  8498   Fri Apr 26 20:43:51 2013 JenneUpdateLSCRemeasuring the Schnupp asymmetry[Jenne, Annalisa, with guidance from Koji]
We took data to remeasure the
Schnupp asymmetry, using the Valera method
  
  8499   Fri Apr 26 21:38:06 2013 JenneConfigurationRF SystemPD frequency responseI was sad to see that there wasn't a photo
of the POX situation after the fiber work
was done on Thursday.
 IMG_0498.JPGIMG_0499.JPGIMG_0500.JPG 
  8507   Mon Apr 29 18:53:03 2013 JenneUpdateElectronics1pps timing fiber to OMC rack may be bentWhile helping Riju out this afternoon,
I noticed that the timing fiber that goes
to the OMC rack (near the AP table) was bent,
  
  8510   Tue Apr 30 10:54:35 2013 JenneUpdateSUSETMX restoredI'm not sure why or when it was tripped,
but I have restored the ETMX watchdog.
  
  8513   Tue Apr 30 21:24:15 2013 JenneConfigurationRF SystemPOX fiber layingNice work.  That was a lot of effort,
but having done it so nicely will definitely
pay off, since it is now much harder to break
  
  8514   Tue Apr 30 22:40:57 2013 JenneUpdateSUSoplev XY-plots reflect new calibrationBack when Gabriele was here, he and I implemented
online calibration of the oplevs, into microradians. 
A consequence of this is that all of the
  
  8515   Tue Apr 30 23:04:23 2013 JenneConfigurationRF SystemOnly 4 25m cables orderedI have found in the depths of the elog
the (original?) list of fibers and lengths
that were decided upon:  elog
  
  8516   Tue Apr 30 23:17:25 2013 JenneUpdateLSCPRCL LSC filters copied to CARM bank temporarilyKoji is working on PRMI locking with different
photodiodes, and rather than typing different
numbers into the input matrix, it is more
  
  8519   Wed May 1 14:42:45 2013 JenneUpdateLSCPOP now has lens in front of PD

    

       
            
  
  8528   Fri May 3 17:32:59 2013 JenneUpdateLSCRemeasuring the Schnupp asymmetryI have looked at / analyzed the Schnupp
data that Annalisa and I took last week,
as well as some more Yarm data that I took
 Xarm_SchnuppData_April2013.pngYarm_SchnuppData_April2013.png 
  8532   Tue May 7 03:08:12 2013 JenneUpdate PRM yaw responsible for RINKoji spent some time earlier this evening
exploring where the excess RIN that we see
in the PRC is coming from. 
 BS_excited.pdfITMX_excited.pdfITMY_excited.pdfPRM_excited.pdf 
  8533   Tue May 7 03:14:06 2013 JenneUpdateSUSPRM SUS_LSC violin (FM5) set to correct frequencyWhile looking over Koji's shoulder earlier,
I noticed the big peak in the PRM yaw spectrum
(and I was starting to get annoyed by the
  
  8534   Tue May 7 03:25:28 2013 JenneUpdateIOOMC WFS drifting??I'm not sure why, but starting ~3.5 hours
ago, the WFS seem to not be holding the MC
in optimal alignment. 
  
  8537   Tue May 7 16:21:01 2013 JenneSummaryLSCError signal simulation in PRMII asked Gabriele why it looked like for
the PRCL sweep REFL 55 I&Q were zero
at zero, but for the MICH sweep only REFL55
 8x 
  8538   Tue May 7 17:13:30 2013 JenneUpdateRF SystemIdeal PRMI RF frequencyKoji asked me to look at what the ideal
RF modulation frequency is, for just the
PRMI case (no arms).  If we had a perfect
  
  8557   Thu May 9 02:19:53 2013 JenneUpdateLocking50% BS installed in POP pathKoji had the good idea of trying to measure
the motion of the POP beam, and feeding that
signal to PRM yaw to stabilize the motion. 
  
  8558   Thu May 9 02:47:23 2013 JenneUpdatePEMT240 at corner station - cabling thoughtsSomething that I want to look at is the
coherence between seismic motion and PRM
motion.  Since Den has been working
  
  8559   Thu May 9 15:07:51 2013 JenneUpdateGeneralDistances from CAD drawingSince I keep asking Manasa to "measure"
distances off of the CAD drawing for me,
I thought I might just write them all down,
 05091301.PDF 
  8563   Mon May 13 17:24:38 2013 JenneUpdateWienerFilteringPRM YAW Wiener filteringI have done a quicky offline Wiener filter
to check how much PRM yaw motion we can subtract
using a seismometer in the corner station. 
 PRM_SUSYAW_subtractUsing_GUR1_xyz.png 
  8564   Mon May 13 18:44:04 2013 JenneUpdateLockingprcl angular motionI want to redo this estimate of where RIN
comes from, since Den did this measurement
before I put the lens in front of the POP
 TT_Q_measurements.pdf 
  8567   Mon May 13 23:05:51 2013 JenneUpdatePEMGUR1 masses recentered[Evan, Jenne]
Evan brought the Guralp handheld
readout paddle and cables back from the ATF
  
  8568   Tue May 14 01:13:35 2013 JenneUpdate40m UpgradingTRY realignedKoji noticed that earlier this afternoon
the Yarm ASS was working, but then after
dinner it was no longer working.  I
  
  8569   Tue May 14 01:56:20 2013 JenneUpdateGreen LockingXend Green tweakedI locked the Xarm on green.  At the
PSL table, I adjusted the steering mirror
to get the beam centered on the GTRX DC PD. 
  
  8587   Thu May 16 01:41:31 2013 JenneSummaryIOOFSS gain settings set

    

       
            
  
  8589   Thu May 16 04:46:37 2013 JenneUpdateLSCKiwamu's sensing matrix measurement script revivedKiwamu had an old set of scripts for
measuring
the sensing matrices, but they were
  
  8593   Thu May 16 23:48:39 2013 JenneUpdateLSCKiwamu's sensing matrix measurement script revivedKoji locked the PRMI for me, and I took
some data.  I haven't finished figuring
out what to do with it / writing a processing
  
  8600   Mon May 20 17:49:36 2013 JenneUpdateLSCPRMI sensing matrix - not high quality dataJust so we have some numbers, I did a by-hand
analysis of the PRMI sensing matrix numbers
I posted here in the elog the other day. 
 PRMIsensMatQuickAnalysis.m.gz 
  8602   Mon May 20 18:50:22 2013 JenneUpdateLSCKiwamu's sensing matrix measurement script revivedSo that I don't have to do loop compensation
every time I measure a sensing matrix, I
have put (back) in notches into FM10 of all
  
  8603   Tue May 21 14:48:08 2013 JenneUpdateLSCPRMI sensing matrix - not high quality dataThe PRMI sensing matrix, as measured last
Thursday, in a more readable format:
EDIT: DON'T Look at this
  
  8609   Tue May 21 18:22:18 2013 JenneUpdateLSCSensing matrix scripts modified to include actuator calibrationThe PRMI sensing matrix scripts have been
modified to output a sensing matrix which
is calibrated into units of counts/meter.
  
  8618   Wed May 22 17:29:34 2013 JenneUpdateASCQPD for POP ASC testedI fiddled around with the QPD that I'll
use to replace Koji's temporary razor blade
yaw sensor for detecting POP beam angular
  
  8619   Wed May 22 18:07:36 2013 JenneUpdateLSCKiwamu's sensing matrix measurement script revived 
 To avoid exciting at the PRM
violin mode frequency, I have changed all
  
  8620   Wed May 22 18:24:19 2013 JenneUpdateSUSViolin mode survey

    

       
            
  
  8621   Wed May 22 20:50:26 2013 JenneUpdateLSCSensing matrix scripts don't calculate correctlyI am trying to re-analyze the data that
Koji took last night.  
I think that my script is just pulling
  
  8623   Thu May 23 00:49:13 2013 JenneUpdateLSCLSC filters loaded

    

       
            
  
  8630   Thu May 23 14:45:08 2013 JenneUpdateLSCSensing matrix scripts calculations make more sense nowI think I have most of the magnitude issues
figured out now. 
First of all, the lockin outputs
 SensMat_JenneMeas_23May2013.pngSensMat_KojiMeas_23May2013.png 
  8632   Thu May 23 19:09:15 2013 JenneUpdateLSCSensing matrix scripts modified to include actuator calibrationAfter fixing up my calculations in my scripts,
I have calculated the final PRMI sensing
matrix (as measured very close to the violin
 SensMat_21May2013.png 
  8633   Thu May 23 20:39:50 2013 JenneUpdateLSCPRMI sensing matrix measured at 580.1HzI locked the PRMI and remeasured the sensing
matrix, this time at 580Hz.  The excellent
news here is that the matrix looks quite
 SensMat_23May2013.png 
  8634   Thu May 23 20:58:49 2013 JenneUpdatePEMPRM, ITMX optics tripped, restored
M5.7
- 11km WNW of Greenville, California
Time2013-05-23
  
  8635   Thu May 23 21:45:51 2013 JenneUpdateLSCSensing matrix scripts now check for locklossA few more small mods to the sensing matrix
script.  Now the script saves the data
after each measurement, so that in case you
  
  8640   Fri May 24 13:41:19 2013 JenneUpdateLSCPRMI sensing matrix measured at 580.1Hz"0 degrees" is 0 degrees of demod
phase.  I have now added the PD demod
phases to the plot:
 SensMat_23May2013_withIQ.png 
  8642   Fri May 24 14:40:22 2013 JenneUpdateLSCPRMI sensing matrix: now what?

    

       
            
  
  8643   Fri May 24 14:44:34 2013 JenneUpdateGeneralRossa freezes all the timeI am getting tired of having to restart
Rossa all the time.  She freezes almost
once per day now.  Jamie has looked
  
  8644   Fri May 24 22:18:33 2013 JenneUpdateLSCPRMI sensing matrix: Got it!Okay, I think I am finished with the sensing
matrix scripts!  
I had the syntax for atan2() wrong,
 SensMat_23May2013_withIQ_andCorrectPhases.png 
  8648   Tue May 28 14:52:56 2013 JenneUpdateLSCPRMI sensing matrix: Got it!Just so we have it, here is the re-analysis
with the correct plot and phases for the
May 21st data, taken near the violin mode:
 SensMat_21May2013_withIQ_andCorrectPhases.png 
  8649   Tue May 28 17:00:50 2013 JenneUpdateASCProposed POP path, to be installed this eveningI have mounted 2 2" G&H high reflective
mirrors, to be used in the new POP path. 
Manasa and Annalisa are doing green things
 CurrentPOPpath.pdfProposedPOPpath.pdf 
  8658   Thu May 30 17:18:58 2013 JenneUpdateASCNew POP pathI have placed the G&H mirrors and the
Y1 as pictured in my proposed layout in elog
  
  8663   Sat Jun 1 14:14:56 2013 JenneUpdateASCNew POP pathI have a lens solution for the new POP
QPD, plotted below.  To get the beam
size, I started with the waist at the ITM,
 POX_table_30May2013progress.pdfPOP_QPD_lensSolution.png 
  8697   Wed Jun 12 23:06:33 2013 JenneUpdateGreen LockingY arm locked with green but bad mode matchingHmmm.  You seem to be saying that more light
is reflected than is injected. Is this a
units problem? Or was some IR on the power
  
  8700   Thu Jun 13 15:04:16 2013 JenneUpdateLSCNew modeled sensing matrixUsing all of the latest parameters that
I can find, I have re-modeled the 40m sensing
matrix.  Also, I have it output the
 SensMatMeas_23May2013.pngSensMatModel_13June2013.png 