Entry  Thu Aug 15 01:51:50 2013, Koji, Summary, General, RFM<->Dolphin bridge distributed to c1rfm and c1mcs 
Entry  Tue Aug 13 22:21:12 2013, Koji, Summary, General, Minicircuit Filter TFs (AG4395A test) Minicircuit_LPF.pdfMinicircuit_BPF.pdfMinicircuit_HPF.pdf130813.zip
Entry  Tue Aug 13 21:49:32 2013, Koji, Summary, General, Testing new AG4395A network analyzer AG4395A_noise.pdf
Entry  Tue Aug 13 13:30:41 2013, Alex Cole, Configuration, Electronics, Cable Routing photo_(6).JPG
Entry  Tue Aug 13 11:54:40 2013, Alex Cole, HowTo, Electronics, RF PD Fiber-Coupled Laser Operation photo_(4).pdf
Entry  Tue Aug 13 11:40:19 2013, Alex Cole, Summary, Electronics, RFPD Demod Filter Frequency Response Measurement photo_(3).JPGtest.jpg
Entry  Tue Aug 13 11:04:44 2013, Steve, Update, PEM, fluorecent lights 
Entry  Fri Aug 9 22:51:37 2013, Koji, Update, LSC, PRMI(sb) lock recovered 
    Reply  Mon Aug 12 10:44:22 2013, rana, Update, LSC, PRMI(sb) lock recovered 
    Reply  Mon Aug 12 14:05:34 2013, Jenne, Update, ASC, PRCL ASS software in place 
       Reply  Mon Aug 12 15:39:40 2013, Jenne, Update, ASC, PRCL ASS screens in place 
       Reply  Mon Aug 12 17:30:03 2013, Koji, Update, ASC, PRCL ASS software in place 
          Reply  Mon Aug 12 23:13:14 2013, Jenne, Update, ASC, PRCL ASS software in place 
Entry  Thu Aug 1 12:12:35 2013, gautam, Update, CDS, New model for endtable PZTs C1ASX_GDS_TP.png
    Reply  Thu Aug 1 13:09:17 2013, gautam, Update, CDS, New model for endtable PZTs-procedure 
    Reply  Thu Aug 1 15:06:59 2013, jamie, Update, CDS, New model for endtable PZTs 
       Reply  Thu Aug 1 15:28:44 2013, gautam, Update, CDS, New model for endtable PZTs-problem solved 
    Reply  Thu Aug 1 20:58:56 2013, gautam, Update, CDS, New model for endtable PZTs-MEDM Screens setup MAIN_SCREEN.pdfMATRICES.pdfLOCKINS.pdfCONTROL_FILTERS.pdf
       Reply  Mon Aug 5 18:18:32 2013, gautam, Update, CDS, Choosing LO Amplitudes and Frequencies  GTR_Power_Spectrum.pdf
          Reply  Mon Aug 5 19:10:01 2013, Koji, Update, CDS, Choosing LO Amplitudes and Frequencies  
             Reply  Tue Aug 6 16:36:51 2013, gautam, Update, CDS, Choosing LO Amplitudes and Frequencies-revised powerSpec0806.pdf
                Reply  Wed Aug 7 23:40:49 2013, gautam, Update, CDS, X-End Green ASS - A first update time-series.pdf
                   Reply  Sat Aug 10 05:53:51 2013, gautam, Update, CDS, X-End Green ASS - Roundup New_ASX_MEDM_MAIN.pdf
                      Reply  Mon Aug 12 12:57:59 2013, Jenne, Update, CDS, X-End Green ASS - Roundup 
                         Reply  Mon Aug 12 13:30:33 2013, Jamie, Update, CDS, X-End Green ASS - Roundup 
Entry  Tue Aug 6 19:53:15 2013, Jenne, Update, LSC, Arms locked in IR, aligned. IFO at nominal power 
    Reply  Wed Aug 7 10:09:30 2013, Koji, Update, LSC, Arms locked in IR, aligned. IFO at nominal power 
       Reply  Wed Aug 7 21:52:11 2013, Jenne, Update, SUS, SRM coils fine - problem with slow bias slider 
          Reply  Fri Aug 9 21:05:28 2013, Koji, Update, SUS, fixed: SRM coils fine - problem with slow bias slider 
Entry  Thu Aug 8 21:25:36 2013, Koji, Update, General, Post-vent alignment cont'd 
    Reply  Fri Aug 9 16:49:35 2013, Jenne, manasa, Update, Electronics, Post-vent alignment cont'd - RFPDs 
Entry  Thu Aug 8 18:47:41 2013, Sujan, Summary, PEM, Using weiner filters for subtracting signals MC_L and GUR2_X Results.zip
Entry  Thu Aug 8 18:43:12 2013, Sujan, Summary, PEM, Optimally subtracting signals from two seismometers. Results.pdf
Entry  Thu Aug 8 11:18:46 2013, manasa, Update, Computer Scripts / Programs, Unused scripts in ASS moved 
Entry  Wed Aug 7 15:32:37 2013, Koji, Update, ASC, ASS setting up accelerated (slightly) 
    Reply  Wed Aug 7 19:16:20 2013, Jenne, Update, ASC, ASS setting up accelerated more 
       Reply  Wed Aug 7 22:18:43 2013, Koji, Update, ASC, ASS update Screenshot-Untitled_Window.png
Entry  Wed Aug 7 15:51:53 2013, Alex Cole, Configuration, Electronics, RF Switch Change photo_(2).JPG
Entry  Tue Aug 6 12:43:23 2013, Alex Cole, Configuration, Electronics, AS Table and Rack 1Y1 Additions photo_1_(5).JPGphoto_2_(5).JPG
Entry  Wed Jul 31 21:12:05 2013, manasa, Update, General, Pump down called off 
    Reply  Thu Aug 1 16:03:52 2013, Steve, Update, General, reopen BS & IOO IOOnorth.jpg
    Reply  Thu Aug 1 22:49:31 2013, manasa, Update, General, Green status after PR3 flipping investigated 
       Reply  Fri Aug 2 17:50:10 2013, Jenne, Update, General, PR3 wedge angle adjusted 
          Reply  Fri Aug 2 22:51:10 2013, Jenne, Update, General, All vent tasks complete, just need oplev check 
             Reply  Mon Aug 5 18:02:34 2013, manasa, Update, General, Close up list checked 
             Reply  Tue Aug 6 07:52:58 2013, manasa, Update, General, Ready to pump down MCspot_0806.pngOSEM_0806.pngOL_0806.pngQPD_0806.png
Entry  Tue Jun 25 19:18:07 2013, gautam, Configuration, endtable upgrade, plan of action for PZT installation 
    Reply  Wed Jul 3 21:19:04 2013, gautam, Configuration, endtable upgrade, plan of action for PZT installation DAC_bank.pngASC_schematic.pdf
       Reply  Mon Jul 8 13:45:19 2013, gautam, Configuration, endtable upgrade, Driver board verification 
          Reply  Wed Jul 10 22:41:06 2013, gautam, Configuration, endtable upgrade, PZT Driver Board HV_Amplifier.pdf
             Reply  Thu Jul 11 23:50:57 2013, gautam, Configuration, , PZT Driver Board-changes made ASC_schematic.pdfDAC_Max_output.JPG
                Reply  Mon Jul 15 11:51:18 2013, gautam, Configuration, endtable upgrade, DAC at 1Y4-Max Output and Power Spectrum max_amp.JPGmax_amp_all_channels.JPGDACOffPowerSpec.pdfDACOnPowerSpec.pdfDAC2kPowerSpectrum.pdf
                   Reply  Mon Jul 15 13:51:17 2013, Koji, Configuration, endtable upgrade, DAC at 1Y4-Max Output and Power Spectrum 
                      Reply  Mon Jul 15 15:54:20 2013, gautam, Configuration, endtable upgrade, DAC at 1Y4- Power Spectrum -with the right units DACOffPSD.pdfDAC500PSD.pdfDAC2000PSD.pdf
                         Reply  Mon Jul 15 17:20:43 2013, Jenne, Configuration, endtable upgrade, DAC at 1Y4- Power Spectrum -with the right units 
                            Reply  Mon Jul 15 17:59:31 2013, gautam, Configuration, endtable upgrade, DAC at 1Y4- Power Spectrum -6.4kHz bandwidth DAC-6.4_kHz_BW_PSD.pdf
                               Reply  Tue Jul 16 14:51:09 2013, gautam, Configuration, endtable upgrade, AI Board-D000186-Modified notches D000186_Frequency_Response.pdf
                                  Reply  Thu Jul 18 19:09:08 2013, gautam, Configuration, endtable upgrade, QPD Calibration for PZT Calibration QPD-XCalib.pdfQPD-YCalib.pdfError_Function_Fitting.zip
                                     Reply  Thu Jul 18 20:20:52 2013, gautam, Configuration, endtable upgrade, First mirror glued to PZT and mounted in modified mounts Piezo-mirror.jpg
                                        Reply  Thu Jul 18 23:34:40 2013, gautam, Configuration, endtable upgrade, Coarse adjustment of PZT axes orientation in mount PZT_out_waveform.jpg
                                           Reply  Fri Jul 19 23:35:31 2013, gautam, Configuration, endtable upgrade, Preliminary Calibration of PZT QPD-XCalib.pdfQPD-YCalib.pdfPiezo_Yaw_Calib-in_QPD_linear_range-Pitch_tilt.pdfPiezo_Yaw_Calib-in_QPD_linear_range-Yaw_tilt.pdf
                                              Reply  Tue Jul 23 20:41:40 2013, gautam, Configuration, endtable upgrade, Full range calibration and installation of PZT-mounted mirrors M1_Pitch_calib.pdfM1_Yaw_calib.pdfM2_Pitch_calib.pdfM2_Yaw_calib.pdfPI_S330.20L.pdf
                                                 Reply  Mon Aug 5 18:48:44 2013, gautam, Configuration, endtable upgrade, Full range calibration of PZT mounted mirrors for Y-endtable 2-inch-CVI-Yawcalib.pdf2-inch-CVI-Pitchcalib.pdf1-inch-Laseroptik-Yawcalib.pdf1-inch-Laseroptik-Pitchcalib.pdf
                                        Reply  Fri Jul 19 22:51:40 2013, gautam, Configuration, endtable upgrade, Second mirror glued to PZT and mounted  Piezo-mirror_2.JPG
                                           Reply  Tue Jul 30 19:44:05 2013, gautam, Configuration, endtable upgrade, Second mirror glued to PZT and mounted  
                                  Reply  Thu Jul 18 21:12:58 2013, gautam, Configuration, endtable upgrade, AI Board-D000186-All channels modified AI_Board_Output.jpg
                Reply  Mon Jul 29 13:39:25 2013, gautam, Configuration, endtable upgrade, PZT Driver Board-further changes D980323-C-modified.pdfD980323-C-modified-pg2.pdf
          Reply  Mon Jul 29 21:57:45 2013, gautam, Configuration, endtable upgrade, Hardware installed at 1X9 
             Reply  Tue Jul 30 19:40:47 2013, gautam, Configuration, endtable upgrade, DAC-PZT Driver Board Output Signal Chain Tested 
Entry  Thu Aug 1 22:58:45 2013, Charles, Update, ISS, CTN Servo - Explicit Requirement and Proposed Servo CTN_Servo_TF_-_Proposed_v_Req.pngCTNServo_v3.fil
    Reply  Mon Aug 5 11:53:45 2013, Evan, Update, ISS, CTN Servo - Explicit Requirement and Proposed Servo 
Entry  Fri Aug 2 21:59:36 2013, Charles, Update, ISS, Finalized ISS Schematic (hopefully)  ISS_v3.pdfISS_v3-Power_Reg.pdf
Entry  Thu Aug 1 21:28:09 2013, gautam, Update, CDS, Slow channels set-up in ALS  
Entry  Wed Jul 31 17:02:17 2013, Alex Cole, Update, Electronics, Preliminary Photodetector Frequency Reponse Measurements REFL11.jpgREFL33.jpgREFL55.jpgAS55.jpg
    Reply  Thu Aug 1 18:55:20 2013, Alex Cole, Update, Electronics, Preliminary Photodetector Frequency Reponse Measurements POX11.jpgPOX11fit.jpg
Entry  Thu Aug 1 16:33:39 2013, Sujan, Update, PEM, Guralp2 seismometer installed at North side of POX table IMG_1213.JPG
Entry  Wed Jul 31 10:27:00 2013, Steve, Update, VAC, instrument grade air is discontinoued 
Entry  Wed Jul 31 09:51:43 2013, Steve, Update, safety, Sujan receives safety training IMG_0031.JPG
Entry  Tue Jul 30 18:56:31 2013, manasa, Update, General, ITMX chamber vented/Closing plan 
    Reply  Wed Jul 31 00:59:58 2013, manasa, Update, General, ITMX chamber vented/Closing plan 
Entry  Tue Jul 30 16:21:46 2013, Alex Cole, Update, Electronics, Photodetector Input Modulation 
Entry  Fri Jul 26 22:45:14 2013, manasa, Update, General, Vent progress 
    Reply  Tue Jul 30 00:21:15 2013, Koji, Update, General, Vent progress 
       Reply  Tue Jul 30 11:30:55 2013, manasa, Update, General, ITMX oplev 
          Reply  Tue Jul 30 13:41:35 2013, Koji, Update, General, ITMX oplev 
             Reply  Tue Jul 30 15:38:24 2013, manasa, Update, General, ITMX oplev 
Entry  Sun Jul 28 20:13:41 2013, Annalisa, Update, Green Locking, Y Phase tracker calibration YbeatBox_Calibration.pdf
Entry  Sun Jul 28 19:39:04 2013, Annalisa, Update, endtable upgrade, Picture 
Entry  Thu Jul 18 21:45:36 2013, Charles, Update, ISS, ISS - Full Schematic 40mServo_v1.pdf
    Reply  Wed Jul 24 22:58:03 2013, Charles, Update, ISS, ISS - Full Schematic - Updated 40mServo_v1.pdf
       Reply  Fri Jul 26 22:19:24 2013, Charles, Update, ISS, ISS - Full Schematic - Updated 40mServo_v1.pdf
Entry  Fri Jul 26 14:39:08 2013, Charles, Update, ISS, Power Regulation for ISS Board 
Entry  Mon Jul 8 15:31:48 2013, Jenne, Update, ASC, POP QPD calibration prep 
    Reply  Tue Jul 9 11:41:22 2013, Jenne, Update, ASC, POP QPD calibration attempt 
       Reply  Tue Jul 9 16:08:32 2013, Jenne, Update, ASC, POP QPD calibration attempt 
          Reply  Fri Jul 12 21:23:42 2013, Jenne, Update, ASC, POP QPD calibration attempt ChangeVertMicrometer_July2013.pngChangeSideMicrometer_July2013.png
             Reply  Mon Jul 15 17:16:59 2013, Jenne, Update, ASC, POP QPD calibration attempt ChangeSideMicrometer_July2013_calib2.pngChangeSideMicrometer_July2013_calib1.pngChangeVertMicrometer_July2013_calib1.png
                Reply  Tue Jul 16 01:17:21 2013, Jenne, Update, ASC, POP QPD calibration attempt 
                   Reply  Tue Jul 23 01:30:27 2013, Jenne, Update, ASC, POP QPD analysis 9x
                      Reply  Fri Jul 26 13:39:30 2013, Koji, Update, ASC, POP QPD analysis 
Entry  Thu Jul 25 14:45:06 2013, rana, Update, PEM, Guralp specgram with ligoDV and NDS2 a.pdf
Entry  Wed Jul 24 13:41:13 2013, Jenne, Update, SUS, SR2 flipped 
    Reply  Wed Jul 24 15:07:54 2013, Koji, Update, SUS, SR2 flipped 
       Reply  Thu Jul 25 14:02:53 2013, Jenne, Update, SUS, SR3, PR3 flipped 
Entry  Thu Jul 25 13:54:35 2013, manasa, Update, General, PR3 clamped and Y arm is back flashing 
Entry  Thu Jul 25 12:53:45 2013, Charles, Update, ISS, Comparator + Triggering Prototype Comparator_Prototype.pngComp_Triggering_Behavior.jpg
Entry  Thu Jul 25 02:53:00 2013, Koji, Update, General, IFO Alignment after TT flipping - no progress 
Entry  Wed Jul 24 19:21:56 2013, Jamie, HowTo, SUS, SUS MEDM screen modernization newsusmedm.png
Entry  Tue Jul 9 11:37:37 2013, gautam, Update, CDS, set up for testing DAC Interface-board pin outs 
    Reply  Tue Jul 9 12:01:20 2013, gautam, Update, CDS, set up for testing DAC Interface-board pin outs 
       Reply  Tue Jul 9 18:44:37 2013, gautam, Update, CDS, DAC Interface Board-Pin Outs DAC_Interface_Board_Pin-out.pdfbreak-out_ribbon.JPG
          Reply  Tue Jul 23 04:07:48 2013, gautam, Update, CDS, Excitation points set up on c1scx 
             Reply  Tue Jul 23 16:47:01 2013, gautam, Update, CDS, Excitation points set up on c1scx 
                Reply  Tue Jul 23 19:38:58 2013, gautam, Update, CDS, Characterisation of DAC at 1X9 
Entry  Tue Jul 23 16:39:31 2013, Koji, Update, General, Full IFO alignment recovered alignment.png
Entry  Mon Jul 22 16:30:31 2013, Koji, Update, General, Vent preparation 
    Reply  Mon Jul 22 16:56:14 2013, Jenne, Update, General, Vent preparation - In progress 
       Reply  Mon Jul 22 17:03:25 2013, Jenne, Update, General, MC spot positions MCdecenter_22July2013.png
          Reply  Tue Jul 23 04:26:54 2013, Jenne, Update, General, MC spot positions MCdecenter_22July2013_lowpower.png
       Reply  Mon Jul 22 18:49:16 2013, Jenne, Update, General, Vent preparation - In progress 
       Reply  Mon Jul 22 21:23:04 2013, manasa, Update, General, Vent preparation - In progress 
          Reply  Tue Jul 23 03:10:57 2013, Koji, Update, General, Vent preparation - In progress OSEM_RECORD.pngOPLEVS.png
          Reply  Tue Jul 23 03:43:32 2013, manasa, Update, General, Vent preparation - In progress 
             Reply  Tue Jul 23 04:22:03 2013, Koji, Update, General, Vent preparation - In progress 
       Reply  Tue Jul 23 04:31:36 2013, Jenne, Update, General, Vent preparation - Ready for Vent 
          Reply  Tue Jul 23 08:21:31 2013, Steve, Update, VAC, Vent has started beforVent.pngstartVent.png
             Reply  Tue Jul 23 14:00:03 2013, Steve, Update, VAC, the vent is completed Atm.png5cyl.pngventSum1d.png
Entry  Tue Jul 23 13:55:08 2013, Koji, Update, IOO, MC manually aligned MCalignment.pngMCspot.png
Entry  Tue Jul 23 13:29:58 2013, Koji, Summary, General,  initial_state_130723.png
Entry  Mon Jul 22 03:10:41 2013, rana, Summary, lore, Angel of the Y End Table? asdasd.jpg
    Reply  Mon Jul 22 06:58:17 2013, Lisa, Summary, lore, Angel of the Y End Table? image.jpg
Entry  Mon Jul 22 03:09:51 2013, Annalisa, Update, Green Locking, Y Arm cavity scan Screenshot-scan3_0722.pdf_-_Adobe_Reader.png
Entry  Fri Jul 19 23:35:52 2013, Koji, Summary, LSC, TRY DC locking TRY_locking.png
Entry  Fri Jul 19 22:35:06 2013, Koji, Summary, LSC, Various Arm signal (Yarm) various_arm_signal.png
Entry  Fri Jul 19 12:23:34 2013, manasa, Update, CDS, CDS FE not happy Screenshot-Untitled_Window.png
    Reply  Fri Jul 19 14:04:24 2013, Koji, Update, CDS, CDS FE not happy 