  10498   Fri Sep 12 00:40:23 2014 JenneUpdateLSCDRMI locking Tonight I worked on DRMI locking.
 
I think the reason the May2014 DRMI
  
  10500   Fri Sep 12 11:25:42 2014 KojiUpdateLSCDRMI lockingThis is great.
And I got confused. Is REFL11 going
through the CM board? 
  
  10501   Fri Sep 12 12:00:59 2014 ericqUpdateLSCDRMI lockingREFL11 I, as seen in digital land, is connected
to the slow output of the CM board. I tuned
the demod angle of the REFL11 demodulator
  
  10502   Fri Sep 12 14:11:17 2014 ericqUpdateLSCDRMI lockingWe
need to get an interferometric estimation
of the SRC length error / SRC sideband splitting,
 7x 
  10514   Wed Sep 17 15:40:00 2014 ericqUpdateLSCDRMI lockingI have not had any success the past two
days in getting an interferometric measurement
of the SRC length. 
 dcAngleDiff_srcL.pdfdrfpmiVertexSensing.zip 
  10527   Tue Sep 23 17:37:10 2014 ericqUpdateLSCDRMI lockingRather than using a CAD drawing, I used
Gabriele's code from ELOG
 9590 to try and judge if we could
 SRCcorrection.pdf 
  12951   Wed Apr 26 01:00:23 2017 gautamUpdateGeneralDRMI locking Since we'd like to get back to DRSE
locking, I tried locking the DRMI tonight.
I did the following:
 DRMI_1f_26April2017.pngIMG_7373.JPGIMG_7372.JPG 
  12954   Fri Apr 28 02:04:36 2017 gautamUpdateGeneralDRMI locking I got a couple of ~30min long DRMI lock
stretches today. The settings I used are
essentially the same as what I had back in
 20170428_DRMI.pdf 
  12955   Fri Apr 28 13:56:26 2017 ranaUpdateGeneralDRMI locking one of these signals does not look like
the others: explanation?
  
  12960   Mon May 1 16:29:51 2017 gautamUpdateGeneralDRMI locking For the traces I posted, I had not turned
on the whitening for the SRCL sensing PD
(REFL55). However, I took a spectrum on a
 LSC_sensingNoise.pdfIMG_7378.JPG 
  12962   Mon May 1 21:45:54 2017 ericqUpdateGeneralDRMI locking Comparing counts doesn't get you anywhere;
each PD has different whitening gain which
may vary from measurement to measurement.
  
  12969   Wed May 3 18:45:45 2017 ranaUpdateGeneralDRMI locking [quote]Comparing counts doesn't get you anywhere;
each PD has different whitening gain which
may vary from measurement to measurement.
  
  12957   Fri Apr 28 19:32:06 2017 gautamUpdateGeneralDRMI locking - PRCL angular FFI took a closer look at the POP QPD/ PRC
angular feedforward situation yesterday.
I thought it would be useful to have a 
 PRC_angularFF.pdfPRC_TFs.pdf 
  14162   Tue Aug 14 02:01:12 2018 gautamUpdateLSCDRMI locking - partial successAfter tweaking the AS55 demod phase, SRM
alignment, triggering settings, I got a few
brief
 DRMI.png 
  12972   Thu May 4 19:03:15 2017 gautamUpdateGeneralDRMI locking - preliminary MICH NBSummary:

 DRMI_noArms_April30.pdfMICH_OLTF.pdfC1NB_disp_40m_MICH_NB_30_April_2017.pdf40m_REFL_RFPDs_efficiency.pdf 
  13088   Fri Jun 30 02:13:23 2017 gautamUpdateGeneralDRMI locking attemptSummary:

I attempted to re-lock the DRMI
and try and realize some of the noise improvements
 BS_OLmods.pdf 
  13090   Fri Jun 30 11:50:17 2017 gautamUpdateGeneralDRMI locking attemptSeems like the problem is actually with
ITMX
- the attached DV plots are for ITMX with
 ITMX_glitchy.png 
  13248   Thu Aug 24 00:39:47 2017 gautamUpdateLSCDRMI locking attemptSince the single arm locking and dither
alignment seemed to work alright after the
CDS overhaul, I decided to try some recycling
  
  13252   Fri Aug 25 01:20:52 2017 gautamUpdateLSCDRMI locking attemptI tried some DRMI   
  13907   Thu May 31 23:12:17 2018 gautamUpdateLSCDRMI locking attemptSummary:

I wanted to recover the DRMI locking.
Among other things, Jon mentioned that his
 REFL55_whtCheck.pdf 
  13933   Fri Jun 8 01:58:56 2018 gautamUpdateLSCDRMI locking attempt againGiven the various changes to the IFO config
since last Thursday when I was last able
to lock the DRMI, I wanted to try once again
  
  13413   Tue Nov 7 22:56:21 2017 gautamUpdateLSCDRMI locking recoveredI hadn't re-locked the DRMI after the
work on the AS55 demod board. Tonight, I
was able to recover the DRMI locking with
 DRMI_7Nov20178.png 
  14285   Wed Nov 7 23:07:11 2018 gautamUpdateLSCDRMI locking recoveredI had some
success today. I hope that the tweaks I made
will allow working with the DRMI during the
 Screenshot_from_2018-11-07_23-05-58.pngSRCL2MICH_crosscpl.pdfPRCangularCoh_rot.pdf 
  13908   Fri Jun 1 01:22:50 2018 gautamUpdateLSCDRMI locking restoredAs it happened last time, the problem apparently
fixed itself - somehow the act of me disconnecting
the cables and reconnecting them seems to
 DRMI_20180531.png 
  13428   Wed Nov 15 01:37:07 2017 gautamUpdateLSCDRMI low freq. nosie improvedPianosa
just crashed and ate my elog, along with
 C1NB_disp_40m_MICH_NB_2017-11-15.pdfOL_A2L_couplings.pdf 
  6474   Sat Mar 31 08:01:07 2012 kiwamuUpdateLSCDRMI measurementI have measured the sensing matrix of the
DRMI although the lock still doesn't stay
for a long time.
  
  13431   Thu Nov 16 00:53:26 2017 gautamUpdateLSCDRMI noise sub-budgetsI've incorporated the functionality
to generate sub-budgets for the various grouped
traces in the NBs (e.g. the "A2L"
 C1NB_a2l_40m_MICH_NB_2017-11-15.pdfC1NB_aux_40m_MICH_NB_2017-11-15.pdf 
  4797   Wed Jun 8 23:17:25 2011 kiwamuUpdateLSCDRMI output matrix diagonalizationApproximately
two weeks ago I diagonalized the LSC output
matrix for the DRMI locking.
 Screen_shot_2011-06-08_at_23.21.28.png 
  4592   Sat Apr 30 00:15:26 2011 kiwamuUpdateSUSDRMI prep : suspension diagnosticAs a part of the DRMI preparation,
I leave all
  
  13093   Fri Jun 30 22:28:27 2017 gautamUpdateGeneralDRMI re-lockedSummary:

Reverted
to old settings, tried to reproduce DRMI
lock with settings as close to those used
 DRMI_relocked.pngMICH_OL.pdf 
  13094   Sat Jul 1 14:27:00 2017 KojiUpdateGeneralDRMI re-lockedBasically we use the arm cavities as the
reference of the beam alignment. The incident
beam is aligned such that the ITMY angle
  
  13281   Thu Aug 31 03:31:15 2017 gautamUpdateLSCDRMI re-locked!After our Demod/Whitening electronics investigations
suggested nothing obviously wrong, I decided
to give DRMI locking another go tonight.
 DRMI_1f.pngDRMI_relocked.pdf 
  10690   Sat Nov 8 16:01:32 2014 ericqConfigurationLSCDRMI sensingHere are some preliminary results from
the sensing sweeps I did the other night. 
Notes:
 6x 
  10693   Mon Nov 10 18:23:10 2014 ericqConfigurationLSCDRMI sensingARG, I accidentally permuted the digital
demod angles. This significantly weakens
the argument for believing AS55I is broken...
 REFL11.pngREFL33.pngREFL55.pngREFL165.pngAS55.png 
  9036   Mon Aug 19 23:08:31 2013 JenneUpdateLSCDRMI sensing signalsHere are a bunch of sensing signals. 
The configuration is always DRMI.  Except
for the optic noted in the title and the
 11x 
  6512   Mon Apr 9 18:18:14 2012 kiwamuUpdateLSCDRMI time seriesHere is a time series when the DRMI is
being locked.
You can see that the AS110 goes up
 time_series1.png 
  4760   Mon May 23 12:27:26 2011 kiwamuUpdateLSCDRMI trial : details(PRMI
locking with slightly misaligned SRM)
 First I tried locking PRC and
  
  4757   Sat May 21 06:19:46 2011 kiwamuUpdateLSCDRMI trial : no luckI will try with POY55 that Koji prepared
today.
  
  4759   Mon May 23 00:36:51 2011 kiwamuUpdateLSCDRMI trial : sucessEventually the
D
  
  11632   Tue Sep 22 03:48:18 2015 ericqUpdateLSCDRMI tweaked, briefly held with ALS armsGiven the RF component power supply grounding,
POP110, POP22 and REFL165 all changed somewhat.
They have all been rephased for the DRMI,
  
  252   Tue Jan 22 02:33:45 2008 robUpdateLSCDRMI work
0) The ETMY oplev needs work/centering
  
  366   Mon Mar 10 02:05:08 2008 robUpdateLockingDRMI+2ARMs working better
Some encouraging progress on the locking
front tonight.  After the work on the DRM
  
  10859   Tue Jan 6 17:41:20 2015 JenneConfigurationCDSDTT doesn't do envelopes??[Jenne, Diego]
We are working on trying out the
UGF servos, and wanted to take loop measurements
  
  2045   Fri Oct 2 18:04:45 2009 robUpdateCDSDTT no good for OMC channelsI took the output of the OMC DAC and plugged
it directly into an OMC ADC channel to see
if I could isolate the OMC DAC weirdness
 omc_dac_dtt.pngomc_dac_sweepTDS.pngomc_dac_dtt_ts.png 
  1718   Tue Jul 7 16:06:59 2009 ClaraUpdateComputer Scripts / ProgramsDTT synchronization errors, help would be appreciatedI am attempting to use the DTT program
to look at the coherence of the individual
accelerometer signals with the MC_L signal.
  
  14007   Fri Jun 22 15:13:47 2018 gautamUpdateCDSDTT workingSeems like DTT also works now. The trick
seems to be to run 
 Screenshot_from_2018-06-22_15-12-37.png 
  14008   Fri Jun 22 15:22:39 2018 sudoUpdateCDSDTT working


Quote:


  
  3107   Wed Jun 23 15:33:42 2010 josephbUpdateCDSDaily Downs UpdateI visited downs and announced that I would
be showing up again until all the 40m hardware
is delivered. 
  
  3119   Fri Jun 25 08:10:23 2010 josephbUpdateCDSDaily Downs UpdateYesterday afternoon I went to downs and
acquired the following materials:
2 100 ft long blue fibers, for use
  
  3134   Tue Jun 29 12:08:43 2010 josephbUpdateCDSDaily Downs UpdateI talked with Rolf, and asked if we were
using Megatron for IO.  The gist boiled
down to we (the 40m) needed to use it for
  