  3732   Mon Oct 18 08:44:36 2010 ranaUpdateCDSslow DAQ channels addedWhy EXCMON? I think that we should
modify the filter coefficients so that the
decimation filter that makes OUT16 is a 2nd
  
  3733   Mon Oct 18 09:01:48 2010 steveHowToGeneralHow not to This BNC cable is crying for help. Please
do not do this to me.  It should be
reported  to the  abused center.Throw
 P1060926.JPG 
  3734   Mon Oct 18 11:22:13 2010 JenneUpdateComputersShame on people not elogging! FrameFiles backups not working.On the one hand, SHAME
ON ALL PEOPLE WHO DON'T ELOG THINGS,
  
  3735   Mon Oct 18 15:33:00 2010 josephb, alexUpdateCDSPossibly broken timing cardsIt looks as though we may have two IO chassis
with bad timing cards.
Symptoms are as follows:
  
  3736   Mon Oct 18 17:16:30 2010 JenneUpdateSUSOld PRM, SRM stored, new PRM drag wiped[Jenne, Suresh]
We've put the old PRM and SRM (which
were living in a foil house on the cleanroom
  
  3737   Mon Oct 18 18:00:36 2010 KojiUpdateSUSOld PRM, SRM stored, new PRM drag wiped- Steve is working on the storage shelf
for those optics.
- PRMU002 was chosen as it has the
  
  3738   Mon Oct 18 18:33:46 2010 KojiSummaryCOCSummary of the main mirrors & their phasemap measurementI have made a summary web page for the
40m upgrade optics.
https://nodus.ligo.caltech.edu:30889/40m_phasemap/
  
  3739   Mon Oct 18 22:11:32 2010 Joonho LeeSummaryElectronicsCCD cables for input signalToday
I checked all the CCD cables which is connected
input channels of the VIDEOMUX.
  
  3740   Tue Oct 19 00:24:07 2010 DmassOmnistructureElectronicsMassive restocking of the 40mI had a number of delinquent items on the
sign out list from the 40m. I returned about
half, and ordered replacements for most of
  
  3741   Tue Oct 19 15:14:51 2010 JenneUpdateSUSPRM (little) update[Jenne, Suresh]
We've aligned the guiderod and wire
standoff to the PRM, each partly.  They
  
  3742   Tue Oct 19 21:10:27 2010 yutaUpdateCDSbad filter coefficients for every suspensions!(Koji, Yuta)

Summary:
  
  3743   Tue Oct 19 22:37:28 2010 KojiUpdatePSLPSL table cleaning upI cleaned up the scattered tools, optics,
and mounts of the PSL table. I gathered those
stuffs at the two coners.
  
  3744   Wed Oct 20 01:22:18 2010 yutaUpdateCDSfixed filters for MCs, but no damping(Rana, Yuta)

Summary:
 Screenshot.png 
  3745   Wed Oct 20 16:41:41 2010 steveOmnistructureGeneral laser chiller leaving for MIT   P1060929.JPG 
  3746   Wed Oct 20 18:17:35 2010 Suresh, JenneUpdateSUSPRM assemblyWe have positioned the guide rod and the
wire-stand-off on the optic in the axial
direction. 
  
  3747   Wed Oct 20 21:33:11 2010 KevinUpdatePSLQuarter Wave Plate Optimization[Suresh and Kevin]
We placed the quarter wave plate
in front of the 2W laser and moved the half
  
  3748   Wed Oct 20 21:43:25 2010 yutaUpdateCDSchecking whitening filters for MCs and messed up(Joe, Yuta)

Background:
 MC2ULSEN.pngMC2LRSEN.png 
  3749   Thu Oct 21 01:11:48 2010 ranaSummaryComputerselog change and rossa texI deleted
a bunch of categories from the elogd.cfg
  
  3750   Thu Oct 21 05:51:10 2010 kiwamuUpdateLockingno green beat note Still I didn't see any beat note signals..
 With a help from Suresh, Yuta
  
  3751   Thu Oct 21 10:44:56 2010 steveMetaphysicsTreasure1987 supernova tapes plus....?I'm cleaning out to make room for our new
optical cabinet. Are we keeping these? There
are  ~20  pieces of 10" od
 P1060932.JPG 
  3752   Thu Oct 21 12:15:02 2010 ranaUpdatePEM6.9 Mag EQ in Gulf of California

   
        
            Magnitude
  
  3753   Thu Oct 21 13:05:19 2010 KojiSummaryComputerselog change and rossa texThis is cool    
  3754   Thu Oct 21 15:59:28 2010 kiwamuUpdateLockingno green beat note : detailsLast night I tried searching for a beat
note signal with two different PD trans impedance
 bw.png 
  3755   Thu Oct 21 18:45:50 2010 KojiUpdatePSLFound the beat at 1064nm[Koji Suresh]
We found the beat at 1064nm. T(PSL)=26.59deg,
  
  3756   Thu Oct 21 19:10:39 2010 AidanUpdatePSLFound the beat at 1064nm    
  3757   Thu Oct 21 21:35:16 2010 yutaUpdateCDSfixed whitening filter switches(Joe, Yuta)

Summary:
 LLLR.pngContec23BO.png 
  3758   Fri Oct 22 00:59:01 2010 yutaUpdateCDSnew MEDM screens, new filter banks(whitening and dewhitening related)(Joe, Yuta)

Summary:
 HappySideMEDM.png 
  3759   Fri Oct 22 01:23:13 2010 KojiUpdatePSLFound the beat at 1064nm[Koji / Suresh]
We worked on the 1064 beating a bit
more.
 101021_beat.pdf 
  3760   Fri Oct 22 03:37:56 2010 KevinUpdatePSLQuarter Wave Plate Measurements[Koji and Kevin]
We measured the reflection from the
PBS as a function of half wave plate rotation
  
  3761   Fri Oct 22 15:06:43 2010 JenneUpdateSUSArts and Crafts!This afternoon I epoxied the guiderod and
wire standoff to the new PRM.  I also
epoxied the magnets that Suresh picked out
 StatusTable.png 
  3762   Fri Oct 22 16:59:21 2010 JenneUpdateElectronicsEpic TakeoverAs the suspension work winds down (we'll
be completely done once the ETMs arrive,
are suspended, and then are placed in the
  
  3763   Fri Oct 22 18:15:21 2010 kiwamuUpdateLockingGreen era: found a green beat note finallyfinally
we found it !
 green_beatnote.jpg 
  3764   Fri Oct 22 18:22:27 2010 AlbertoUpdateElectronicsEpic Takeover


   
        
            
  
  3765   Fri Oct 22 19:53:27 2010 yutaSummaryCDSconversion failure in digital filters(Rana, Joe, Yuta)

We now understand that we never succeeded
  
  3766   Fri Oct 22 21:28:27 2010 AidanUpdateLockingGreen era: found a green beat note finallyNice work!
  
  3767   Fri Oct 22 23:29:48 2010 yutaUpdateCDSfixed output filter switching(Joe, Yuta)

Summary:
  
  3768   Sat Oct 23 02:25:49 2010 KevinUpdatePSLQuarter Wave Plate Measurements


   
        
            
 fits.png 
  3769   Sat Oct 23 03:36:05 2010 yutaUpdateCDSfixed filters for C1SUS, C1RMS, C1MCS(Joe, Yuta)

Summary:
  
  3770   Sat Oct 23 14:42:01 2010 yutaSummaryCDSdamped MC suspensionsAfter replacing filters, MC suspensions
damped  last night.
Further measurement next time.
 dam.png 
  3771   Sun Oct 24 18:06:35 2010 kiwamuSummaryLockingsetup for green beat   green_beat_note.png 
  3772   Sun Oct 24 19:23:41 2010 ranaConfigurationelogELOG 2.8.0[SIZE=4][COLOR=blue][FONT=Comic Sans MS][B]I
stopped the ELOG and restarted us on 2.8.0.[/B][/FONT][/COLOR][/SIZE]
  
  3773   Sun Oct 24 19:55:50 2010 kiwamuUpdateElectronicslonely RF amplifier on ITMX table(Rana, Kiwamu) 



  
  3774   Mon Oct 25 02:14:38 2010 KojiSummaryLockingsetup for green beat- What is the actual photocurrent for the
beam1 and beam2? We don't care how much power
do you have before the BS, but care how much
  
  3775   Mon Oct 25 02:23:47 2010 KojiConfigurationelogELOG 2.8.0When I push the reply button, the raw html
shows up in the edit window and have to use
HTML to write the entry.
  
  3776   Mon Oct 25 02:25:21 2010 KojiUpdatePSLQuarter Wave Plate MeasurementsQ1. Suppose the laser beam has a certain
(i.e. arbitrary) polarization state but contains
only TEM00. Also suppose the PSB is perfect
  
  3777   Mon Oct 25 11:39:06 2010 JenneUpdateSUSMagnets glued to PRMThis morning I glued the magnets to the PRM.
 Now we wait, and tomorrow afternoon (at
the earliest), Suresh and I can balance the
 StatusTable.png 
  3778   Mon Oct 25 20:20:59 2010 yuta, JoeUpdateCDSDAQ channel number etc[U][B]Summary:[/B][/U]
  We split the old SDSEN filters to SDSEN,
SDSIDE, SDCOIL last week.
  
  3779   Mon Oct 25 23:10:06 2010 KojiUpdateIOOMC is now flashing[Suresh / Koji]
The MC
  
  3780   Mon Oct 25 23:59:37 2010 KojiConfigurationelogELOG 2.8.0 -> ELOG 2.7.5ELOG
reverted to 2.7.5 due to editing difficulties
  
  3781   Tue Oct 26 00:45:08 2010 ranaUpdatePSLNew NPRO Diagnostic Wiring   Untitled.png 