  5300   Thu Aug 25 08:12:09 2011 steveUpdateSUSETMY & ITMY wiped, replaced, vac door on


   
        
            
  
  12961   Mon May 1 17:14:58 2017 SteveUpdateCamerasETMY & MC2 ccd cameras removedMC2 ccd camera is replaced by Olympus 570
zoom temporarly.

So as the ETMY ccd camera is replaced
  
  8637   Fri May 24 02:12:50 2013 AnnalisaUpdate40m upgradingETMY - Mode Matching for green 
 Mode
Matching calculation for green beam - Yarm
 ModeMatchingGreen.jpgModeMatchingGreenZoom.jpgXYpath.jpg 
  8638   Fri May 24 11:38:00 2013 KojiUpdate40m upgradingETMY - Mode Matching for greenI got confused. Is the mode calculation
in the cavity correct? 
Are you sure the wavelength in the
  
  8639   Fri May 24 12:50:25 2013 AnnalisaUpdate40m upgradingETMY - Mode Matching for green

    

       
            
  
  8645   Sat May 25 02:03:48 2013 AnnalisaUpdate40m upgradingETMY - Mode Matching for green - new calculation Mode
matching calculation for green - Yarm
I
 ModeMatchingGreenNEW.jpgModeMatchingGreenZoomNEW.jpgXYpathNEW.jpgphoto1.JPGphoto2.JPG 
  8662   Fri May 31 11:15:01 2013 AnnalisaUpdateendtable upgradeETMY - Mode Matching for green - new calculation Since the beam waist after the Faraday
had changed since the last time I measured
it (maybe alignment changed a bit), I made
  
  8652   Tue May 28 22:11:23 2013 AnnalisaUpdate40m upgradingETMY - Yarm shutter cable 
 For some strange reason the
Yarm shutter cable runs up to the POY table,
  
  8751   Wed Jun 26 00:15:51 2013 AnnalisaUpdateGreen LockingETMY - green locking and beat note setup[Koji, Annalisa]
Alignment improving

    The alignment of the green
  
  8628   Thu May 23 12:02:48 2013 SteveUpdateendtable upgradeETMY - oplev Temporary oplev in place. The spot
on the qpd is still big. My two lens solution
did not work.
 ETMYopl.jpg 
  8655   Thu May 30 11:10:00 2013 SteveUpdateendtable upgradeETMY - oplev

    

       
            
 ETMYoplev.jpg 
  8660   Thu May 30 20:45:53 2013 AnnalisaUpdateendtable upgradeETMY - oplev

    

       
            
  
  8594   Fri May 17 00:32:32 2013 AnnalisaUpdate40m upgradingETMY - progress[Rana, Annalisa] 
 GREEN
 IMG_0536.JPG 
  8597   Fri May 17 18:24:04 2013 AnnalisaUpdate40m upgradingETMY - progressI aligned the green beam into the Faraday.
I needed an HWP to have the right polarization
for the light entering the Faraday itself.
  
  8622   Thu May 23 00:16:32 2013 AnnalisaUpdate40m upgradingETMY - progress [Annalisa, Koji] 
 GREEN
 TransMonAndOplev.jpg 
  8768   Thu Jun 27 17:41:08 2013 AnnalisaUpdateGreen LockingETMY -beat note found! 
 Y
 beat_note.JPG 
  16687   Mon Feb 28 15:51:07 2022 Ian MacMillanUpdateSUSETMY 1Y4 Electronics Replacement[Paco, Ian]

paco helped me wire the ETMY 1Y4
rack. We wired the following (copied from
 IMG_0865.jpgIMG_0867.jpgIMG_0868.jpgIMG_0866.jpg 
  16695   Thu Mar 3 04:11:36 2022 KojiUpdateSUSETMY 1Y4 Electronics ReplacementFor the Y-end electronics replacement,
we want to remove unused power supplies.
In fact, we already removed the +/-5V supplies
 PXL_20220303_082726693.jpgPXL_20220303_082752494.jpgPXL_20220303_082744464.jpg 
  16696   Thu Mar 3 04:24:23 2022 KojiUpdateSUSETMY 1Y4 Electronics ReplacementThe DC power strip at Y-end was connected
to the bottom two Sorensen power supplies.
They are configured to provide +/-18V.
 PXL_20220303_094421604.jpgPXL_20220303_094435127.jpg 
  16699   Thu Mar 3 17:21:11 2022 Ian MacMillanUpdateSUSETMY 1Y4 Electronics Replacement[Koji, Ian]

1) We attached the 30 coil driving
cables to the vacuum feed through to the
  
  16703   Sat Mar 5 02:03:46 2022 KojiUpdateSUSETMY 1Y4 Electronics ReplacementOplev saga

Summary 

- The new coil driver had not enough
 6x 
  16738   Mon Mar 21 14:22:52 2022 AnchalUpdateSUSETMY Alignmnet offsets needed to be changedI'm not sure why but the PIT and YAW
offset values of +2725 and -2341 were not
sufficient for the reflected OPLEV beam to
  
  14569   Thu Apr 25 00:30:45 2019 gautamUpdateSUSETMY BR mode We briefly talked about the bounce and
roll modes of the SOS optic at the meeting
today. 
 ETMY_sensorSpectra_BRmode.pdfETMY_sensorSpectra_BRmode.pdfETMX_sensorSpectra_BRmode.pdfIMG_5993.JPG 
  2259   Thu Nov 12 17:24:29 2009 Koji, Joe, PeterConfigurationCDSETMY CDS test startedWe started the test of the new CDS system
at ETMY.
The plan is as follows:
  
  2181   Thu Nov 5 16:24:59 2009 KojiUpdateCDSETMY CDS test stuffJoe, Peter, Jay, Koji, Rana
We put the new CDS stuff at Y end
1Y9 rack.
  
  1321   Wed Feb 18 21:03:22 2009 ranaUpdateCamerasETMY Camera work not elogged!The control room video is showing us a
false ETMY image. Who worked on the ETMY
camera or video today??!!
  
  14075   Tue Jul 17 01:07:40 2018 gautamUpdateSUSETMY EQ stopsFor the heater setup on EY table, I EQ-stopped
ETMY. Only
  
  14630   Wed May 22 11:53:50 2019 gautamUpdateSUSETMY EQ stops backed outYesterday we noticed that the POS and SIDE
eigenmodes were degenerate (with 1mHz spectral
resolution). Moreover, the YAW peak had shifted
 ETMY_eigenmodes.pdf 
  14629   Tue May 21 21:33:27 2019 gautamUpdateSUSETMY HR face cleaned[koji,
gautam]

We executed this plan. Photos are
  
  4057   Wed Dec 15 13:36:44 2010 josephbUpdateCDSETMY IO chassis updateI gave
Alex a sob story over lunch about having
to go and try to resurrect dead VME crates. 
  
  4058   Wed Dec 15 14:23:32 2010 KojiUpdateCDSETMY IO chassis updateGreat!

I wish this board works fine at least for
several days...
  
  14625   Mon May 20 17:12:57 2019 gautamUpdateSUSETMY LL adjustmentFollowing the observation that the response
in the LL shadow sensor was lower than that
of the others, I decided to pull it out a
  
  12349   Thu Jul 28 17:48:17 2016 gautamUpdateGeneralETMY LR magnet broke offWhile ETMX magnets were curing, I wanted
to try and suspend ETMY in the endchamber,
put in the OSEMS and see if the magnets aligned
  
  14447   Mon Feb 11 16:38:34 2019 gautamUpdateLSCETMY OL calibration updatedSince we changed the HeNe, I updated the
calibration factors, and accepted the changes
in the SDF.
 OL_calib_ETMY_PERROR.pdfOL_calib_ETMY_YERROR.pdf 
  11667   Mon Oct 5 11:25:21 2015 ericqUpdateSUSETMY OL laser deadGautam alerted me that the Y arm looked
like it was being dithered, even though the
ASS was turned off. I found that the ETMY
 ETMY-OLSUM.png 
  11668   Mon Oct 5 16:41:22 2015 SteveUpdateSUSETMY OL laser replacedThis JDSU 1103P laser, sn P892324 lived
for 2 years. It's power output is 0.05
mW now
  
  14409   Sat Jan 19 15:33:18 2019 gautamUpdateSUSETMY OSEMs faultyAfter diagnosis with the tester box, as
I suspected, the fully open DC voltages on
the two problematic channels, LL and UR,
 Screen_Shot_2019-01-19_at_3.32.35_PM.pngETMY_sensors_1231832635.pdf 
  14411   Tue Jan 22 20:36:53 2019 gautamUpdateSUSETMY OSEMs faultyShort update on latest Satellite box woes.


I checked the resistance
of all 5 OSEM coils on ETMY using a DB25
  
  12430   Mon Aug 22 18:04:24 2016 gautamUpdateSUSETMY OSEMs inserted[Johannes, gautam]

We worked on trying to insert the
OSEMs in the optimal positions such that
  
  8749   Tue Jun 25 23:49:04 2013 AnnalisaUpdateSUSETMY OplevI had some problem with the Oplev Servo
today. I was working at the mode matching
fine tuning and I left the Oplev servo enabled
  
  12750   Tue Jan 24 17:52:15 2017 CraigUpdateOptical LeversETMY Oplev HeNe is replacedSteve, Craig, Gautam

Today Steve replaced the ETMY He/Ne
sr P919645 OpLev laser with sr P947049 and
 6x 
  13018   Tue May 30 13:36:58 2017 SteveUpdateOptical LeversETMY Oplev HeNe is replacedFinally I reallized what is killing the
ETMY oplev laser. Wrong 
power supply, it  was driving the
 oplevETMY120d.png 
  12747   Mon Jan 23 17:24:26 2017 SteveUpdateOptical LeversETMY Oplev HeNe is running hotETMY He/Ne 1103P  body temp is 
~45 C The laser was seated loosely 
in the V-mount with black rubber padding.
 ETMY_oplev__lasers.png 
  14402   Tue Jan 15 18:16:00 2019 gautamUpdateOptical LeversETMY Oplev HeNe needs replacementPerhaps the ETMY Oplev HeNe is also giving
up - the power has fallen by ~30% over 1
year (Attachment #2), nearly twice as much
 OLRIN.pdfOLsums.png 
  12746   Mon Jan 23 15:16:52 2017 gautamUpdateOptical LeversETMY Oplev HeNe needs to be replacedOn the control room monitors, I noticed
that the IR TEM00 spot was moving around
rather a lot in the Y arm. The
 ETMY_Oplev.pdf 
  13267   Tue Aug 29 15:04:59 2017 gautamUpdateSUSETMY Oplev PIT loop gain changedLast night, while we were working on the
ALS, I noticed the GTRY spot moving around
(in PITCH) on the CCD monitor in the control
 ETMY_OLPIT.pdfGTR_comparison.pdf 
  13060   Mon Jun 12 17:42:39 2017 gautamUpdateASSETMY Oplev Pentek board pulled outAs part of my Oplev servo investigations,
I have pulled out the Pentek Generic Whitening
board (D020432) from the Y-end electronics
  
  499   Sun May 25 22:33:00 2008 ranaUpdateSUSETMY Oplev WorkI found the ETMY table in disarray and put
the panels back on and put the ETMY OL laser
back on the quad.
  
  11526   Mon Aug 24 16:10:07 2015 ericqUpdateSUSETMY Oplev laser power is fallingToday I noticed the box around the ETMY
oplev sum flashing red, as it dipped below
1k. I don't recall seeing this recently,
 ETMYsum_trend.pdf 
  11527   Mon Aug 24 16:46:49 2015 ericqUpdateSUSETMY Oplev laser power is fallingRepeated for all optics, ETMY seems like
the only one sharply dropping for now (PRM
is all over the place and hard to gauge,
 OLsum_trend.pdf 