  2726   Mon Mar 29 02:07:50 2010 KojiSummaryPSLFSS Work from Sunday: Open Loop Gain


   
        
            
  
  2724   Mon Mar 29 01:11:33 2010 ranaSummaryPSLFSS Work from Sunday: RF Out SpectrumI measured the RF spectrum coming out
the FSS RFPD to look for saturations - its
close to the hairy edge. This is with
 rfout.pngTEK00000.PNGTEK00001.PNGTEK00002.PNG 
  2722   Sun Mar 28 23:17:46 2010 ranaSummaryPSLFSS Work from Sunday: noise specThis is the error point spectrum - it is
filled with huge multiples of ~75 kHz as
Yoichi noticed a couple years ago.
 in2.png 
  134   Wed Nov 28 17:41:34 2007 robUpdatePSLFSS againI investigated the FSS a bit more today. 
I looked at the signals coming out of the
FSS frequency reference, and saw that both
  
  1061   Mon Oct 20 20:50:09 2008 YoichiConfigurationPSLFSS board chip replacementA quick update.

I changed two AD797s on the FSS board to
  
  10370   Tue Aug 12 18:20:13 2014 ericqUpdateIOOFSS box TFsI made some measurements of the FSS box
today, to have TFs for a loop model, but
also to see what the difference between the
 FSSbox.pdfFSSfilt.pdfFSSdata.zip 
  10380   Wed Aug 13 23:08:17 2014 ranaUpdateIOOFSS box TFsAs EQ pointed out recently, we're injecting
into the FSS error point just after an RF
pi filter, but before the VGA. We wondered
 FSScomm.pdf 
  15230   Thu Feb 27 15:50:37 2020 gautamUpdateElectronicsFSS box power cable removedIn 1X1, there is a box labelled "FSS
REF" below a KEPCO HV supply. This box
had a power cable that wasn't actually
  
  3573   Wed Sep 15 01:27:52 2010 rana, steve, valeraUpdatePSLFSS cables connected- connected the TTFSS cables (FSS fast
goes directly to NPRO PZT for now)
- measured the reference cavity 21.5
  
  958   Wed Sep 17 17:31:24 2008 YoichiUpdatePSLFSS calibrationI calibrated the reference cavity error signal
with the following procedure.
 PZTresp.pngCalibration.pngFreqNoiseSpectrum.png 
  991   Thu Sep 25 10:48:29 2008 YoichiUpdatePSLFSS calibration againI did a calibration of the FSS error signal
again with a different method.
This time, I swept the laser frequency with
 PDTrans.pngPDHsignal.png 
  15310   Wed Apr 22 17:29:14 2020 gautamUpdatePSLFSS debugging attemptsSummary:

On Monday, I hooked up an AG4395
to the PMC error point (using the active
 FSSspec.pdf 
  15312   Thu Apr 23 10:42:02 2020 ranaUpdatePSLFSS debugging attemptsI had set up the 4395 to do this automatically
a few years ago, but it looked
at the FSS/IMC instead. When the PCDRIVE
  
  929   Thu Sep 4 17:44:27 2008 YoichiUpdatePSLFSS error signal spectrumAttached is a spectrum of the FSS error signal.
There are a lot of sharp peaks above 100kHz
(the UGF of the servo is about 200kHz).
 FSS-Error-Spe.png 
  8587   Thu May 16 01:41:31 2013 JenneSummaryIOOFSS gain settings set

    

       
            
  
  684   Wed Jul 16 17:36:51 2008 JohnDAQPSLFSS input offsetI changed the nominal FSS input offset to
0 from 0.3. Tolerance remains unchanged at
+/-0.05.
  
  10928   Thu Jan 22 02:56:07 2015 ericqUpdateIOOFSS input offset adjustedSince Rana's overhaul of the IMC, the
FSS input offset had been sitting at zero. 

Over the last day or so, I had
  
  575   Thu Jun 26 18:24:28 2008 YoichiUpdatePSLFSS input ofset slider problem - fixedI checked the FSS servo interface board and
found that a LT1125CSW used to differentialize
offset channel was broken (no virtual short).
  
  1048   Tue Oct 14 19:24:34 2008 YoichiConfigurationPSLFSS light power reducedRana, Yoichi

To change the gain distribution in the FSS,
  
  3574   Wed Sep 15 01:58:28 2010 valeraUpdatePSLFSS lockingThe RefCav is locked and aligned. I changed
the fast gain sign by changing the jumper
setting on the TTFSS board. The RefCav visibility
 DSC_2510.JPG 
  3575   Wed Sep 15 03:08:26 2010 KojiUpdatePSLFSS lockingBrilliant! This is the VERY way
how the things are to be conquered!

  
  124   Tue Nov 27 15:45:08 2007 robConfigurationPSLFSS loop
It's unclear (to me, at least) what was the
end result of the FSS path tweaking before
 FSSsmall.jpg 
  791   Mon Aug 4 13:43:02 2008 YoichiSummaryPSLFSS loop calibrationAs a part of the effort to repair the FSS
loop bandwidth, I tried to calibrate the
FSS loop.
 P7310048.JPGcavity-response.pdfcavity-response2.pdfcavity-gain.pdf 
  758   Tue Jul 29 19:41:38 2008 YoichiUpdatePSLFSS loop transfer functionsLast night I measured a bunch of transfer
functions on the FSS loop.
All the loop gains were measured with the
 7x 
  761   Tue Jul 29 23:04:34 2008 YoichiUpdatePSLFSS loop transfer functions[quote]
The measurement of the PZT open loop TF is
very suspicious. According to this, the PC
 OpltfPZTOnlyRaw.epsOpltfPZTOnly.eps 
  905   Fri Aug 29 22:57:48 2008 YoichiUpdatePSLFSS loop transfer functionsI've been measuring a bunch of transfer functions
of the FSS related stuffs.
There are a lot to be analyzed yet, but here
 OPLTFs.pdfOPLTFsScaled.pdf 
  907   Mon Sep 1 04:34:00 2008 ranaUpdatePSLFSS loop transfer functionsI started from 6th item in Yoichi's todo list.

1) Increased the setpoint of the thermostat
 n.pdfFSSLO.PNGFSSLO-Spec.pngPC25.pngpc.pdf 
  3561   Sun Sep 12 23:16:52 2010 valeraUpdate FSS mode matchingThe attached plot shows the beam scans
of the beam leaking from the back mirror
of the PMC to the BS cube that first turns
 fss.pdffssaom-abcd.tifffssrc-abcd.tiff 
  923   Thu Sep 4 13:48:50 2008 YoichiUpdatePSLFSS modulation depthI scanned the reference cavity with the NPRO
temperature (see the attached plot).
The power ratio between the carrier and the
 RCScan.png 
  1899   Thu Aug 13 22:53:48 2009 YoichiConfigurationPSLFSS nominal common gain changed, MC WFS centeredKoji, Yoichi
We found that the FSS PC feedback
easily goes crazy (saturated).
It
  
  10340   Wed Aug 6 17:29:36 2014 JenneUpdateIOOFSS offset changedThe MC has been unstable and unhappy for
the last several hours.  When I looked,
I saw that the FSS_FAST monitor has been
  
  10341   Wed Aug 6 21:22:09 2014 KojiUpdateIOOFSS offset changedThe fast feedback
should be around zero now!
  
  10344   Thu Aug 7 12:25:14 2014 JenneUpdateIOOFSS offset changed

    

       
            
  
  908   Mon Sep 1 19:23:17 2008 YoichiConfigurationPSLFSS on an auxiliary loopSummary: The FSS is now temporarily disabled.
Naturally, the MC won't lock. I will fix
it tomorrow morning.
  
  910   Tue Sep 2 09:58:42 2008 YoichiConfigurationPSLFSS on an auxiliary loop[quote]Summary: The FSS is now temporarily
disabled. Naturally, the MC won't lock. I
will fix it tomorrow morning.
  
  927   Thu Sep 4 17:12:57 2008 YoichiUpdatePSLFSS open loop TFI changed the gain settings of the FSS servo.
Now the Common Gain is 5dB (the last night
it was 2dB) and the Fast Gain is 12dB (formerly
 FSS-OPLTFs.png 
  711   Tue Jul 22 03:03:22 2008 John, RobUpdatePSLFSS open loop transfer functionWith the common gain slider maxed out the
unity gain frequency is 58kHz.
  
  715   Tue Jul 22 13:16:09 2008 John, RobUpdatePSLFSS open loop transfer function[quote]With the common gain slider maxed out
the unity gain frequency is 58kHz.
  
  2343   Sat Nov 28 20:27:12 2009 KojiUpdatePSLFSS oscillation: Total gain reducedI stopped by the 40m for some reason and
found that the MC trans was 7.5.
This was caused by an oscillation
 091128_PSL.png 
  1054   Thu Oct 16 16:26:26 2008 peteConfigurationPSLFSS phase matching cable installedRG 405 cable has a solid teflon dielectric,
and a velocity factor of 0.69.  To get the
8.2 degrees of additional phase on the LO
  
  1046   Tue Oct 14 14:19:36 2008 peteConfigurationPSLFSS ref phaseToday I made several measurements which should
yield the optimized phase for the FSS 21.5
MHz reference.  I made two sets of measurements,
  
  1050   Wed Oct 15 22:07:52 2008 peteConfigurationPSLFSS ref phase measurementsOptimizing the FSS LO/RF phase at 500 kHz,
above the servo band, proved to be noisy
and those measurements were useless.  Today
 phasedelay.png 
  1052   Thu Oct 16 09:47:49 2008 YoichiConfigurationPSLFSS ref phase measurements[quote] I fit the bottom (quadratic) portion
of this curve, and found an optimum delay
of 25.8 ns, which can be implemented as 25.81
  
  8460   Thu Apr 18 02:51:52 2013 DenUpdatePSLFSS slow servoToday Rana pointed out that our FSS slow
servo is malfunctioning. It has been for
a while that our laser temperature control
  
  121   Wed Nov 21 14:31:41 2007 robUpdatePSLFSS twiddle
I `tweaked' the FSS path today.  Here's what
I did:
  
  751   Mon Jul 28 23:41:07 2008 robConfigurationPSLFSS/MC gains twiddled
I found the FSS and MC gain settings in a
weird state.  The FSS was showing excess
  
  3346   Sun Aug 1 21:40:27 2010 ranaSummaryPSLFSS: SLOWDC responseI bet you thought that the NPRO slow actuator
response could be well represented by a pole
at ~0.1 Hz? Well, that's just what they want
 Untitled.png 
  17047   Fri Jul 29 20:21:11 2022 KojiUpdatePSLFSSSlow/MCAutolocker issue (docker)MCAutolocker/FSSSlow are not properly documented
and not properly working.
Tidy up the script and documentation,
  
  17049   Sat Jul 30 10:38:12 2022 AnchalUpdatePSLFSSSlow/MCAutolocker issue (docker)The FSSSlow script was not properly documented
and it was not working, so I had to use one
that I knew worked from CTN. This scripts
  
  17050   Sat Jul 30 12:48:18 2022 KojiUpdatePSLFSSSlow/MCAutolocker issue (docker)> it only starts working when C1:IOO-MC_LOCK
is 1 and C1:PSL-FSS_SLOWLOOP is 1.

- OK. Your new MCAutolocker does
  
ELOG V3.1.3-