  8250   Thu Mar 7 12:39:12 2013 JenneUpdateLockingErudite discussion on PRMI locking[Rana, Jenne, Yuta] (late last night)
After some trouble getting the PRMI
to lock with REFL55 I&Q last night, we
  
  8253   Thu Mar 7 18:41:03 2013 JenneUpdateElectronicsPOX whitening was fine all alongHere are the transfer functions that we
took back in 2011 (see elog
4915 and replies) for POX:
 POX11I.pngPOX11Q.png 
  8258   Fri Mar 8 13:42:35 2013 JenneUpdateABSLBS installed on ITMY tableRe:  POY beam reduction.
We are able to lock the Yarm with
the beam / gain as it is.  I had thought
  
  8260   Fri Mar 8 16:02:52 2013 JenneUpdateAlignmentGetting closer to beam centering on YarmI'm working on getting the input beam centered
on the Yarm optics.  To do this, I measured
the spot positions, move the tip tilts, realign
 YARMdecenter_zoom_8Mar2013.png 
  8268   Mon Mar 11 14:10:05 2013 JenneUpdateEnvironmentMC suspensions moved by this morning's earthquakesNone of the suspensions
All suspensions were tripped (edited
by Manasa; see elog
 EQ.pngMC-SUS-kicked-EQ.png 
  8269   Mon Mar 11 15:52:46 2013 JenneUpdateIOOMC spots centered, WFS realignedLooking more into the MC, it appears that
no spot centering was done after the power
attenuation optics were removed (see elog
 MCspots_11Mar2013.png 
  8272   Mon Mar 11 19:01:21 2013 JenneUpdatePEMproposed seismometer locationsThis is my interpretation of where Steve
is proposing to place the seismometers (he
wrote ITMX southwest, but I'm pretty sure
 SeismometerProposedPositions_11March2013.pdf 
  8274   Tue Mar 12 00:35:56 2013 JenneUpdateComputersFB's RAID is beeping [Manasa, Jenne]
Manasa just went inside to recenter
the AS beam on the camera after our Yarm
  
  8275   Tue Mar 12 00:45:50 2013 JenneUpdateIOOMC weird again~20 minutes ago, maybe right around the
time the fb's RAID died (elog 8274)
the mode cleaner started behaving weirdly
  
  8277   Tue Mar 12 11:49:18 2013 JenneUpdateIOOMC weird again[Manasa, Annalisa, Jenne]
The MC wasn't locking on TEM00 this
morning, and the WFS kept pulling the MC
  
  8279   Tue Mar 12 14:02:22 2013 JenneUpdateAlignmentBeam drift - mystery partially solved?Steve just told those of us in the control
room that the custodian who goes into the
IFO room regularly steps on the blue support
  
  8281   Wed Mar 13 02:48:13 2013 JenneUpdateIOOMC all betterKoji reminded me (again....this is probably
the  2nd or 3rd time I've "discovered"
this, at least) that the script
  
  8290   Wed Mar 13 21:04:37 2013 JenneUpdateGreen LockingPSL green cleaned upBoth X and Y green are aligned such that
the arm beams hit the broadband PD. 
Also, the 4th port of the combining BS for
  
  8291   Thu Mar 14 04:20:54 2013 JenneUpdateGreen LockingYbeat attemptI dedicated my evening to trying to get
the Ygreen beatnote (the idea being to then
get the Xgreen beatnote).
  
  8293   Thu Mar 14 13:38:29 2013 JenneUpdateGreen LockingPSL green cleaned upI ran a cable to the GTRX camera. 
It is now input #2.  The videoswitch
script input naming is modified to match
  
  8294   Thu Mar 14 16:41:48 2013 JenneUpdateGreen LockingYarm ALS laser is funny / dying

    

       
            
  
  8297   Thu Mar 14 20:22:33 2013 JenneUpdateGreen LockingXbeat attemptI aligned the Xgreen and PSL green to overlap
on the X beat PD, and reconnected the splitter
which combines the X and Y beat signals and
  
  8298   Fri Mar 15 01:57:02 2013 JenneUpdateGreen LockingX arm green locked in TEM00This work earlier today had required moving
the harmonic separator back closer to its
original position, so that the green could
  
  8299   Fri Mar 15 02:14:27 2013 JenneUpdateCDSSimulink linking to wrong library partJamie and I discovered a problem with Matlab/Simulink
earlier today. 
In the end suspension models, there
  
  8300   Fri Mar 15 02:19:01 2013 JenneUpdateGreen LockingYarm ALS laser is funny / dyingI turned the laser back on around 1am. 
This is still happening, although right now
it is turning off more often than before,
  
  8302   Fri Mar 15 16:46:52 2013 JenneBureaucracyAuxiliary lockingYend table upgrade - fast track?In light of the Yend auxiliary laser's
ill health, I think we should reconsider
the possibility of changing out the Yend
  
  8304   Mon Mar 18 12:23:25 2013 JenneBureaucracyAuxiliary lockingYend table upgrade - go fetch NPRO from ATFZach has just replied, and said that we
should feel free to take
  
  8312   Tue Mar 19 19:19:50 2013 JenneUpdate40m UpgradingEndtable upgrade : INVENTORYDoes "Ready (in stock)" for the
base plates mean in stock at the company,
or in hand and already here in the
  
  8334   Mon Mar 25 09:52:22 2013 JenneUpdateComputersc1lsc mxstream won't restartMost of the front ends' mx streams weren't
running, so I did the old mxstreamrestart
on all machines (see elog
  
  8339   Mon Mar 25 16:51:59 2013 JenneUpdateOpticsupdated calculations of PRC/SRC g-factors and ARM mode matchingI think we like the idea of flipping SR2
better than SR3 for the same ghost beam reasons
as PR2 is better than PR3.  There isn't
  
  8347   Tue Mar 26 00:06:37 2013 JenneUpdateLockingAS beam put back on PD[Jenne, Gabriele]
We aligned MICH (first locked Yarm,
but didn't optimize since we don't have TRY,
  
  8348   Tue Mar 26 00:17:47 2013 JenneUpdateLockingREFL pickoff fractionTo see how much of the light that comes
out of the REFL port actually  goes to the
PDs, I measured the power immediately after
  
  8351   Tue Mar 26 11:08:03 2013 JenneUpdateLockingPRMI locking should be possible - let's get it done![Jenne, Gabriele, Jamie]
We have looked at Koji's old Finesse
code, and determined that the PRMI sensing
 PRMI_SBres_plot_allTheFs_LowRes.pngLSC_sigmatrix_PRMI.pdf 
  8360   Wed Mar 27 15:46:13 2013 JenneUpdateLockingPRMI progress[Gabriele, Jenne]
We have achieved PRMI locks of the
order ~5 seconds! Here is an example lock:
 PRMI_sb_27Mar2013.png 
  8362   Thu Mar 28 00:31:11 2013 JenneUpdateSUSPRMI optics' oplev servos tuned[Rana, Gabriele, Jenne, Jamie, Lisa, Rana]
We have tuned the oplev servos for
PRM, BS, ITMX, ITMY.  For each, we measured
 8x 
  8363   Thu Mar 28 01:59:33 2013 JenneUpdateLockingPRMI progress - even better![Gabriele, Rana, Jenne, Jamie, Lisa, Zach]
We
tweaked some things after dinner, and our
  
  8367   Thu Mar 28 12:50:52 2013 JenneUpdateComputersc1lsc is fine Manasa told me that she   
  8380   Mon Apr 1 09:25:35 2013 JenneMetaphysicsLSCLock of PRMI on sidebands[Gabriele, Jenne]
I put a notch in FM10 for both MICH
and PRCL at 628Hz, to try to prevent us from
  
  8385   Mon Apr 1 17:59:04 2013 JenneUpdateLockingPRMI videos[Gabriele's work, I'm just spectating]
Annalisa is working on finding the
PSL/AUX laser beatnote, so the PSL temp is
  
  8389   Tue Apr 2 15:58:40 2013 JenneUpdateSUSoplev calibration for ITMX, BS[Jenne, Gabriele]
Optical lever calibrations:
ITMX pit calibration = -9.07 cts/mrad
 opl_itmx.pngopl_bs.png 
  8391   Tue Apr 2 16:55:34 2013 JenneUpdateSUSoplev calibration online for ITMs, BS, PRM[Jenne, Gabriele]
We have put in a new EPICS input
into the SUS library part, just before the
 comparison_opl.pdf 
  8393   Tue Apr 2 18:19:30 2013 JenneUpdateSUSBS, PRM oplev servos improved 
[Gabriele, Jenne]
We have implemented 4Hz resonant
 PRM_servo_matches_BS.pdfprm_bs_optical_levers_comparison.pdf 
  8398   Wed Apr 3 01:32:04 2013 JenneUpdateComputersupdated EPICS database (channels selected for saving)I modified /opt/rtcds/caltech/c1/chans/daq/C0EDCU.ini
to include the C1:LSC-DegreeOfFreedom_TRIG_MON
channels.  These are the same channel
  
  8399   Wed Apr 3 03:18:23 2013 JenneUpdateLockingPRMI locked with REFL55 I&Q for more than 1 minute[Rana, Gabriele, Jenne]
We have
 PRMI_sb_80sec_2Apr2013.png 
  8405   Wed Apr 3 18:22:00 2013 JenneUpdateElectronicsPOP110 re-implementedI have re-implemented POP110.  The
cable coming from the AS110 diode is disconnected,
labeled, and sitting in the cable tray next
  
  8422   Mon Apr 8 10:19:46 2013 JenneUpdatePSLLSC left enabled 
 Note: The TRY PD isn't installed
and normalized properly yet, so the IFO OVERVIEW
  
  8432   Tue Apr 9 21:27:48 2013 JenneUpdate40m Upgrading TRY temporarily in place

    

       
            
  
  8433   Wed Apr 10 01:10:22 2013 JenneUpdateLockingConfigure screen and scripts updatedI have gone through the different individual
degrees of freedom on the IFO_CONFIGURE screen
(I haven't done anything to the full IFO
  
  8438   Thu Apr 11 02:00:21 2013 JenneUpdateLockingTRY gone???TRY
signals are all gone!  Both
the PD and the camera show no signal. 
  
  8441   Thu Apr 11 03:25:29 2013 JenneHowToSUSIdea for how to properly balance SUS actuators We have calibrated the overall actuators of
each suspension independent of the optical
levers. So, we know how much we are 
  
  8444   Thu Apr 11 11:58:21 2013 JenneUpdateComputersLSC whitening c-code readyThe big
hold-up with getting the LSC whitening
triggering ready has been a problem with
  
  8462   Thu Apr 18 19:54:11 2013 JenneUpdateLSCLSC whitening triggering workingI have implemented automatic triggered
switching of the analog whitening (and digital
dewhitening). 
 LSC_FM_Trig.pngRF_PD_block.pngLSC_triggers.pngLSC_SigCond.png 
  8467   Fri Apr 19 16:58:59 2013 JenneUpdateASCArm A2L measurement scripts 90% working againAfter Den's work with the ASS model this
week, all of the channel names were changed
(this wasn't pointed out in his elog....grrr),
  
  8473   Mon Apr 22 19:48:56 2013 JenneUpdate40m Upgrading4 pins enough?Are 4 of these spring loaded pins enough? 
I'm not sure how one pin can hold 2 lids
at each point.  It seems like we need
  
  8475   Tue Apr 23 15:00:20 2013 JenneUpdate40m Upgrading4 pins enough?

    

       
            
  
ELOG V3.1.3-