40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 80 of 344  Not logged in ELOG logo
ID Datedown Author Type Category Subject Text Attachments
  13312   Fri Sep 15 15:54:28 2017 gautamUpdateCDSFB wiper scriptA wiper script is not yet set up for our
new Frame-Builder. The disk usage is ~80%
  
  13311   Tue Sep 12 11:44:16 2017 KiraUpdatePEMtemp sensor updateGot it to work. A cable was broken and
the AD586 also broke at the same time so
it took a while to find the problem. I had
  
  13310   Mon Sep 11 23:31:50 2017 johannesUpdateCameraspost-vent camera capture comparisonThe latest pre-unintended vent captures
of the test mass face cameras were taken
on June
 13x 
  13309   Mon Sep 11 16:46:09 2017 SteveUpdatePEMearthquakes


 M5.4eq.png 
  13308   Mon Sep 11 15:58:02 2017 SteveUpdateGeneralNPRO for repairThis NPRO has a tripping power output******

 
 NPRO_tripping.jpg 
  13307   Mon Sep 11 12:56:40 2017 johannesUpdateComputer Scripts / Programslossmap attemptsI was trying to get a lossmap measurement
over the weekend but had some trouble first
with the IMC and then with the PMC.
  
  13306   Mon Sep 11 12:40:32 2017 johannesUpdatePSLPSL table auxiliary NPROI changed the PSL table auxiliary laser
setup to the 200 MHz AOM and put the light
back in the fiber. Coupling efficiency is
 psl_aux_laser2.svg.pngPSL_IR2.png 
  13305   Mon Sep 11 09:47:53 2017 SteveUpdateGeneralWIMA caps refilledInstock WIMA caps refilled to a minimum
50 pieces each.
 WIMA.png 
  13304   Fri Sep 8 12:08:32 2017 GabrieleSummaryLSCGood reconstruction of PRMI degrees of freedom with deep learningIntroduction

This is an update
of my previous reports on applications of
deep learning to the reconstruction of PRMI
 full_real_data_2017_09_06b_100x4_4000_300_20_free_swinging_time_domain.png.pngfull_real_data_2017_09_06b_100x4_4000_300_20_free_swinging_free_swinging_histograms2d.png.pnggru_2017_08_13a_100x4_4000_300_20_free_swinging_simulation_reference.png.png 
  13303   Fri Sep 8 10:22:30 2017 SteveUpdatePEMtemp sensor updateThe weight of SS can with copper liner 
is 12.2 kg

Is 1 Amp for the heating jacket
  
  13302   Fri Sep 8 07:54:04 2017 SteveUpdatePEMM8.1 eqNothing tripped. No obvious damage.  M8.1.png 
  13301   Thu Sep 7 23:09:00 2017 johannesUpdatePSLPSL table auxiliary NPROI brought the DEI Pulser
unit and a suitable Pockels cell
over from Bridge today (I also found an identical
 3200-1113_200_switching_PD10A_zoomin.png3200-1113_200_switching_PD10A_zoomout.png 
  13300   Wed Sep 6 23:06:30 2017 gautamUpdateLSCCoil de-whitening switching investigationSummary:

Rana
suggested checking if the coil de-whitening
switching is actually happening in the analog
 BScoils.pdfITMcoils.pdf 
  13299   Wed Sep 6 01:09:11 2017 johannesUpdateComputer Scripts / ProgramsNew set of loss measurementsI
stumbled upon a faster way to stream data from
 XARM_20170905.pdfYARM_20170905.pdf 
  13298   Tue Sep 5 23:13:44 2017 johannesUpdatePSLPSL table auxiliary NPROI used Gautam's mode measurement of
the auxiliary NPRO (w=127.3um,
z=82mm) for the spacing of the optics
 PSL_IR.pdfpsl_aux_laser.pdf 
  13297   Tue Sep 5 23:02:37 2017 gautamUpdateCDSslow machine bootfestMC autolocker was not working - PCdrive was railed
at its upper rail for ~2 hours judging by
  
  13296   Tue Sep 5 17:52:06 2017 KiraUpdatePEMtemp sensor updateto get the sensors to read the same values
they have to be in direct thermal contact
with the metal block - there can't be
  
  13295   Tue Sep 5 17:18:17 2017 KiraUpdatePEMtemp sensor updateToday, I stuck on the sensors to a metal
block using a flag, rubber bands, and some
thermal paste (1st attachment). I then wrapped
 IMG_20170905_144924.jpgIMG_20170905_165042.jpg 
  13294   Tue Sep 5 16:37:47 2017 GabrieleSummaryLSCImproved PRMI deep learning reconstructionThis is an update on the results already
presented earlier (refer to elog 13274 for
 Unknown.pnggru_2017_08_13a_100x4_4000_300_20_free_swinging_time_domain.png.pnggru_2017_08_13a_100x4_4000_300_20_free_swinging_free_swinging_histograms2d.png.pnggru_2017_08_13a_100x4_4000_300_20_free_swinging_simulation_reference.png.png 
  13293   Tue Sep 5 14:41:58 2017 gautamUpdateCDSNDS2 server restarted on megatronI was unable to download data using nds2.
Gabriele had reported similar problems a
week ago but I hadn't followed up on
  
  13292   Tue Sep 5 09:47:34 2017 KiraSummaryPEMheater circuit calculationsI decided to calculate the fluctuation
in power that we will have in the heater
circuit. The resistors we ordered have 50
  
  13291   Tue Sep 5 02:07:49 2017 gautamUpdateLSCLow Noise DRMI attemptSummary:

Tonight, I was able
 MICH_err_comp.pdfdeWhitenedCoil.pdf 
  13290   Mon Sep 4 18:18:29 2017 ranaUpdateLSCdewhite switching: FOTON settingsnot immediately necessary, since you have
already got it sort of working, but one of
these days we should optimize this for real.
  
  13289   Mon Sep 4 16:30:06 2017 gautamUpdateLSCOplev loop tweakingNow that the DRMI locking seems to be repeatable
again, I want to see if I can improve the
measured MICH noise. Recall
  
  13288   Fri Sep 1 19:15:40 2017 gautamUpdateALSFiber ALS noise measurementSummary:

I
did some work today to see if I could use
 IR_ALS_noise.pdf 
  13287   Fri Sep 1 16:55:27 2017 gautamUpdateComputersTestpoints now accessible againThanks to   
  13286   Fri Sep 1 16:27:39 2017 gautamUpdateSUSMC1 glitchingI re-enabled the MC SUS damping and IMC
locking for some IFO work just now.

  
  13285   Fri Sep 1 15:46:12 2017 KiraUpdatePEMtemp sensor updateI took off the AD590 and attached it to
two long wires leading out from the board.
This will allow us to attach the sensor to
 IMG_20170901_144729.jpg 
  13284   Fri Sep 1 08:25:08 2017 SteveUpdateSUSMC1 glitchingMC1, MC2 and MC3 damping turned off to
see glitching action at 9:57am

 MC1glitching.pngMC1kicks.png 
  13283   Thu Aug 31 21:40:24 2017 gautamUpdateGeneralMC1 kicked againThere was a pretty large glitch in MC1
about an hour ago. The misalignment was so
large that the autolocker wasn't able
 MC1_glitch.png 
  13282   Thu Aug 31 18:36:23 2017 gautamUpdateCDSrevisiting Acromag Current
status:


There
is a single Acromag ADC unit installed in
 Acromag_EPICS.png 
  13281   Thu Aug 31 03:31:15 2017 gautamUpdateLSCDRMI re-locked!After our Demod/Whitening electronics investigations
suggested nothing obviously wrong, I decided
to give DRMI locking another go tonight.
 DRMI_1f.pngDRMI_relocked.pdf 
  13280   Thu Aug 31 00:52:52 2017 gautamUpdateLSCREFL55 whitening board debugging[rana,gautam]  REFL55_whtCheck.pdfREFL55_whtChk.tar.gz 
  13279   Thu Aug 31 00:46:57 2017 ranaSummaryCDSallegra -> Scientific Linux 7.3I made a
'LiveCD' on a 16 GB USB stick using
this command after the GUIs didn't work
  
  13278   Thu Aug 31 00:19:35 2017 rana[^r]UpdatePSLIMC/FSS FAST gainnominal changed from 22 to 23 dB to minimize
PC drive RMS

  
  13277   Wed Aug 30 22:15:47 2017 ranaOmnistructureComputersUSB flash drives movedI have moved the USB
flash
  
  13276   Wed Aug 30 19:49:33 2017 gautamUpdateLSCREFL55 demod board debuggingSummary:

Today
I tried debugging the mysterious increase
in REFL55 signal levels in the DRMI configuration.
 REFL55_demod_check.pdf 
  13275   Wed Aug 30 15:00:06 2017 gautamUpdateGeneralEdgeswitch fiber swapA couple of minutes ago, Larry W swapped
the fibers to our 40m Edgeswitch (BROCADE
FWS 648G) to a faster connection. This is
  
  13274   Wed Aug 30 11:04:08 2017 GabrieleSummaryLSCFirst look at neural network reconstruction of PRMI motionIntroduction

I trained a deep
neural network (DNN) to reconstruct MICH
and PRCL degrees of freedom in the PRMI configuration.
 IMG_5882.pnggru_2017_08_13a_100x4_4000_300_20_free_swinging_time_domain.png.pnggru_2017_08_13a_100x4_4000_300_20_free_swinging_free_swinging_histograms2d.png.pngsimulation_histograms2d.png.png 
  13273   Wed Aug 30 10:54:26 2017 gautamUpdateCDSslow machine bootfestMC autolocker and FSS loops were stuck
because c1psl
  
  13272   Wed Aug 30 06:45:32 2017 KevinSummaryPEMNew Heater CircuitI changed the heater circuit described
in this
elog to a current sink. The new and old
 circuit.pdf 
  13271   Tue Aug 29 21:36:59 2017 johannesUpdatePSLPSL table auxiliary NPRO


 isomet_mini_1st_zoomout.pngisomet_mini_0th_zoomout.png 
  13270   Tue Aug 29 20:04:09 2017 ranaUpdatePSLPSL table auxiliary NPROI don't understand why the 1st order
diffracted beam doesn't go to zero when
you shut off the drive. My guess is that
  
  13269   Tue Aug 29 15:41:17 2017 KiraSummaryPEMheater circuitI worked with Kevin and Gautam to create
a heater circuit. The first attachment is
Kevin's schematic of the circuit. The
 heater_circuit.pdfsimulation.pngheater_setup.jpgIMG_20170829_131126.jpg 
  13268   Tue Aug 29 15:35:19 2017 SteveUpdateVACvacuum pump specifications & manualsRP1 and RP3 roughing pump manual of
Leybold D30A oily rotory pump

Fore pump of
 1759489_995814a9-55c1-4fa1-b333-f446d272c1cc.jpg 
  13267   Tue Aug 29 15:04:59 2017 gautamUpdateSUSETMY Oplev PIT loop gain changedLast night, while we were working on the
ALS, I noticed the GTRY spot moving around
(in PITCH) on the CCD monitor in the control
 ETMY_OLPIT.pdfGTR_comparison.pdf 
  13266   Tue Aug 29 02:08:39 2017 gautamUpdateALSFiber ALS noise measurementI was having a chat with EricQ about this
today, just noting some points from our discussion
down here so that I remember to look into
  
  13265   Tue Aug 29 01:52:22 2017 gautamUpdateSUSTest mass actuator calibration[ericq, gautam]

Tonight,
 ALS_comparison.pdf 
  13264   Mon Aug 28 23:22:56 2017 johannesUpdatePSLPSL table auxiliary NPROI moved the axuiliary NPRO to the PSL table
today and started setting up the optics.

The Faraday Isolator was showing
 aom_switching_zoomin.pngaom_switching_zoomout.pngaom_switching_mini_zoomin.pngaom_switching_mini_zoomout.png 
  13263   Mon Aug 28 17:13:57 2017 ericqUpdateCDS40m files backup situationIn addition to bootable full disk backups,
it would be wise to make sure the important
service configuration files from each machine
  
ELOG V3.1.3-