40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 85 of 344  Not logged in ELOG logo
IDdown Date Author Type Category Subject Text Attachments
  13077   Fri Jun 23 02:43:43 2017 KaustubhHowToComputer Scripts / ProgramsTaking Measurements From AG4395ASummary:

I have written a code(a basic one
which needs a lot of improvements, but still
 Test_Files_and_Code.zipBode_Plot_with_Error_Bands.pdf 
  13076   Tue Jun 20 17:44:12 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetThe script didn't run properly last
night, due to an oversight of variable names!
It's been started again and has been
  
  13075   Tue Jun 20 16:28:23 2017 SteveUpdateVACRGA scan   RGAscan243d.pngRGAscan.png 
  13074   Tue Jun 20 14:58:08 2017 SteveUpdateCamerasGigE camera at ETMXGigE can be connected to ethernet. AR coated
1064 f50 can arrive any day now.

 ETMXgige.jpg 
  13073   Mon Jun 19 18:41:12 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetThe previous run of the script had produced
some dubious results!

The script has been modified and
  
  13072   Mon Jun 19 18:32:18 2017 jigyasaUpdateComputer Scripts / ProgramsSoftware Installation for image analysisThe IRAF software from the National Optical
Astronomy Observatory has been installed
locally on Donatella(for testing) following
  
  13071   Fri Jun 16 23:27:19 2017 Kaustubh, JigyasaUpdateComputersOttavia Connected to the Netgear BoxI just connected the Ottavia to the Netgear
box and its working just fine. It'll
remain switched on over the weekend.
  
  13070   Fri Jun 16 18:21:40 2017 jigyasaConfigurationCamerasGigE camera IP One of the additional GigE cameras has been
IP configured for use and installation. 

Static IP assigned to the camera-
  
  13069   Fri Jun 16 13:53:11 2017 gautamUpdateCDSslow machine bootfestReboots for
c1psl, c1iool0, c1iscaux
  
  13068   Fri Jun 16 12:37:47 2017 Kaustubh, JigyasaUpdateComputersOttavia Switched OnOttavia had been left running overnight
and it seems to work fine. There has been
no smell or any noticeable problems in the
  
  13067   Thu Jun 15 19:49:03 2017 Kaustubh, JigyasaUpdateComputersOttavia Switched OnIt has been working fine the whole day(we
didn't do much testing on it though).
We are leaving it on for the night.
  
  13066   Thu Jun 15 18:56:31 2017 jigyasaUpdateComputer Scripts / ProgramsMC2 Pitch-Yaw offsetA python
script to randomly vary the
MC2 pitch and yaw offset and correspondingly
  
  13065   Thu Jun 15 14:24:48 2017 Kaustubh, JigyasaUpdateComputersOttavia Switched OnToday, I and Jigyasa connected the Ottavia
to one of the unused monitor screens Donatella.
The Ottavia CPU had a label saying 'SMOKED''.
  
  13064   Thu Jun 15 01:56:50 2017 gautamUpdateASSETMY Oplev restoredSummary:

I tried playing around with
 ITMY_OLspec.pdf 
  13063   Wed Jun 14 18:15:06 2017 gautamUpdateASSETMY Oplev restoredI
replaced the Pentek Generic Whitening Board
and the Optical Lever PD Interface Board
  
  13062   Tue Jun 13 08:40:32 2017 SteveUpdateIMCIMC wonkinessHappy MC after last glitch at 10:28 so
the credit goes to Rana

 happy_MC.pnglast_glitch.png 
  13061   Mon Jun 12 22:23:20 2017 ranaUpdateIMCIMC wonkinesswonder if its possible that the slow glitches
in MC are just glitches in MC2 trans QPD?
Steve sometimes dances on top of the MC2
  
  13060   Mon Jun 12 17:42:39 2017 gautamUpdateASSETMY Oplev Pentek board pulled outAs part of my Oplev servo investigations,
I have pulled out the Pentek Generic Whitening
board (D020432) from the Y-end electronics
  
  13059   Mon Jun 12 10:34:10 2017 gautamUpdateCDSslow machine bootfestReboots for
c1susaux, c1iscaux, c1auxex
  
  13058   Fri Jun 9 19:18:10 2017 gautamUpdateIMCIMC wonkinessIt happened again. MC2 UL seems to have
gotten the biggest glitch. It's a rather
small jump in the signal level compared to
 MC2_UL_glitchy.pngMC2_glitch_fast.png 
  13057   Fri Jun 9 17:45:21 2017 Gautam, KaustubhUpdateIMCIMC wonkiness 




  
  13056   Fri Jun 9 16:37:29 2017 jigyasaUpdateComputer Scripts / ProgramsOpenCV installationOpenCV 3.1.0
has been installed by following the commands
locally on Donatella
  
  13055   Fri Jun 9 15:31:45 2017 gautamUpdateIMCIMC wonkinessI've been noticing
some weird behaviour with the IMC over the
 IMG_7409.JPG 
  13054   Fri Jun 9 09:13:26 2017 SteveUpdateCamerasGigE camera lens with AR We should move on with getting this
lens from Edmonds #67-717  at 1064
R<3% 
 coating_curve.pdf 
  13053   Thu Jun 8 12:43:42 2017 DhruvaUpdateOptical LeversBeam Profiling Results  




 profile.pdf 
  13052   Thu Jun 8 02:11:28 2017 gautamUpdateASSY-arm coil driver electronics investigation
p.p1
{margin: 0.0px 0.0px 0.0px 0.0px; font: 18.0px
'Helvetica Neue'; -webkit-text-stroke: #000000}
p.p3
 AnalogCheck.pdfAnalogCheck_zoom.pdfArmCtrl.pdf 
  13051   Wed Jun 7 17:45:11 2017 gautamUpdateASSY-arm coil driver electronics investigationI repeated the test of driving C1:SUS-<Optic>_<coil>_EXC
individually and measuring
 CoilTFs.pdf 
  13050   Wed Jun 7 15:41:51 2017 SteveUpdateComputerswindow laptop scannedRandy Trudeau scanned our Window laptop
Dell 13" Vostro and Steve's memory
stick for virus. Nothing was found. The search
  
  13049   Wed Jun 7 14:27:23 2017 SteveUpdateSummary Pagessummery pages not workingLast good page May 18, 2017

Not found, error message May 19
- June 4,2017
  
  13048   Wed Jun 7 14:11:49 2017 gautamUpdateASSY-arm coil driver electronics investigationRana suggested taking a look at the Y-arm
test mass actuator TFs (measured by driving
the coils one at a time, with only local
 CoilTFs.pdfY_OL_calib_check.png 
  13047   Wed Jun 7 11:32:56 2017 SteveUpdateVACsmooth vac rebootGautam and Steve,

 

The medm monitor & vac control
 vac_reboot.png 
  13046   Wed Jun 7 10:07:00 2017 SteveUpdatePEMair condition thermostateThe Y arm ac thermostate was calibrated
after cooling water relay replacement by
Mike.... yesterday. The set temp is remaind
  
  13045   Tue Jun 6 09:14:26 2017 SteveUpdateCamerasGigE installation at MC250mm
1.8 lens with
Basler camera at MC2 face with micro
 MC2.jpg 
  13044   Mon Jun 5 21:53:55 2017 ranaUpdateComputersrossa: ubuntu 16.04With the network config, mounting, and
symlinks setup, rossa is able to be used
as a workstation for dataviewer and MEDM.
  
  13043   Mon Jun 5 18:40:12 2017 jigyasaUpdateCamerasAttempt to run camera server Python code[Gautam, Jigyasa]

This
evening, Gautam helped me resolve the
  
  13042   Mon Jun 5 15:04:33 2017 ranaUpdateCamerasAttempt to run camera server Python codeRight - we want to be compatible with new
version of the code, so instead of moving
the files to where the code wants them you
  
  13041   Mon Jun 5 12:50:42 2017 jigyasaUpdateCamerasAttempt to run camera server Python codeI think there
might be a problem with the fact that
the installation of the various components
  
  13040   Mon Jun 5 12:27:34 2017 jigyasaUpdateCamerasAttempt to run camera server Python codeWhile attempting
to execute the Python/Pylon code for the
camera server, camera_server.py, the compiler
  
  13039   Mon Jun 5 10:30:45 2017 SteveUpdateSUSruby wire standoff picturesAtm 1 & 5, showing the ruby R ~10 mm
as it is seated on Al SOS test mass

Atm. 2, 3 & 4  chipped
 A087_R.png.bmpA097_chipped_edges.png.bmpA099_cal_wire.png.bmpA101_cal_wire_43_micron.png.bmpAl_SOS_R39mm.jpg 
  13038   Sun Jun 4 15:59:50 2017 gautamUpdateGeneralPower glitch - recoveryI
think the CDS status is back to normal.


Bit
 powerGlitchRecovery.png 
  13037   Sun Jun 4 14:19:33 2017 ranaFrogsComputersNetwork slowdown: Martians are behind a waterwallA
few weeks ago we did some internet speed
tests and found a dramatic difference between
 Screen_Shot_2017-06-04_at_1.47.47_PM.pngScreen_Shot_2017-06-04_at_1.44.42_PM.png 
  13036   Fri Jun 2 22:01:52 2017 gautamUpdateGeneralPower glitch - recovery[Koji, Rana, Gautam]

Attachment #1 - CDS
status at the end of todays efforts. There
 power_glitch_recovery.pngIMG_7406.JPGIMG_7407.JPGIMG_7400.JPG 
  13035   Fri Jun 2 16:02:34 2017 gautamUpdateGeneralPower glitchToday's
recovery seems to be a lot more complicated
than usual.


 IMG_7399.JPG 
  13034   Fri Jun 2 12:32:16 2017 gautamUpdateGeneralPower glitchLooks like there was a power glitch at
around 10am today.

All frontends, FB, Megatron, Optimus
  
  13033   Fri Jun 2 01:22:50 2017 gautamUpdateASSASS restoration workI started by checking if shaking an optic
in pitch really moves it in pitch - i.e.
how much PIT to YAW coupling is there. The
 ASS_Y_recovery.pngASS_Repairs.zipOLs.png 
  13032   Fri Jun 2 00:54:08 2017 KojiUpdateASSXarm ASS restoration workWhile Gautam is working the restoration
of Yarm ASS, I worked on Xarm.

Basically, I have changed the oscillator
 7x 
  13031   Thu Jun 1 20:16:11 2017 ranaUpdateCamerasGigE installation in the IFO areaGood installation. I think the images are
still out of focus, so try to resolve into
some small dots at the low exposure setting.
  
  13030   Thu Jun 1 16:21:55 2017 SteveUpdateSUS wire standoffs updateRuby
wire standoff received from China. I
looked one of them with our small USB camera. 
  
  13029   Thu Jun 1 16:14:55 2017 jigyasaUpdateCamerasGigE installation in the IFO areaThanks to Steve and Gautam, the IMC was
locked.

I was able to capture images with
 MC2.pdf 
  13028   Thu Jun 1 15:37:01 2017 gautamUpdateCDSslow machine bootfestSteve alerted me that the IMC wouldn't
lock. Reboots for
  
ELOG V3.1.3-