ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
3677
|
Fri Oct 8 10:38:03 2010 |
steve | Configuration | SAFETY | 2W laser shutter is closed |
|
 |
1872
|
Mon Aug 10 14:58:01 2009 |
Jenne | Update | PEM | 2nd set of Guralp channels plugged into ADCU | The second set of Guralp channels is now
plugged into the PEM ADCU, into channels
which are confirmed to be working. |
|
1882
|
Mon Aug 10 18:12:25 2009 |
Jenne | Update | PEM | 2nd set of Guralp channels plugged into ADCU |
|
|
5970
|
Mon Nov 21 16:08:04 2011 |
kiwamu | Update | Green Locking | 2nd trial of Y arm ALS noise budget : broad band noise gone |
|
|
9549
|
Mon Jan 13 11:08:48 2014 |
Steve | Update | PSL | 3 good days of IOO pointing | Three good days of IOO pointing:
Friday, Sat and Sun What
was changed? May be the clamping on |
|
15929
|
Wed Mar 17 10:52:48 2021 |
Jordan | Update | SUS | 3" Ring Adpater for SOS | I have added a .1", 45deg chamfer
to the bottom of the adapter ring. This was
added for a new placement of the eq stops, |
    |
8526
|
Fri May 3 08:55:55 2013 |
Steve | Update | PEM | 3.2 M earthquake | |
 |
580
|
Thu Jun 26 22:08:33 2008 |
Jenne | Update | Electronics | 3.7MHz bandstop filter in MC Servo | The 3.7MHz elliptical bandstop filter that
I made during my SURF summer is now installed
in the MC servo loop to reduce the noise |
   |
1433
|
Thu Mar 26 04:27:26 2009 |
Yoichi | Update | Locking | 3.8kHz peak as a function of the arm power | During the power ramp-up, I actuated CARM
using ETMs and measured the transfer functions
to the PO_DC at several arm powers.
|
|
1450
|
Wed Apr 1 16:14:36 2009 |
Yoichi | Update | Locking | 3.8kHz peak does not change with SRC offset | Yoichi, Peter
We suspected that maybe the 3.8kHz peak is |
|
1449
|
Wed Apr 1 15:47:48 2009 |
Yoichi | Update | Locking | 3.8kHz peak looks like a real optical response of the interferometer | Yoichi, Peter
To see where the 3.8kHz peak comes from, |
 |
9115
|
Fri Sep 6 09:27:10 2013 |
Steve | Update | VAC | 31 days after pumpdown |
|
|
4151
|
Thu Jan 13 16:34:02 2011 |
josephb | Update | Computers | 32 bit matlab updated | There
was a problem with running the webview report
generator in matlab on Mafalada. It |
|
2126
|
Tue Oct 20 16:35:24 2009 |
rob | Configuration | LSC | 33MHz Mod depth | The 33MHz mod depth is now controlled by
the OMC (C1:OMC-SPARE_DAC_CH_15). The
setting to give us the same modulation depth |
|
11010
|
Thu Feb 12 03:43:54 2015 |
ericq | Update | LSC | 3F PRMI at zero ALS CARM | I have been able to recover the ability
to sit at zero CARM offset while the PRMI
is locked on RELF33 and CARM/DARM are on |
|
10668
|
Wed Nov 5 01:58:54 2014 |
ericq | Update | LSC | 3F RFPD RF spectra | Given the checkout of the aLIGO BBPDs happening
(aLOG
link), wherein the PDs were acting funny, |
  |
10669
|
Wed Nov 5 11:09:44 2014 |
Koji | Update | LSC | 3F RFPD RF spectra | If you look at the intermodulation at 14
(4+10) and 16 (6+10), 15 (5+10) would make
any problem, thanks to the notch at 1f and |
|
10673
|
Wed Nov 5 22:25:42 2014 |
ericq | Update | LSC | 3F RFPD RF spectra |
Now that I have followed the chain,
the PD signal is indeed being amplified at |
|
10675
|
Thu Nov 6 01:58:55 2014 |
Koji | Update | LSC | 3F RFPD RF spectra | Where is the PD out spectrum measured with
the coupler??? |
|
10679
|
Thu Nov 6 11:49:58 2014 |
ericq | Update | LSC | 3F RFPD RF spectra |
|
|
10682
|
Thu Nov 6 14:41:49 2014 |
Koij | Update | LSC | 3F RFPD RF spectra | That's not what I'm asking.
Also
additional cables are left connected to the |
|
10683
|
Fri Nov 7 02:21:12 2014 |
ericq | Update | LSC | 3F RFPD RF spectra |
After some enlightening conversation
with Koji, we figured that the RF amplifier |
|
10685
|
Fri Nov 7 14:41:18 2014 |
ericq | Update | LSC | 3F RFPD RF spectra |
|
 |
10686
|
Fri Nov 7 16:15:53 2014 |
Jenne | Update | LSC | 3F RFPD RF spectra | I have found an SHP-150, but no SHP-175's
(also, several 200's, and a couple of 500's).
Why do you say the SHP-150 isn't |
|
10689
|
Sat Nov 8 11:35:05 2014 |
rana | Update | LSC | 3F RFPD RF spectra |
I think 'saturation'
here is a misleading term to think about. |
|
10692
|
Mon Nov 10 18:11:57 2014 |
ericq | Update | LSC | 3F RFPD RF spectra | Jenne and I measured the situation
using a SHP-150 directly attached to the
REFL165 RF output, and at first glance, the |
|
10696
|
Tue Nov 11 03:48:46 2014 |
Jenne | Update | LSC | 3f DRMI | I was
able to lock the DRMI on 3f signals this
evening, although the loops are not stable, |
 |
10698
|
Tue Nov 11 21:41:09 2014 |
Koji | Update | LSC | 3f DRMI sensing mat | Sensing
matrix calculation using DTT + Matlab
Note: If the signal phase is, for |
|
10701
|
Wed Nov 12 03:22:23 2014 |
Jenne | Update | LSC | 3f DRMI sensing mat | Koji pointed out something to me that I
think he had told me ages ago, and Rana alluded
to last night: Since I'm not tuning |
8x |
5401
|
Wed Sep 14 01:19:20 2011 |
Anamaria | Configuration | LSC | 3f PD Install in Progress | I have reconfigured the refl beam path
on the AP table to include REFL33 and REFL165.
Would be done if we hadn't prepared P BSs |
|
9976
|
Tue May 20 16:48:52 2014 |
ericq | Update | LSC | 3f Stability | So, I really should have done this as soon
as Manasa
measured the arm lengths... I've |
 |
9977
|
Tue May 20 22:42:28 2014 |
ericq | Update | LSC | 3f Stability | Here's the angles of MICH and PRCL
from the my earlier plot by themselves; this
shows that the individual demod angles in |
|
5377
|
Sat Sep 10 14:55:28 2011 |
Keiko | Update | LSC | 3f demodulation board check | To
check the demodulation boards for REFL33
and REFL165, a long cable from ETMY (SUS-ETMY-SDCOIL-EXT |
|
5378
|
Sat Sep 10 16:10:42 2011 |
Keiko | Update | LSC | 3f demodulation board check | There is a LP filter just after the RF
input of an demodulation board (its schematic
can be found as D990511-00-C on DCC). I have |
|
5380
|
Sat Sep 10 18:57:52 2011 |
Keiko | Update | LSC | 3f demodulation board check | The
phase delay due to the RF input filter on
the demodulation board will not bother the |
|
5385
|
Sun Sep 11 22:36:32 2011 |
Keiko | Update | LSC | 3f demodulation board check | Filters
at the RF inputs of REFL33 and REFL165 demodulation
boards were measured again. The filters will |
 |
5386
|
Mon Sep 12 13:24:07 2011 |
Keiko | Update | LSC | 3f demodulation board check | I also quickly
checked the orthogonality of the demodulation
board for REFL33 and REFL165 using function generators |
|
5387
|
Mon Sep 12 16:27:01 2011 |
Keiko | Update | LSC | 3f demodulation board check | Wait. I am checking the whitening filters
of the 33 and 165 demodulation boards.
Also, |
|
5388
|
Mon Sep 12 18:40:35 2011 |
Keiko | Update | LSC | 3f demodulation board check | LSC-REFL33-I-IN1(IN2, OUT) and |
|
5394
|
Tue Sep 13 15:00:25 2011 |
Keiko | Update | LSC | 3f demodulation board check | Whitening filters for the REFL33 &
165 demodulated channels were measured and
confirmed that they are working. They can |
 |
5399
|
Tue Sep 13 23:08:51 2011 |
Keiko | Update | LSC | 3f demodulation board check | Keiko,
Jamie , Kiwamu
The |
 |
5412
|
Thu Sep 15 01:06:20 2011 |
Keiko | Update | LSC | 3f demodulation board check | In addition to REFL 33 ans 165, I checked
the orthogonality for the other existing
three channels. |
|
5440
|
Fri Sep 16 21:26:12 2011 |
Keiko | Update | LSC | 3f demodulation board check | The demodulation
phases and gains for the all existing channels, |
|
1354
|
Wed Mar 4 12:38:07 2009 |
Alberto | Update | Computer Scripts / Programs | 3f locking simulations | I simulated the REFL signals demodulated
at the differential frequencies of the sidebands
(f2-f1), at their summed frequencies (f2+f1). |
  |
11005
|
Wed Feb 11 18:11:46 2015 |
Koji | Summary | LSC | 3f modulation cancellation | 33MHz sidebands can be elliminated by careful
choice of the modulation depths and the relative
phase between the modulation signals. |
|
11019
|
Thu Feb 12 23:47:45 2015 |
Koji | Update | LSC | 3f modulation cancellation | - I built another beat setup on the PSL
table at the South East side of the table.
- The main beam is not touched, no |
|
11028
|
Sat Feb 14 00:48:13 2015 |
Koji | Update | LSC | 3f modulation cancellation | [SUCCESS]
The 3f sideband cancellation seemed worked
nicely. |
|
11029
|
Sat Feb 14 19:54:04 2015 |
Koji | Summary | LSC | 3f modulation cancellation | Optical
Setup
[Attachment 1] |
  |
11031
|
Sat Feb 14 20:37:51 2015 |
Koji | Summary | LSC | 3f modulation cancellation | Experimental
results
- PD response [Attachment |
   |
6929
|
Fri Jul 6 09:27:40 2012 |
steve | Update | VAC | 4 days at atm | I'm looking for some movement indicators
of the vent-pump down events.
|
|