Entry  Fri Oct 12 01:56:26 2012, kiwamu, Update, General, Alignment situation of interferometer  
Entry  Thu Oct 11 21:26:40 2012, janosch, Update, General, PRC phase maps 7x
Entry  Thu Oct 11 00:28:30 2012, Den, Update, SUS, diagonalization mc1_new.pdfmc123_new.pdf
    Reply  Thu Oct 11 01:30:11 2012, Den, Update, SUS, diagonalization mc1_coils.pdf
    Reply  Thu Oct 11 14:40:20 2012, Den, Update, SUS, diagonalization mc1.pdf
Entry  Thu Oct 11 12:02:15 2012, Den, Update, IOO, FSS fss.png
Entry  Wed Aug 15 17:23:22 2012, jamie, Update, CDS, front end IOP models changed to reflect actual physical hardware 
    Reply  Thu Oct 11 11:57:40 2012, jamie, Update, CDS, all IOP models rebuild, install, restarted to reflect fixed ADC/DAC layouts 
Entry  Thu Oct 11 11:20:05 2012, janosch, Update, General, beam shape simulation, PRC 
Entry  Wed Oct 10 21:50:39 2012, SUS_Diagonalizer, Update, SUS, Optics kicked 
    Reply  Thu Oct 11 00:22:58 2012, SUS_Diagonalizer, Update, SUS, Optics kicked 
Entry  Wed Oct 10 15:31:59 2012, Rijuparna, Update, , cavitymode scan 
    Reply  Wed Oct 10 15:46:23 2012, Jenne, Update, , cavitymode scan 
Entry  Fri Sep 14 01:18:51 2012, rana, Update, COC, 2 Layout Changes 
    Reply  Mon Sep 17 18:04:01 2012, Steve, Update, COC, 2 Layout Changes IMG_1635.JPG
    Reply  Wed Oct 10 08:36:47 2012, Steve, Update, COC, special mirror mounts holder 10101201.PDF
Entry  Wed Oct 10 02:20:34 2012, rana, Update, SUS, Optical Lever QPD mods C1-CORE_OPTICS_SUM_DATA_ALL_TIME_0-1033801216-86400.png
Entry  Tue Oct 9 23:12:56 2012, Jenne, Update, LSC, 11MHz reconnected to EOM 
    Reply  Wed Oct 10 02:15:14 2012, rana, Update, LSC, 11 MHz reconnected to EOM 
Entry  Wed Oct 10 00:18:58 2012, Jenne, Update, Locking, REFL camera aligned 
Entry  Tue Oct 9 17:16:14 2012, Den, Update, SUS, diagonalization mc123_rms.pdfmc1_diag.pdfmc123_rms.pdf
    Reply  Tue Oct 9 17:33:37 2012, jamie, Update, SUS, diagonalization 
Entry  Mon Sep 24 16:59:31 2012, Jenne, Update, VAC, Doors on, ready to pump 
    Reply  Mon Sep 24 17:47:05 2012, Steve, Update, VAC, ready to pump 
       Reply  Tue Sep 25 17:21:01 2012, Steve, Update, VAC, pumpdown completed pd73.pngpd73b.png
          Reply  Wed Sep 26 11:03:04 2012, Steve, Update, VAC, pumpdown completed 40mpd73md1.png28datm.png
             Reply  Mon Oct 1 09:02:17 2012, Steve, Update, VAC, pumpdown reached vacuum normal pd73md6.pngpd73md6b.png
                Reply  Tue Oct 2 09:13:16 2012, Steve, Update, VAC, RGA scan at day 7 pd73md7.png
                Reply  Tue Oct 9 09:29:10 2012, Steve, Update, IOO, this is where we are 15days.png
    Reply  Mon Oct 8 22:07:46 2012, rana, Update, SUS, Doors on, ready to pump 20120921_200637.jpg
Entry  Tue Oct 2 15:14:54 2012, jenne, jamie, Update, IOO, PZT diagnosis 
    Reply  Tue Oct 2 16:32:43 2012, Jenne, Update, IOO, PZT diagnosis 
       Reply  Thu Oct 4 01:06:52 2012, Jenne, Update, IOO, PZT diagnosis 
          Reply  Mon Oct 8 14:19:17 2012, Jenne, Update, IOO, PZT diagnosis - not fixed yet 
             Reply  Mon Oct 8 18:45:48 2012, Jenne, Update, IOO, PZT diagnosis - not fixed yet, possible solution 
                Reply  Mon Oct 8 21:42:17 2012, Jenne, Update, IOO, PZT diagnosis - not fixed yet, possible solution 
                Reply  Tue Oct 9 00:25:33 2012, Jenne, Update, IOO, PZTs - hacky solution in place!! 
Entry  Mon Oct 8 23:58:57 2012, Jenne, Update, SAFETY, Control room emergency lights came on 
Entry  Sun Oct 7 23:39:10 2012, Den, Update, Modern Control, state estimation est_time.pngest_freq.pdf
    Reply  Mon Oct 8 09:51:30 2012, rana, Update, Modern Control, state estimation 
       Reply  Mon Oct 8 12:34:52 2012, Den, Update, Modern Control, state estimation 
Entry  Mon Oct 8 10:56:59 2012, Jenne, Update, SUS, ETMX slow machine dead?? 
    Reply  Mon Oct 8 11:44:21 2012, Jenne, Update, SUS, ETMX slow machine fine 
Entry  Mon Oct 8 11:15:53 2012, Jenne, Update, PSL, PMC and FSS had a weird weekend PMC_sawtooth_FSSweird_8Oct2012_10dayTrend.pngPMC_sawtooth_FSSweird_8Oct2012_1dayTrend.pngPMC_sawtooth_FSSweird_8Oct2012_1dayTrend.png
Entry  Sun Oct 7 12:11:00 2012, Aidan, Update, Computers, Rebooted cymac0  
    Reply  Mon Oct 8 09:45:28 2012, jamie, Update, Computers, Rebooted cymac0  
Entry  Tue Oct 2 07:45:49 2012, Steve, Update, SUS, MC2 & PRM sus damping restored 
    Reply  Wed Oct 3 07:41:23 2012, Steve, Update, SUS, MC2 sus damping restored 
       Reply  Wed Oct 3 23:24:05 2012, Koji, Update, SUS, MC2 sus damping restored 
       Reply  Sun Oct 7 15:05:42 2012, Den, Update, SUS, MC2 sus damping restored mc2.png
Entry  Tue Sep 18 20:32:42 2012, Manasa, Configuration, PSL, AOM installation 
    Reply  Wed Sep 19 11:39:37 2012, Manasa, Configuration, PSL, AOM installation ALC_25.png
       Reply  Wed Sep 19 15:41:27 2012, Manasa, Configuration, PSL, AOM installation 
          Reply  Wed Sep 19 23:17:25 2012, rana, Configuration, PSL, AOM installation 
             Reply  Thu Sep 20 01:29:04 2012, Manasa, Configuration, PSL, AOM installation TEK00000.PNG
                Reply  Fri Sep 21 12:12:56 2012, Manasa, Configuration, PSL, AOM installation PSL.png
                   Reply  Tue Oct 2 16:15:22 2012, Manasa, Configuration, PSL, AOM installation psl_aom.png
                      Reply  Wed Oct 3 16:52:16 2012, Manasa, Configuration, PSL, AOM installation 
                         Reply  Wed Oct 3 23:36:54 2012, Koji, Configuration, PSL, AOM installation PMCTRANS.png
                            Reply  Thu Oct 4 17:54:59 2012, Manasa, Configuration, PSL, AOM installation 
                               Reply  Thu Oct 4 18:48:04 2012, janosch, Configuration, PSL, AOM installation 
                                  Reply  Thu Oct 4 20:57:43 2012, Manasa, Configuration, PSL, AOM installation 
                                     Reply  Thu Oct 4 22:16:28 2012, Koji, Configuration, PSL, AOM installation 
                                        Reply  Fri Oct 5 18:08:17 2012, Manasa, Configuration, PSL, AOM installation 
Entry  Fri Oct 5 16:21:48 2012, Steve, Update, General, freshmen visiters IMG_1693.JPGIMG_1694.JPG
Entry  Fri Oct 5 14:53:29 2012, Jenne, Update, PSL, TTFSS board not fully seated! 
Entry  Thu Oct 4 08:39:58 2012, Steve, Update, General, power outage Oct4R2012.png
    Reply  Thu Oct 4 14:04:21 2012, jamie, Update, CDS, front ends back up 
       Reply  Thu Oct 4 14:08:49 2012, jamie, Update, SUS, suspensions damped 
          Reply  Thu Oct 4 22:27:54 2012, Koji, Update, SUS, How about the slow machines? 
             Reply  Thu Oct 4 22:35:16 2012, Den, Update, SUS, How about the slow machines? 
                Reply  Fri Oct 5 04:34:31 2012, rana, Update, SUS, How about the slow machines? 
       Reply  Fri Oct 5 14:40:55 2012, Steve, Update, VAC, RGA scan after power outage afterpoweroutaged10.pngpd73m10d.png
Entry  Fri Oct 5 00:29:34 2012, Den, Update, PEM, readout box power 
    Reply  Fri Oct 5 11:11:00 2012, Den, Update, PEM, readout box power 
Entry  Mon Oct 1 19:21:03 2012, rana, Configuration, PEM, changed PEM DQ channels 
    Reply  Fri Oct 5 01:36:49 2012, Den, Configuration, PEM, changed PEM DQ channels 
Entry  Thu Oct 4 23:01:49 2012, Rijuparna, Configuration, , cavitymode scan diagram1.pdf
Entry  Thu Oct 4 22:16:40 2012, Den, Update, PSL, PMC is locked 
Entry  Wed Oct 3 18:45:51 2012, jamie, Update, IOO, wiki page for active IO tip-tilts 
Entry  Wed Oct 3 15:58:57 2012, Steve, Configuration, IOO, SOS coil drivers moved SOScoildriversTT.jpgIMG_1680.JPG
Entry  Wed Oct 3 11:43:33 2012, Steve, Update, SAFETY, safety training 
Entry  Wed Aug 8 19:54:06 2012, Manasa, Configuration, IOO, MC trans optics configured Pic1.png
    Reply  Wed Aug 8 22:12:30 2012, rana, Configuration, IOO, MC trans optics configured 
       Reply  Wed Aug 8 22:17:43 2012, Manasa, Configuration, IOO, MC trans optics configured 
          Reply  Fri Aug 10 09:54:51 2012, Manasa, Configuration, IOO, MC trans optics configured 
             Reply  Fri Aug 10 11:05:33 2012, jamie, Configuration, IOO, MC trans optics configured 
                Reply  Fri Aug 10 15:05:52 2012, Manasa, Configuration, IOO, MC trans optics configured 
                   Reply  Thu Aug 16 17:28:51 2012, Manasa, Configuration, IOO, MC trans optics configured 
                      Reply  Tue Oct 2 14:20:33 2012, Manasa, Configuration, IOO, PDA255 not working 
Entry  Mon Apr 30 21:05:32 2012, Jenne, Update, SUS, ETMY oplev power supply dead 
    Reply  Mon Apr 30 21:24:43 2012, Koji, Update, SUS, ETMY oplev power supply dead 
       Reply  Mon Apr 30 22:41:34 2012, Jenne, Update, SUS, ETMY oplev power supply dead 
          Reply  Fri May 18 11:19:17 2012, steve, Update, SUS, ETMY oplev laser is dead 
             Reply  Tue May 22 08:03:01 2012, steve, Update, SUS, ETMY oplev gets new laser 
                Reply  Tue May 29 15:55:22 2012, steve, Update, SUS, ETMY oplev spot size reduced ETMYoplev.jpgIMG_1243.JPG
                   Reply  Tue May 29 21:34:08 2012, Jenne, Update, SUS, ETMY oplev spot size reduced 
                   Reply  Wed Jun 6 14:36:58 2012, steve, Update, SUS, ETMY oplev work finished 
                   Reply  Mon Oct 1 17:03:01 2012, steve, Update, SUS, ETMY oplev relayed IMG_1673oplevETMY.jpg
Entry  Mon Oct 1 16:05:01 2012, jamie, Update, CDS, mx stream restart required on all front ends 
Entry  Mon Oct 1 13:11:43 2012, Jenne, Update, IOO, PZT inspection elogs 
Entry  Fri Sep 28 21:17:41 2012, Koji, Update, IOO, MC WFS adjustment MC_WFS_12h.png
    Reply  Mon Oct 1 11:08:25 2012, Jenne, Update, IOO, MC WFS adjustment 
Entry  Mon Oct 1 07:25:48 2012, Steve, Update, SUS, MC2 & ETMX sus damping restored 
Entry  Mon Aug 13 15:31:09 2012, steve, Update, General, larger optical tables at the ends ETMYtable.jpgETMY4X3.jpg
    Reply  Mon Aug 13 18:00:30 2012, jamie, Update, General, larger optical tables at the ends 
       Reply  Tue Aug 14 15:58:44 2012, Jenne, Update, General, Translation to English: larger optical tables at the ends 
    Reply  Wed Aug 15 16:01:47 2012, steve, Update, General, larger optical tables at the ends ? bottleneck.jpg
       Reply  Wed Aug 22 11:41:20 2012, steve, Update, General, grout plate for optical table at the ends IMG_1561.JPG08231201.PDF
          Reply  Thu Sep 27 19:03:06 2012, Manasa, Update, 40m Upgrading, New ETMX layout - Version 1.0 ETMX_OldNew.png
             Reply  Thu Sep 27 20:05:57 2012, Koji, Update, 40m Upgrading, New ETMX layout - Version 1.0 
                Reply  Fri Sep 28 07:49:30 2012, Steve, Update, 40m Upgrading, New ETMX layout - Version 1.0 
Entry  Thu Sep 27 17:00:41 2012, Eric Gustafson, Update, LSC, 40 meter photodiode frequency response measurement system installation 
Entry  Thu Sep 27 13:05:55 2012, Eric Gustafson, Update, LSC, 40 meter photodiode frequency response measurement system installation 
    Reply  Thu Sep 27 16:26:11 2012, Steve, Update, LSC, RF fibre protection in cable trays 
Entry  Wed Sep 26 23:55:14 2012, Jenne, Update, IOO, WFS centered 
Entry  Tue Sep 25 22:40:55 2012, Jenne, Update, IOO, IPANG ND filter installed 
    Reply  Wed Sep 26 16:59:30 2012, jamie, Update, IOO, IPANG ND filter installed 
Entry  Wed Sep 26 01:10:34 2012, Jenne, Update, IOO, PZT2 not working?!?! MC back to normal 
Entry  Fri Sep 21 20:48:24 2012, Jenne, Update, General, POP in-vac optics aligned, POY beam coming out of vac 
    Reply  Fri Sep 21 22:25:44 2012, Mike J., Update, General, POX, POY, PR2 pics 10x
    Reply  Mon Sep 24 23:45:39 2012, rana, Update, General, POP in-vac optics aligned, POY beam coming out of vac 
       Reply  Tue Sep 25 14:29:07 2012, Jenne, Update, General, POP in-vac optics aligned, POY beam coming out of vac 
Entry  Mon Sep 24 20:28:13 2012, rana, Summary, elog, restarted elog: was unresponsive 
Entry  Mon Sep 24 10:27:50 2012, Steve, Omnistructure, General, do not leave stuff on optical table tops 
Entry  Sun Sep 23 22:40:48 2012, Den, Update, Modern Control, MC_L locking LQR_MCL.pdf
Entry  Fri Sep 21 22:43:51 2012, Den, Update, SUS, TT alignment 6x
Entry  Thu Sep 20 17:05:26 2012, Jenne, Update, General, REFL, IPANG are coming out of the vac 
    Reply  Thu Sep 20 20:07:38 2012, Jenne, Update, General, REFL, IPANG are coming out of the vac 