  357   Tue Mar 4 20:14:02 2008 ranaConfigurationIOOMC AlignmentThe MC alignment was pretty far off. We were
getting TEM01 mode locks only. 
Rather than inspect what happened I just
  
  363   Fri Mar 7 00:47:54 2008 ranaConfigurationPEMRanger SS-1Yesterday evening around 7:30 PM, I changed
the Ranger seismometer from a 
vertical to a horizontal seismometer. To
 ss1.pdf 
  367   Mon Mar 10 20:46:41 2008 JohnConfigurationLSCETMY Trans PD & QPDI've placed a 10% reflector in the path from
ETMY to the trans and quadrant photodiodes.
  
  368   Tue Mar 11 23:14:01 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsSteve and Matt moved the accelerometers and
seismometers today. 
The accelerometers are now placed around
 Acc.pdf 
  369   Wed Mar 12 00:36:52 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsI used the MISO FIR Wiener matlab code to
see how well we might do in principle.
 finished.pdf 
  370   Wed Mar 12 00:40:35 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsSame as above but with 2048 taps and a 128
Hz sample rate. Does much better at the 16
Hz bounce mode.
 mc2048-128.pdf 
  371   Wed Mar 12 00:47:26 2008 ranaConfigurationPEMAccelerometer and Seismometer movementsAnd this is a [COLOR=blue]cool snapshot[/COLOR]
showing how this operation used [B][COLOR=red]16
cores[/COLOR][/B] on [SIZE=5][B][COLOR=purple]menkar
 Screenshot.png 
  373   Thu Mar 13 02:52:06 2008 LisaConfigurationLSCLocking with 3fToday we have tried to use the reflected signal
demodulated at 3*f1 ~ 99 MHz ([COLOR=chocolate][B]REFL31[/B][/COLOR])
for length control.
  
  378   Fri Mar 14 12:06:29 2008 josephbConfigurationCamerasGC750 looking at ETMX while lockedThe GC750 (CMOS) is currently looking at the
front of ETMX.  Unfortunately, its being
routed through a 10Mbit connection (which
 ETMX_zoom_exp_10000_750.tiff 
  379   Fri Mar 14 14:59:51 2008 josephbConfigurationCamerasComparison between GC650 (CCD) and GC750 (CMOS) looking at ETMXAttached are images taken of ETMX while locked.

The first two are 300,000 microsecond exposure
 ETMX_z2_exp_300000_650.tiffETMX_z2_exp_300000_750.tiffETMX_z2_exp_30000_650.tiffETMX_z2_exp_30000_750.tiff 
  381   Fri Mar 14 15:52:07 2008 robConfigurationLSCLSC code change
I've edited the LSC code to send different
signals to the ASS box.  Now, instead of
  
  383   Sun Mar 16 17:03:32 2008 robConfigurationCDSASS code change
I've updated the ass.mdl file in the directory:
  
  384   Mon Mar 17 18:30:48 2008 mevansConfigurationPEMAdaptive FilteringIt seems that adaptive filtering can achieve
results similar to those of the MISO FIR
Wiener (entry 369).  The adaptive code simulates
 mcacc_adaptive.png 
  386   Thu Mar 20 16:06:27 2008 robConfigurationLSCLSC code change
I changed the LSC code again.  I noticed
that when turning off the LSC (e.g., going
  
  390   Fri Mar 21 17:01:21 2008 ranaConfigurationDMFLocale change on Mafalda & seisBLRMS restartEver since we moved the accelerometers to
be around the MC and changed their names,
the seisBLRMS
  
  391   Fri Mar 21 23:15:11 2008 ranaConfigurationPEMRanger SS-1: New SetupThe Ranger seismometer has been in a bad state.
Its output had been sent into a SR560 without
any termination.
  
  392   Fri Mar 21 23:17:47 2008 ranaConfigurationDMFseisBLRMS restartedI updated the seisBLRMS par file with the
new channel names of the accelerometers and
the seismometer and then
  
  412   Thu Apr 3 18:46:04 2008 AndreyConfigurationComputers"Network switch board" and "c1pem1 crate" were touched
While working with the weather station, I
did two things that potentially (with a very
 Computer_Rack.JPG 
  418   Tue Apr 8 09:08:54 2008 steveConfigurationPEMweather station disconnectedWe can not leave cables in the walkways and
go on vacation.
I disconnected the weather station from the
 toast.jpg 
  419   Tue Apr 15 18:44:25 2008 ranaConfigurationComputersRosalbaThere is a new computer in the control room
-- its called [B][COLOR=purple]Rosalba[/COLOR][/B],
in keeping with our naming convention. Its
  
  434   Tue Apr 22 08:34:22 2008 josephbConfigurationCamerasCurrent Network DiagramThe attached network diagram has also been
added to the 40m Wiki at http://lhocds.ligo-wa.caltech.edu:8000/40m/Image_Processing_with_GigE_Cameras
 Network.pdf 
  439   Tue Apr 22 22:51:30 2008 ranaConfigurationIOOMcWFS StatusI've been working a little on the MC WFS in
the last few days. I have made many 
changes to the sensing matrix script and
  
  443   Thu Apr 24 15:57:53 2008 steveConfigurationSAFETYSafety at AP-ISCTI measured the output power of the psl after
the mechanical shutter.
 P1020197.JPGmcrefl3.JPG 
  447   Fri Apr 25 11:33:40 2008 AndreyConfigurationComputersComputer controlling vaccum equipment
[COLOR=blue]Old computer[/COLOR] (located
in the south-end end of the interferometer
  
  451   Fri Apr 25 20:53:02 2008 ranaConfigurationIOOMC WFS with more gainQuick update: we found that the reason for
the MC WFS instability was that the digital
anti-whitening was one but not the analog
  
  454   Sun Apr 27 02:11:11 2008 ranaConfigurationIOOMC WFS NotesAs noted in the elog from Friday, the WFS
has been bad ever since someone switched
on the digital whitening filters (FM1 & FM2)
  
  455   Sun Apr 27 05:09:30 2008 ranaConfigurationIOOMC WFS Whitening turned onI [B]hardwired on the MC WFS whitening[/B]
filters.
 mcnoise.png 
  463   Thu May 1 12:46:02 2008 josephbConfigurationComputersNodus gateway is upThe computer Nodus is now acting as a gateway
machine between the GC network and the martian
network in the 40m.  It has the same passwords
  
  466   Tue May 6 17:28:39 2008 robConfigurationLSCAP33 -> POX33
I am in the process of switching the POX166
and AP33 photodetectors, so that they become
  
  467   Wed May 7 15:25:41 2008 robConfigurationLSCAP33 -> POX33[quote]
I am in the process of switching the POX166
and AP33 photodetectors, so that they become
  
  471   Thu May 8 16:40:36 2008 josephbConfigurationCamerasGige Camera currently on PSL tableAndrey and myself were working on the PSL
table today, using a pickoff of a pickoff
of the main beam (adding a microscope slide
  
  479   Thu May 15 12:05:49 2008 josephbConfigurationPSLPath to PSL Position QPDThe 50/50 beamsplitter that was being used
as the last turning mirror to the PSL Position
QPD has been replaced with a Y1-1037-45-S
  
  486   Sun May 18 18:59:15 2008 ranaConfigurationComputerscron and hostsI added rosalba to the hosts file for the
control room machines (131.215.113.103).
  
  489   Tue May 20 18:33:01 2008 Andrey, JohnConfigurationIOOMode Cleaner is locked again
It was noticed by Mr.Adhikari earlier today
that the MC became unlocked at about 11AM.
  
  492   Thu May 22 11:25:19 2008 josephbConfigurationComputers One of the new Netgear Prosafe 24 port switches
was mounted in the 1X4 rack,, roughly in
the middle, away from the top and bottom
  
  495   Sun May 25 16:20:27 2008 ranaConfigurationComputersjoinPDFI have installed joinPDF 2.1 on rosalba. Since
its written in Java, I didn't have to tinker
with it at all to work on a 64-bit machine.
  
  498   Sun May 25 21:14:14 2008 tobinConfigurationComputersEPICS proxy serverI set up an EPICS gateway server on Nodus
so that we can look at 40m MEDM screens from
off-site.
  
  500   Tue May 27 16:24:54 2008 tobinConfigurationComputer Scripts / ProgramsndsproxyThe NDS Proxy is a program that accepts NDS
(LIGO Network Data Server) connections from
the internet and relays them to
  
  501   Wed May 28 12:51:32 2008 josephbConfigurationComputersTwo more switches mountedTwo more Prosafe 24 port switches have been
mounted in the racks, one in 1Y9 and one
in 1Y6.  (The first one was placed in 1X4).
  
  506   Fri May 30 12:03:08 2008 josephb, AndreyConfigurationCamerasHead to head comparison of camerasAndrey and myself - Joseph B. - have examined
the output of the GC650 (CCD) and GC750 (CMOS)
prosilica cameras.  We did several live motion
 Waveform_Reconstruction_May30-2008.pdf 
  508   Fri May 30 21:30:15 2008 tobinConfigurationComputerssvn on solarisI installed svn on op440m.  This involved
installing the following packages from sunfreeware:
  
  509   Sun Jun 1 19:25:10 2008 ranaConfigurationComputersnew monitor on op440mI installed the new 24" flat screen on op440m.
I increased the screen resolution from 1280x1024
to 1900x1200 using
 Andrey-440.jpgBusby08.jpg 
  510   Sun Jun 1 19:39:35 2008 tobinConfigurationComputerselog, etcPhil Ehrens gave me a DVD of the 40m elog,
apache, and (Jamie's) SVN archive.
I copied it to nodus:/home/controls/dvd-from-ehrens.
  
  513   Tue Jun 3 10:19:45 2008 tobinConfigurationComputersbig machineSeveral of us transported the big new awesome
Sun box from Bridge over to 
the 40m last week.  If I recall correctly,
  
  514   Tue Jun 3 10:40:27 2008 tobinConfigurationComputersnew dataviewerAlex let me know the secret location of the
latest dataviewer executable for Linux. 
It is:
  
  517   Wed Jun 4 13:46:42 2008 josephbConfigurationCamerasChanging incident angle imagesAttached are images from the GC650 and GC750
when the incident angle was varied from 0
tilt (normal incidence) to 5,10, and 20 degrees.
 GC650_0dg_5dg.pdfGC650_10dg_20dg.pdfGC750_0dg_5dg.pdfGC750_10dg_20dg.pdf 
  519   Wed Jun 4 16:57:12 2008 josephbConfigurationCamerasDark images from cameras (electronics noise measurement)The attached pdfs are 1 second and 1 millisecond
long integrations from the GC650 and GC750
cameras with a cap in place - i.e. no light.
 GC650_1sec_dark.pdfGC650_1msec_dark.pdfGC750_1sec_dark.pdfGC750_1msec_dark.pdfGC650_1sec_dark_zoom.pdf 
  520   Thu Jun 5 10:46:26 2008 josephbConfigurationCamerasApproximately uniform reflected white lightIn an attempt to investigate the structures
seen in previous images for the GC750, I
aimed it at a relatively clean section of
 GC650_white_light.pdfGC750_white_light.pdf 
  521   Thu Jun 5 13:35:23 2008 josephbConfigurationCamerasGC750 looking at 1064nm scattered lightI've taken 200 images of the GC750 (CMOS)
camera while holding it by hand up to a beam
card (also held by hand) in the path of ~5mW
 GC750_HeNe_scatter_avg.pdfGC750_HeNe_scatter_avg2.pdfGC750_HeNe_scatter_avg3.pdfGC750_scatter_avg.pdfGC750_nitrogen_white.pdf 
  525   Fri Jun 6 16:47:04 2008 josephbConfigurationCameras GC650 scatter images of 1064nm lightTook images similar to the scattered light
images from earlier, except with the CCD
GC650 camera.  The first three attached plots
 GC650_scatter_200.pdfGC650_scatter_100a.pdfGC650_scatter_100b.pdf 