ID Date Authorup Type Category Subject Text Attachments
  3447   Fri Aug 20 15:22:09 2010 JenneUpdateSUSTTs done!!![Yoichi, Jenne]
Hooray!!!
  
  3454   Mon Aug 23 00:08:24 2010 JenneUpdateelogJoe, I think this's your cue...    
  3459   Mon Aug 23 21:04:14 2010 JenneUpdateTreasureSeriously?Bad CDS team.
Bad.
 BadKiwamu_CDSsetup.jpg 
  3470   Wed Aug 25 15:42:01 2010 JenneUpdatePSLPSL Upgrade: Mode Matching from PMC to IMCThoughts on where to take the pickoff for
the SHG for the PSL-green?  We discussed
today at the meeting the possibility of putting
  
  3476   Fri Aug 27 11:24:13 2010 JenneOmnistructureComputersop540m deadI think op540m
has finally bitten the dust. 
  
  3482   Fri Aug 27 22:09:37 2010 JenneUpdatePSLThe beginnings of the new PSL[Rana, Jenne]
Like
 phoenix.jpg 
  3489   Mon Aug 30 18:35:22 2010 JenneUpdateWienerFilteringSecret Hiding Place for Raw DataAs it turns out, data seems to fall off
the 16Tb drives after ~20 days.  Which
makes it a good thing that I saved all of
  
  3511   Thu Sep 2 01:44:13 2010 JenneUpdatePSLPSL beam hitting the PMC![Rana, Jenne]
More PSL progress. 
The new laser was raised to a 4 inch
  
  3512   Thu Sep 2 01:48:23 2010 JenneFrogsTreasureNot cool....This totally creeped me out when I found
it wandering around on the floor not so far
from my desk:
 CreepyBug.jpg 
  3523   Fri Sep 3 23:42:34 2010 JenneUpdatePSLPSL update of the dayRana and I were poking around on the PSL
table today, getting a few more items raised
to the correct height.
  
  3734   Mon Oct 18 11:22:13 2010 JenneUpdateComputersShame on people not elogging! FrameFiles backups not working.On the one hand, SHAME
ON ALL PEOPLE WHO DON'T ELOG THINGS,
  
  3736   Mon Oct 18 17:16:30 2010 JenneUpdateSUSOld PRM, SRM stored, new PRM drag wiped[Jenne, Suresh]
We've put the old PRM and SRM (which
were living in a foil house on the cleanroom
  
  3741   Tue Oct 19 15:14:51 2010 JenneUpdateSUSPRM (little) update[Jenne, Suresh]
We've aligned the guiderod and wire
standoff to the PRM, each partly.  They
  
  3761   Fri Oct 22 15:06:43 2010 JenneUpdateSUSArts and Crafts!This afternoon I epoxied the guiderod and
wire standoff to the new PRM.  I also
epoxied the magnets that Suresh picked out
 StatusTable.png 
  3762   Fri Oct 22 16:59:21 2010 JenneUpdateElectronicsEpic TakeoverAs the suspension work winds down (we'll
be completely done once the ETMs arrive,
are suspended, and then are placed in the
  
  3777   Mon Oct 25 11:39:06 2010 JenneUpdateSUSMagnets glued to PRMThis morning I glued the magnets to the PRM.
 Now we wait, and tomorrow afternoon (at
the earliest), Suresh and I can balance the
 StatusTable.png 
  3786   Tue Oct 26 15:57:10 2010 JenneUpdateSUSOne magnet broken, reglued[Jenne, Suresh, Thanh (Bram's Grad Student)]
When we removed the grippers from
the magnets on the PRM, one of the face magnets
  
  3789   Tue Oct 26 21:27:02 2010 JenneUpdateCDSfixed OPLEV stuff and MCL filtersSince MC2_TRANS is, in fact, MC2 Transmission,
and not an oplev at all (it's not red, and
it's not a lever, although it does use a
  
  3790   Tue Oct 26 22:57:37 2010 JenneConfigurationComputersWhy doesn't DTT work?!?DTT has only SUS and "X02" channels
under C1 in the drop down channel selection
menu.  Basically, we can't measure any
  
  3824   Fri Oct 29 14:16:26 2010 JenneUpdateSUSPRM baking[Suresh, Jenne]
We took a look-see at the PRM after
the gluing from last night.  The balance
  
  3826   Fri Oct 29 16:39:01 2010 JenneUpdateTreasureOld Green suspension towers disassembled[Jenne, Joonho]
At Koji's request, we disassembled
2 of the old Green suspension towers that
 P1070014.JPGP1070015.JPG 
  3840   Mon Nov 1 17:27:47 2010 JenneUpdateSUSPRM ready for installation into chamber[Jenne, Suresh]
Over the weekend, Bob and Daphen
gave the PRM a 48hr. vacuum bake.  This
  
  3848   Tue Nov 2 16:49:02 2010 JenneConfigurationCamerasCabling on the PSL tableDear whomever setup the camera on the SW
corner of the PSL table,
It would be handy if, even for temporary
  
  3871   Fri Nov 5 19:33:18 2010 JenneUpdateElectronicsThe beginnings of the new phase of the RF workJoon Ho and I took a look at the RF stuff
that Alberto left, and we determined that
we've got most everything that we need. 
  
  3889   Thu Nov 11 01:34:27 2010 JenneUpdateSUSNew-Old ETM towers assembled[Suresh, Jenne]
We have put together the new-old
ETM towers.  These are the ones which
  
  3917   Sun Nov 14 16:40:46 2010 JenneUpdateTreasureActivities related to OSEM measurement[Valera, Jenne]
We pondered the idea of clamping
the PRM optic to measure the OSEM noise. 
  
  3925   Mon Nov 15 16:09:44 2010 JenneUpdateVACETMX, ETMY, ITMY chambers opened[Steve, Jenne, Suresh, Koji]
The remaining test mass chambers
have been opened, and have light doors in
  
  3942   Wed Nov 17 23:45:20 2010 JenneUpdateSUSA bad day for suspensions[Jenne, Suresh]
Today has been a downright miserable
day in the world of suspension work. Thumbs
 StatusTable.png 
  3956   Fri Nov 19 16:13:09 2010 JenneUpdateSUSETMU05: magnets glued to optic[Jenne, Suresh]
Suresh
and I glued the intact-from-the-first-round
 StatusTable.png 
  3966   Mon Nov 22 18:39:53 2010 JenneUpdateSUSETMU07: magnets glued to optic. ETMU05: magnets removed[Suresh, Jenne]
A
 StatusTable.png 
  3977   Tue Nov 23 14:52:28 2010 JenneUpdatePEMPEM Model StartedJoe showed me what was what with adding
DAQ channels, and I have begun building a simulink
  
  3979   Tue Nov 23 18:08:28 2010 JenneUpdateSUSETMU07: Balanced, standoff glued. ETMU05: Magnets glued to optic[Koji, Jenne]
ETMU07 had its wire winched to the
correct height, was balanced, standoff glued. 
 StatusTable.png 
  3984   Wed Nov 24 17:57:24 2010 JenneUpdateSUSETMU07: Baking. ETMU05: Needs side magnets reglued[Jenne, Koji]
We removed ETMU07 from the suspension
tower, after confirming that the balance
 StatusTable.png 
  3985   Wed Nov 24 18:11:26 2010 JenneUpdatePEMSome progress on getting PEM channelsI have made a little bit of progress on
the PEM channels.  I have begun writing
up detailed instructions in the
  
  4000   Tue Nov 30 18:15:52 2010 JenneUpdateSUSETMX ready to be installed. ETMY ready for winching[Jenne, Kiwamu]
We put ETMX back in its tower, and
confirmed its balance.  It might be
 StatusTable.png 
  4018   Mon Dec 6 23:33:15 2010 JenneUpdateSUSETMU05 winched, balanced, glued!!!!!![Suresh, Jenne]
 StatusTable.png 
  4034   Thu Dec 9 01:54:15 2010 JenneUpdateElectronicsSome Refl 11 fixesThe
Backstory:
Kevin was working on characterizing
  
  4043   Fri Dec 10 12:55:27 2010 JenneUpdateComputersBackup should be running successfully now[Joe, Jenne]
The nightly backup of the frames
and the /cvs/cds directories is back up and
  
  4047   Mon Dec 13 18:06:43 2010 JenneUpdateSUSETMY resuspended, ready to install. Tip Tilt realigned, ready to install.[Koji, Jenne]
I wish I could use a bigger font
for this, but, 
 StatusTable.png 
  4061   Wed Dec 15 18:29:59 2010 JenneUpdatePEMSeismometer Channels Being Recorded AgainThe Seismometer channels are once more
being recorded.  Alastair brought Gur1
back from the ATF the other day, and today
  
  4078   Mon Dec 20 22:56:20 2010 JenneUpdateIOOPlan for closing the vacuum chambersTuesday 

    If still everythig is
fine, put the BS heavy door.

-
  
  4079   Mon Dec 20 23:10:25 2010 JenneUpdateSUSPretty much ready for pump-down. A few final things....[Kiwamu, Jenne, Koji, Osamu]
We have mostly prepared the IFO for
pump down. 
  
  4103   Tue Jan 4 02:58:53 2011 JenneUpdateIOOPower into Mode Cleaner increasedWhat was the point:
I twiddled with several different
  
  4107   Tue Jan 4 18:37:18 2011 JenneUpdateIOOMCWFS alignedI undid Yuta's
temporary setup, and put beam back on both
  
  4116   Wed Jan 5 23:22:00 2011 JenneUpdateCamerasAligned the Xarm, no big deal[Kiwamu, Jenne]
We successfully aligned the X arm. 
No big deal.  Nothing to 
 DSC_2822.JPGKiwamuJenne_5Jan2011_Xarm_Aligned.png 
  4118   Wed Jan 5 23:45:33 2011 JenneUpdateCamerasAligned the Xarm, no big dealCorrect.  We can see the flashes clearly
on our new ETM camera, but we see absolutely
nothing on the ITM.
  
  4120   Thu Jan 6 00:06:01 2011 JenneUpdateIOOMagical absorbing PZT mirror[Kiwamu, Jenne]
We have a measely 465mW going into
  
  4123   Fri Jan 7 00:49:16 2011 JenneUpdateGreen LockingRecovered Xarm Green Lock, Preparation for Beat Note Measurement[Kiwamu, Jenne]
We went this evening in search of
a beat note signal between the Xarm transmitted
  
  4138   Tue Jan 11 18:41:43 2011 JenneUpdateIOOPut MC PZT offset onto MC board, instead of on awkward cart[Larisa and Jenne]
We wanted to get rid of the awkward
cart that was sitting behind the 1Y1 rack. 
 D040180-B.pdf 
  4148   Thu Jan 13 03:00:01 2011 JenneUpdateIOOWFS shenanigansMy goal
this afternoon was to
 D990249-B-1_MCWFS_schematic.pdf 
ELOG V3.1.3-