Entry  Tue Mar 25 13:21:25 2008, Andrey, Update, Computers, c1susvme2 is not behaving itself again 
 
Entry  Tue Mar 25 15:56:09 2008, John, Update, Treasure, Assorted pictures D40.pdf
Some pictures scavenged from the D40.
    Reply  Tue Mar 25 16:34:47 2008, rob, Update, Computers, c1susvme2 
[quote][quote]c1susvme2 isn't behaving itself. It keeps getting out of sync and/or giving a red status light.

After going through the usual restart procedures a few times (unsuccessfully) we power cycled the c1susvme & c1sosvme crates. We think everything came
Entry  Wed Mar 26 22:26:15 2008, John, Update, Computers, c1susvme 
I removed the fan and tweaked the timing cables to see if they were the source of our problems. I saw no effect. I'm leaving the fan off for the moment
to see if that helps. It is on top of the filing cabinet next to my desk.
Entry  Fri Mar 28 16:18:18 2008, rob, Update, Computers, c1susvme2 status 
c1susvme2 is getting worse and worse.  it won't run for more than ~45 minutes without fatally de-syncing.  for now I've turned off c1iovme (which sends
the MCL signal) to see if that's causing the problem.  next I'll swap the boards for c1susvme1 and c1susvme2 to see if it's the cpu (or maybe the RFM card)
itself, rather than the timing/pentek systems.
    Reply  Mon Mar 31 14:14:16 2008, rob, Update, Computers, c1susvme2 status 
[quote]c1susvme2 is getting worse and worse.  it won't run for more than ~45 minutes without fatally de-syncing.  for now I've turned off c1iovme (which
sends the MCL signal) to see if that's causing the problem.  next I'll swap the boards for c1susvme1 and c1susvme2 to see if it's the cpu (or maybe the
RFM card) itself, rather than the timing/pentek systems.[/quote]
Entry  Wed Apr 2 15:03:51 2008, steve, Update, General, reflectivity of black glass  bg12refl.pdfbg12refsetup.pdf
The reflectivity of black glass, shade 12 was supplied by Donald O'Shea
of Emerald Glass Inc., Westlake, OH 44145
Entry  Mon Apr 7 16:42:56 2008, rana, Update, Computers, eLog intermittent 
Phil Ehrens restarted Dziban again this morning. Looks like its still crashing each Monday around 8 AM.

Here is the latest suspect:
Entry  Mon Apr 7 18:58:49 2008, steve, Update, General, reflectivity of SS304 ss304s8refl.pdf
The reflectivity of stainless steel 304 super polished # 8 was measured the same way as elog entry 409

The reflectivity: 74 +- 1 % from incident angle 10 to 80 degrees
    Reply  Wed Apr 16 10:20:01 2008, Andrey, Update, Computers, Rosalba and linux3 
[quote]There is a new computer in the control room -- its called [B][COLOR=purple]Rosalba[/COLOR][/B],
in keeping with our naming convention. Its a quad-core machine that
Dmass found for cheap somewhere; we've installed the CentOS on it
Entry  Thu Apr 17 15:00:59 2008, steve, Update, VAC, vac controller computer to be replaced 
Now that Rosalba is up and running someone should step forward to volunteer for this job.

Old desk top at the Vacuum Rack should be replaced by a functional less old computer so
Entry  Thu Apr 17 20:17:37 2008, Andrey, Update, PEM, Two issues with our weather station 

I encountered two difficulties working with the "Weather Station".
Entry  Fri Apr 18 16:02:58 2008, alex, Update, SUS, end station sus front-end bug fix 
installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables.
    Reply  Fri Apr 18 16:27:04 2008, rob, Update, SUS, end station sus front-end bug fix 
[quote]installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables.[/quote]

But where is the code?
Entry  Fri Apr 18 16:48:13 2008, Andrey, Update, PEM, Rain collector of weather station DSC_0520--before.JPGDSC_0537--after.JPG

Today the rain collector of our weather station was cleaned. As a result, we checked that the rain indication on the weather monitor and on the MEDM screens
is alive and working properly. I am adding some details about the roof sensors to the wiki-40 page about the weather station. See especially the link "More
Entry  Fri Apr 18 19:46:08 2008, rana, Update, ASS, check adaptive 0052_xray_thm45.jpg
I restarted the adaptive code today using 'startass' and 'upass'. 
I moved them into the scripts/ASS/ subdirectory.
Entry  Sun Apr 20 20:29:46 2008, rana, Update, Computer Scripts / Programs, tdsread bugs 
[COLOR=darkred]There seems to be a problem with reading the C1:IOO-MASTER_OVERFLOW field 
when it is read in as part of an array. The only way for me to describe it
is to just attach the terminal output in this entry...this is mainly [B]for
    Reply  Mon Apr 21 12:58:42 2008, rob, Update, ASS, check adaptive 
[quote]

Caryn Palatchi (a Caltech undergrad who just started working with us)
    Reply  Mon Apr 21 13:12:21 2008, rob, Update, Computer Scripts / Programs, tdsread bugs 
[quote][COLOR=darkred]There seems to be a problem with reading the C1:IOO-MASTER_OVERFLOW field 
when it is read in as part of an array. The only way for me to describe it
is to just attach the terminal output in this entry...this is mainly [B]for
    Reply  Tue Apr 22 10:59:24 2008, rob, Update, SUS, MC1 electronics busted 
[quote]I spent some time trying to fix the utter programming fiasco which was our MCWFS diagonalization script.

However, it still didn't work. Loops unstable. Using the matrix in the screen snapshot is OK, however.
    Reply  Tue Apr 22 16:17:48 2008, rob, Update, SUS, end station sus front-end bug fix 
[quote]installed and started new susEtmx.o and susEtmy.o to fix a problem with ETMY optical lever variables.[/quote]

What Alex means is that the EPICS values for the ETMY optical levers were being clobbered in the RFM.  The calculations were being done correctly in the
Entry  Tue Apr 22 17:08:04 2008, Caryn, Update, IOO, no signal for C1:IOO-MC_L  
C1:IOO-MC_L signal was at zero for the past few days
Entry  Thu Apr 24 14:10:26 2008, rob, Update, Locking, locking work 
[I]Rob, Johnnie[/I]

We made some progress on locking last night (Wed night), namely that we were able to handoff (briefly) the CARM-MCL path the REFL-DC error signal.  We
Entry  Thu Apr 24 23:27:48 2008, rana, Update, PEM, acoustic noise in MC_F 
I looked at the [COLOR=darkblue][FONT=Comic Sans MS][SIZE=3]coherence between the Microphone in the PSL (PEM-AS_MIC) and the MC_F[/SIZE][/FONT][/COLOR]
channel.
Entry  Thu Apr 24 23:50:10 2008, rana, Update, General, Syringes in George the Freezer 
There are some packets of syringes in the freezer which are labeled as belonging to an S. Waldman.
Thu Apr 24 23:48:55 2008 
Entry  Fri Apr 25 13:20:04 2008, Andrey, Update, PEM, Microphone test Microphone.png
In response to Rana's request, I tested the microphone (if it is alive or not) by clapping my hands and speaking aloud nearby.

The microphone is alive, see the attached "Full Data" for 5 minutes from Dataviewer.
Entry  Fri Apr 25 15:44:21 2008, steve, Update, PSL, scattering measurments 6x
In pursuit of a low back scattering, high power beam dump we looked at materials such:
polished copper, polished aluminum, diamond cut aluminum, variety of polished & heat treated stainless steel and shades of black glasses.
Black glass is ideal at low power. Superpolished SS 304 #8 is the only material that measures close to bg
Entry  Mon Apr 28 23:44:33 2008, Andrey, Update, Computer Scripts / Programs, Weather.db 

I was trying to figure out how to modify the file "Weather.db" so that the atm.pressure would be recalculated from Pa to bar before appearing in the EPICS
screen, but so far I did not succeed. [COLOR=blue]I restarted processor "c1pem1" several times.[/COLOR] I will continue this tomorrow, and also I will
Entry  Tue Apr 29 21:30:49 2008, Andrey, Update, PEM, In the process of renaming channels for Weather Station 

I startted renaming channels for the weather station, and I will continue this tomorrow, on Wednesday.
Entry  Thu May 1 08:31:51 2008, steve, Update, SUS, earthquake trips etmy & mc1 
Earthquake at Lake Isabel magnitude 4.4 at 1am today shakes the 40m
ETMY and MC1 watchdogs tripped.
Sus damping restored.
Entry  Mon May 5 15:53:14 2008, steve, Update, VAC, drypump replaced & readbacks are out 
The small turbo pump of the annulus system is tp3
It's drypump was replaced at 1.4 Torr after 8 months of operation.
The rebuilding cost of this SH100 drypump is getting ridiculously high $1349.
Entry  Fri May 9 08:40:24 2008, steve, Update, SUS, ETMY sus damping restored 
ETMY lost damping at 19:10 last night.
There was no seismic event than.
Sus damping was restored this morning. 
Entry  Fri May 9 10:15:36 2008, josephb, Update, Computers, Nodus has moved 
Steve and myself moved Nodus from under the table in the control room, to just above the Rana computer in the control room rack.
Entry  Tue May 13 10:15:52 2008, steve, Update, SUS, restored damping of BS & PRM 
I think our janitor was cleaning too heavy handedly.
The BS and PRM sus damping were lost.
They were restored.
Entry  Tue May 13 10:38:28 2008, steve, Update, Computers, rfm network is down 
The RFM network went down yesterday around 5pm
Only c1susvme1 is alive but it's timing is off.
Andrey is bringing the network up.
Entry  Wed May 14 14:05:40 2008, Andrey, Update, Computers, Computer Linux-2, MEDM screen "Watchdogs" 

Computer "Linux-2", MEDM screen "C1SUS_Watchdogs.adl": there is no indication for ETMY watchdogs, everything is white. There is information on that screen
"C1SUS_Watchdogs.adl" about all other systems (MC, ETMX,...), but something is wrong with indicators for ETMY on that particular control computer.
Entry  Mon May 19 11:49:57 2008, steve, Update, SUS, etmy oplev laser replaced 
The 9 years old Uniphase HeNe was replaced by a new JDSU 1103P
Power output ~3.5 mW, reflected light back on qpd ~140 microW, 12,800 counts
Andrey will get the ~2.5 mm od spot on the qpd smaller by replacing
Entry  Wed May 21 15:21:33 2008, rob, Update, Computer Scripts / Programs, autolockers and cron 

I added hourly cron jobs to op340m to ensure that 
Entry  Sun May 25 19:33:16 2008, rana, Update, IOO, MC Bad after Re-alignment e.pdfpmc.png
The MC pointing was off and the transmitted power was down after John and Andrey brought it back after the bootfest.

I tried getting it back on Friday but was unsuccessful. Today, after the Phoenix Landing, I got it back to someplace
Entry  Sun May 25 22:33:00 2008, rana, Update, SUS, ETMY Oplev Work 
I found the ETMY table in disarray and put the panels back on and put the ETMY OL laser back on the quad.

The next thing to do is clean up the table (there's a lot of junk on it) and then put in a lens within
Entry  Wed May 28 14:19:47 2008, steve, Update, PSL, kaleidoscope of psl pslscat.pngpslscat2.png2GigEs.pngperwash.pngetmydisarray.png
atm 1: scattering psl table optics from the top of the output periscope f4, 60s @MOPA 3 W
atm 2: scattering psl table optics from the top of the output periscope f4, 20s
atm 3: competing GigE cameras on the north end of psl table
Entry  Thu May 29 16:32:09 2008, steve, Update, SUS, etmy oplev is back P1020417.pngP1020420.png
I relayed the optics for ETMY-oplev as shown in pictures below.
The reflected beam goes directly to the qpd
    Reply  Fri May 30 12:37:45 2008, rob, Update, SUS, etmy oplev is back 
[quote]I relayed the optics for ETMY-oplev as shown in pictures below.
The reflected beam goes directly to the qpd[/quote]
Entry  Tue Jun 3 12:33:36 2008, Andrey, Update, Cameras, Andrey, Josephb 

Continuing our work with cameras,
Entry  Wed Jun 4 10:18:52 2008, steve, Update, PSL, wedged SS beam trap trap1.pngtrap2.png
I moved the SS trap over to the psl table.
Texas super # 8 was used from the large shipment.
TXs#8 scattering measured as before, meaning the polishing is good.
Entry  Fri Jun 6 16:10:51 2008, steve, Update, PSL, HEPA filters are running at 100% 
The psl HEPA filters were turned up to run at 100% to accommodate beam trap work on Tuesday, June 3, 2008
Entry  Tue Jun 10 08:37:18 2008, steve, Update, PSL, beam trap is being tested trapss3w.png
High power beam trap is being tested just west of FSS area on psl enclosure.

When the pmc is operating at low power that means that the rest of the 3W is going into the 
Entry  Wed Jun 11 11:45:25 2008, steve, Update, PSL, ss trap works P1020534.pngP1020533.png
The trap works well at 3 W level.  No back reflected beam coming out of the trap on low power
sensing card level. The back scattering was not measured. The trap is insensitive to small pointing variations. 
The SS surface did not show any visible degradation after 16 hrs of 3w exposure at elliptical beam size  4x8 mm 
Entry  Thu Jun 12 01:51:23 2008, rob, Update, Locking, report lock_control_sequence.png
[I]rob, john[/I]

We've been working (nights) on getting the IFO locked this week.  There's been fairly steady incremental progress each night, and tonight we managed to
    Reply  Thu Jun 12 15:09:33 2008, alan, Update, Locking, report 
Rob: Awesome figure. As you can imagine, I have lots of questions, and hope that you will consider this figure to be the beginning, leading to ever-more
detailed versions. But for now, I just want to ask whether you understand *what* is twitchy, and what the twitchiness does to prevent you from taking this