  15453   Mon Jul 6 08:48:15 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake lab today
from 8:30am to 4pm
  
  15459   Wed Jul 8 08:51:35 2020 JordanUpdateGeneralPresence at 40mI will be in the clean and bake lab today
from 9am to 3pm.
  
  15461   Thu Jul 9 09:22:44 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake lab today
from 9am to 3pm
  
  15467   Fri Jul 10 10:37:30 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake lab today
from 9am to 4pm
  
  15478   Tue Jul 14 09:04:53 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake Lab today
from 9am to 4pm.
  
  15492   Fri Jul 17 09:03:58 2020 JordanUpdateGeneralPresence at 40mI will be in the Clean and Bake lab today
from 9am to 4pm.
  
  15500   Fri Jul 24 15:40:59 2020 JordanUpdateVACInstallation of two new UPS unitsI installed the Tripp
Lite SMX1000RT2U and Tripp
Lite Smart1000LCD at the
 UPS.jpg 
  15591   Mon Sep 21 15:57:08 2020 JordanUpdateVACTP3 Forepump Replacement and Vac resetI removed the forepump (Varian SH-110)
for TP3 today to see why it had failed over
the weekend. I tested it in the C&B lab
 Screenshot_from_2020-09-21_15-56-04.png20200921_145043.jpg20200921_145040.jpg 
  15602   Wed Sep 23 15:06:54 2020 JordanUpdateVACTP2 Forepump Re-installI removed the forepump to TP2 this morning
after the vacuum failure, and tested in the
C&B lab. I pumped down on a small volume
 Screenshot_from_2020-09-23_15-15-43.pngMainVolPumpDown.png 
  15615   Tue Oct 6 14:35:16 2020 JordanUpdateVACSpare forepumpsI have placed 3 new in box, IDP 7 forepumps
along the x arm of the interferometer. These
are to be used as spares for both the 40m
  
  15806   Fri Feb 12 15:03:48 2021 JordanUpdateSUSCoM on 3"->2" Adapter Ring for SOSAs it currently stands the Center of Mass
of the Adapter Ring/Optic assembly is 0.0175"
out of the plane formed by the suspension
 Screenshot_(1).pngScreenshot_(3).pngCoM.PNG 
  15823   Fri Feb 19 15:17:51 2021 JordanUpdateSUSCoM Range on 3"->2" Adapter Ring for SOSAdjusting the thickness of the cylindrical
hole for the mirror on the 2" optic
sleeve, from .6875" to .61" thick,
 Neutral_Point.pngDumbell_Max_Negative_Travel.pngDumbell_Max_Positive_Travel.png 
  15929   Wed Mar 17 10:52:48 2021 JordanUpdateSUS3" Ring Adpater for SOS I have added a .1", 45deg chamfer
to the bottom of the adapter ring. This was
added for a new placement of the eq stops,
 Side_View.pngFront_View.pngRing_with_Modifed_Bracket.pngBack_of_ring.pngFront_of_Ring.png 
  16004   Wed Apr 7 13:07:03 2021 JordanUpdateSUSCoM on 3"->2" Adapter Ring for SOSAdding the chamfer around the edge of the
optic ring did not change the center of mass
relative to the plane from the suspension
 CoM_with_Chamfer.pngMoments_of_Inertia.PNG 
  16047   Mon Apr 19 09:17:51 2021 JordanUpdateVACEmpty N2 TanksWhen I came into the lab this morning,
I noticed that both N2 tanks were empty.
I had swapped one on Friday (4-16-21) before
 N2_Pressure.PNG 
  16064   Wed Apr 21 12:56:00 2021 JordanUpdateVACEmpty N2 TanksInstalled T2 today, and leaked checked
the entire line. No issues found. It could
have been a bad valve on the tank itself.
 Screenshot_2021-04-21_12-53-26.png 
  16135   Wed May 12 14:23:20 2021 JordanUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI units   Moments_of_Inertia_SI.PNG 
  16137   Wed May 12 17:06:52 2021 JordanUpdateSUSMass Properties of SOS Assembly with 3"->2" Optic sleeve, in SI unitsHere are the mass properties for the only
the test mass assembly (optic, 3" ring,
and wire block). (Updated with g*mm^2)
 Moments_of_Inertia_SI.PNG 
  16165   Thu May 27 14:11:15 2021 JordanUpdateSUSCoM to Clamping Point Measurement for 3" Adapter RingThe current vertical distance between the
CoM and the wire clamping point on the 3"
Ring assembly is 0.33mm. That is the CoM
 CoM_to_Clamp.PNGCoM_to_Clamp_2.PNG 
  16169   Tue Jun 1 14:26:23 2021 JordanUpdateSUSCoM to Clamping Point Measurement for 3" Adapter RingAfter changing the material of the Balance
Mass from 6061 Al to 304 Steel, and changing
the thickness to 0.21" from 0.25".
 CoM_to_Clamp_Updated.PNG 
  16296   Wed Aug 25 08:53:33 2021 JordanUpdateSUS2" Adapter Ring for SOS Arrived 8/24/218 of the 2"->3" adapter rings
(D2100377) arrived from RDL yesterday. I
have not tested the threads but dimensional
 20210824_152259.jpg20210824_152259.jpg20210824_152308.jpg 
  16305   Wed Sep 1 14:16:21 2021 JordanUpdateVACEmpty N2 TanksThe right N2 tank had a bad/loose valve
and did not fully open. This morning the
left tank was just about empty and the right
  
  16326   Tue Sep 14 16:12:03 2021 JordanUpdateSUSSOS Tower HardwareYehonathan noticed today that the silver
plated hardware on the assembled SOS towers
had some pretty severe discoloration on it.
 20210914_160111.jpg 
  16364   Wed Sep 29 09:36:26 2021 JordanUpdateSUS2" Adapter Ring Parts for SOS Arrived 9/28/21The remaining machined parts for the SOS
adapter ring have arrived. I will inspect
these today and get them ready for C&B.
 20210929_092418.jpg 
  16419   Thu Oct 21 11:38:43 2021 JordanUpdateSUSStandoffs for Side Magnet on 3" Adapter Ring SOS AssemblyI had 8 standoffs made at the Caltech chemistry
machine shop to be used as spacers for the
side magnets on the 3" Ring assembly.
 Magnet_Standoffs.jpg 
  16494   Wed Dec 8 10:14:43 2021 JordanUpdateVACPumping down the RGA sectionAfter an overnight pumpdown/RGA warm up,
I took a 100 amu scan of the RGA volume and
subsequent pumping line. Attached is a screenshot
 40m_RGAVolume_12_8_21.PNG40m_RGAVolume_Torr_12_8_21.PNG 
  16508   Wed Dec 15 15:06:08 2021 JordanUpdateVACVacuum Feedthru InstallJordan, Chub

We installed the 4x DB25 feedthru
flange on the North-West port of ITMX chamber
  
  16634   Mon Jan 31 10:39:19 2022 JordanUpdateVACTP1 and Manual Gate Valve RemovalJordan, Chub

Today, Chub and I removed TP1 and
the failed manual gate valve off of the pumping
 20220131_100637.jpg20220131_102807.jpg20220131_102818.jpg20220131_100647.jpg 
  16643   Thu Feb 3 10:25:59 2022 JordanUpdateVACTP1 and Manual Gate Valve InstallJordan, Chub

Chub and I installed the new manual
gate valve (Nor-Cal GVM-6002-CF-K79) and
 20220203_101455.jpg20220203_094831.jpg20220203_094823.jpg 
  16717   Wed Mar 9 10:23:28 2022 JordanUpdateVACLeak Testing of New Manual Gate Valve - Attempt #1Jordan, Chub, Paco

Chub and I went into the lab this
morning to leak check the new gate valve
  
  16721   Thu Mar 10 09:39:59 2022 JordanUpdateVACLeak Testing of New Manual Gate Valve - Attempt #2This morning Chub and I leak checked the
manual gate valve with the RGA and helium.
There was no change in the helium partial
 3-09-2022.PNG3-10-2022.PNG 
  16772   Tue Apr 12 09:05:21 2022 JordanUpdateVACNew Pressure Gauge Install/Pump Spool VentToday, Tega and I would like to vent the
pump spool an dinstall the new FRG-400 Agilent
Pressure Gauges (per elog 15703). The attached
 6x 
  16777   Thu Apr 14 09:04:30 2022 JordanUpdateVACRGA Volume RGA ScansPrior to venting the RGA volume on Tuesday
(4/12/2022) I took an RGA scan of the volume
to be vented (RGA+TP1 volume+Manual Gate
 40mRGA_Overlay.pdfRGAVolume_4_12_22.PNG 
  16806   Fri Apr 22 14:14:33 2022 JordanUpdateVACTP3 Forepump tip seal replacementJordan, JC

While the pumpspool is vented,
I thought it would be a convenient time to
 IMG_0572.jpegIMG_0573.jpeg 
  16822   Mon May 2 10:00:34 2022 JordanUpdateVACTP3 Forepump tip seal replacement[JC, Jordan]

Jordan recieved the new tip seal
Friday afternoon and I continued the replacement
  
  10279   Sat Jul 26 15:30:15 2014 Joseph AreedaUpdateComputer Scripts / ProgramsNDS2 server propem on megatronThe NDS2 server on megatron was unresponsive
for what i think was the last couple of days.
The NDS the log file (~nds2mgr/logs/nds2-201407151045.log)
  
  5254   Wed Aug 17 12:14:27 2011 Josh SmithOmnistructureComputer Scripts / Programs40m summary page plansJosh Smith, Fabian Magana-Sandoval, Jackie
Lee (Fullerton)
Thanks to Jamie and Jenne for the
  
  1221   Fri Jan 9 17:30:10 2009 KakeruUpdateComputersSnapshots of MEDM screensI wrote a web page which shows snapshots of
MEDM screens generated by Yoich's script
(e-log #1206).
  
  1225   Tue Jan 13 18:59:09 2009 KakeruUpdateLSCAS CCD centering and ASDD demod phaseI tuned the demod-phase for PRCL and SRCL
hand-off, but it have not been optimized
enoughly.
  
  1241   Wed Jan 21 16:18:17 2009 KakeruUpdateLSCAS CCD centering and ASDD demod phaseI tuned the DD demod-pahse for SRM.
It was tuned as the error singnal is to be
0 when the cavity is locked.
  
  1249   Fri Jan 23 12:48:12 2009 KakeruUpdateoplevsarm cavity oplev calibrationI calibrated optlevs of x and y arm cavity,
indipendently from Peter's work.
 ITMX_pitch.png 
  1259   Thu Jan 29 17:24:41 2009 KakeruUpdateoplevsarm cavity oplev calibrationI calibrated optlevs again. My previous work
has a lot of mistakes, so ignore it.
  
  1262   Fri Jan 30 19:38:57 2009 KakeruUpdatePSLISS BadKakeru, Peter

We try to improve ISS bord, but there isn't
  
  1277   Fri Feb 6 09:52:35 2009 KakeruUpdatePSLCurrent shunt transfar functionI attach the transfar function of the current
shunt.
There is a little gap at 10 Hz for
 TF_CS_gain.pngTF_CS_phase.png 
  1278   Fri Feb 6 09:56:11 2009 KakeruUpdatePSLISS servo transfar functionI attache the transfar function of ISS
servo.
The 4th stage and variable gain amplifier
 TF_ISSservo_gain.pngTF_ISSservo_phase.png 
  1279   Fri Feb 6 10:46:40 2009 KakeruUpdatePSLISS servo and noiseI measured the output noise of eache stage
of ISS servo, and calcurated the noise ratio
between input and 
 ISS_servo_TF_noise.png 
  1289   Tue Feb 10 23:36:25 2009 KakeruUpdatePSLPA current and laser outputI changed the PA current and measured laser
output power (monitor PD signal).
The gain of ISS is 13dB
 PA_current_output.png 
  1295   Wed Feb 11 23:51:53 2009 KakeruUpdatePSLPA current and laser outputI attached a plot of ISS monitor PD and MOPA
output to PA current.
The both end of PA current (26.0353[A] and
 PA_current_output.png 
  1299   Thu Feb 12 18:35:10 2009 KakeruConfigurationPSLPA current limitter
I added a PA current limiter.
It is only a voltage devider (composed
  
  1328   Fri Feb 20 01:54:18 2009 KakeruUpdateComputer Scripts / Programstdsdata might have a bugI found a strange jump of value in my data
taken with tdsdata.
I couldn't find same jump in
 jumped_data.png 