40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 60 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject
  7300   Tue Aug 28 17:59:03 2012 JenneUpdateVACVENT: GO!

I have turned of the high voltage supplies for PZT1 and PZT2.  The OMC PZT high voltage supplies were already off, since we aren't really using them currently.

I have closed the PSL shutter, but have not put in a manual extra beam dump yet.

All systems go for vent!

Steve - EricQ will be here around 8am to help with the vent.

  7313   Wed Aug 29 21:02:45 2012 JenneUpdateIOOOptics between Faraday and PRM are centered, realigned

[Jenne, Suresh, with support from Jamie and Koji]

MC spots measured, MC1, MC3 no change.

No clipping going through Faraday.

Beam hitting to the right of center of PZT1.  It was translated sideways so we are now hitting it on the center.  Knobs adjusted so we hit center of MMT1.

Beam totally obscured by Faraday on the way to MMT2.  MMT2 moved north, so that we clear the Faraday by more than a beam diameter.  MMT1 knobs adjusted to hit center of MMT2.

MMT2 knobs adjusted to hit center of PZT2.

PZT2 didn't have enough range with knobs, so we loosened it, pointed then adjusted with knobs so we're hitting center of PRM. 

We need to check spot centering on PRM with camera tomorrow.

Suresh checked that we're not clipped by IP ANG/POS pickoff mirrors, but we haven't done any alignment of IP ANG/POS.

 

Tomorrow:  Open ITMX door.  Check with Watek that we're hitting center of PRM.  Then look to see if we're hitting center of PR2.  Then, continue through the chain of optics.

  7321   Thu Aug 30 19:08:08 2012 JenneUpdateVACDogs on BS, ITM chambers checked

I tightened as many of the dog clamps on the bottom of the BS, ITMX and ITMY chambers as I could find.  I used a torque wrench at 45 ft-lbs.  Some of the bolts of the dogs were too long, and I couldn't find an extender thing to accommodate the bolt so I could reach the nut.  None of the bolts moved that I was able to reach.

Steve, we're not doing final final alignment today (we will do it tomorrow), so please go around and double-check my work by checking all of the dogs first thing in the morning.  Thanks.

  7322   Thu Aug 30 20:20:52 2012 JenneUpdateSUSWatek camera placed on SE viewport of ITMX to look at PRM

[EricQ, Jenne]

We placed the Watek camera on the SE viewport of the ITMX chamber, and focused it on the face of PRM.  We are not able to see any scattered light transmitted through the PRM, so this camera was an ineffective way to try to check spot centering on the PRM.  Jamie placed one of the new targets on the PRM cage - see his elog for details.

To get more use of the camera, we need to mount it on something, at the 5.5 inch beam height, and then cover that something with clean foil so we can place the camera on the table, in the beamline in various places.  We also need to carefully wrap the cables in foil so the don't dirty anything inside.

  7323   Thu Aug 30 20:31:35 2012 JenneUpdateIOOPZT1 and PZT2 set to center of their ranges

[Koji, Jenne]

Jamie and Koji pointed out that we need to be doing the in-vac alignment with the PZTs at the center of their ranges.  Also, we confirmed that they were set to "closed loop off", so the strain gauges were not supplying any feedback.

PZT1 was set to 0 for both pitch and yaw, since it has a very limited range of motion right now, so 0 is close enough.

For PZT2, Koji and I moved the slider in pitch and yaw, and watched the LCD output monitor on the PZT driver at the bottom of 1Y3.  We saw the value on the LCD change between slider values +4 to -6 for PZT2 yaw, so it is set to -1 as the center.  We saw the value on the LCD change between slider values -4 to +5 for PZT2 pitch, so it is set to +0.5 as the center.   Beyond these slider values (the sliders all go -10 to +10), the LCD value didn't change, either at 0, or at the maximum. 

Since PZT1 doesn't really move, this shouldn't affect any of the alignment work that Suresh and I did last night, although we should quickly confirm tomorrow. On the agenda for tomorrow is adjusting PZT2 such that we hit the center of PR2 (and hopefully that will also put us through the center of the PRM target, if the alignment was done well enough last time), so it's okay that we have only now set it to the center of its range.

  7334   Tue Sep 4 11:32:58 2012 JenneUpdateLockingFriday in-vac work

Elog re: Friday's work

Adjusted PZT2 so we're hitting the center of PR2. 

Noticed that the beam centering target is too low by a few mm, since the OSEM set screw holes that it mounts to are lower than the center line of the optic.  This meant that while we were hitting the center of PR2, the beam was half clipped by PRM's centering target.  We removed the target to confirm that the beam is really centered on PR2.

Checked the beam on PR3 - it looked fine.  There had been concern last week that PR2 was severely pitched forward, but this turns out to be an effect of the PRM centering target being too low - shoot the beam downward to go through the hole, beam continues downward to hit the bottom of PR2, so beam is falling of the bottom of PR3.  But when we actually centered the beam on PR2, things looked fine on PR3. 

Checked that the beam approximately goes through the beam splitter.  Again, the targets are too low, and these 45 deg targets' holes are smaller than the 0 deg targets, so we don't see any beam going through the target, since the beam is hitting the target higher than the hole.  The beam looked left/right like it was pretty close to the hole, but it was hard to tell since the angle is bad, and I'm not infinitely tall.  We should check again to make sure that the beam is going through properly, and we're not clipping anywhere.  I'll need help from a height-advantaged person for this.

Checked that the beam is hitting the center of the ITMY, as best we can see by using an IR card at the back of the optic.  We didn't try reaching around to put a target on the front side. 

We were debating whether it would be worth it to open ETMY this week, to check that the beam transmitted through the BS hits the center of ETMY.

We also took a quick look around the AS optics, but since that depends on BS/ITMX alignment, we weren't sure how to proceed.  We need a plan for this part.  All suspended optics were restored to their last good alignment, but we haven't tried locking MICH or anything to confirm that the alignment. 

To do list:  Check no clipping on ITMY table of beam between BS and ITMY, clipping on POY optics.  Also, oplev is clipping on cable holder thing on the table - this needs to be moved.  .....other?

  7335   Tue Sep 4 13:31:55 2012 JenneUpdateGeneralThe Plan

We need a plan for the rest of the week.  I want to be closing the heavy doors on Friday at the latest.  Please add to / comment on this list!

 

Tues

* Lock MICH to get BS, ITMs aligned well

* Check if beam is hitting center of ITMs. 

* Check for clipping around BS

     - Use Watek in-vac to look at beam at all 4 BS ports - make sure no clipping going into BS, after BS in the michelson, or the AS port

* Try to get arms to flash??

* Prepare glass beam dumps??

Wed

* IPPOS / IPANG - make sure beam gets out of chambers (this may require opening ETMY)

* Jan take photos of ETMX scattering setup

* Manasa take in-vac photos of all tables, for table layouts

* Jan / Manasa viewport transmission

* Install glass beam dumps?

* If ETMY open, install glass baffle

* ????

Thurs

* ????

* Check table levelling one last time on all tables. 

Fri

* Close all heavy doors.  (Access connector, ITMX, ITMY, BS, ETMX, ETMY? )

* Drag wipe test masses

* Start at ~10am?

Mon (if not Fri)

* Start pumping

  7338   Tue Sep 4 20:03:38 2012 JenneUpdateGeneralin-vac progress

Opened ETMY, beam was high and to the right (if you look at the face of ETMY).  Tried walking beam up, since just doing PZT2 caused clipping at the BS before we got to the correct spot on ETMY.  Moved PZT1, then PZT2, to translate beam, but we couldn't get far enough without starting to fall off of PZT2.  Put PZT1 approx. back where it was. Jamie tapped on the top of PR3 (tip tilt just before BS), and then did some compensation with PZT2 to get the beam through the BS target to the center of ETMY.

The beam is very dim at ETMY.  We ended up holding the big IR card with holes such that one of the holes was near the center of the optic, in front of the cage.  Then one person turned off all the room lights so we could see the beam, another person moved PZT2 and PR3, then lights person turned on and off the lights so we could compare beam position with hole position.  A total pain, but it ended up working better than just trying to follow the beam with a card.

We clearly need a better plan for adjusting the tip tilts in pitch, because utilizing their hysteresis is ridiculous.  Koji and Steve are thinking up a set of options, but so far it seems as though all of those options should wait for our next "big" vent.  So for now, we have just done alignment by poking the tip tilt.

Tomorrow, we want to open up the MC doors, open up ETMY, and look to see where the beam is on the optic.  I am concerned that the hysteresis will relax over a long ( >1hour ) time scale, and we'll loose our pointing.  After that, we should touch the table enough to trip the BS, PRM optics, since Koji is concerned that perhaps the tip tilt will move in an earthquake.  Jamie mentioned that he had to poke the tip tilt a pretty reasonable amount to get it to change a noticeable amount at ETMY, so we suspect that an earthquake won't be a problem, but we will check anyway.

After doing all of that, we adjusted IPANG so that the beam gets out of the vacuum envelope.  The beam must squeeze between the wall of the black beam tube and a lens for the oplev, so there is a very, very limited amount of space.  The eventual new tables will be very helpful for alleviating this, but for now we must live with it.  Even though it is pretty squishy right at the edge of the table, with the new layout we should think about giving IPANG a little more space.  Basically, if there is any Yaw motion, the beam going to the QPD will be clipped, and we may get confusing info.  We moved some of the IPANG optics that are on the end transmission table so the beam is centered on the optics while it just makes it through the space between the wall and the lens.  The spot was centered on the IPANG QPD. 

We still need to check on IPPOS, but it is always easier than IPANG.

General notes:

We discovered that the 45deg SOS beam targets are awesome, especially the ones with the irises.  The plain hole ones have very small holes relative to our beam size, so they are much more useful for the MC optics (which they were designed for).  The 45deg targets were made such that the target holes do not line up with the mounting holes.  This is good, since the mounting holes are lower than the center of the optic.  I don't think ericQ and I realized that on Friday, so it's probable that we had installed the target upside-down.  We still need to remake the 0deg targets for the next vent.

Jamie dogged down the new 'bathroom mirror' that lets us see BS and PRM on the same camera view.  He also adjusted some of the masses on the BS table to relevel the table. We need to (at some point) rename the AS_SPARE camera to something like BS_PRM, since we plugged the new camera into the AS_SPARE port on the videoswitch.

tl;dr: Input beam adjusted so we're hitting center of ETMY.  IPANG coming out of vacuum, QPD centered. Need better tip tilt in-situ adjustment capability.

  7339   Tue Sep 4 20:06:04 2012 JenneUpdateLockingMC scan input switched to the 11MHz port of EOM

Since the EOM's signal combiner (splitter backwards) is frequency-independent, Koji and Jamie (in the proper turn off, turn on order) put the 55MHz signal back to the EOM, and put the MC mode scan input to the 11MHz port.  This way we can lock the Michelson tomorrow, and we don't have to keep switching cables around when Riju wants to take some scans.

  7340   Tue Sep 4 20:13:46 2012 JenneUpdateGeneralThe Plan - Tues evening version

 Tues

* Hit center of ETMY, using input optics, PR3.

* Get IPANG out of vac, center QPD.

Wed

* AM: Riju do MC mode scans

* Starting right after 40m meeting, if not before: Lock MICH to get BS, ITMs aligned well

* Check if beam is hitting center of ITMX.

* Check for clipping around BS

     - Use Watek to look at beam at all 4 BS ports - make sure no clipping going into BS, after BS in the michelson, or the AS port

       - Use some old in-vac mirrors to direct beam out the BS door.  Cameras are waiting near BS chamber.

* Prepare glass beam dumps??

* IPPOS - make sure beam gets out of chamber

* Jan take photos of ETMX scattering setup

* Manasa take in-vac photos of all tables, for table layouts

* Jan / Manasa viewport transmission

* Install glass beam dumps?

* Install glass baffle at ETMY. Jan maybe install baffle at one of ITMs.

* ????

Thurs

* ????

* Check table levelling one last time on all tables. 

Fri

* Close all heavy doors.  (Access connector, ITMX, ITMY, BS, ETMX, ETMY? )

* Drag wipe test masses

* Start at ~10am?

Mon (if not Fri)

* Start pumping

  7346   Wed Sep 5 19:29:45 2012 JenneUpdateGeneralYarm aligned to IR incident beam

[EricQ, Jenne, brains of other people]

Checked at ETMY that the pointing hadn't changed a whole lot.  Jamie and Koji pointed out that we were half falling off of the IPANG QPD.  Adjusted PZT2 sliders so that we were again centered on IPANG's QPD.  Before we close up, we'll want to put the sliders back to their nominal positions, and use the knobs to hit IPANG, but this is equivalent and fine for now.  The tip tilts don't seem to have moved much overnight, since the beam drift on both IPANG and ETMY was fixed simultaneously with PZT2 (recall, IPANG picked off before tip tilts exist in the beam path).  This left us hitting the center of ETMY.  We moved ETMY sliders to make the reflected beam hit the center of ITMY (same spot position as transmitted beam from BS).  Then moved ITMY to get prompt reflection to hit same spot on ETMY as original primary beam from BS.  Checked at ITMY that we didn't need to move ETMY anymore.  (Actually, I forget how many iterations we did, but in the end, all of the reflections that we can find are co-located on the test masses.)

Next up:

Align BS so we're hitting the center of ETMX

Tap / readjust ITMX OSEM which is at 0.3 to get it back to the center of its range

Align ITMX to lock MICH

Check no clipping on POX / POY optics, no clipping around BS

Check PRM, SRM alignment (what exactly do we want to do here? Try to lock PRMI / SRMI?)

Get IPPOS out of vac

Fix clipped ITMY / SRM oplev

Install 'black' glass beam dumps - forward-going POP beam, 2 places in BS chamber (check old elog from Jenne/Yuta for the places).

Get green spots co-located with IR spots on ETMs, ITMs, check path of leakage through the arms, make sure both greens get out to PSL table

  7348   Thu Sep 6 10:57:27 2012 JenneUpdateGeneralForgot to turn green refl pd back on

Quote:

I couldn't understand the Y-End green setup as the PD was turned off and the sign of the servo was flipped. Once they are fixed, I could lock the cavity with the green beams.

Quote:

[EricQ, Jenne, brains of other people]

Get green spots co-located with IR spots on ETMs, ITMs, check path of leakage through the arms, make sure both greens get out to PSL table

 

 I had turned the green refl PD off on Tuesday while we were doing the IPANG alignment, since the beam was not so bright, and the LED on top of the PD was very annoyingly bright.  I forgot to turn it back on.  The sign flip on the servo, I can't explain.

  7349   Thu Sep 6 13:07:02 2012 JenneUpdateIOOIPANG no longer a reference :(

I was having trouble centering IPANG using the PZTs, and I suspected something funny was going on at the end.  I went down there, and the beam was focused right on the PD, and the spot was very very small.  I think this means that when I was trying to center the beam, I was falling into the gap between the pieces of the diode.  Also, as Koji pointed out to me the other day, if the PD is at the focal point of the beam, any parallel rays hitting the lens just before the PD will all go to the same place, no matter how the input beam has moved.  This means we're not getting as much info out as we'd like.

So.  I moved the lens a little bit farther from the PD such that we are just beyond the focal point of the beam.  The beam size is now ~1mm on the QPD.

This means, however, that I moved the beam on the QPD such that IPANG is no longer a reference of the input pointing. Ooops. I think this adjustment needed to be done though.  Right now, the PZTs are set to where we had them yesterday, when we moved them slightly to center the IPANG QPD, and I've recentered IPANG.

  7350   Thu Sep 6 16:46:44 2012 JenneUpdateSUSBS aligned, target removed

Q and I aligned the BS such that we were hitting the center of ETMX. The ETMX cage does not have OSEM setscrew holes on the front, so it is not possible to put the targets that Steve made on this optic.  So, I put the freestanding ruler in front of the optic, with the edge of the ruler at the center (as viewed from above) of the optic.  Then Eric steered the BS until we were hitting the 5.5" mark, and roughly half of the beam was obscured by the ruler.

We then aligned ITMX such that the prompt reflection was colinear with the incoming beam. 

I checked the 2 spots through the BS, heading to the AS port.  (2 spots since MICH hasn't been locked / finely aligned yet).  They were being clipped on the 2nd output PZT.  I adjusted the knobs of the first output PZT to center the spots on the 2nd PZT.  Note that the output PZTs' power is still off, and has been off for some unknown length of time.  I had found them off when prepping for the vent a week or two ago.  So the current alignment depends on them staying off.  We don't really need them on until we're ready to employ our OMC.

The beams now look nicely unclipped on the AS camera, and we're aligning MICH.

  7353   Thu Sep 6 18:49:30 2012 JenneUpdateRF SystemAS 55 may be broken

I was going to lock MICH, but I don't see anything on dataviewer for either AS55Q or ASDC.  I went out onto the table, and there is beam on the diode, but no mV out on a voltmeter connected to the DC monitor point.  I shine a flashlight, and still I see 0.0mV.  So, something is up with AS55, but since the michelson is aligned right now, I'm not going to mess with the PD.  I won't lock MICH, I'll just move on.  Koji is taking a look at the diode, but if he doesn't get it figured out tonight, we can take a closer look after we pump down.

  7355   Thu Sep 6 19:36:19 2012 JenneUpdateRF SystemAS 55 is fine

Quote:

I was going to lock MICH, but I don't see anything on dataviewer for either AS55Q or ASDC.  I went out onto the table, and there is beam on the diode, but no mV out on a voltmeter connected to the DC monitor point.  I shine a flashlight, and still I see 0.0mV.  So, something is up with AS55, but since the michelson is aligned right now, I'm not going to mess with the PD.  I won't lock MICH, I'll just move on.  Koji is taking a look at the diode, but if he doesn't get it figured out tonight, we can take a closer look after we pump down.

 Never mind.  I was using an LED flashlight, which doesn't emit light that the PD is sensitive to.  A regular flashlight gives plenty of signal on the DC out. 

Using an SR560 with 30Hz low pass and gain of 100, it was pretty easy to align the light on the PD. 

Koji calculates in his head that there is about 6 microwatts of light incident on the PD, which is not a lot of light. Our SNR may be kind of lame for locking right now.

  7357   Fri Sep 7 01:25:53 2012 JenneUpdateGeneralPRC, SRC flashing

[Koji, Jenne]

* Found that IPANG was no longer centered, so we used PZT2's sliders to get the spot back on the center of the QPD.  Koji points out that I should have moved the lens even farther away, to have a larger beam (many mm, not just ~1) on the QPD.

* Found that MICH alignment had drifted, so used ITMX to realign MICH.

* Aligned PRM, got REFL beam through viewport.  Just made sure reflected beam was colinear with incident beam.

* PRC flashes were visible on AS camera. 

* PRM was more precisely aligned to have good interference with ITM reflections, by looking at AS camera.

* Decided to align SRM.  Spot was ~5mm too far to the north on the SRM....so we were off from center by ~5mm.

* Moved SR2 yaw a little bit to get spot centered on SRM.

*  Couldn't align SRM within bias slider range, so moved SRM in yaw to get reflected beam colinear with incident beam.

* Centered the spot on the steering mirrors.  The 2nd steering mirror after the SRM was moved by ~1 inch.  All mirrors after that were aligned to match this new beam.

* Found spot on AS table, aligned AS table mirrors so that beam hits AS55 PD window.  Haven't actually centered beam on PD.

* Transmission of 99% reflector was too weak to use with a card to get the beam back on the AS camera, so we moved the camera over to the AS110 path.

* Precisely aligned PRM and SRM by watching AS camera.

* Both the PRC and SRC look kind of funny.  Koji agrees.  Seriously.  They're a little weird. We can't align either recycling cavity, one ITM at a time (so PRM with ITMX, PRM with ITMY, SRM with either single ITM) to get rid of all the fringes.  Something is definitely funny.  It's got to be in the recycling cavities, since the weirdness is common between both ITMs for a given recycling mirror.  We need to take Sensoray views of these tomorrow.=

* There is some clipping on the right side of the AS camera view.  We have determined that it is not clipping at the viewport exiting the vacuum, but we aren't sure where it is.  It is at least before PZT4 (the 2nd PZT in the output AS path). 

  7365   Fri Sep 7 17:34:53 2012 JenneUpdateComputersSensoray Video Capture

Quote:

To capture video with the Sensoray, open the GUI (python ./demo.py), simply press "Save," enter a filename, and hit "Stop" when you wish to stop recording. If you want to change the video format, there is a dropdown menu labelled "Format." I recommend MP4 for standard video, and nv12 for RAW video.

 I also installed mplayer on rossa, so we can play the videos there.

Even though Mike won't admit it, the video stuff is all in /users/sensoray/ .  I opened the demo.py from there, and it also works.

  7366   Fri Sep 7 17:37:16 2012 JenneUpdate cavitymode scan

Quote:

 IMC transmission photodiode has been aligned.

 Which PD?  The 'regular' DC one, or the newer one?  Why did it need realigning?  What mirrors did you touch to do the alignment?

Did you do anything else in the last 3 days?  I want to see ALL the gory details, because it can help people doing future measurements, or help us debug if something is wrong with the interferometer later.

MORE WORDS! Thanks.

  7367   Sat Sep 8 00:04:53 2012 JenneUpdateGeneralBeam scan measurement plan - to do Monday morning.

[MikeJ, Jenne]

We have a plan for how we're going to measure the beam after PR3.  Mike is going to write up a nifty program that will spit out the waist of the beam if you give it a bunch of razor blade measurement data.

Since the beam bounced off of the pitched ITMX is coming out of the chamber so high, it's kind of a pain to setup optics to steer the beam down the walkway next to the Yarm.  So, I have a new vision.

I think that we can get the beam right after PR3 onto the PRM/BS oplev table using 3 clean mirrors (of which we have many spares, already clean).  Once on the oplev table, we can put a 2" Y1 mirror to steer the beam down the walkway, after taking off the short east side of the table.  Then we can use the little breadboard on the mobile blue pedestal for the razor blade / power meter setup.

The razor blade on a micrometer translation stage will be the first thing on that table that the beam sees. Then, a 2" lens to get the beam small enough to fit on the power meter.  Then, obviously, the power meter.  We can measure the distance between the oplev table and the razor blade using the laser range finder, which has pretty good accuracy (it's sub-centimeter, but I don't remember the exact number for the precision).

A lens is not okay if we're trying to get the beam directly onto the beam scanner, since it will distort the beam.  However, as long as the razor blade is before the lens, and we're just using the lens to get the full intensity of the non-obscured part of the beam onto the power meter, I think using a lens should be fine.  If we don't / can't use a lens, we're going to run into the same problem we have with the beam scanner, since the power meters all have a fairly small aperture.  Even the big 30W power meter's aperture will be on the order of the size of the beam, so we won't be able to guarantee non-clippage.

The main problem I see with the technique as I have described it, is that the beam is going to hit 4 mirrors (3 in-vac, one outside) before going to the razor/lens/power meter.  We have to make sure that we're not clipping on any of those mirrors.  Also, this measurement version takes the beam after PRM, PR2 and PR3, but not after the BS and ITM.  I don't think we're concerned with either of those 2 optics, (especially since this is refl off the front of the BS, so won't see any potential clipping on the BS cage), but just in case we are, this measurement isn't so useful, and we'd have to come up with a different way of placing the mirrors on the in-vac tables to get a beam bounced off  of  a yaw-ed ITMX. 

Perhaps it would be easier to just go with the pitched ITMX version of the measurement, but I could use some ideas / advice on how to mount mirrors and lenses ~4 feet off the ground outside of the chambers, and not have them waving around on skinny sticks.

 

EDIT: Another idea is to instead use the beam transmitted through the BS, put a single clean steering mirror in the ITMY chamber, and get the beam out of the ITMY door.  This could either be the beam before the ITM, or we could yaw the ITM a little and take the reflected beam.

  7379   Thu Sep 13 17:19:45 2012 JenneUpdateSUSMirrors being installed on active TTs

I have given Den 4 G&H R>99.99% mirrors to be installed on the 4 active tip tilts.  He's in there working on things (incl. installing and balancing the pitch of the mirrors) right now.  He'll elog his work later.

  7381   Thu Sep 13 23:27:14 2012 JenneUpdateGeneralPre-close checklist

We need to do the following things:  Images of optics in DRMI chain, place black glass beam dumps, make sure pickoff beams get out, align IP POS/ANG.

Black glass: behind MMT1, behind IPPOSSM3, forward-going POP beam.

Images and pickoff stuff should happen at the end of each vent.

Images need to be taken of the following optics (with ruler edge at center of optic):

* PZT1

* MMT1

* MMT2

* PZT2

* PRM

* PR2

* PR3

* BS (front and back?)

* ITMX

* ITMY

* SR3

* SR2

* SRM

* OM1

* OM2

* OM3

* OM4=PZT3

* OM5=PZT4

* OMPO

* OM6

* Viewport as AS beam leaves chamber

* POYM1 (check no clipping on edge of mount)

* POXM1 (check no clipping on edge of mount)

Pickoff / aux beams:

* REFL path

* POX

* POY

* POP

* IPPOS

* IPANG

  7383   Fri Sep 14 00:56:13 2012 JenneUpdateGeneralDRMI aligned

[Rana, Jenne]

We aligned the DRMI, and have concluded that it looks good enough that we should close up and pump down soon. We still need to use the camera to check things, and get all pickoff beams out of the chambers, so don't get too excited yet.

We looked at the mode matching telescope's calculated beam propagation, and since we're using spherical telescope mirrors at non-zero degree incidence angle, we expect an astigmatism about like what we are seeing on the AS camera.  This matches up with the measurements that Mike posted from his and Q's measurements earlier today.  We think that it has 'always' been this way, and someone just picked a camera position such that the beam used to look more round than it does now.

We aren't entirely sure what's up with the SRM - it almost looks like the pitch and yaw are coupled, but it was pretty easy to align the PRMI.  We don't see any evidence of the crazy, crappy beam that we did before the vent.  This means we have fixed most of the bad clipping problems we were seeing over the last ~year.

In the process of aligning the DRMI, we fixed up the input beam alignment - we were not hitting the exact centers of the MMT mirrors (in pitch, mostly), so we fixed that, and propagated the alignment fix through the chain.  In all, we touched the knobs on PZT1, MMT1, MMT2, PZT2.  The beam then went through the SRM, and we touched a few of the output steering mirrors to get the beam centered on all mirrors. 

I remeasured the MC spot positions, and they're a little worse than they have been.  Some of the spots seem to be off by 1.75mm (or less) on MC 1 and 3.  The numbers, MC1,2,3 pitch, then MC1,2,3 yaw are:   1.749759        9.744013        1.025681        -0.791683       -1.338786       -1.779958

A question to consider before doing the final-final alignment checking is: do we need to get the MC spots centered better than this, especially in light of the potential PMC axis having moved? 

  7387   Fri Sep 14 12:51:43 2012 JenneUpdateSUSNeed risers for active TTs

I was helping Den get started in the cleanroom yesterday, and I noticed that the new active TTs, like the old passive ones, are set to be 4" from the table.  So, like the old ones, we need 1.5" risers to get the center of the mirror up to our in-vac 5.5" beam height.  I didn't see any risers in there when I was looking around. 

Steve says he still has the drawing that he gave to the shop for the old tip tilts, so he'll double check that the dimensions are the same, and then ask the shop to make 4 more.

  7390   Fri Sep 14 18:18:33 2012 JenneUpdateGeneralIn Vac Pictures

Quote:

After much fussing, we got a picture of MMT1 with the beam.

Using the iris doesn't seem feasible. Since it has to be significantly separated from the optic, it is hard to judge whether it is centered, especially in yaw.

It took ~30 min to get this picture. Comments on whether this kind of picture is good enough are welcomed, since there are many more to be taken.

 I've been taking more photos.  Obviously, it gets quicker as I go along and get the hang of it.  Also, I've been taking overhead pictures with the Nikon so we can see what kind of parallax there is for each snapshot.

However, I just took MMT2, and the beam is nearly falling off the side of the optic!  It seemed fine last night when Rana and I were working on it.  The MC spots haven't moved significantly (I had measured yesterday, and again a few hours ago).  WTF?

This means that I need to move the knobs of MMT1, and then redo the whole alignment chain all over again.  Lame.

 

EDIT:  MC spot positions, last night at 12:33am, and this afternoon at 2:12pm:

                        year month day hour minute       MC1pit         MC2pit          MC3pit            MC1yaw         MC2yaw          MC3yaw

./data_spotMeasurements/MCdecenter201209140033.dat      1.749759        9.744013        1.025681        -0.791683       -1.338786       -1.779958      
./data_spotMeasurements/MCdecenter201209141412.dat      1.702974        7.916438        0.986519        -0.888736       -0.170237       -1.771267

 

  7391   Fri Sep 14 18:28:25 2012 JenneUpdateGeneralIn Vac Pictures

All the photos so far:

PZT1:

pzt1_light.jpg

MMT1:

mmt1.jpg

MMT2:

mmt2.jpg

PZT2:

pzt2.jpg

IPPO:

ippo.jpg

  7393   Sat Sep 15 18:29:25 2012 JenneUpdateGeneralMore photos taken

{EricQ, Jenne]

More photos were taken.  Will post Monday, because too hungry now.

  7397   Mon Sep 17 13:39:32 2012 JenneUpdateGeneralMore photos taken

Quote:

{EricQ, Jenne]

More photos were taken.  Will post Monday, because too hungry now.

 Have eaten.  Here's a PDF with all the pictures to-date, along with a few notes.

Also, the first thing we did on Saturday was to fix the yaw pointing of MMT1, so that the beam hit the center of MMT2.  Then we had to touch PZT2 to compensate.  We put the iris target on the BS, and adjusted PZT2 until the beam went nicely through there.  The resulting beam looks good on the SRM, and teh beam is still hitting the AS camera.

  7399   Mon Sep 17 20:23:31 2012 JenneUpdateGeneralLast of In-vac mirror photos taken

[Manasa, Jenne]

We took the last of the in-vac photos of mirrors today.  I'll post in the morning.

Tomorrow, I'll align the DRMI once more to check, and get IPPOS and IPANG out of the vacuum.  I'll  take a look at POX, POY and POP, but we may just have to cross our fingers and hope for the best on those ones.  They were pretty hard to get out of the vac during their initial alignment, since they're so weak.

Also, tomorrow morning Steve is going to try out our new light access connector!!!!  I'm so excited!

The goal is to put heavy doors on, on Wed, and start pumping Wed afternoon / Thurs evening.

  7401   Tue Sep 18 11:53:12 2012 JenneUpdateGeneralLast of In-vac mirror photos taken

Quote:

[Manasa, Jenne]

We took the last of the in-vac photos of mirrors today.  I'll post in the morning.

Tomorrow, I'll align the DRMI once more to check, and get IPPOS and IPANG out of the vacuum.  I'll  take a look at POX, POY and POP, but we may just have to cross our fingers and hope for the best on those ones.  They were pretty hard to get out of the vac during their initial alignment, since they're so weak.

Also, tomorrow morning Steve is going to try out our new light access connector!!!!  I'm so excited!

The goal is to put heavy doors on, on Wed, and start pumping Wed afternoon / Thurs evening.

 The photos on the OMC table are particularly tricky, since the camera plus the 'bathroom' mirror add a lot of weight....even if the MC locked, the input beam would be completely different, so all of the beams would be wrong.

During some of the work on the BS table, ITMY was realigned to have its beam retro-reflect, since the weight of the camera plus mirror was shifting all of the suspended optics on the BS table.  ITMY was restored after that, for subsequent photos.

  7402   Tue Sep 18 18:24:50 2012 JenneUpdateGeneralScattering in BS chamber or ITMX chamber

I have touched PZT2 such that the beam goes through the 45 degree non-iris target on the beam splitter.  This puts the beam at the center of ITMY, and without moving the BS, at the center of ITMX.  I say "at the center", but what I really mean is I put the target approximately at the center, within what looks like, say, 2 mm, by looking from above.  The target was many (5ish) centimeters away from the optic though, so that's why my side-to-side centering isn't so precise.  Given that, the beam was always more than half going through the hole of the target for both ITMs, so I'm claiming that the spots on the ITMs are within a few mm of center.

With this alignment, the beam was also hitting the center of the SRM (with all the same caveats).

I was able to get the SRM to retroreflect, while I still had Michelson fringing, so I think that I had the SRMI at least close to aligned (I was looking at the SRM retroreflection at the beam splitter, not all the way out to the AS port).  PRM is also pretty easy to align.

We're hitting the top of the AS camera, so I think things are pretty good.  I don't see beam on the REFL camera, but no investigation of that has been done as yet.

There is some scattering going on in the BS / ITMX chambers that's making me kind of unhappy.  I don't know how to get this to embed the youtube video, so here's the embed link, as well as the regular link:

youtube of AS and BS/PRM camera.

<iframe width="420" height="315" src="http://www.youtube.com/embed/QUbnMLXSS5U" frameborder="0" allowfullscreen></iframe>

Manasa watched the camera while I waved an IR card around in the BS chamber, and the only way I was able to get all the scatter spots to go away was to either block the beam incident on the BS (duh), or block the beam reflected off the BS, heading to ITMX.  Manasa said that the scatter spots still looked like they were fringing though, so I'm confused.  I may wave a card around in the ITMX chamber when I come back later tonight, to see what I can see.  Also, I just misaligned the SRM, and the scatter spots moved.  Now there's just some scatter off of what looks like the BS OSEM holders, as seen through the BS optic.

  7405   Wed Sep 19 01:08:48 2012 JenneUpdateGeneralDRMI aligned again

The DRMI was aligned once again tonight. 

Here's a video: http://youtu.be/Cy8nHL9yMeM  (Can someone please tell me / remind me how to make the elog embed videos?!?)

Description of video:

Video capture of AS camera.
NOTE: The beam is a few centimeters above ETMY with this alignment, so it will not be final.

Beginning is ITMY only.
ITMX is realigned to form MICH.
PRM is realigned to form PRMI.
SRM is realigned to form DRMI.
PRM is misaligned to form SRMI.
ITMX is misaligned to form SRY.

With this alignment, I opened up the ETMY door to find the beam there.  The beam is ~half on, ~half off of the top of the glass baffle.  Not the top of the hole, but the top of the piece of glass.  This means that it's many centimeters too high at ETMY.  This helps explain why, while swinging PZT2 around the other day, I could not see any beam on the cage.  It did, however, look pretty close (within a centimeter....I didn't look closer than that since it was so off in pitch) to centered yaw-wise.

Tomorrow I'd like a Clean assistant to help tweak PZT2 to hit the center of ETMY.  We'll need to put the 45 degree target back on to make sure that we don't end up pointing funny down the arm.  Then I'll realign the DRMI one more time.

Tonight, I can't check the full AS path, or any of the REFL path once it diverges from the main path.  Steve's new contraption (which is awesome!) doesn't have doors/windows yet, so I can't open it to get an IR card anywhere near any optics in the IOO or OMC chambers.  I waved PRM around a bit, but I can't find the beam on the REFL camera, so I definitely need to check that whole path again before we close up.

So, we're not closing up tomorrow, but progress has been made, and we're getting closer.

Note to self:  These are the ITMX, ITMY, PRM, BS, SRM biases with this DRMI alignment.  The DRMI is good, but the arms aren't, so these won't be final.  The saved alignments are still those with (for the Yarm) the beam bouncing several times between ITMY and ETMY.  BS was aligned at the time to hit the center of ETMX, and PRM and SRM should be retro reflecting in that alignment.  So, it's possible, that aligning PZT2 to hit the center of ETMY and restoring all of the optics will get me close to being back to DRMI aligned, but in a condition that the arms are align-able too.

  7406   Wed Sep 19 01:15:15 2012 JenneUpdateGeneralLast of In-vac mirror photos taken - NOT!

I'm making a separate entry to go along with this thread of photos...

Putting the camera and 'bathroom' mirror on any table pretty significantly changes the leveling of any table.  The mirror especially is very heavy, although the camera is not feather light.  We need to come up with a new plan for taking alignment-confirming photos without adding anything to the tables.  That, or we have to level the table between each camera shot.  Anyone who has ever leveled one of our in-vac tables should shudder in horror at idea #2, so we need to put some thought into idea #1 before our next vent.  Vent Czar - can you put this on the list, in addition to the REFL rearrangement stuff?

As a result of this, PZT2 needed to be reverted to the place it was before work began on Saturday (so that the beam goes through the 45 degree target without any extra stuff on the table).  This means, unfortunately, that all of the photos / still captures of optics after PZT2 are invalid.

  7410   Wed Sep 19 13:12:48 2012 JenneUpdateIOOPower into vacuum increased to 75mW

The power buildup in the MC is ~400, so 100mW of incident power would give about 40W circulating in the mode cleaner.

Rana points out that the ATF had a 35W beam running around the table in air, with a much smaller spot size than our MC has, so 40W should be totally fine in terms of coating damage.

I have therefore increased the power into the vacuum envelope to ~75mW.  The MC REFL PD should be totally fine up to ~100mW, so 75mW is plenty low.  The MC transmission is now a little over 1000 counts.  I have changed the low power mcup script to not bring the VCO gain all the way up to 31dB anymore.  Now it seems happy with a VCO gain of 15dB (which is the same as normal power).

  7413   Wed Sep 19 19:38:37 2012 JenneUpdateGeneralSpot centered on BS, ETMY, ETMX

[Unni, Manasa, Jenne]

It turned out that the beam was a teeny bit high in the corner, so we touched PZT1 and PZT2 knobs to translate the beam down a bit.

Now the beam is centered on the BS (using the 45 degree non-iris target), centered on ETMY (using Steve's latest target, which worked perfectly), and then BS was aligned a tiny bit (really, it didn't need much) to get the beam centered on ETMX.

After dinner I'll align ITMX and ITMY such that their beams retroreflect and I get MICH fringes.  I'll also align SRM and PRM to retroreflect.  Check no clipping on AS path, get REFL path out, center IPPOS and IPANG, check POX, POY and POP.  Then, I think we might be almost done.

  7415   Thu Sep 20 01:28:14 2012 JenneUpdateGeneralDRMI aligned again, but with good arms

[Jenne, Manasa]

Using the alignment of the PZTs and BS from pre-dinner, where the beam was hitting the center of both ETMs, we aligned the DRMI.  The beam was off on the SRM in yaw by ~half a beam diameter, so I undid Koji's movement of SR2 from a week ago.  I loosened the SR2 dog clamps, touched it gently on the base to do a little bit of angle, then re-clamped it.  Once again, Steve's new brass centering target was awesome, since it was on the SRM while I was moving SR2. 

We approximately recentered the beam on the AS camera, although it didn't need much once we got the beam out of the vacuum, by centering it on all of the output AS path mirrors.

We also got IPPOS out of the vacuum.  Manasa was in the process of centering the QPD when the laptop died from too long being unplugged, so we leave that for tomorrow.

Left to do:

REFL path.  REFL is not coming out of the vacuum, and with the light access connector I can't reach any of the REFL steering mirrors, since they're in the center of the IOO table.

IPANG.  Should be easy.

POP, POX, POY.  Need to the the camera-on-a-stick back down to the corner (from ETMY) and point it at the pickoff mirrors to ensure that beam is getting out of the vacuum.

  7420   Thu Sep 20 14:55:06 2012 JenneUpdateGeneralPickoffs are hard to see

Quote:

 My hope is that the DRMI flashes will be bright enough to see on the PO beams. IF we get 10 mW through the Faraday, you should get some buildup when the carrier resonates in the DRMI.

If the recycling gain is 10 and the pickoff fraction is 100 ppm you ought to get ~10 uW on PO. How much of the recycling cavity power gets out of POP?

 [Manasa, Jenne]

We think this math is wrong.

If we have P mW through the Faraday, PRM's transmission is 5.5%, BS transmission is 50%, Recycling gain is ~10, pickoff fraction is ~100ppm, we have:

P mW * 5.5e-2 * 0.5 * 10 * 100e-6 = P * 2750e-8 mW = P * 2.7e-5 mW.

So, if P=10 (10mW through the Faraday), we should have 2.7e-4 mW = 2.7e-7 W = 0.27 microwatts = not so many watts.    

If P = 100 (100mW through the Faraday), we should have 2.7 microwatts. Still, not so many watts.

We have the Watec pointed at POY right now, DRMI is flashing, I'm waving the IR card in front of the mirror, and Manasa isn't able to see anything on the monitor.  The power into the vacuum is 100mW (we just measured and adjusted it), so even if we were getting a full 100mW through the Faraday, it would be hard to see.  If we're assuming we get ~half the power through the Faraday, then we should only have 1 microwatt

  7421   Thu Sep 20 17:05:26 2012 JenneUpdateGeneralREFL, IPANG are coming out of the vac

[Jenne, Unni, Manasa]

I touched some in-vac steering mirrors, so we have REFL and IPANG coming out of the vacuum, not clipping.  IPPOS was done yesterday.  I re-checked a few optics in the AS path that were hard to see yesterday while the plastic light access connector was in place, and AS still looks good.

Except for POX, POY, POP, and putting the regular EQ stops back on PRM, I think we're done with the in-vac stuff.

  7422   Thu Sep 20 19:56:05 2012 JenneUpdateGeneralPickoffs are hard to see

Quote:

Quote:

 My hope is that the DRMI flashes will be bright enough to see on the PO beams. IF we get 10 mW through the Faraday, you should get some buildup when the carrier resonates in the DRMI.

If the recycling gain is 10 and the pickoff fraction is 100 ppm you ought to get ~10 uW on PO. How much of the recycling cavity power gets out of POP?

 [Manasa, Jenne]

We think this math is wrong.

If we have P mW through the Faraday, PRM's transmission is 5.5%, BS transmission is 50%, Recycling gain is ~10, pickoff fraction is ~100ppm, we have:

P mW * 5.5e-2 * 0.5 * 10 * 100e-6 = P * 2750e-8 mW = P * 2.7e-5 mW.

So, if P=10 (10mW through the Faraday), we should have 2.7e-4 mW = 2.7e-7 W = 0.27 microwatts = not so many watts.    

If P = 100 (100mW through the Faraday), we should have 2.7 microwatts. Still, not so many watts.

We have the Watec pointed at POY right now, DRMI is flashing, I'm waving the IR card in front of the mirror, and Manasa isn't able to see anything on the monitor.  The power into the vacuum is 100mW (we just measured and adjusted it), so even if we were getting a full 100mW through the Faraday, it would be hard to see.  If we're assuming we get ~half the power through the Faraday, then we should only have 1 microwatt

 We can't mathdo

  7423   Thu Sep 20 20:07:38 2012 JenneUpdateGeneralREFL, IPANG are coming out of the vac

Quote:

[Jenne, Unni, Manasa]

I touched some in-vac steering mirrors, so we have REFL and IPANG coming out of the vacuum, not clipping.  IPPOS was done yesterday.  I re-checked a few optics in the AS path that were hard to see yesterday while the plastic light access connector was in place, and AS still looks good.

Except for POX, POY, POP, and putting the regular EQ stops back on PRM, I think we're done with the in-vac stuff.

 [Rana, Jenne, Manasa]

POX is coming out of the vacuum.  We'll do POY tomorrow.  We were able to hold the Watec outside the chamber and focus it on the pickoff mirror, and make sure it was roughly centered.  Then we took the lens off the camera, put the camera in the POX beam path, and I steered the pickoff mirror until we were hitting the camera.  POY will be done the same way.

POP is more challenging, since the transmission of the G&H mirrors is so low.  We're not able to see a beam on an IR card held in the POP beam path.  I had thought of removing PR2, getting the beam out, then putting PR2 back (using the same dog clamping some alignment markers technique that we use for the test masses), but the G&H mirrors have a 2 degree wedge, so this won't work.  It would be fine for pitch, since the arrow is on the side of the optic, but it wouldn't be correct for yaw.

Maybe we should do something similar to what Suresh et. al. did when they set POP up originally - I think they put a green laser pointer on the POX table, and aligned it such that they were hitting the correct spot on PR2 and PRM (correct = the same as the IR spot, which should be the center of the optics).  If we can do that with the POP in-vac steering mirrors, then we're fine, and POP should come out when we're back to high power.

All video capture snapshots of tonights pictures are on the pianosa desktop.

  7426   Fri Sep 21 20:48:24 2012 JenneUpdateGeneralPOP in-vac optics aligned, POY beam coming out of vac

Getting POP:

We put a green laser pointer at ~4 inches on the POX table, and steered it using a mirror on the POX table to hit the center of the last in-vac mirror that POP sees.  I then steered that mirror so we were hitting the center of the other POP in-vac steering mirror, and hitting the same spot as the main IR beam.  It is easy to hold an IR card in front of PR2 and see the IR and green beams simultaneously.  I aligned both of the POP in-vac steering mirrors such that the green beam is co-aligned with the IR beam at PR2, as well as as far as I could reach toward the face of PRM from the ITMX door. 

Note:  The drawings by Koji have the POP "forward" beam (transmission through PR2 of the beam from PRM to PR2) dumped, while the POP "backward" beam (transmission through PR2 of the beam from PR3 to PR2) leaving the vacuum.  I aligned the steering mirrors such that the 'forward' beam would come out, although no dump is in place to dump the other beam.  I can't think of a reason why we care one way or the other, but I feel like Koji has perhaps mentioned something in the past.  I need to figure this out before we put doors on.

Getting POY:

Like yesterday with POX, we used the Watec with the aperture fully open to look at the POY pickoff, while I held the IR card in front of the mirror, to confirm that the beam was ~on the center of the optic. Then we took the lens off the camera, and made sure that the POY beam hit the CCD on the POY table.

 

To do list for Monday: While we are putting the heavy doors on, someone needs to wave an IR card in front of the IPANG steering mirrors in the ETMY chamber, while someone else takes a photo / still snapshot with the Watec.  Also, Manasa wanted to retake in-vac photos of at least the ITMY chamber, since SR2 was moved a very slight amount.  Also, also, someone tall needs to put the regular EQ stops on the PRM face (we have the old spring ones in there now).

Before pumpdown, we also need to get the IPANG beam centered on the PD.  The beam is cleanly coming out of the vacuum and hitting the first out of vac steering mirror, I just haven't centered it onto the QPD. 

Barring any other thoughts that people have of things that *must* be done before we pump down, I think we're ready to start putting heavy doors on the chambers on Monday.

Other thoughts, for next vent:  We need to re-look at the ITMY table.  POY's pickoff is just too close to the main beam.  Is it possible to move the AS steering mirrors and get POY from the BS table?  VENT CZAR: please put looking at this on the next vent to-do list.

  7432   Mon Sep 24 16:59:31 2012 JenneUpdateVACDoors on, ready to pump

[The 40m Family]

The access connector and all heavy doors are back on. 

Jamie put the regular viton EQ stops back on PRM, since he had to adjust the distance between the EQ stops and the PRM anyway.  Jamie also waved an IR card near the IPANG steering mirrors in ETMY, but it was not possible to take a good photo.  Jamie certifies that the beam is centered on both of those 2 optics.

I have centered IPPOS and IPANG QPDs. 

All oplevs need a little realignment, especially ETMY, which had it's lens removed (Rana has a Wall of Shame photo of this, which is why it was removed by him).  Steve will look into this tomorrow, after he starts pumping.

I have turned off all PZT high voltage supplies for in-vac PZTs: The input PZTs, the output PZTs, and the OMC PZTs (which weren't on, but I confirmed they were off).

I have also prepared the 3 low-power items for high power: MC refl's path was changed back to regular BS, AS camera was moved to its nominal position, and IPPOS has its ND filters back.  MC refl and the AS camera will need to be realigned once we're actually at high power tomorrow afternoon.

Long vent, but good work everyone.

  7433   Mon Sep 24 17:03:39 2012 JenneUpdatePEM1X1 rack power

Quote:

I've installed Guralp readout box back and it turned out that it does not work with voltage provided from the rack (+13.76 0 -14.94).  +/-12 voltage regulators inside the box convert it to -0.9 0 -12. I've connected the box to +/-15 DC voltage supply to measure seismic motion at the ETMY table. Readout box works fine with +/- 15.

 I'm not sure what the problem is here.  Den and I looked at it for a few minutes, before I went back to helping with putting doors on.  The Sorensons are not supplying the rack power for 1X1.  There are some flat cables which go from the fuses on the side of the rack up to the cable tray, and go elsewhere.  Den is going to continue looking into this, but I think it's a moderately high priority, since lots of things should be getting served by that same power.

  7437   Tue Sep 25 14:29:07 2012 JenneUpdateGeneralPOP in-vac optics aligned, POY beam coming out of vac

Quote:

  What was the reasoning / resolution of the POP forward/backward beam? Are we going to have the right beam for DRMI locking?

From Koji's email to me:

"With the backward beam you can see the returning beam even when the PRM is misaligned. That's the only difference. Once the PRM is aligned both beams have the same information."

So, we should be fine.

  7439   Tue Sep 25 22:40:55 2012 JenneUpdateIOOIPANG ND filter installed

[Jenne, Evan Hall]

Both IPPOS and IPANG beams are (after turning on the input and output PZTs) hitting their QPDs.  However IPANG was saturating.  We went down to take a look, and we had ~2.8mW incident on the QPD.  There was an ND filter sitting unmounted, next to the diode, and an empty fork directly in front of the diode.  Since IPPOS also has an ND filter in front, we stuck this ND filter back in.  Now we are no longer saturating.

We're not hitting (yet) the center of these 2 PDs, but we're at least hitting the diodes, so it shouldn't be too hard to steer the input PZTs.

Whomever took away this ND filter without elogging it was BAD!!!  (Jamie, when we first found IPANG coming out of the vacuum during this vent, we moved some of the mirrors on the out-of-vac table in the IPANG path.  Was the ND filter removed at that time?  Or has it been out for much longer, and we never noticed because IPANG wasn't coming nicely out of the vacuum / was clipping on the oplev lens?)

  7440   Wed Sep 26 01:10:34 2012 JenneUpdateIOOPZT2 not working?!?! MC back to normal

[Jenne, Evan, Den]

MC REFL beam is back on the PD, and the mode cleaner locks.  It looks like we're a little high on the MC Refl camera, but the MC spots were measured, and don't look like they changed from Friday (or maybe Monday?), the last time they were measured. We took this to be acceptable MC alignment, and did not touch the PSL table's pointing.

The laser power reduction optics were removed, and placed out of the way on the PSL table (where do they belong?).  PSL-POS and PSL-ANG aren't quite perfectly centered, but a beam dump had been in the way of that path, so I don't know if they drifted bad, or if it was a sudden thing.  The beam is still hitting the QPDs though.  After removing the beam power reducing optics, we recentered the MC REFL beam on the REFL PD, still not touching any PSL alignment.  MC mirrors were aligned (Den did this work while I showed Evan around, so I don't know by how much), and MC Trans was maximized (really MC Refl was minimized, making sure that the unlocked MC Refl was the usual 4.something units on the EPICS readback.

We turned on the PZT high voltage supplies for the output steering PZTs and for the input steering PZTs.  We left the OMC locking PZT supplies off, since we're still not using the OMC.  Sadly, the beam coming out of the AS port looks clipped somewhere.  [SELF: attach the videocapture shot when you get to work tomorrow] We tried moving PZT2's sliders, but nothing happened!!! I can move BS and the ITMs to get the beam mostly unclipped, but I really need to be able to move the PZTs, or at least one of them.  IPPOS and IPANG beams are hitting the QPDs (although they're not centered perfectly), so the PZTs came back mostly to the same positions, but not exactly.  Evan and I sat next to the input steering PZT controllers in 1Y3, and moved the sliders around.  For most of the range, nothing changes on the LCD screen for either PZT2 pitch or yaw.  Yaw can make 2 small steps near the far negative side of the slider, but nothing happens for most of the slider.  Pitch really doesn't do anything for any part of the slider.  We ensured that the LED labeled "CL ON" was not illuminated, next to the button labeled "closed loop", for all 4 controllers (PZT1 and 2, pitch and yaw).  Sad!!   I don't know if the LCD screen on the front panel of the PZT controllers is a readback of signal supplied to the PZTs, or of the strain gauges.  I really hope it's the controller that's not working, rather than the PZTs themselves.  The PZTs were fine before we vented, and Koji and I did our centering of the PZT range check during the vent, so they were fine then.  What happened???  All PZT high voltage supplies were off during the pump-down.  I turned them off yesterday, and Evan and I turned them back on tonight around 9:30pm or 10pm.  What else could make them bad?

Without being able to move PZT2, just using BS and / or ITMs, I was unable to completely make the beam look nice on the AS camera.  I came close, but it still seems a little bit funny, and I had to move the suspended optics quite a bit to find that place.  This is not good. 

  7444   Wed Sep 26 23:55:14 2012 JenneUpdateIOOWFS centered

Since the MC spots are good, I put the beam back on WFS 1 and WFS 2.

Also, I changed the indicators on the LockMC screen to reflect the change in elog 7289, where we added another on/off switch for the WFS so that the ASS could be on, but the WFS off.  For the last month, the WFS could be disabled, but the MC screen's indicators would suggest that we were pushing very significantly on all 3 MC mirrors.  Now the MC screen reflects reality a little better.

I also uncommented the WFS lines in the mcup script.  Den had commented them out, but didn't elog about it!  C'mon Den, please elog stuff!!!!  (He confessed out loud the other day, but it still wasn't in the elog).

I'm leaving the WFS loops disabled (even though the MC autolocker tries to turn them on, I have them manually disabled using the extra on/off switch) since they're unstable.  I'm in the process of figuring out what's wrong.  So far, the WFS improve the MC alignment for a minute or two, and then they totally misalign the MC.  This is a work in progress.

  7455   Mon Oct 1 11:08:25 2012 JenneUpdateIOOMC WFS adjustment

Quote:

Found a bug in the IOO screen: All of the 6 WFS signal indicators is liked to the same info (C1:IOO-MC1_PIT_OUTPUT).
Fix this, Jenne! Baaaaagghhhhh! 

 My bad.  As it turns out, you can't copy and paste between MEDM instances.  It is now fixed.

  7456   Mon Oct 1 13:11:43 2012 JenneUpdateIOOPZT inspection elogs

I'll come back to the PZTs later, but I want to write down all the elogs I have found so far that look relevant.

http://nodus.ligo.caltech.edu:8080/40m/699

http://nodus.ligo.caltech.edu:8080/40m/5368

nodus.ligo.caltech.edu:8080/40m/5431

  7465   Tue Oct 2 16:32:43 2012 JenneUpdateIOOPZT diagnosis

[Koji, Jenne]

Jamie and I pulled the whole PZT driver for both PZT1 and PZT2. 

Koji and I found that each HV power supply (the left-most module) has 2 fuses.  Both HV supplies (PZT1 and PZT2) have one blown fuse.  The "T2L250A" measures low resistance for both HV supplies, but the "T250mAL250V" measures Open for both HV supplies.

I have ordered 10 pieces of each kind of fuse, Next Day shipping, from DigiKey.