40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 89 of 170  Not logged in ELOG logo
Entry  Mon Nov 28 15:00:20 2011, kiwamu, Update, Green Locking, Y arm ALS engaged 

    
        
            Quote from #5894
        
        
        
   
              
Entry  Thu Nov 24 20:22:42 2011, Mirko, Update, IOO, F2A filter for MC UpperCoils.pdfLowerCoils.pdf
I calculated the F2A filters for the input mode cleaner optics as described in T010140-01-D eq (4). On Ranas recommendation I added an s/ ( w_0 * Q )
term to the numerator.
The used values are:
    Reply  Fri Nov 25 17:52:28 2011, rana, Update, IOO, F2A filter for MC 
Woo. Pretty crazy. The numerators should only be ~10% larger than the denominator below 1 Hz. Let's try again.
       Reply  Fri Nov 25 23:25:24 2011, Mirko, Update, IOO, F2A filter for MC F2aForMCcomparedToBS.pdf


    
        
            Quote:
        
        
            
            Woo. Pretty crazy. The numerators should only be ~10% larger than the denominator below 1 Hz. Let's try again.
          Reply  Mon Nov 28 10:54:40 2011, rana, Update, SUS, F2A filter for MC 
Our approach to making the F2A or F2P filters for the MC is to use the
measured resonant frequencies and then calculating the appropriate mechanical dimensions of each suspension. This is basically because we don't have optical
levers with normal incidence on these optics, but the method should be fine.
Entry  Sat Nov 26 19:37:12 2011, Den, Update, General, foton files 
 I've checked foton files for small numbers. There are several other filters besides "Cheby"
that are presented with small numbers. For example, "BTW0.01" in the LOCKING_Q, LOCKING_I
modules,  "SeisDaytime"  in the SUP_MC3_SP_NOISE and others. The output of the
Entry  Tue Nov 22 18:42:10 2011, kiwamu, Summary, Green Locking, Some issues on the Y end green PDH locking 
[Rana / Kiwamu]
 As a part of the ALS noise budgeting we took a look at the Y end PDH setup to see if we are limited
by an effect from the Amplitude Modulation (AM).
    Reply  Wed Nov 23 00:00:53 2011, Zach, Summary, Green Locking, Some issues on the Y end green PDH locking 


    
        
            Quote:
        
        
            

           (AM transfer function)
    Reply  Sat Nov 26 19:07:40 2011, kiwamu, Summary, Green Locking, AM trnasfer function of the Y end laser with doublin crystal AMTF_lightwave.pngAMTF_cailbrated.bod.zip


    
        
            Quote from #5980
        
    
   
            
             As a part
Entry  Sat Nov 26 07:18:11 2011, Suresh, Update, IOO, MC WFS related changes to c1ioo model WFS_err_20111127.pngcioo_20111127.png
What I did:
    I have changed the c1ioo model such that the signals which are demodulated in the WFS lockin (the SIG inputs) are now picked
up just after the input matrix.  This permits us to put a notch filter at the excitation frequency into the WFS servo filterbanks and thus prevent
Entry  Fri Nov 25 18:45:31 2011, Den, Rana, Summary, SUS, Excess Noise in Digital Filtering FiltNoise.png
We are now trying to understand why the coherence between SUS-X_SUSPOS_IN1 and SUS-X_SUSPOS_OUT is lost below 1 Hz for X = MC1, MC2, MC3, BS, ITMX, ITMY,
ETMX, ETMY, SRM. It is OKEY only for PRM but the different filteres are used there. For PRM - 30:0.0 and Bounce Roll, for all others - 30:0.0 and Cheby.
The transfer functions between these two signals plotted in foton and fft tools are also not the same.
    Reply  Fri Nov 25 19:45:36 2011, Mirco, Den, Summary, SUS, Excess Noise in Digital Filtering sus_coh-crop.pdflsc_coh-crop.pdf


    
        
            Quote:
        
        
            
            We are now trying to understand why the coherence between SUS-X_SUSPOS_IN1 and SUS-X_SUSPOS_OUT is lost below 1 Hz
Entry  Fri Nov 25 12:46:13 2011, Mirko, Update, WienerFiltering, Wiener filtering tryout WienerFiltering.pdf
Tried the wiener filter with the TF from p.5900
Tried it out with the TFs from p.5900:
Entry  Thu Nov 24 14:42:57 2011, Koji, Update, elog, elogd gained an immunity to googlebot 
I modified elogd.c as shown below in order not to allow to display all of the entries at once by specifying page number "0".
After this modification, elog seems to have survived 66 times of attacks by googlebots.
==============================
    Reply  Thu Nov 24 15:48:27 2011, Illustrator, Update, elog, elogd gained an immunity to googlebot elog_mario.pnggolden-monkey.jpeg

Entry  Thu Nov 24 15:27:15 2011, kiwamu, Update, CDS, c1iscey hardware rebooted 
The c1iscey machine crashed around 1:00 AM last night and I did a hard-ware reboot by pressing a
button on the front panel of the machine.
After the reboot its been running okay so far.
The
crash happened after I pressed the "Diag Reset" button on the CDS status screen.
Entry  Thu Nov 24 14:05:10 2011, Koji, Update, PSL, HEPA@50% 
I left the HEPA at the 50% level @5AM, Nov 24
Entry  Wed Nov 23 18:28:09 2011, Koji, Update, IOO, RFAMPD channels / EOM monitor channels added to DAQ 
The following channels have been registered in c1iool0 database, and are now recorded by FB
C1:IOO-RFAMPD_11MHZ
C1:IOO-RFAMPD_29_5MHZ
    Reply  Thu Nov 24 05:10:00 2011, Koji, Update, IOO, RFAMPD channels / EOM monitor channels added to DAQ 
EOM TEMPMON and HEATER DRIVEMON have been hooked up to the following channels.

C1:IOO-EOM_TEMPMON
C1:IOO-EOM_HEATER_DRIVEMON 
       Reply  Thu Nov 24 10:27:07 2011, Jenne, Update, IOO, RFAMPD channels / EOM monitor channels added to DAQ EOM_temp_sense_heater_drive_schematic_withMONs.png
Here is a drawing of where the monitors are coming from:
          Reply  Thu Nov 24 12:45:12 2011, Zach, Update, IOO, RFAMPD channels / EOM monitor channels added to DAQ 
Jenne: The point you indicate for the heater
monitor is a virtual ground--it will be driven to zero by the circuit if it's functioning properly; the readout should be done at the input
             Reply  Thu Nov 24 13:54:31 2011, Koji, Update, IOO, RFAMPD channels / EOM monitor channels added to DAQ 
Those clips for the readouts were the ones who popped out. 
When I have restored the connections, I checked the schematic and the heater drive mon is clipped on the output side of the OP27.


    
        
            
Entry  Thu Nov 24 05:47:16 2011, Koji, Summary, IOO, Stochmon running 
Now stochmon for 11MHz and 55MHz is running. The calibration / noise measurement are going to be post later...
Entry  Thu Nov 24 02:23:43 2011, Koji, Summary, General, GPIB<->WIFI 
GPIB<->WIFI on Agilent Network Analyzer 4395A was broken.
The connection was fixed by replacing and configuring the LINKSYS bridge.
=======
Entry  Sun Nov 20 14:48:55 2011, kiwamu, Update, General, recovery from the power shutdown 
Recovery from the power shutdown
 - Turned on the raid disk of linux1.
 - Woke linux1 up. No fsck this time.
    Reply  Sun Nov 20 15:33:37 2011, rana, Update, General, recovery from the power shutdown 
 restarted Apache on Nodus for the SVN as per wiki instructions
    Reply  Wed Nov 23 22:58:33 2011, Koji, Update, General, c1iscaux2 is back (re: recovery from the power shutdown) 
Keying again did not help to solve the issue. I turned off the power at the back of the crate, and turn it on again. 
Then the key worked again.
c1iscaux2 is burtrestored and running fine now.
    Reply  Thu Nov 24 01:28:09 2011, kiwamu, Update, General, 1X8 sorensen came back 


    
        
            Quote from #5963
    
   
        
            
             - One of the Sorensens in 1X8 rack
Entry  Wed Nov 23 16:55:57 2011, Suresh, Update, IOO, MC realigned 
The PSL alignment into the MC was too poor for the autolocker to engage.  So retaining the last coil slider settings on the MC_Align screen that
Kiwamu wanted, I have realigned the PSL beam and recentered the beam on the WFS.
When the WFS_MASTER was burtrestored after the recent power shutdown, the values loaded into the output matrix were not optimal.  When we
Entry  Wed Nov 23 16:48:39 2011, Suresh, Update, General, cable cleanup 
[Koji Suresh]
As part of the general lab clean up we removed many unused BNC cables (long and short) from around the SP table.  We removed one very long
BNC cable which was connected on one side to an PEM input and not connected on the other side near the 1X2 rack..   There were several cables
Entry  Wed Nov 23 14:47:14 2011, Jenne, Configuration, Environment, AC in the IFO room was off 
I turned it back on, maybe around 11am?  Definitely a little while before the 12:30 meeting.
EDIT by KI:
 Sorry, it's me. I was checking if AC was doing something bad on the ALS noise.
Entry  Wed Nov 23 13:53:36 2011, Zach, Update, Green Locking, Sensor noise Yarm_ALS_2011Nov19_marked.png
The in-loop Y-Arm error signal looks equal to the beat note noise divided by the Y-Arm OL gain in the broadband-noise region (>20 Hz), which would be the case if the loop was dominated by sensor noise here.
I would re-check the Y-Arm dark noise, or at least check for coherence between the Y-Arm error signal
Entry  Wed Nov 23 02:34:28 2011, Mirko, Update, PEM, Seismic spectrum & Striptool SeismicSpectrum.pdf
The Striptool for the BLRMS seismic channels is running now. Channels are ( still ) recorded as slow EPICS channels.
A big peak in the 0.1 - 0.3Hz seismic region in both GUR1 and STS1 irritated us for a while. I added an extra LP filter @ 0.05Hz to the RMS_LP
modules.
Entry  Wed Nov 23 00:30:55 2011, Zach, Update, elog, sucks 
Tried the script 3 times and it didn't come back. Pkill'd and then scripted. That worked.
Entry  Wed Nov 23 00:30:14 2011, Zach, Update, RF System, EOM temperature controller trials 
[Jenne, Zach]
We did some testing of the prototype temperature controller. When I left it late last night, it was not working in conjunction with the real heater
and PT100 mounted to the EOM, but had been tested using simulated loads (a spare heater and a potentiometer for the RTD).
Entry  Tue Nov 22 20:45:21 2011, Mirko, Update, IOO, Measurement of the actuator matrix 
Tried measuring the actuator matrix for MC1.
With the watchdogs tripped I cut the loops for pos, pitch and yaw open just before the servos. Then I injected a fixed sine at 0.4Hz into the three
DOFs (suspos, suspit, susyaw) one by one, while looking into the error signal just before the servos.
Entry  Tue Nov 22 18:15:39 2011, jamie, Update, CDS, c1iscex ADC found dead. Replaced, c1iscex working again 
c1iscex has not been running for a couple of days (since the power shutdown at least). I was assuming that the problem was recurrence of the c1iscex
IO chassis issue from a couple weeks ago (5854).  However, upon investigation I found that the timing signals were all fine.  Instead, the
IOP was reporting that it was finding now ADC, even though there is one in the chassis.
Entry  Tue Nov 15 12:25:38 2011, kiwamu, Update, Green Locking, Y arm ALS : beat-note free run fluctuation noise_budget.png
Locking activity last night :
  The free run beat-note in 532 nm has been measured.
However I couldn't close the ALS loop somehow.
    Reply  Wed Nov 16 17:29:46 2011, kiwamu, Update, Green Locking, Some updates on the Y end green PDH Yarm_fluctuation.png

    
        
            Quote from #5894
        
        
        
   
             (Things to be done)
       Reply  Thu Nov 17 17:21:22 2011, kiwamu, Update, Green Locking, Y end green PDH servo : it's okay servoTF.pngservofilter.pngerr_suppression.png


    
        
            Quote from #5914
    
   
        
            
            So I have added an SR560 in the other input
          Reply  Fri Nov 18 11:28:39 2011, rana, Update, Green Locking, Y end green PDH servo : it's okay 


    
        
            Quote:
        
        
            

           
            
                
           
             Reply  Fri Nov 18 12:11:24 2011, Zach, Update, Green Locking, Y end green PDH servo : it's okay 


    
        
            Quote:
        
        
            

            
    Reply  Thu Nov 17 18:20:26 2011, kiwamu, Update, Green Locking, Y arm ALS : 1st trial of noise budget Yarm_ALS_2011Nov16.png
The noise budget on the Y arm ALS has begun.
Right now the fluctuation of the green beat-note seems mostly covered by unknown noise which is relatively
white.
       Reply  Mon Nov 21 16:08:04 2011, kiwamu, Update, Green Locking, 2nd trial of Y arm ALS noise budget : broad band noise gone Yarm_ALS_2011Nov19.png


    
        
            Quote from #5930
        
    
   
            
            Right now the fluctuation
          Reply  Tue Nov 22 15:18:18 2011, kiwamu, Update, Green Locking, broad band noise depends on the gain of Y green PDH. and comaprator broken 


    
        
            Quote from #5970
    
   
        
            
            Here is a plot of the latest noise : high
Entry  Tue Nov 22 14:39:50 2011, Jenne, Update, elog, Afternoon elog restart 
Gave the elog its afternoon / tea-time reboot, since it was hanging yet again.
Entry  Tue Nov 22 06:12:43 2011, Zach, Update, RF System, Prototype temperature controller refres1.pngrefres2.pngproto_temp_ctrl.pngschematic.png
Tonight I built a simpler version of what will be the new general-purpose
precision temperature controller. This one is built on a breadboard and will be used for RFAM testing at the 40m until a better version
is made. Some  differences between this version and the final one:
Entry  Tue Nov 22 04:02:47 2011, kiwamu, Update, IOO, changed MC alignment 
I have changed the MC2_YAW DC bias because the PZT1_YAW was railing.
I also realigned the steering mirrors in zig-zag path since the mode cleaner tended to resonate with higher order modes after I have changed the
MC2 bias.
Entry  Tue Nov 22 00:19:10 2011, kiwamu, Update, SUS, c1auxey hadware rebooted 
I found that the slow machine c1auxey, which controls and monitoring the ETMY suspension things, were
not responding.
The machine responded to ping but I wasn't able to telnet to it.
Entry  Mon Nov 21 17:07:34 2011, Mirko, Update, CDS, c1pem model dead 
For some reason C1PEM doesn't seem to work anymore after a recompilation. It did recompile fine. We just changed some channel / subsystem names.
Tried reverting to the svn version. Doesn't work. Reboot C1SUS also no good.
    Reply  Mon Nov 21 22:51:55 2011, Mirko, Update, CDS, c1pem model dead 


    
        
            Quote:
        
        
            
            For some reason C1PEM doesn't seem to work anymore after a recompilation. It did recompile fine. We just changed some
Entry  Sun Nov 20 15:11:09 2011, kiwamu, Update, IOO, RFAM monitoring test 
DO NOT CHANGE THE IFO ALIGNMENT UNTIL TOMORROW MORNING OR FURTHER NOTICE.
Plus, MC has to be kept locked with the WFS.
 
    Reply  Mon Nov 21 12:48:00 2011, Jenne, Update, IOO, RFAM monitoring test 
I don't think I touched/adjusted/whatever anything, but I did open the PSL table ~5-10min ago to measure the size of the Kiwamu-Box, so if the RFAM stuff
looks funny for a few minutes, it was probably me.  Just FYI.
    Reply  Mon Nov 21 14:15:25 2011, Jenne, Update, IOO, RFAM monitoring test 


    
        
            Quote:
        
        
            
            DO NOT CHANGE THE IFO ALIGNMENT UNTIL TOMORROW
    Reply  Mon Nov 21 14:35:28 2011, kiwamu, Update, IOO, RFAM monitoring test REFL_RFAM.png

 This is a trend for a day long showing the REFL11/55 demod signals, REFLDC (corresponding to the MC transmitted power) and the PSL booth
       Reply  Mon Nov 21 17:48:36 2011, Koji, Update, IOO, RFAM monitoring test 
Do we care about the AC? I thought what we care is the DC.
Entry  Mon Nov 21 15:47:58 2011, Mirko, Update, IOO, Osem loop shape OsemFilterShape.pdf
[Jenne, Mirko]
To reiterate: We changed the OSEM loop shape for MC1-MC3. Below in black is the old loop shape, which
simulated pendulum response in there. In red is the new loop shape.
Entry  Sun Nov 20 13:51:54 2011, steve, Update, VAC, vacuum is back up after ac interruption notpumping.png
State condition: Vac Normal,          CC1 ~8e-6 Torr
The IFO pressure peaked at  8.3 mTorr after 2days of not pumping.
Entry  Sat Nov 19 15:58:04 2011, Mirko, Update, IOO, Some more looks into OSEM noise 8x
[Den, Mirko]
We looked some more into the the OSEM signals and their coherence to the seismometer signals.
We were able to verify that the coherence OSEM sensor <-> seismometer signal goes down with increasing the OSEM gain. This seems to indicate
Entry  Fri Nov 18 15:45:11 2011, Mirko, Update, IOO, Mode cleaner noise projection WholeMCNoiseProjection.pngWholeMCNoiseProjection.fig
[Rana, Den, Mirko]
Updated the MC noise projection to include the longitudinal motion of the MC mirrors.
    Reply  Fri Nov 18 19:57:19 2011, Mirko, Update, IOO, Mode cleaner noise projection MC_ELP.pngWithAndWithoutHPs.pdfSeismCoh.pdf
 
Some more info on this:
 
       Reply  Fri Nov 18 23:44:33 2011, rana, Update, IOO, Mode cleaner noise projection 
Could use some more detail on how this measurement was done. It looks like you used the SUSPOS signal with the mirror moving, however, this is not what
we want. Of course, the SUSPOS with the mirror moving will always show the mirror motion because the OSEMs are motion sensors.
Instead, what we want is to project how the actual OSEM noise in the presence of no signal shows up as MC length. For that we should use the old
          Reply  Sat Nov 19 01:26:16 2011, Den, Update, IOO, Mode cleaner noise projection 


    
        
            Quote:
        
        
            

           Instead, what we want is to project how the actual OSEM noise in the presence of no signal shows up as MC length. For that we should use
          Reply  Sat Nov 19 12:57:55 2011, Mirko, Update, IOO, Mode cleaner noise projection CouplingMClengthsToMCF.pdfNpModeCleaner.pdf


    
        
            Quote:
        
        
            
            Could use some more detail on how this measurement was done. It looks like you used the SUSPOS signal with the mirror
Entry  Sat Nov 19 06:04:43 2011, Suresh, Update, IOO, MC_WFS Servo: The MC2_TRANS_PIT and YAW loops switched ON WFS_OUTMx_Lastgood.pngWFS_OUTMATRIX_20111118.pngWFS_err_MC2T_on_OMx5_20111118.png
Without adding significant amounts of noise to other WFS loops I have engaged the MC2_TRANS_PIT and YAW loops. 
After several attempts to measure the system response and computing the output matrix, none of which gave any useful results, I gave up on that
and decided to find three orthogonal actuation vectors which enable us to close the loops.  So using the last good output matrix (below left side) 
    Reply  Sat Nov 19 10:41:30 2011, rana, Update, IOO, MC_WFS Servo: The MC2_TRANS_PIT and YAW loops switched ON 
I'm quite sure that this is not good: since MC2 can produce a signal in WFS1 and WFS2, it cannot
be removed in this way from the actuation without introducing a significant cross-coupling between the MC_TRANS and WFS loops.
Really need loop TFs measured and compared with the model.
Entry  Sat Nov 19 00:47:24 2011, Zach, Update, Green Locking, Y-Arm locked with PDH Box #17 error_sig_m_11_18_11.png
I installed the newly modified PDH box #17 and locked the Y-Arm.
I wasn't able to bring the REFL level down to the 30% that Kiwamu claimed to get, despite readjusting the alignment---I got ~40-45%. I attained
a UGF of ~8 kHz, lower than the 20 kHz that Kiwamu said he got with the temporary setup, probably because
Entry  Sat Nov 19 00:34:36 2011, Zach, Update, RF System, why the Newport 6000 isn't working 
 I just figured out why the Newport 6000 isn't stabilizing the temperature. It is designed to drive a TEC,
so that when the temperature is too high, it just applies a negative current. Of course, this doesn't work with a resistive heater; it just keeps heating
it up more.
Entry  Fri Nov 18 19:07:07 2011, Jenne, Update, RF System, Foam house on EOM 
[Jenne, Zach, Frank]
Frank helped Zach and I cable up at PT-100 RTD, and make sure it worked with the Newport Model 6000 Laser Diode Controller.  We're using this
rather than the Newport 3040 Temperature Controller because Dmass says the output of that isn't working.  So we're using just the temp control part
    Reply  Sat Nov 19 00:09:02 2011, Zach, Update, RF System, Foam house on EOM 


    
        
            Quote:
        
        
            

           I used aluminum tape to attach the sensor and heater to the 40m's EOM, and we plugged in the controller.  It seems to be kind of working. 
Entry  Fri Nov 18 16:37:14 2011, steve, Update, VAC, preparing for ac power interruption planednopower.png
The vacuum is ready for no AC power for 1 hr on Sunday morning at 10am
 
I did the follwing:
Entry  Fri Nov 18 02:50:10 2011, kiwamu, Update, IOO, RF generation box : power switch malfunction broken_power_switch.png
[Suresh / Kiwamu]
 The power switch button of the RF generation box is not properly working 
    Reply  Fri Nov 18 15:35:18 2011, kiwamu, Update, IOO, RF generation box : power switch malfunction 
Jenne gave me a spare LED power switch .
I will replace the broken one on Monday.
Entry  Wed Nov 16 21:01:08 2011, Jenne, Update, Treasure, eom box 
I made a super sweet new foam box for our EOM.  It's awesome, and should be reasonably easy to duplicate.  Check out the PHOTOS!
Notes:
* I didn't think I was going to cover the inside of the box at first, since the foam is non-fuzz-generating, but Koji suggested it would be a good
    Reply  Fri Nov 18 11:16:08 2011, rana, Update, IOO, eom box 


    
        
            Quote:
        
        
            

           I made a super sweet new foam box for our EOM.  It's awesome, and should be reasonably easy to duplicate.  Check out the PHOTOS!
Entry  Fri Nov 18 08:29:35 2011, Suresh, Update, IOO, HEPA air-flow effect on WFS. WFS_err_HEPA.pngWFS_err_mc2t_effect.png
[Koji, Suresh]
    We investigated the effect of airflow from the HEPA filters on the PSL beam fluctuation and the resultant noise injected into
the WFS loops.   The hint that the WFS are injecting PSL beam jitter into MC mirror motion lies in the MC2_TRANS_PIT and YAW signal's power spectrum
Entry  Fri Nov 18 01:27:04 2011, Den, Update, IOO, MC locked cohnolocalpumping-crop_4.pdfcohlocalpumping4-crop.pdfcohlock4-crop.pdf
[Mirko, Den]
While the MC was unlocked (and the local damping off) we've measured the coherence between GUR1_X and OSEM sensors. It was rather high, close to
1 at frequencies 0.1 - 1 Hz. That means that stack does not kill all coherence between seismic noise and mirror motion.
Entry  Wed Jun 1 11:31:50 2011, josephb, Update, CDS, MC1 LR digital reading close to zero, readback ~0.7 volts 
There appears to be a bad cable connection somewhere on the LR sensor path for the MC1 optic.
The channel C1:SUS-MC1_LRPDMon is reading back 0.664 volts, but the digital sensor channel, C1:SUS-MC1_LRSEN_INMON,
is reading about -16.  This should be closer to +1000 or so.
    Reply  Sun Jun 26 22:38:20 2011, rana, Update, CDS, MC1 LR dead for > 1 month; now revived temporarily lrsen.pngbt.jpg
 Since the MC1 LRSEN channel is not wasn't working, my input matrix diagonalization hasn't worked today wasn't
working. So I decided to fix it somehow.
I went to the rack and traced the signal: first at the LEMO monitor on the whitening card, secondly at the 4-pin LEMO cable which goes into the
       Reply  Mon Jun 27 00:23:11 2011, rana, Update, CDS, ETMX SIDE problem etmx-side.png
The slow readback of the ETMX side seems to also have something flaky and bi-stable. This is not an issue for damping, but it disables the SIDE watchdog
for ETMX and makes it unsafe if we accidentally use the wrong damping sign. 
       Reply  Fri Nov 18 01:12:14 2011, Suresh, Update, CDS, MC1 LR dead for > 1 month; now revived temporarily 
[Den, Mirko, Suresh]
    We were investigating why there is no correlation between MC1 osem signals and seismic motion.   During this we noticed
a recurrence of this old problem of MC1_LR sensor being dead.  I went and pressed down the chip holders where the AA filters used to sit and which
Entry  Fri Nov 18 00:36:23 2011, Zach, Update, Green Locking, Y-Arm PDH box modified pdh17_tf_vs_liso_11_17_11.png
I modified the Y-Arm PDH box (S/N 17) to have the same TF as
the one of the temporary setup described in Kiwamu's earlier entry. 
Entry  Fri Nov 18 00:25:10 2011, Zach, Update, elog, restarted 
 with script.
Entry  Thu Nov 17 23:47:43 2011, Den, Update, IOO, MC1_SENSOR MC1SENSOR-crop.pdf
The most interesting plot did not uploaded in the previous elog.
Upload now local MC1_SENSOR signals.
Entry  Thu Nov 17 23:44:48 2011, Den, Update, IOO, MC1_SENSOR MCSENSORS.pdf
We've found that one of the  MC1_SENSORS does not work properly.
See the figure.
Entry  Thu Nov 17 23:38:40 2011, Den, Update, IOO, MC unlocked 
MC is unlocked to measure the free swing of the MC mirrors with the local sensors.
Autolocker is disabled.
Entry  Thu Nov 17 22:24:19 2011, Den, Update, Adaptive Filtering, MC1_COIL MC1COIL-crop.pdfMC2COIL-crop.pdfMC3COIL-crop.pdf
Analyzing coherence between MC length and signals on MC1, MC2 and MC3 coils we have noticed that MC1 COIL signal is not coherent to MC length at all
at interesting frequencies 0.1 - 1 Hz.
We try to explain this phenomena.
ELOG V3.1.3-