  5756   Fri Oct 28 14:56:02 2011 JenneUpdateCDSCSS/BOY installed on pianosa


   
        
            
  
  5757   Fri Oct 28 15:33:06 2011 JenneUpdateComputersNifty screen generatorSuresh showed me a cool script that Mirko
made, but didn't elog
  
  5772   Mon Oct 31 19:39:00 2011 JenneUpdateAdaptive FilteringScreens, code, computers[Mirko, Jenne]
I finished (mostly? maybe?) the OAF
screens.  They're pretty awesome. 
  
  5778   Tue Nov 1 18:45:48 2011 JenneUpdateComputersAllegra's screensI was trying to give Allegra a second head,
and it didn't quite work.  It's still
in progress.  Steve, you might not like
  
  5792   Wed Nov 2 22:02:39 2011 JenneUpdatePhotosNew screen snapshot script written!After lots of trial and error, and a little
inspiration from Koji, I have written a new
script that will run when you select "update
  
  5793   Thu Nov 3 13:00:52 2011 JenneUpdatePhotosFormatting of MEDM screen names

    

       
            
  
  5812   Fri Nov 4 15:26:54 2011 JenneUpdateLSCLSC model recompiledI moved the place where we take the OAF
Degree of Freedom signals from - now it's
the error point rather than the feedback
  
  5828   Mon Nov 7 11:50:42 2011 JenneUpdateelogRestarted elogElog restart script killed the elog, but
didn't restart it.  Restarted by hand.
  
  5830   Mon Nov 7 14:50:19 2011 JenneUpdateComputersISCEX is having a bad dayI clicked on the FE status screen, just
to check on things, and everything on the
c1iscex section was 
  
  5832   Mon Nov 7 15:15:21 2011 JenneUpdateLSCLSC model recompiled

    
        
  
  5835   Mon Nov 7 16:42:56 2011 JenneUpdateAdaptive FilteringBLRMS's to monitor OAF channelsI copied Mirko's PEM BLRMS block, and made
it a library part.  I don't know where
such things should live, so I just left it
  
  5848   Wed Nov 9 14:23:35 2011 JenneUpdateAdaptive FilteringOAF MC Delay MeasurementAs described in elog
2063 and the mevans
document, we need to measure the TF of
 OAF-MCL-Delay-9Nov2011.pdf 
  5853   Wed Nov 9 17:41:17 2011 JenneUpdateComputersETMX restoredJamie did computer magic.  I burt
restored scxepics, and restored ETMX damping.
  
  5861   Thu Nov 10 11:52:00 2011 JenneUpdateCDSRFM signal transferringI am not so happy with the control signals
that are coming into the OAF via the RFM/Dolphin/shmem. 
The MCL/MCF signal travels via RFM
 OAF_rfm_signals_MCL.pdfOAF_rfm_signals_MICH.pdfOAF_rfm_signals_PRCL.pdfOAF_rfm_signals_GUR1X.pdf 
  5862   Thu Nov 10 12:28:31 2011 JenneUpdateSUSMC2 is being a little wild...WFS to blameMirko and  Den are measuring MC_F,
which they will report about later, but I
noticed that MC2 is totally crazy right now. 
 WFSscreenshot.png 
  5865   Thu Nov 10 19:41:24 2011 JenneUpdateSUSMusings on SUS dewhitening, and MC ELP28'sThe
following will be a stream-of-consciousness,
approximately chronological story of my last
  
  5886   Mon Nov 14 12:16:41 2011 JenneUpdateComputersOAF model died for unknown reasonI am meditating on the OAF, and had it
running and calculating things.  I had
the outputs disabled so I could take reference
  
  5918   Wed Nov 16 21:01:08 2011 JenneUpdateTreasureeom boxI made a super sweet new foam box for our
EOM.  It's awesome, and should be reasonably
easy to duplicate.  Check out the 
  
  5921   Thu Nov 17 11:04:02 2011 JenneUpdateRF SystemStochmon?Is there an update on Stochmon?  Are
the signals acquired somewhere already? 
What's the current deal-io?  The new
  
  5922   Thu Nov 17 11:27:58 2011 JenneUpdatePSLHEPA turned downI was measuring things to see how big my
adapter plate needs to be, and I decided
that we'd had enough days of the HEPA being
  
  5924   Thu Nov 17 11:51:14 2011 JenneUpdateEnvironmentIncandescent vs. fluorescent lights?I'm just on an elog roll this morning...
Again while poking around inside
the IFO room, I noticed that they have replaced
  
  5951   Fri Nov 18 19:07:07 2011 JenneUpdateRF SystemFoam house on EOM[Jenne, Zach, Frank]
Frank helped Zach and I cable up
at PT-100 RTD, and make sure it worked with
  
  5966   Mon Nov 21 12:48:00 2011 JenneUpdateIOORFAM monitoring testI don't think I touched/adjusted/whatever
anything, but I did open the PSL table ~5-10min
ago to measure the size of the Kiwamu-Box,
  
  5967   Mon Nov 21 14:15:25 2011 JenneUpdateIOORFAM monitoring test

    
        
  
  5977   Tue Nov 22 14:39:50 2011 JenneUpdateelogAfternoon elog restartGave the elog its afternoon / tea-time
reboot, since it was hanging yet again.
  
  5988   Wed Nov 23 14:47:14 2011 JenneConfigurationEnvironmentAC in the IFO room was offI turned it back on, maybe around 11am? 
Definitely a little while before the 12:30
meeting.
  
  5997   Thu Nov 24 10:27:07 2011 JenneUpdateIOORFAMPD channels / EOM monitor channels added to DAQHere is a drawing of where the monitors
are coming from:
 EOM_temp_sense_heater_drive_schematic_withMONs.png 
  6022   Mon Nov 28 14:27:35 2011 JenneUpdateRF SystemEOM temp driverHere is 5 days of trend of the EOM temp
sensor and the heater driver monitor. 
Unfortunately, it looks like we're regularly
 EOM_temp_driver_3days.png 
  6030   Mon Nov 28 19:24:51 2011 JenneUpdateCDSBeware of fancy filter modules[Rana, Jenne]
Some of the funniness is some kind
of mysterious interaction between 2 filter
 SUSPOS_ETMY_30and0_measured_vs_idealTF.pdfSUSPOS_ETMY_Cheby_measured_vs_idealTF.pdfSUSPOS_ETMY_30and0andCheby_measured_vs_idealTF.pdfSUSPOS_ETMY_30and0andCheby_compareCoherence.pdfSUSPOS_ETMY_30and0andCheby_compareCoherence.pdf 
  6048   Wed Nov 30 01:35:49 2011 JenneUpdateCDSOSEM noise / nullstream and what does it mean for satellitesI'm picking points off of this no-magnet
OSEM plot, and I thought I'd write them down
somewhere so I don't have to do it again
  
  6054   Wed Nov 30 14:12:53 2011 JenneUpdateRF SystemNew EOM mount almost readyThe new EOM adapter plate and riser just
got back from the shop.  I just had
Mike do the milling, and I'll drill and tap
  
  6056   Thu Dec 1 01:24:56 2011 JenneUpdateRF SystemEOM temp stabilization at PSL lab[Frank, Jenne]
Activities in a far, far away land
called PSL lab...
 EOM_Temp_stab_30Nov2011.png 
  6070   Mon Dec 5 10:13:13 2011 JenneUpdateAdaptive FilteringC1OAF

    

       
            
  
  6073   Mon Dec 5 19:38:38 2011 JenneUpdateRF SystemEOM mount getting closer....I have drilled all the holes necessary,
and have tapped all but 4 of the holes for
the new EOM mount.  The adapter plate
  
  6077   Tue Dec 6 21:37:08 2011 JenneUpdateRF SystemNew EOM mount in placeEOM
is remounted on the fancy-pants new mount
that I crafted.  EOM is also aligned. 
  
  6082   Wed Dec 7 18:47:36 2011 JenneUpdateRF SystemRAM Mon is now being demodulatedThere were 2 open outputs on the splitter
in the RAMmon (formerly known as Stochmon)
  
  6089   Thu Dec 8 14:47:28 2011 JenneUpdateIOOEOM aligned to minimize RAM

    
        
  
  6090   Thu Dec 8 16:54:05 2011 JenneUpdateRF SystemInstallation of new demod boxSo far:
* New demod box has been placed in
the LSC rack.
  
  6096   Fri Dec 9 15:49:24 2011 JenneUpdateIOOMC trans is way downI was looking at the trends from the RAMmon,
since I did the EOM alignment yesterday,
and wanted to compare them to the MC trans,
 MCtrans_9Dec2011.png 
  6097   Fri Dec 9 17:08:41 2011 JenneUpdateRF SystemLots of current used in Rich's demod boxI checked the power regulators on the Rich
demod box (according to the schematic, D1000217). 
  
  6098   Fri Dec 9 17:15:29 2011 JenneUpdateIOOMC trans is way down

    

       
            
  
  6104   Mon Dec 12 11:16:02 2011 JenneUpdateRF SystemFoam house on EOMFoam house installed on EOM a few min ago. 
We'll leave it until ~tomorrow, then try
out the heater loop.
  
  6107   Mon Dec 12 15:24:21 2011 JenneUpdatePSLPMC and MC were both crappy - now realignedPMC trans was only ~0.79, where it should
be ~0.84 something.  The MC was also
not stellar. 
  
  6108   Mon Dec 12 16:30:17 2011 JenneUpdateComputersDid someone just do something to fb??Dataviewer couldn't connect to the framebuilder,
so I checked the CDS status screen, and all
the fb-related things on each model went
  
  6109   Mon Dec 12 16:57:38 2011 JenneUpdateRF SystemRAMmon, 4 day trendEOM was aligned to minimize the 11 and
55 MHz peaks in the RAMmon PD the other day
(elog
 EOM_tempSense_noFoam_noHeater_RAMmon_4days.png 
  6111   Tue Dec 13 11:34:32 2011 JenneUpdateRF SystemRAMmon, 5 day trendNow we've got another day of data, with
the foam box on for the last 24hrs.
First plot is a 5 day trend so you
 EOM_tempSense_RAMmon_5days_last_day_withFoam_noHeater.pngEOM_tempSense_withFoam_noHeater_RAMmon_1day.png 
  6119   Wed Dec 14 14:30:43 2011 JenneUpdateRF SystemLO for new demod boxThe Rich demod box wants 10dBm for the
local oscillator inputs, so I measured the
values that we have coming out of the distribution
  
  6123   Wed Dec 14 19:59:12 2011 JenneUpdateRF SystemLO for new demod box


   
        
            
  
  6157   Tue Jan 3 15:45:04 2012 JenneUpdateComputersFB?Is there a reason the framebuilder status
light is red for all the front ends?
Also, I reenabled PRM watchdog.
  
  6217   Mon Jan 23 15:43:47 2012 JenneUpdateIOOPMC realignment

    
        
  