40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 68 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  8740   Tue Jun 25 00:13:00 2013 JenneUpdateCDSProto-ASC implemented in ASS modelI have finished my work on the LSC and
ASS models for now. The triggering is all
implemented, and should be ready to go. 
  
  8753   Wed Jun 26 04:38:02 2013 JenneUpdateLSCPRCL locking again - ASC successWith Rana's help/supervision/suggestions,
I have closed the loop on the PRMI ASC servo
with the new QPD.  I think I've
 PRMI_ASC_yawOnly_powerSpectra_25June2013.pdfPRMI_ASC_yawOnly_25June2013_mag.pdfPRMI_ASC_yawOnly_25June2013_phase.pdfPRMI_ASC_yawOnly_25June2013_coherence.pdfSensMatMeas_26June2013.png 
  8756   Wed Jun 26 13:37:13 2013 JenneUpdateIOOMC very misaligned - put backNot sure why it was so poorly aligned,
since the misalignment "event"
happened while we were all away at lunch,
  
  8764   Thu Jun 27 15:50:03 2013 JenneUpdatePEMBLRMS are going crazyThe BLRMS are totally crazy today! 
I'm not sure what the story is, since it's
been this way all day (so it's not an earthquake,
 WeirdBLRMSincrease_27June2013_rawSeis.pngWeirdBLRMSincrease_27June2013_lowFreqBLRMS.pngWeirdBLRMSincrease_27June2013_Gur1xBLRMS.png 
  8766   Thu Jun 27 17:04:49 2013 JenneUpdatesafetyNitrogen bottle too hot - overpressuredAll of us in the control room / desk area
heard a sudden whoosh of air a few minutes
ago.  It kind of sounded like a pressure
  
  8767   Thu Jun 27 17:09:41 2013 JenneUpdateLSCPRCL locking again - POP PIT workLast night before dinner, I copied over
the ASC yaw servo filters to the ASC pitch
filter bank.  Using ASC gain of +0.001,
 MeasuredVsModeledASCyaw.png 
  8780   Fri Jun 28 02:12:41 2013 JenneUpdateLSCPRCL locking again - ASC workRana had the epiphany that I didn't have
any antiwhitening for my POP QPD.  Ooops. 
We looked at the schematic for the
 PRMI_ASC_powerSpectra_27June2013.pdfScreenshot-Untitled_Window.png 
  8781   Fri Jun 28 02:23:00 2013 JenneUpdateLSCNeed to measure sensing matrix at REFL165[Lisa, Rana, Jenne]
Lisa asked to see a model of the
PRMI sensing matrix with REFL165 included,
 SensMatModel_28June2013_InclREFL165.png 
  8788   Mon Jul 1 23:27:07 2013 JenneUpdateLSCSensing Matrix vs. Xarm sweepI have modeled the PRMI sensing matrix
as I bring the Xarm into resonance. 
In optickle, I have the PRMI on sideband
  
  8790   Tue Jul 2 02:29:47 2013 JenneUpdateLSCSensing Matrix vs. Xarm sweepHere is the Sensing Matrix movie (sorry
for the iffy quality - my movies usually
come out better than this):
  
  8805   Mon Jul 8 15:31:48 2013 JenneUpdateASCPOP QPD calibration prepI am prepping to do the POP QPD calibration,
and so have turned off the POP QPD, and put
it onto a micrometer stage.  My plan
  
  8810   Tue Jul 9 11:41:22 2013 JenneUpdateASCPOP QPD calibration attemptI was bad, and forgot to elog the most
important part of my work yesterday - that
I had rotated the POP QPD by 90 degrees,
  
  8812   Tue Jul 9 16:08:32 2013 JenneUpdateASCPOP QPD calibration attempt[Jenne, Alex] 
Calibration data for the POP QPD
has been taken, with the PRMI locked on sideband
  
  8825   Thu Jul 11 03:14:19 2013 JenneUpdateLSCYarm held nicely on IR resonance with ALS, PRMI+arm attempt[Annalisa, Jenne, Nic]
After having troubles with the Xarm
earlier (maybe Manasa can write/say something
 Yarm_onIRresonance_noPRMIyet_POYcalibrated.pdf 
  8840   Fri Jul 12 21:23:42 2013 JenneUpdateASCPOP QPD calibration attemptThese are the data, one plot for when the
vertical QPD position was changed, and one
for when the horizontal (yaw) QPD position
 ChangeVertMicrometer_July2013.pngChangeSideMicrometer_July2013.png 
  8851   Mon Jul 15 17:16:59 2013 JenneUpdateASCPOP QPD calibration attemptI tried to retake POP QPD calibration data
again today.  The MC was mostly fine,
but whenever the PRMI unlocked, both ITM
 ChangeSideMicrometer_July2013_calib2.pngChangeSideMicrometer_July2013_calib1.pngChangeVertMicrometer_July2013_calib1.png 
  8852   Mon Jul 15 17:20:43 2013 JenneConfigurationendtable upgradeDAC at 1Y4- Power Spectrum -with the right unitsThose 'peaks' for the oscillations seem
ridiculously broad.  I think you should
look again, really quickly, with smaller
  
  8854   Tue Jul 16 01:17:21 2013 JenneUpdateASCPOP QPD calibration attempt[Rana, Jenne]
I took POP QPD calibration data with
a new method, on Rana's suggestion. 
  
  8860   Tue Jul 16 18:20:25 2013 JenneUpdateCDSProto-ASC implemented in ASS modelThe proto-ASC now includes triggering. 
I have updated the hacky temp ASC screen
to show the DoF triggering.  I have
  
  8871   Thu Jul 18 15:55:31 2013 JenneUpdateLSCPRMI+Y arm ALS Sensing MatricesLast
night, I took sensing matrix data at various
different offsets for the Yarm. 
 SensMatMeas_17July2013_PRMI_YarmOffResonance.pngSensMatMeas_17July2013_PRMI_YarmMidResonance.pngSensMatMeas_17July2013_PRMI_YarmOnResonance.png 
  8890   Mon Jul 22 16:56:14 2013 JenneUpdateGeneralVent preparation - In progressPre-vent checklist


   Center all oplevs/IPPOS/IPANG

   Align the arm cavities for
  
  8891   Mon Jul 22 17:03:25 2013 JenneUpdateGeneralMC spot positionsThe results of today's MC spot position
measurements:
spot positions in mm (MC1,2,3 pit
 MCdecenter_22July2013.png 
  8893   Mon Jul 22 18:49:16 2013 JenneUpdateGeneralVent preparation - In progressI have just centered IPPOS, as well as
PSL POS and PSL ANG (also called IOO POS
and IOO ANG on the screens).  Annalisa
  
  8897   Tue Jul 23 01:30:27 2013 JenneUpdateASCPOP QPD analysisI have some data for how much motion of
any PRMI-relevant optic affects the beam
seen by the POP QPD. 
 9x 
  8902   Tue Jul 23 04:26:54 2013 JenneUpdateGeneralMC spot positionsAfter Koji and I lowered the power into
the PMC and saw that the MC locked nicely,
I remeasured the spot positions (no alignment
 MCdecenter_22July2013_lowpower.png 
  8903   Tue Jul 23 04:31:36 2013 JenneUpdateGeneralVent preparation - Ready for VentAfter
everyone's work today (good teamwork everybody!!),
  
  8914   Tue Jul 23 22:55:13 2013 JenneUpdateVACBS, ITMY doors to be opened in the morningWe will open the BS and ITMY doors first
thing tomorrow morning. I plan to try to
be in around 9 am.  The first order of business
  
  8916   Wed Jul 24 13:41:13 2013 JenneUpdateSUSSR2 flipped[Jenne, Annalisa]
SR2 is flipped, and reinstalled. 
We did that before lunch, and we're about
  
  8924   Thu Jul 25 14:02:53 2013 JenneUpdateSUSSR3, PR3 flippedYesterday afternoon, I went back into the
BS chamber, and flipped both PR3 and SR3.
  
  8960   Fri Aug 2 17:50:10 2013 JenneUpdateGeneralPR3 wedge angle adjusted[Jenne, Manasa, Koji]
Earlier today, we locked and aligned
both the X and Y arms. 
  
  8962   Fri Aug 2 22:51:10 2013 JenneUpdateGeneralAll vent tasks complete, just need oplev check[Manasa, Koji, Jenne]
We went into the BS and IOO chambers,
and aligned the green beams such that they
  
  8974   Tue Aug 6 19:53:15 2013 JenneUpdateLSCArms locked in IR, aligned. IFO at nominal power[Koji, Manasa, Jenne]
The Y arm was locked in IR, and we
saw flashing in the Xarm (Gautam had the
  
  8980   Wed Aug 7 19:16:20 2013 JenneUpdateASCASS setting up accelerated moreI have furthered Koji's work, and moved
the filter on/off state for all the filter
banks also to the burt snapshot.  
  
  8981   Wed Aug 7 21:52:11 2013 JenneUpdateSUSSRM coils fine - problem with slow bias slider[Koji, Jenne]
We have looked a little more at the
SRM situation.  We aligned the SRM,
  
  8995   Mon Aug 12 12:57:59 2013 JenneUpdateCDSX-End Green ASS - Roundup

    

       
            
  
  8997   Mon Aug 12 14:05:34 2013 JenneUpdateASCPRCL ASS software in place

    

       
            
  
  8998   Mon Aug 12 15:39:40 2013 JenneUpdateASCPRCL ASS screens in placeI have added the PRCL ASS to the main ASS
screen, and created the servo and lockin
screens.  The filters loaded are the
  
  9001   Mon Aug 12 23:13:14 2013 JenneUpdateASCPRCL ASS software in place

    

       
            
  
  9030   Mon Aug 19 11:30:20 2013 JenneUpdateIOOMC mirrors' ASC has non-zero inputs[Masayuki, Jenne]
When I came in this morning, I noticed
that the Mode Cleaner had not been locked
  
  9036   Mon Aug 19 23:08:31 2013 JenneUpdateLSCDRMI sensing signalsHere are a bunch of sensing signals. 
The configuration is always DRMI.  Except
for the optic noted in the title and the
 11x 
  9038   Tue Aug 20 01:28:47 2013 JenneUpdateLSCREFL investigationsAccording to the wiki, REFL 11 has a transimpedance
of 4.08kV/A, and REFL 55 has a transimpedance
of 615V/A.  This is a ratio of ~6.5
  
  9041   Tue Aug 20 11:52:20 2013 JenneUpdateLSCREFL investigations

    

       
            
  
  9043   Tue Aug 20 18:42:57 2013 JenneUpdateLSCREFL investigationsI have done the swap in the REFL path. 
First, I swapped the positions of REFL11
and REFL55.  Then, I swapped out the
  
  9049   Thu Aug 22 02:40:12 2013 JenneUpdateLSCDRMI Locked for 1+ minute!!!!!![Jenne, Koji]
The DRMI
 DRMI_First_Lock_1plusMinute_21Aug2013.png 
  9052   Thu Aug 22 13:03:40 2013 JenneUpdateLSCDRMI Locked for 1+ minute!!!!!!

    

       
            
  
  9057   Fri Aug 23 01:52:34 2013 JenneUpdateSUSViolin filters moved to LSC, from SUS[Rana, Jenne]  MICHloopNotches_23Aug2013.pdf 
  9062   Mon Aug 26 18:55:18 2013 JenneConfigurationElectronicsputting together a 110 MHz LSC demod board for ASI have modified one of the spare demod
boards that was sitting above the electronics
bench (the one which was unlabeled - the
 AS110_demod_board_modifications.pdf 
  9068   Tue Aug 27 02:18:28 2013 JenneUpdateLSCPRMI, DRMI sensing matricesI have made a measurement of the PRMI and
the DRMI sensing matrices. 
Keiko pointed out to me in an email
 SensMatMeas_26Aug2013_withErrorBars.pngSensMatMeas_26Aug2013_DRMI_firstEverMeasurement.png 
  9069   Tue Aug 27 15:31:48 2013 JenneConfigurationElectronicsputting together a 110 MHz LSC demod board for AS

    

       
            
  
  9071   Tue Aug 27 17:32:52 2013 JenneConfigurationElectronicsputting together a 110 MHz LSC demod board for ASI measured the phase split between the
I and Q signals of my AS110 board. 
To do so, I plugged the board into an empty
  
ELOG V3.1.3-