: note: expected 'const char * __restrict__' but argument is of type 'volatile char *'
/opt/rtcds/caltech/c1/core/branches/branch-2.1/src/fe/c1oaf/../../include/drv/inputFilterModule1.h:5: note: expected 'double *' but argument is of type 'long unsigned int *'
/opt/rtcds/caltech/c1/core/branches/branch-2.1/src/fe/c1oaf/../controller.c:2780: warning: ISO C90 forbids mixed declarations and code
make[3]: *** [/opt/rtcds/caltech/c1/core/branches/branch-2.1/src/fe/c1oaf/c1oaffe.o] Error 1
make[2]: *** [_module_/opt/rtcds/caltech/c1/core/branches/branch-2.1/src/fe/c1oaf] Error 2
make[1]: *** [default] Error 2
make: *** [c1oaf] Error 2
Again, on c1lsc, make clean-c1oaf, make c1oaf . More errors, pretty similar. Then we changed the name of the adaptive filtering code, so maybe it will work now? We had called the block "TOP_XFCODE", but that was the name of the old .c code. The block used to be called "XFCODE", in a subsystem "TOP". So now we named the .c code "ADAPT_XFCODE" since the block is "XFCODE", and the subsystem is "TOP".
Again, on c1lsc, make clean-c1oaf, make c1oaf . Errors, they look the same.
Mirko is now modifying c1oaf.mdl to look more like the old version, with only one control signal input, so that we can use the old XFCODE that has been around for years.
First, we completely took out the .c code entirely. Now the c1oaf.mdl is just signals and matricies, no c-code is called. We did make clean-c1oaf, make c1oaf , and pretty much all of the same errors are present.
We took out the buses, and did make clean-c1oaf, make c1oaf, and we got a whole lot of warnings, but no "Error 2"'s. This seems good. We're going to try replacing those buses with Muxes, and see how that goes.
Now we're going to try to install the c1oaf, because maybe all the errors and shit we're seeing is just useless crap, and there aren't actually problems...here we go!
That seemed to work, and the c1oaf model on the GDS status screen seems happy. Numbers are moving around, which is my only current diagnostic.
Okay, now Mirko is going back to the full, new c1oaf, but replacing the Buses with Muxes.
Did a make clean-c1oaf, make c1oaf, got errors again.
Once again removed the .c code. Just put in a matrix instead. Did make clean-c1oaf, make c1oaf. No errors.
Den did a reorganization of the .c code, and we put it back in to the simulink model. Trying again the making stuff. Fail..Basically the same errors as before.
Next up: Putting in .c-code, but something which basically does nothing. Just defines all the outs as zeros. Make stuff. Still had problems, same errors. Grrrr, argh.
Found the RCG manual: T080135-v4. In it, when talking about including c-code, it had an example of totally simple code. We tried out their version of simple code, and it worked. No errors! Now to figure out what is same and different between our simple code and theirs.
PUT THE RIGHT STUFF in the Block Properties for the c-code, including name of the .c file, and path to the .c file. This is critical!! Now we can make some of our simple versions work, but not all. We're slowly increasing complexity of our c-code...
At some point in the last hour, I tried a make install-c1oaf, and then checked the screens, and they all had bad white boxes. So even though the model seemed to compile (at one point), the channels and screens aren't happy yet. But that's really a project for after the code compiles happily.
Okay, some progress was made to get the c-code running, and compiling, but it's not all there yet. We're putting in a simple, useless version of the c-code so we can try compiling everything else.
Everything is compiled, installed, there are no red lights on the GDS_STATUS screen. All seems okay for locking for tonight.
|
5565
|
Wed Sep 28 14:15:40 2011 |
Jenne | Update | Computers | Edits to c1pem, c1oaf |
[Mirko, Jenne]
Mirko edited c1pem to have some new BLRMS channels.
I added a master Enable switch to the c1oaf.
Both were compiled, and restarted. fb rebooted. All looks okay (hopefully) |
5568
|
Wed Sep 28 21:23:23 2011 |
Mirko | Update | Computers | ISCY FE network card / cable not ok |
[Mirko,Jenne]
We discovered that the left network cable is not rigidly connected to the back of the ISCY FE computer. You can easily pull it out a mm disconnecting it. It should click rigidly in place. Not clear if it's the cable or the network card. |
5569
|
Wed Sep 28 21:28:34 2011 |
Mirko | Update | Computers | Torturing control computers. Fine again now |
[Mirko, Jenne]
We tried to run an extended version of Matt's LMS adaptive filter c-code. We got the extension to compile separately in gcc first. Then after some tweaking of the code we could make-install c1oaf with the c-code.
This killed c1lsc (the FE computer running c1oaf). Not responding to ssh or even pings. We replaced the bad c-code with harmless code, then reset c1lsc via the hardware button. While looking for c1lsc we discovered the problem with c1iscy network card (see previous entry).
After c1lsc reboot, restart of the FB, and a BURT restore not ok yet |
5571
|
Wed Sep 28 22:25:25 2011 |
Jenne | Update | Computers | Torturing control computers. Fine again now |
Quote: |
[Mirko, Jenne]
We tried to run an extended version of Matt's LMS adaptive filter c-code. We got the extension to compile separately in gcc first. Then after some tweaking of the code we could make-install c1oaf with the c-code.
This killed c1lsc (the FE computer running c1oaf). Not responding to ssh or even pings. We replaced the bad c-code with harmless code, then reset c1lsc via the hardware button. While looking for c1lsc we discovered the problem with c1iscy network card (see previous entry).
After c1lsc reboot, restart of the FB, and a BURT restore not ok yet
|
We had lots of trouble damping the Vertex Suspensions after this craziness. A symptom was that even if all of the damping servos on an optic were OFF, and I turned the watchdog on (LSC is disabled, so no OAF siganls, no LSC signals), there were signals going to the coils.
We did a reboot of the c1sus computer, did another BURT restore, and the optics started damping happily. Burt restore, at least for c1susepics and c1mcsepics, seems to not be happening automatically. I thought it was supposed to happen when the model was restarted?
Things now appear to be normal again. |
5573
|
Thu Sep 29 00:16:35 2011 |
Den | Update | Computers | Segmentation fault fixed. |
The OAF c-code crashed because of the segmentation fault. We've created arrays of static variables
static int pst[nDOF];
static int isFirst[nDOF];
static adaptive_filter_state state[nDOF];
an tried to give in the to the ITERATE - function their current values
datOut[i] = ITERATE(iterateDatIn, iterateNIn, pst[i], isFirst[i], state[i]);
ITERATE function was declared as
double ITERATE(double *datIn, int nIn, int pst, int isFirst, adaptive_filter_state state) {}
Here the segmentation fault comes out. Static variables are meant to be created only once but here in the function ITERATE we try to create them once again in a local form, because we give the variables by their values.
Instead, we must give the variables by their pointer, then the variables won't be created again during the function call and will be changed in the function.
datOut[i] = ITERATE(iterateDatIn, iterateNIn, &pst[i], &isFirst[i], &state[i]);
double ITERATE(double *datIn, int nIn, int *pst_s, int *isFirst_s, adaptive_filter_state *state_s)
In order not to change significantly Matt's code and use his notations we can add in the ITERATE function
int pst = *pst_s;
int isFirst = *isFirst_s;
static adaptive_filter_state state;
state = *state_s;
..................................Matt's code.........................................
*pst_s = pst;
*isFirst_s = isFirst;
*state_s = state;
I've tested the program, now it does not give any segmentation faults and conserves memory that it uses. |
5577
|
Thu Sep 29 20:37:12 2011 |
Mirko | Update | Computers | New c1oaf c-code: Breaking in new way |
[Mirko, Jenne]
Programmed a new implementation of the LMS in C. Compiles fine in gcc. The full code still kills c1lsc computer. Tried to go through the code uncommenting more and more. Not perfect in reproducability. The attached version should compile and keep c1oaf running, but not actually produce an adaptive filter. At some point the code just keeps c1oaf from starting up. Leaves the c1lsc computer in working order. At some point I got error messages like ..................................................................
CA.Client.Exception...............................................
Warning: "Identical process variable names on multiple servers"
Context: "Channel: "C1:OAF-ADAPT_CORR_BS_Name08", Connecting to: 192.168.113.62:50970, Ignored: c1lsc:34533"
Source File: ../cac.cpp line 1209
Current Time: Thu Sep 29 2011 19:18:17.219208306
..................................................................
CA.Client.Exception...............................................
Warning: "Identical process variable names on multiple servers"
Context: "Channel: "C1:OAF-ADAPT_CORR_BS_Name09", Connecting to: 192.168.113.62:50970, Ignored: c1lsc:34533"
Source File: ../cac.cpp line 1209
Current Time: Thu Sep 29 2011 19:18:17.225999915
..................................................................
CA.Client.Exception...............................................
Warning: "Identical process variable names on multiple servers"
Context: "Channel: "C1:OAF-ADAPT_CORR_ETMX_SW1R", Connecting to: 192.168.113.62:50970, Ignored: c1lsc:34533"
Source File: ../cac.cpp line 1209
Current Time: Thu Sep 29 2011 19:18:17.243037042
..................................................................
This usually indicates that there are multiple carepeater running. Didn't find where that would be. After rebooting c1lsc and c1sus a couple of times everything seems fine. |
Attachment 1: ADAPT_XFCODE11-09-29---20-12.c
|
// LMS algorithm adaptive filtering for the Caltech 40m -- Sept. 2011 by M. Prijatelj
#define nDOF 8
#define nWIT 21
#define nTAPS 1000
void ADAPT_XFCODE(double *in, int inSize, double *out, int outSize) {
//First the DOFs and their switches
//int nDOF=8;
... 136 more lines ...
|
5733
|
Tue Oct 25 01:19:17 2011 |
Suresh | Update | Computers | fb restarted and c1ioo model committed to svn |
When I installed the new model I restarted the fb between 1 and 1:30 AM PDT Oct 25, 2011 |
5757
|
Fri Oct 28 15:33:06 2011 |
Jenne | Update | Computers | Nifty screen generator |
Suresh showed me a cool script that Mirko made, but didn't elog about.
You tell the script what filter banks you want, and it creates a screen for each with a bunch of different filter module display formats. Then you can copy the format you like into the actual screen you're modifying.
Currently PEM, LSC and IOO (and maybe others?) have "fmX" folders inside their medm/c1.../master folders. For each subsystem, we need to copy this folder, and modify the generic .adl file so that it puts in the correct subsystem letters. Once this is done, you can just run the generateFMscreens.py after putting in your filter bank names. |
5758
|
Fri Oct 28 15:45:52 2011 |
Mirko | Update | Computers | Nifty screen generator |
Quote: |
Suresh showed me a cool script that Mirko made, but didn't elog about.
You tell the script what filter banks you want, and it creates a screen for each with a bunch of different filter module display formats. Then you can copy the format you like into the actual screen you're modifying.
Currently PEM, LSC and IOO (and maybe others?) have "fmX" folders inside their medm/c1.../master folders. For each subsystem, we need to copy this folder, and modify the generic .adl file so that it puts in the correct subsystem letters. Once this is done, you can just run the generateFMscreens.py after putting in your filter bank names.
|
Wasn"t me. |
5778
|
Tue Nov 1 18:45:48 2011 |
Jenne | Update | Computers | Allegra's screens |
I was trying to give Allegra a second head, and it didn't quite work. It's still in progress. Steve, you might not like how I've 'mounted' the second monitor, so we can talk about something that might work tomorrow. |
5780
|
Tue Nov 1 23:13:28 2011 |
Zach | Update | Computers | NDS2 channel files |
I did some messing around with the NDS2 config and channel files and things seem to be working as expected... for now. SENSOR channel data can be acquired for all sensors on all hanging optics.
What I did:
- NDS2 gets its channel lists from .../users/jzweizig/nds2-mafalda/nds2.conf, which is called in the start-nds2 script. Within this, there are channel.file lines that specify which channels are available for raw and trend data. The four files that were listed were:
- C-R-raw-channel_list.txt
- C-M-ChanList.txt
- C-T-ChanLIst.txt
- C-R-online-channel_list.txt (this one was listed after a hashed line, which was suspicous---see below)
- I noticed that a grep for SENSOR only returned lines for non-MC mirrors in both "R" files
- I also noticed that calling NDS2_GetChannels('mafalda.martian:31200') did not return any non-suffixed (i.e., raw) channel names for MCx_SENSOR channels, while non-MC SENSOR channels each had two non-suffixed listings. I thought this was strange.
- I manually added the line "C1:SUS-MC1_SENSOR_UL 0 real_4 2048 C-R" to one of the "R" channel files, then restarted the NDS2 server, and that channel was still not served. I figured that the second "R" channel file might have been left in the config file as a mistake, so I commented it out, restarted the NDS2 server, and was able to get MC1_SENSOR_UL data. I have left the comment-out there, with a signed EDIT.
- Wary of (and too lazy to) manually add lines for all 5 sensors for each MC mirror, I decided to try generating a channel file using the most recent .gwf file in the frames, as indicated in Joe and John's elog post. To do this, while in .../nds2-mafalda/, I ran:
- /cvs/cds/caltech/users/jzweizig/nds2-server/bin/buildChannelList /frames/full/10042/C-R-1004246528-16.gwf > C-R-raw-channel_list.txt
- A grep for SENSOR in the new C-R-raw-channel_list.txt now returned lines for all MC mirror sensors... BUT NOT FOR ETMY(?!). I tried some slightly older .gwf files (all from today), but the ETMY files never showed up. I had no choice but to enter them manually. Another odd thing is that the channel file generated this way seems to be fairly jumbled up, in the sense that there is no clear top-town order (e.g. SUS-BS_blah then SUS-ETMX_blah). Instead, some SUS-BS channels are here, some are after SUS-ETMX or SUS-PRM channels, etc. Look at the file to know what I mean.
- The original raw channel file is there as C-R-raw-channel_list.txt.bak.1004247481.
In any case, as I said, everything appears to be working now, but as soon as we try to generate a new channel file using the prescribed means, there will inevitably be channels omitted. Someone who knows more than me should get to the bottom of this and wiki a strict, detailed procedure for how this is to be done. |
5830
|
Mon Nov 7 14:50:19 2011 |
Jenne | Update | Computers | ISCEX is having a bad day |
I clicked on the FE status screen, just to check on things, and everything on the c1iscex section was red (the IOP and c1scx). Upon deciding that was probably a bad thing, I did a soft reboot from the control room. Now the IOP says "NO SYNC", and the c1scx status thing is totally frozen.
I have sent Jamie a whiny email. He promises to be here soon to fix it.
|