40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 4 of 337  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
ID Date Author Typeup Category Subject Text Attachments
  137   Wed Nov 28 21:51:52 2007 tobinConfigurationPSLISSI replaced the front-end differential receivers
for the ISS's "inner-loop" sensor and monitor
diode inputs with lower-noise [url=http://focus.ti.com/docs/prod/folders/print/ths4131.html]THS4131[/url]'s
  
  138   Thu Nov 29 10:36:47 2007 albertoConfigurationComputer Scripts / ProgramsAgilent 82357B GPIB to USB Interface Installation ProcedeureTo run the Agilent Automation-Ready CD provided
with the interface is only the first step
of the installation. Apparently there should
  
  140   Thu Nov 29 14:29:22 2007 tobinConfigurationComputerslinux1 httpd/conlogger fixedI think I fixed the [url=http://linux1/cgi-bin/conlog_web.pl]conlogger
web interface on linux1[/url].
  
  141   Thu Nov 29 15:17:53 2007 robConfigurationPSLISS
I put some ISS beam on the diode on the PSL
table.  In the previous layout, this was
  
  145   Fri Nov 30 11:44:57 2007 robConfigurationElectronicsETMX oplevIn the interests of getting the Xarm alignment
script working again, I reset the local damping
gains for the test masses to their previous
  
  146   Fri Nov 30 13:46:50 2007 robConfigurationElectronicsETMX oplev dead again[quote]In the interests of getting the Xarm
alignment script working again, I reset the
local damping gains for the test masses to
  
  147   Fri Nov 30 19:11:05 2007 ranaConfigurationElectronicsETMX oplev dead againI removed the ETMX HeNe and put in on a test
table and it fired up fine. In its
previous location the light on the HeNe power
  
  148   Fri Nov 30 19:29:14 2007 ranaConfigurationSUSnew screenAndrey is working on a new screen to show
us the drift of the optics by alarming on
their osem values. [COLOR=darkred]You can
  
  149   Fri Nov 30 19:46:58 2007 ranaConfigurationComputersEPICS Time Bad againThe time on the EPICS screens is off by 10
minutes again. Por Que?
  
  151   Fri Nov 30 20:17:26 2007 AndreyConfigurationPEMAccelerometers and alum.plates for themAll 6 accelerometers which were located near
the ITMX are turned off and disconnected
from the power cords.
 Scheme_Aluminum_Piece-inches.pdf 
  154   Sun Dec 2 21:02:12 2007 ranaConfigurationIOOMC SUS re-alignment[COLOR=purple][SIZE=2][B][FONT=Comic Sans
MS]The spot on MC2 was not centered, so I
put it back in the center:[/FONT][/B][/SIZE][/COLOR]
  
  155   Sun Dec 2 21:07:39 2007 ranaConfigurationIOOMC SUS re-alignment[COLOR=darkblue][CODE]you asked for:   diff
2007/12/01,4:58:48 2007/12/03,4:58:48 utc
'MC.*COMM'
  
  156   Sun Dec 2 21:13:16 2007 ranaConfigurationIOOMC SUS re-alignment   e.png 
  161   Mon Dec 3 19:44:58 2007 Accelerometers on new mountsConfigurationPEMAndrey
I (Andrey) continued today working with new
accelerometer mounting. (see entry #151 about
 DSC_0194.JPGDSC_0195.JPGDSC_0196.JPG 
  162   Mon Dec 3 22:20:09 2007 tobinConfigurationPSLISSI replaced the painfully short 1' cables on
the ISS photodiodes with luxurious five foot
cables, made by chopping a ten foot Amphenol
  
  172   Wed Dec 5 23:19:03 2007 AndreyConfigurationPEMAccelerometers are turned on
All accelerometers have been turned on, as
Alan asked during Wednesday meeting.
 7x 
  176   Thu Dec 6 19:19:47 2007 AndreyConfigurationSUSSuspension damping Gain was restored
Suspension damping gain was disabled for
some reason (all the indicators in the most
  
  186   Mon Dec 10 19:08:03 2007 tobinConfigurationPSLMZThe MZ seems finicky today--it keeps unlocking
and relocking.
  
  187   Mon Dec 10 20:35:59 2007 tobinConfigurationComputer Scripts / Programsautolocking scriptsI added this tidbit of csh code to the MZ
autolocker to prevent multiple copies from
running (on one computer):
  
  191   Thu Dec 13 23:56:02 2007 AndreyConfigurationComputer Scripts / ProgramsOvernight measurements
[COLOR=blue]After my disease[/COLOR] (fever,
vomitting, nose problem, overall weakness)
  
  194   Mon Dec 17 23:42:08 2007 AndreyConfigurationComputer Scripts / ProgramsOvernight measurements in X-arm
I am making overnight measurements this night
(from Monday to Tuesday) in XARM.
  
  198   Tue Dec 18 23:27:36 2007 AndreyConfigurationComputer Scripts / ProgramsNew overnight measurements (this night from Tue to Wed)
[COLOR=red]I am making overnight measurements
in XARM tonight.[/COLOR]
  
  211   Sat Dec 22 00:52:57 2007 tobinConfigurationPSLISS surgeryIn an attempt to quell oscillations in the
(unused) outer loop portion of the ISS, I
shorted the "PD+" and "PD-" signals from
  
  238   Mon Jan 14 23:11:26 2008 tobinConfigurationGeneralfiberJohn and I removed the fiber that ran from
the SP table to the cleanroom.  We plan to
build a MZ interferometer with this fiber
  
  243   Wed Jan 16 19:57:49 2008 tobinConfigurationPhotosISCT_EXHere's a photo of the ISCT_EX table, for the
purpose of planning our auxiliary laser arm
locking scheme.   Note the (undumped!) beam
 trx-annotated-small.jpg 
  250   Fri Jan 18 20:53:56 2008 tobinConfigurationGeneralETMY oplevI monkeyed around with the ETMY oplev, adding
a folding mirror and moving the HeNe so that
John, Sam, and I have more room for our auxiliary
  
  260   Thu Jan 24 20:03:40 2008 AndreyConfigurationSUSChanges to Dataviewer channels (XARM)
1) [COLOR=blue]Good news.[/COLOR] I added
a chanel "C1:SUS-ETMX_POS" to Dataviewer.
  
  261   Thu Jan 24 22:10:49 2008 AndreyConfigurationComputer Scripts / ProgramsProblem with channels - help of Rana, Robert or Steve is needed
I definitely spoiled something (changes some
settings) by chaotically clicking those blue
  
  263   Fri Jan 25 08:55:26 2008 robConfigurationGeneralChanges to Dataviewer channels (XARM)
As a general rule,
  
  265   Fri Jan 25 10:14:35 2008 robConfigurationSUSChanges to Dataviewer channels (XARM)[quote]
2) [COLOR=red]BAD NEWS.[/COLOR] While "clicking
the appropriate blue button" on the DAQ MEDM
  
  266   Fri Jan 25 11:38:16 2008 josephbConfigurationCamerasWorking GiGE video on Linux - sort of1)I have been able to compile the SampleViewer
program which can stream the video from the
Prosilica 750C camera.  This was accomplished
 snap.tiff 
  267   Fri Jan 25 13:36:13 2008 josephbConfigurationCamerasWorking GiGE video on MafaldaFinally got the GiGE camera sample viewer
video running on Mafalda by updating to the
latest API (version 1.16 from Dec 16, 2007)
  
  269   Fri Jan 25 17:11:07 2008 Max , AndreyConfigurationGeneralNEW_FETCH_SHOUROV and GET_DATA do not work
The problem which started yesterday after
Andrey's framebuilder restart still persists.
  
  281   Mon Jan 28 17:16:54 2008 AndreyConfigurationComputersMatlab libraries DO NOT WORK properly sometimes
Working in Matlab, I encountered at two different
times today the license distribution problem:
  
  288   Thu Jan 31 12:39:14 2008 JohnConfigurationGeneralY arm test mass camerasI've adjusted the test mass cameras on the
y arm to make the beam injected through ETMY
more visible.
  
  289   Thu Jan 31 16:53:41 2008 josephbConfigurationCamerasImproving camera user interfaceThere's a new and improved version of Snap
program at the moment people are free to
play with.
 Camera_exp_15000.tiffCamera_exp_3000.tiff 
  292   Fri Feb 1 15:04:54 2008 josephbConfigurationCamerasSnap with looping functionality availableNew GiGE camera code is available in /cvs/cds/caltech/target/Prosilica/40mCode/.
 Currently only runs on Mafalda.
  
  297   Tue Feb 5 15:32:29 2008 josephbConfigurationCamerasPMC and the GigE CameraThe PMC transmission video camera has been
removed and replaced with the GigE GC750
camera for the moment.
 pmc_trans.jpg 
  298   Tue Feb 5 17:39:05 2008 jweinerConfigurationPEMPEM-AS_MIC taken down from AS table, will put in PSL enclosure soonI took down the microphone that Andrey hung
above the AS table his first week in lab.
I want to hang the microphone above the PMC
  
  300   Wed Feb 6 16:50:47 2008 josephbConfigurationCamerasRegions of Interest and max frame rateThe Snap code has once again been modified
such that setting the -l option to 0 will
take images as fast as possible.  Also, the
  
  301   Wed Feb 6 19:39:11 2008 ranaConfigurationCamerasRegions of Interest and max frame rateWe really need to look into making the 40m
CDS network have an all GigE backbone so
that we can have cooler cameras as well as
  
  303   Fri Feb 8 17:55:53 2008 joshConfigurationPEMPEM-AS_MIC now in PSL enclosureI have moved the microphone to the PSL enclosure,
hanging near the south (Y) side from a support
rod for the overhanging storage area so that
  
  307   Sun Feb 10 21:43:16 2008 robConfigurationIOOMC alignment tweaked
I adjusted the alignment of the free hanging
mode cleaner to best transmit the PSL beam.
  
  309   Mon Feb 11 22:44:29 2008 robConfigurationDAQChange in channel trending on C1SUS2
I removed the MC2 optical lever related channels
from trends, and the SRM POUT and YOUT (as
 srm_sync.png 
  311   Tue Feb 12 16:18:29 2008 robConfigurationComputer Scripts / Programsautoburt cron moved to op340m
I moved the autoburt cron job from op440m
to op340m.  For some reason, [B]burtrb[/B]
  
  345   Thu Feb 28 16:19:37 2008 josephbConfigurationComputersMafalda rewired and multiple cameras running1) Mafalda is now connected via an orange
Cat5E ethernet cord to the gigabit ethernet
switch in rack in the office space.    It
  
  346   Thu Feb 28 19:37:41 2008 robConfigurationComputersmultiple cameras running and seisBLRMS[quote]1) Mafalda is now connected via an
orange Cat5E ethernet cord to the gigabit
ethernet switch in rack in the office space.
  
  356   Tue Mar 4 19:14:09 2008 ranaConfigurationCDSTDS & SVN[COLOR=purple][I]Matt, Rob, Rana[/I][/COLOR]

[B][COLOR=chocolate]Today we added the TDS
  
  357   Tue Mar 4 20:14:02 2008 ranaConfigurationIOOMC AlignmentThe MC alignment was pretty far off. We were
getting TEM01 mode locks only. 
Rather than inspect what happened I just
  
  363   Fri Mar 7 00:47:54 2008 ranaConfigurationPEMRanger SS-1Yesterday evening around 7:30 PM, I changed
the Ranger seismometer from a 
vertical to a horizontal seismometer. To
 ss1.pdf 
ELOG V3.1.3-