    Reply  Tue Jan 7 23:50:27 2014, jamie, Update, CDS, /frames space cleared up, daqd stabilized 
The wiper script is done and deleted a whole bunch of stuff to clean up some space:

controls@fb ~ 0$ /opt/rtcds/caltech/c1/target/fb/wiper.pl --delete

Tue Jan  7 23:09:21 PST 2014

Directory disk usage:
/frames/trend/minute_raw
385927520k
/frames/trend/second 125729084k
/frames/full 12552144324k
/frames/trend/minute 2311404k
Combined 13066112332k or 12759875m or 12460Gb

/frames
    Reply  Tue May 13 17:45:21 2014, rana, Update, CDS, /frames space cleared up, daqd stabilized 
 
 Late last night we were getting some problems with DAQD again. Turned out to be /frames getting full again.
I deleted a bunch of old frame files by hand around 3AM to be able to keep locking quickly and then also ran the wiper script (target/fb/wiper.pl).
    Reply  Thu May 15 01:42:07 2014, rana, Update, CDS, /frames space cleared up, daqd stabilized 
 Script seems to be working now:
nodus:~>df -h | grep frames
fb:/frames              13T    12T   931G    93%    /frames
Entry  Tue Aug 20 16:23:41 2013, rana, Summary, General, /home/cds nearly full 
/home/cds is >98% full - below are some of the usage numbers:
controls@rosalba:/users/OLD 0$ du -h --max-depth=1
42M    ./katrin
    Reply  Wed Aug 21 17:42:03 2013, rana, Summary, General, /home/cds nearly full 
One of the reasons that our disk is getting full is due to the scripts_archive directory. A backup script runs on op340m and makes a tar.bz2 file of
the scripts directory and puts it in scripts_archive every morning at 6 AM.
On Oct 7, 2011, Koji fixed this script to point at our new scripts directory instead
    Reply  Fri Sep 20 20:14:52 2013, rana, Summary, General, /home/cds nearly full 


    
        
            Quote:
        
        
            

           One of the reasons that our disk is getting full is due to the scripts_archive directory. A backup script runs on op340m and makes a tar.bz2
Entry  Thu Feb 11 14:28:50 2016, Steve, Update, Treasure, 091415 declared 091415declared.jpgYou_were_right!.jpgP1080312.JPG
   Beautifully
Done

   Chirp
Entry  Fri Apr 6 15:06:05 2012, Den, Update, IOO, 1 Hz resonance psd_mcl.jpgmcl.jpg
I think we can try to damp 1 Hz resonance more. In September it was not seen because of the digital noise. After we've figured it out, 1 Hz resonance
began to be more clear (blue line).
Entry  Mon Aug 20 13:02:57 2012, Den, Update, Adaptive Filtering, 1 Hz resonance 1hz.png
Static filter was adjusted to filter 1 Hz resonance in MCL and it could do it. Stack is not great in this experiment due to the phase mismatch. I'll
fix it.
    Reply  Wed Feb 6 14:51:25 2013, Jenne, Update, Electronics, 1 power supply replaced! 


    
        
            Quote:
        
        
            

           Currently, DC power for amplifiers ZHL-1000LN+ is supplied by Aligent E3620A.
Entry  Wed Jul 7 19:41:27 2010, Jenne, Update, SUS, 1.5 more ECD sets suspended for tip tilts ECDbackplane_blackdump_small.jpgECDbackplane_foil_small.jpg
[Jenne, Kyung Ha]
We made some good progress on suspending the Tip Tilt ECDs today.  We finished one whole set, plus another half.  The half is because
one of the screw holes on the lower right ECD somehow got cross threaded.  The ECD and screws in question were separately wrapped in foil to mark
Entry  Tue Dec 17 20:59:23 2013, Jenne, Update, LSC, 1/sqrt(TR) signals added to frames 
I noticed that we have not been saving the 1/sqrt(TRX) and 1/sqrt(TRY) data, so I modified the c1lsc model and added them to the DAQ channels block. 
I restarted the c1lsc model, and the _DQ channels are now archived.
    Reply  Mon Jun 1 19:19:26 2009, rana, Update, PSL, 1000 days of hour-trend u.png
 
Entry  Fri Oct 18 08:12:08 2013, Steve, Update, PEM, 1000 days trends trend1000days.png
 
Entry  Fri Apr 21 13:59:47 2017, Eric Gustafson, Summary, , 1064 nm Semiconductor Laser Fiber Distribution System and Mirror Tomography 
1064 nm Semiconductor Laser Fiber Distribution System and Mirror Tomography

Below threshold these Semiconductor Fabry-Perot lasers have an axial mode structure with a spacing of about a THz. As you turn up the current
to above threshold the first mode to oscillate saturates the gain down on all the modes and only it oscillates.  The laser I have here in my office
Entry  Wed Mar 3 18:32:25 2010, Alberto, Update, 40m Upgrading, 11 MHz RFPD elctronics rfpd11_v2_TF.pdfrfpd11_v2_Noise.pdf
** Please add LISO file w/ component values.
 
I designed the circuit for one of the 11 MHz photodiodes that we're going to install
in the 40m Upgrade.
This is a simple representation of the schematic:
    Reply  Thu Mar 4 08:43:35 2010, Alberto, Update, 40m Upgrading, 11 MHz RFPD elctronics rfpd11_v2.fil


    
        
            Quote:
        
        
            
            ** Please add LISO file w/ component values.
    Reply  Wed Oct 10 02:15:14 2012, rana, Update, LSC, 11 MHz reconnected to EOM 
 Absolutely hokey. What are our requirements for this RFPD? What are the power levels and SNR that we want (I seem to remember that
its for 22 as well as 110 MHz)? Perhaps we can test an aLIGO one if Rich has one sitting around, or if the aLIGO idea is to use a broadband PD I guess
we can just keep using what we have.
Entry  Mon Aug 18 09:19:55 2008, steve, Summary, VAC, 11 days at atm ventprm.jpg
It took 11 days to fix earth quake triggered sus problems of ITMX, SRM and PRM
Only ITMX north and BSC north vac doors were removed.
Entry  Fri Sep 7 12:28:09 2012, Koji, Update, LSC, 11&55MHz modulations turned off 
11MHz modulation source was turned off (disabled) at Marconi at 12:00.
    Reply  Tue Aug 27 18:21:35 2013, Jenne, Configuration, Electronics, 110 MHz LO options 
As I see it, we have a few options for getting the 110 MHz LO to both the POP110 and AS110 demod boards.  
The current situation is described by Kiwamu in elog 5746.  The 55 MHz signal comes
into the box, and is split 4 ways, with each path having 19.7 dBm.  One of these 4 is for 110.  It has a 2dB attenuator (giving us ~17.7 dBm),
    Reply  Tue Aug 27 18:58:52 2013, Koji, Configuration, Electronics, 110 MHz LO options 
- Do we have an appropriate amplifier?
- True challenge could be to find a feedthrough for the new port. (or to find a space for the amplifier in the box)
- PDXXX channels is on the DC whitening filter module. There could be some modification on this module (like diabling the whitening gain selector).
Entry  Tue Apr 21 11:55:05 2015, Steve, Update, Optical Levers, 1103P noise measurement 1103P@qpdBS.jpgoplev1103P.pngoplevSum1103Pbs.png
Manasa and Steve,

Is this what you want?  Dashed lines are dark.

BS and PRM oplevs are blocked for this measurement. I will restore to normal operation at 4pm today.
    Reply  Tue Apr 21 15:03:27 2015, rana, Update, Optical Levers, 1103P noise measurement 
It doesn't work with the lens in there, but it seems pretty close. Please leave it as is and I'll play with it after 5 today.
    Reply  Tue Apr 21 21:46:34 2015, rana, Update, Optical Levers, 1103P noise measurement oplev1103P.pngL1-ISI_SUS_ODC_FC496F_SPECTRUM-1113523216-86400.png
To test what the inherent angular noise of the HeNe 1103P laser is, we're testing it on a table pointing into the BS OL QPD with only a few steering
mirrors.

From the setup that I found today, I've removed the lens nearest to the laser (which was used for the BS and PRM) as well as the ND filter
Entry  Mon Apr 30 22:58:57 2012, Jenne, Update, Electronics, 11MHz Marconi set to default after power outage 
After a power outage, a Marconi comes back to it's defaults.  It needed to be reset to the values in elog 5530. 
I'm putting a label on the Marconi so we don't have to look it up next time.
Before fixing the Marconi, POY11, AS11 and AS55 all looked like noise, no real signals, even though the arm is flashing.  Now they all look
Entry  Thu Mar 4 19:53:56 2010, Alberto, Update, 40m Upgrading, 11MHz PD designed adjusted for diode's resistance; 55 MHz RFPD designed 6x
After reading this
study done at LIGO MIT in 1998 I understood why it is difficult to define an effective impedance for a photodiode.

I read a few datasheets of the C30642GH photodiode that we're going to use for the 11 and 55
    Reply  Thu Mar 4 22:07:21 2010, rana, Update, 40m Upgrading, 11MHz PD not yet designed 
Use 10 Ohms for the resistance - I have never seen a diode with 25 Ohms.
p.s. PDFs can be joined together using the joinPDF command or a few command line options of 'gs'.
    Reply  Fri Apr 15 15:15:08 2011, kiwamu, Update, LSC, 11MHz demod board : 90 degree splitter 
[Rana, Koji, Kiwamu]
 Moreover the amplitude of the I and Q signals are highly unbalanced, depending on the LO power again.
This implies the coil for a 90 degree splitting won't work at 11 MHz since the coil is home made and used
    Reply  Sat Apr 16 02:00:14 2011, rana, Update, LSC, 11MHz demod board : 90 degree splitter 
One way to avoid some of the bad stuff in there is to take the 1 dBm input and amplify it to ~21 dBm before splitting and sending in to the Level 17
mixers.
One way to do this is by using the A3CP6025 from Teledyne-Cougar. Its
Entry  Fri Apr 15 12:17:39 2011, kiwamu, Update, LSC, 11MHz demod board : funny I-Q phase relativephase.png
During checking the 11MHz demod boards I found that the I-Q relative phase showed
funny LO power dependence.
It is now under investigation.
Entry  Tue Oct 9 23:12:56 2012, Jenne, Update, LSC, 11MHz reconnected to EOM 
Riju hasn't been in the lab in a long time to do any measurements, so I put the signals back to how they should be.  
I  turned off / confirmed off the things which were sending signal to the  EOM:  the network analyzer, the RF generator box, and the Marconi
which  supplies the 11MHz.  
Entry  Mon Feb 10 18:03:41 2014, jamie, Update, CDS, 12 core c1sus replacement 
I have configured one of the spare Supermicro X8DTU-F chassis as a dual-CPU, 12-core CDS front end machine.  This is meant to be a replacement for
c1sus.  The extra cores are so we can split up c1rfm and reduce the over-cycle problems we've been seeing related to RFM IPC delays.
I pulled the machine fresh out of the box, and installed the second CPU and additional memory that Steve purchased.  The machine seems to
Entry  Thu Feb 24 17:42:00 2011, Aidan, Update, Green Locking, 15% of end laser sideband power transmitted through cavity 
I did a quick calculation to determine the amount of sideband transmission through the FP cavity.
The modulation frequency of the end PDH is 216kHz. The FSR of the cavity is about 3.9MHz. So the sidebands pick up about 0.17 radians extra phase
on one round trip in the cavity compared to the carrier.
Entry  Wed Apr 19 15:46:24 2017, gautam, Update, General, 1611/1811 inventory check 
I looked through the lab area to do a fast photodiode inventory check, as we may need to buy some for the higher order mode spectroscopy SURF project.
I looked on the following optical tables: ETMY, ITMY, BS, AS, PSL, SP, ITMX, Jenne laser table, and ETMX, as well as the photodiode cabinet, and could
only find two 1611s. Here is a summary of the inventory: 
Entry  Thu Dec 10 13:10:25 2009, Alberto, Configuration, LSC, 166 LO Disconnected 
I temporarily disconnected the Heliax cable that brings the 166MHz LO to the LSC rack.
I'm doing a couple of measurement and I'll put it back in as soon as I'm done.
    Reply  Thu Dec 10 18:31:44 2009, Alberto, Configuration, LSC, 166 LO Disconnected 


    
        
            Quote:
        
        
            
            I temporarily disconnected the Heliax cable that brings the 166MHz LO to the LSC rack.
    Reply  Fri Dec 11 09:30:09 2009, Koji, Configuration, LSC, 166 LO Disconnected 
They must not be dBm, must be dB 


    
        
            Quote:

       
        
            
            
            
    Reply  Fri Dec 11 11:42:26 2009, Alberto, Configuration, LSC, 166 LO Disconnected 


    
        
            Quote:
        
        
            
            They must not be dBm, must be dB 
            
   
    Reply  Fri Dec 11 14:12:32 2009, rana, Configuration, LSC, 166 LO Disconnected 
 
 Seems like very strange cable loss numbers. The Heliax is lossier than the RG-174? I wonder how these compare with the specs in the cable
catalog?
    Reply  Fri Dec 11 19:51:13 2009, Alberto, Configuration, LSC, 166 LO Disconnected 


    
        
            Quote:
        
        
            
             
Entry  Thu Dec 10 17:05:21 2009, Alberto, Configuration, LSC, 166 MHz LO SMA-to-Heliax connection repaired 
I replaced the SMA end connector for the 166 MHZ Local Oscillator signal that goes to the back of the flange in the 1Y2 rack. The connector had got damaged
after it twisted when I was tigheting the N connector of the Heliax cable on the front panel.
Entry  Mon Jan 25 16:30:37 2010, Alberto, Update, ABSL, 166 MHz sideband turned off 
I turned off the modulation at 166MHZ becasue I don't need it if I'm only locking the PRC.
It was introducing extra amplitude modulations of the beam which interfered with the AbsL's PLL photodiode.
I'm going to turn it back on later on.
    Reply  Mon Jan 25 16:46:33 2010, Alberto, Update, ABSL, 166 MHz sideband turned off 


    
        
            Quote:
        
        
            
            I turned off the modulation at 166MHZ becasue I don't need it if I'm only locking the PRC.
    Reply  Tue Jan 26 03:28:56 2010, rana, Update, ABSL, 166 MHz sideband turned off 
 
 You can turn the 166 off if you want. MZ is unhappy after its turned off, but that's just the thermal transient from removing the RF heat.
After a several minutes, the heat goes away and the MZ can be relocked.
Entry  Thu Jan 28 09:17:32 2010, Alberto, Update, LSC, 166 Modulation turned off 
I temporarily turned off the 166 modulation.
Entry  Fri May 1 01:32:43 2009, Yoichi, Update, Locking, 166MHz LO phase adjustment 
I continued to adjust the REFL_2I demodulation phase.
I first optimized the demod phase for SRCL in the DRMI configuration (the error signals were DDs).
Then I restored the full IFO and offset locked it.
    Reply  Fri May 1 10:04:10 2009, rob, Update, Locking, 166MHz LO phase adjustment 
[quote]I continued to adjust the REFL_2I demodulation phase.
I first optimized the demod phase for SRCL in the DRMI configuration (the error signals were DDs).
Then I restored the full IFO and offset locked it.
Entry  Thu Apr 30 05:49:06 2009, Yoichi, Update, Locking, 166MHz LO phase changed 
In order to optimize the REFL_2I demod phase, I changed the delay line setting for the 166MHz LO.
Right now, the delay is not yet optimal.
Since the AS166 shares the same LO, the digital demodulation phase of the AS166 had to be changed too.
    Reply  Tue Nov 17 20:57:43 2015, ericq, Update, CDS, 16Hz frame writing running again 
Back to nominal FB configuration at 1131857782, aka Nov 18 2015 04:56:05 UTC.

Weirdly, during this time, the script watching MC_TRANS_SUM from pianosa saw tons of freezes, but another instance  watching LSC-TRY_OUT16
on optimus saw no freezes. 