40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 68 of 335  Not logged in ELOG logo
Entry  Mon Mar 8 12:01:02 2021, Paco, Anchal, Summary, training, Investigate how-to XARM locking 
    Reply  Mon Mar 8 12:40:35 2021, gautam, Summary, training, Investigate how-to XARM locking 
    Reply  Mon Mar 8 19:22:56 2021, rana, Summary, SUS, IMC suspension characterization 
Entry  Tue Mar 9 10:57:06 2021, Paco, Anchal, Summary, IMC, XARM lock and POX spectra 20210309_POX11_Spec_XARMLocked.pdf20210309_XARM_Locked.tar.gz
Entry  Tue Mar 9 12:41:29 2021, Koji, Summary, Electronics, Investigation on the invacuum Dsub cables SOS_OSEM_cabling.pdf
    Reply  Tue Mar 9 14:37:26 2021, gautam, Summary, SUS, PRM suspension PRMtrip.png
    Reply  Tue Mar 9 15:22:56 2021, Koji, Summary, SUS, PRM suspension 
Entry  Wed Mar 10 11:46:22 2021, Paco, Anchal, Summary, IMC, IMC free swinging prep 
    Reply  Wed Mar 10 15:00:16 2021, gautam, Summary, IMC, IMC free swinging prep 
    Reply  Wed Mar 10 15:29:58 2021, Anchal, Summary, IMC, IMC free swinging prep 
    Reply  Wed Mar 10 15:35:25 2021, Paco, Anchal, Summary, IMC, IMC free swinging experiment set to trigger at 5:00 am freeSwingMC.py.zip
Entry  Thu Mar 11 02:10:06 2021, Koji, Summary, BHD, BHD Platform vertical dimentions BHD_Platform_Vertical_Dimentions.pdf
Entry  Fri Mar 12 03:08:23 2021, Koji, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM P_20210311_224651.jpgP_20210311_225359.jpg
    Reply  Fri Mar 12 12:32:54 2021, gautam, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM BS_actuator.pdfPRMact.pdf
    Reply  Fri Mar 12 13:01:43 2021, rana, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM 
    Reply  Fri Mar 12 13:48:53 2021, gautam, Summary, SUS, Coil Rs & Ls for PRM/BS/SRM 
Entry  Fri Mar 12 18:10:01 2021, Anchal, Summary, Computer Scripts / Programs, Installed cds-workstation on allegra 
Entry  Mon Mar 15 08:55:45 2021, Paco, Anchal, Summary, training,  IMC_InputMatrixDiagonalization.pdfinputMatrixCalculationMC.tarfreeSwingMC.py.tarSUSfreeswing_1299514263.txt.tar
Entry  Sun Mar 21 19:31:29 2021, rana, Summary, Electronics, RTL-SDR for monitoring RF noise / interference Screen_Shot_2021-03-21_at_7.43.24_PM.png
    Reply  Thu Mar 25 16:02:15 2021, gautam, Summary, SUS, Repeated measurement of coil Rs & Ls for PRM/BS 
    Reply  Sun Mar 28 14:16:25 2021, Anchal, Summary, SUS, MC3 new Input Matrix not providing stable loop MC3_Input_Matrix_Diagonalization.pdf
    Reply  Mon Mar 29 17:07:17 2021, gautam, Summary, SUS, MC3 new Input Matrix not providing stable loop 
    Reply  Wed Mar 31 03:56:37 2021, Koji, Summary, Electronics, A bunch of electronics received P_20210331_013257.jpgP_20210331_014020.jpg
    Reply  Thu Apr 1 23:55:33 2021, Koji, Summary, General, HEPA AC cord replacement 
    Reply  Fri Apr 2 15:17:23 2021, gautam, Summary, General, HEPA AC cord replacement 
    Reply  Tue Apr 6 21:17:04 2021, Koji, Summary, General, PSL HEPA investigation 20210406211741_IMG_0554.jpeg20210406211840_IMG_0555.jpeg20210406211850_IMG_0556.jpeg
Entry  Mon Apr 12 08:32:54 2021, Anchal, Paco, Summary, PSL, PMC unlocked at 2pm on Sunday; ~ Restored 
    Reply  Mon Apr 12 18:34:26 2021, Yehonathan, Summary, PSL, PMC unlocked at 2pm on Sunday; ~ Restored 
Entry  Wed Apr 21 10:59:07 2021, rana, Summary, Cameras, note on new GigE cam @ 1064 
Entry  Thu Apr 22 01:42:38 2021, Koji, Summary, Electronics, HV Supply Comparison HV_Supply_PSD_H.pdfHV_Supply_PSD_K.pdfHV_Supply_PSD_M.pdfHV_Supply_PSD.pdf
Entry  Thu Apr 29 11:51:27 2021, Anchal, Summary, LSC, Start of measuring IMC WFS noise contribution in ar cavity length noise 
    Reply  Thu Apr 29 17:51:19 2021, Anchal, Summary, LSC, Start of measuring IMC WFS noise contribution in arm cavity length noise WFS1_PIT_exc_80-100Hz_Arms_ASD.pdf
    Reply  Fri Apr 30 00:18:40 2021, gautam, Summary, LSC, Start of measuring IMC WFS noise contribution in arm cavity length noise 
Entry  Mon May 3 18:59:58 2021, Anchal, Summary, General, Weird gas leakagr kind of noise in 40m control room 40mNoiseFinal.mp3
    Reply  Mon May 3 23:28:56 2021, Koji, Summary, General, Weird gas leakagr kind of noise in 40m control room 
Entry  Thu May 6 16:13:39 2021, Anchal, Summary, IMC, Angular actuation calibration for IMC mirrors IMC_Ang_Act_Cal_Kakeru_Tests.pdf
Entry  Mon May 10 10:57:54 2021, Anchal, Paco, Summary, Calibration, Using ALS beatnote for calibration, test BeatY_ITMY_CalibrationAt57Hz.pdfBeatY_ITMY_CalibrationAt43Hz.pdfBeatY_ITMY_CalibrationAt77Hz.pdf
    Reply  Wed May 12 11:45:13 2021, Anchal, Paco, Summary, SUS, New IMC Settings are miserable MC_F_Comparison.pdfMC_TRANS_QPD_Comparison.pdfIMC_REFL_DC_Comparison.pdf
    Reply  Mon May 24 19:14:15 2021, Anchal, Paco, Summary, SUS, MC1 Free Swing Test set to trigger 
Entry  Mon May 24 20:55:00 2021, Koji, Summary, BHD, How to align two OMCs on the BHD platform? 
    Reply  Tue May 25 10:22:16 2021, Anchal, Paco, Summary, SUS, MC1 new input matrix calculated and uploaded SUS_Input_Matrix_Diagonalization.pdf
Entry  Tue May 25 17:42:11 2021, Anchal, Paco, Summary, ALS, ALS Single Arm Noise Budget ALS_IR_b.svgALS_Single_Arm_IR.pdf
    Reply  Thu May 27 11:03:15 2021, Anchal, Paco, Summary, ALS, ALS Single Arm Noise Budget ALS_Single_X_Arm_IR.pdfALS_OOL_with_Ref.pdf
    Reply  Fri May 28 17:32:48 2021, Anchal, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat SingleArmActCalwithIRALSBeat.pdfstateSpaceModel.zip
    Reply  Tue Jun 1 16:55:32 2021, Anchal, Paco, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat SingleArmActCalwithIRALSBeat-1306624785.pdf
    Reply  Wed Jun 2 09:43:30 2021, Anchal, Paco, Summary, SUS, IMC Settings characterization seismicX.pdfseismicXtoMC_F_TFest.pdfseismicXtoMC_TRANS_PIT_TFest.pdfseismicXtoMC_TRANS_YAW_TFest.pdf
    Reply  Wed Jun 2 16:20:59 2021, Anchal, Paco, Summary, SUS, IMC Suspension gains reverted to old values 
    Reply  Thu Jun 3 17:35:31 2021, Anchal, Summary, IMC, Fixed medm button C1IOO_Mech_Shutters.png
Entry  Mon Jun 7 15:37:01 2021, Anchal, Paco, Yehonathan, Summary, Cameras, Mon 7 in Control Room Died 
    Reply  Tue Jun 8 11:40:53 2021, Anchal, Paco, Summary, ALS, Single Arm Actuation Calibration with IR ALS Beat ITMX_Cal_Noise_Spectrum_1307143423.pdf
ELOG V3.1.3-