40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 75 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  10574   Tue Oct 7 00:18:12 2014 JenneUpdateLSCYgreen PSL alignment, ETMX strain reliefNo exciting progress today.  I did
PSL green alignment for the Yarm, although
I now think that the Xarm green needs realigning
  
  10578   Tue Oct 7 16:41:12 2014 JenneUpdateGeneralChiara not respondingI put a little script into ...../scripts/Admin
that will check the fullness of Chiara's
disk.  We only have the mailx program
  
  10581   Wed Oct 8 03:20:46 2014 JenneUpdateLSCDo we need AO for acquisition?As part of trying to determine whether
we require the AO path for lock acquisition,
or if we can survive on just digital loops,
 EstimatedNoisePerformance.pngBodeLSCvsALS.pngCARMnoise_7Oct2014.zip 
  10583   Wed Oct 8 03:49:42 2014 JenneUpdateLSCPRFPMI, other sign of CARM offsetOther thoughts from talking with Rana earlier:

    Is it possible to suppress
CARM motion enough that we can use just a
  
  10585   Wed Oct 8 15:31:31 2014 JenneUpdateCDSComputer statusAfter the Great Computer Meltdown of 2014,
we forgot about poor c0rga, which is why
the RGA hasn't been recording scans for the
  
  10588   Thu Oct 9 13:29:14 2014 JenneUpdatePSLPower outage II & recovery

    

       
            
  
  10591   Thu Oct 9 18:30:59 2014 JenneUpdateLSCCARM W/N TFsOkay, here (finally) is the optickle version.
I have the antispring case, starting
at 501pm and going roughly every 10pm down
 6x 
  10595   Fri Oct 10 03:25:11 2014 JenneUpdateLSCWhich side of optical spring are we on (simulation)I have a simulated version of the differences
that we expect to see between the 2 different
sides of the CARM resonance.  The point
 10x 
  10600   Mon Oct 13 16:08:49 2014 JenneUpdateCDSFrame builder is madI think the daqd process isn't running
on the frame builder. 
 Daqd_problem_maybe.png 
  10603   Mon Oct 13 21:20:56 2014 JenneUpdateLSCWhich side of optical spring are we on? (No progress)[Jenne, Diego]
In order to distinguish between the
spring and antispring sides of the CARM resonance,
  
  10607   Wed Oct 15 02:58:03 2014 JenneUpdateLSCWhich side of optical spring are we on? Some measurements.  Unclear meaning.
 
We tried both positive and negative
 PRFPMI_MC2injection_PosCARMoffset_REFLDC_TRX_response_14Oct2014_TRX.pdfPRFPMI_MC2injection_PosCARMoffset_REFLDC_TRX_response_14Oct2014_REFLDC.pdfPRFPMI_MC2injection_NegCARMoffset_REFLDC_TRX_response_14Oct2014_TRX.pdfPRFPMI_MC2injection_NegCARMoffset_REFLDC_TRX_response_14Oct2014_REFLDC.pdf 
  10609   Wed Oct 15 13:38:33 2014 JenneUpdateLSCCARM W/N TFsHere are the same plots, but the legend
also includes the arm power that we expect
at that CARM offset.  
 7x 
  10611   Wed Oct 15 17:18:10 2014 JenneUpdateComputer Scripts / ProgramsDataviewer fix with Ubuntu 12.04 
 I have modified the Dataviewer
launcher (which runs when you either click
  
  10612   Wed Oct 15 19:56:38 2014 JenneUpdateLSCWhich side of optical spring are we on? Meas vs Model I have plotted measured data from
last night (elog
10607) with a version of the result from
 AntispringModel_NegOffsetMeas_comparison.pdfSpringModel_NegOffsetMeas_comparison.pdf 
  10614   Wed Oct 15 22:39:17 2014 JenneUpdateLSCThe Plan [Rana, Jenne]
We're summarizing the discussions
of the last few days as to the game plan
  
  10615   Thu Oct 16 03:13:23 2014 JenneUpdateLSCPRMI on REFL165, and more The first thing I looked at tonight
was locking the PRMI on REFL 165.
I locked the PRMI (no arms), and
  
  10616   Thu Oct 16 03:18:48 2014 JenneUpdateCDSDaqd segfaulting again The daqd
process on the frame builder looks like it
  
  10622   Fri Oct 17 13:19:48 2014 JenneUpdateLSCPOP22 ?!?!We've seen this before, but we need to
figure out why POP22 decreases with decreased
CARM offset.  If it's just a demod phase
  
  10625   Fri Oct 17 17:52:55 2014 JenneUpdateLSCRAM offsetsLast
night I measured our RAM offsets and looked
at how those affect the PRMI situation. 
 16x 
  10626   Mon Oct 20 17:50:30 2014 JenneUpdateLSCCARM W/N TFs (Others were all wrong!)I realized today that I had been plotting
the wrong thing for all of my transfer functions
for the last few weeks! 
 7x 
  10630   Wed Oct 22 02:35:45 2014 JenneUpdateLSCEfforts at hopping PRMI to REFL165[EricQ, Jenne]
The first half of our evening
was spent working on CARM and DARM in PRFPMI,
  
  10633   Thu Oct 23 01:39:34 2014 JenneUpdateCDSDaqd "fixed"?Merging of threads. 
ChrisW figured out that it looks
like the problem with the frame builder is
  
  10634   Thu Oct 23 02:08:40 2014 JenneUpdateLSCIncreased DARM gainI changed the carm_cm_up.sh script so
that it requires fewer human interventions. 
Rather than stopping and asking for things
 6x 
  10636   Thu Oct 23 17:45:54 2014 JenneUpdateGeneralPianosa frozenNot sure why, but Pianosa was frozen. 
Also couldn't ssh or ping.  So, I hard
power cycled it.
  
  10637   Fri Oct 24 02:14:05 2014 JenneUpdateLSCIncreased DARM gain even more[Jenne, Diego]
We spent the afternoon working on
the new scan for IR resonance script. 
 DARM_23Oct2014.pdf 
  10642   Mon Oct 27 22:19:17 2014 JenneUpdateCDSc1iscex restartedI'm not sure why, but c1iscex did not want
to do an mxstream restart.  It would
complain at me that  "* ERROR: 
  
  10643   Tue Oct 28 01:12:57 2014 JenneUpdateSUSETMX bad :(ETMX is misbehaving again.  I went
to go squish his cable at the rack and at
the satellite box, but it still happened
  
  10644   Tue Oct 28 02:44:08 2014 JenneUpdateSUSETMX bad :(Okay, now ETMX's badness is a show-stopper. 
I'm not sure why, but after this last lockloss,
ETMX won't stay put.  Right now (as
  
  10652   Thu Oct 30 01:21:37 2014 JenneUpdateLSCNo MICH in REFL165[Koji, Jenne, Diego]
Summary: 
 MICH_to_REFL165_29Oct2014.pdf 
  10686   Fri Nov 7 16:15:53 2014 JenneUpdateLSC3F RFPD RF spectraI have found an SHP-150, but no SHP-175's
(also, several 200's, and a couple of 500's).
Why do you say the SHP-150 isn't
  
  10696   Tue Nov 11 03:48:46 2014 JenneUpdateLSC3f DRMII was
able to lock the DRMI on 3f signals this
evening, although the loops are not stable,
 SensMatMeas_10Nov2014_DRMI.pngSensMatMeas_10Nov2014_PRMI.png 
  10701   Wed Nov 12 03:22:23 2014 JenneUpdateLSC3f DRMI sensing matKoji pointed out something to me that I
think he had told me ages ago, and Rana alluded
to last night:  Since I'm not tuning
 8x 
  10703   Wed Nov 12 18:08:35 2014 JenneUpdateLSCRIN in transmission a problem?In my previous meditations about RIN, particularly
elog
10258, I was only thinking about the
 RIN_TRX_TRY_MCtrans_12Nov2014_zip.xml.gzRIN_TRX_TRY_MCtrans_12Nov2014.pdfRINcontribution_12Nov2014_linearXscale.pngRINcontribution_12NOv2014_logXscale.png 
  10709   Thu Nov 13 04:28:28 2014 JenneUpdateLSCRIN in transmission a problem?[Jenne, Rana, Koji]
We
did some thinking on what could be causing
 zippyzip.zipRIN_TRX_TRY_IPPOS_NoLens_12Nov2014.pdf 
  10712   Thu Nov 13 23:42:01 2014 JenneUpdateLSCRIN vs. SeismicAfter Kate, Diego and I moved the seismometers
to the corner for a huddle test (see elog
10711), I wanted to check the coherence
 Seismic_TRXTRYandMC_13Nov2014.pdf 
  10717   Fri Nov 14 15:45:34 2014 JenneUpdateCDSComputers back up after reboot[Jenne, Q]
Everything
  
  10718   Fri Nov 14 17:08:17 2014 JenneUpdateLSCRIN vs. SeismicT-240 has a different convention than we
use.  It assumes that North is aligned
with the Y-axis.  Since this is the
  
  10719   Fri Nov 14 19:28:33 2014 JenneUpdateSUSASS gain reduced for Yarm[Koji, Jenne]
We noticed last night that the yarm
couldn't handle the old nominal gain for
  
  10724   Mon Nov 17 23:04:51 2014 JenneUpdatePSLAligned PMCI aligned the beam into the PMC, mostly
in yaw.  Don't know why it drifted,
but it was annoying me, so I fixed it.
  
  10725   Tue Nov 18 15:20:58 2014 JenneUpdateLSCSome lockloss plots from PRFPMIElog from ~5am last night:
Tonight was just several trials
of PRFPMI locking, while trying to pay more
 8x 
  10726   Tue Nov 18 17:11:30 2014 JenneUpdateLSCSome lockloss plots from PRFPMII am still staring at / trying to figure
out the latter 4 locklosses posted earlier. 
But, I have just included the transmission
  
  10727   Tue Nov 18 22:34:28 2014 JenneUpdateLSCSome other plots from PRFPMI


   
        
            
 TRXmax98_TRYmax107_CARMdarmOnALS_0carmOffset.pngZoom_with_POP22.pngZoom_with_POP110.pngZoom_with_ErrSigs.png 
  10734   Tue Nov 25 02:04:19 2014 JenneUpdateLSCPRFPMI tonight - need some PRCL and MICH tuning at high arm powersTake-away for the night:  We need
to do some more fine-tuning of the PRCL and
MICH loops when we have arm resonance.
 HighPower_7pt3sec_Powers.pngHighPower_7pt3sec_ErrAndCtrls.pngHighPower_7pt3sec_AuxErrs.pngCARMDARMonALScommdiff_StayingAbove5_upTo175_24Nov2014.png 
  10736   Wed Nov 26 05:15:48 2014 JenneUpdateLSCPRFPMI tonight PRMI 100Hz osc?[Jenne, EricQ]
Just to get our day started right,
we tweaked up the alignment of the Ygreen
 PRFPMI_currentErrSigs_25Nov2014.pdf 
  10737   Wed Nov 26 22:24:28 2014 JenneUpdateLSCDARM loop improved, other work[Jenne, Koji]
We have done several things this
evening, which have incrementally helped
 8x 
  10740   Mon Dec 1 16:34:20 2014 JenneUpdateGeneralIFO wake-up 
 After its' several days of
rest, it is time to wake up the IFO. 
  
  10742   Mon Dec 1 17:19:22 2014 JenneUpdateGeneralPMC align[Diego, Jenne]
Tweaked up the input alignment to
the PMC.  Now we're at 0.785.
  
  10743   Mon Dec 1 17:43:22 2014 JenneUpdateLSCReset Yarm trans normalizationAfter Koji and I reset the transmission
normalizations last Friday, he did some alignment
work that increased the Yarm power. 
  
  10746   Tue Dec 2 02:44:45 2014 JenneUpdateLSCTried cav pole compensation trick - fail[Jenne, Diego]
First, random notes:

    saw a violin peak in CARM
  
  10751   Wed Dec 3 21:41:12 2014 JenneUpdateComputer Scripts / ProgramsMatlab license updatedIt seems that the old Matlab servers went
down a week or so early, so I have updated
the Matlab license information in 
  
ELOG V3.1.3-