40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 48 of 344  Not logged in ELOG logo
Entry  Wed Oct 6 14:49:54 2010, rana, Summary, lore, Steve on the sea jacques.jpg
Entry  Sun Oct 10 18:09:02 2010, Koji, Summary, COC, Phase map interferometer calibration for the data on Oct 8th, 2010  calibration.pdf
Entry  Sun Oct 10 18:28:25 2010, kiwamu, Summary, SUS, ITMX OSEM offsets OSEM.png
Entry  Mon Oct 11 16:09:10 2010, yuta, Summary, SUS, current OSEM outputs 
Entry  Mon Oct 11 23:55:25 2010, Joonho Lee, Summary, Electronics, CCD cables for output signal 
Entry  Mon Oct 18 18:33:46 2010, Koji, Summary, COC, Summary of the main mirrors & their phasemap measurement 
Entry  Mon Oct 18 22:11:32 2010, Joonho Lee, Summary, Electronics, CCD cables for input signal 
Entry  Thu Oct 21 01:11:48 2010, rana, Summary, Computers, elog change and rossa tex 
    Reply  Thu Oct 21 13:05:19 2010, Koji, Summary, Computers, elog change and rossa tex 
Entry  Fri Oct 22 19:53:27 2010, yuta, Summary, CDS, conversion failure in digital filters 
Entry  Sat Oct 23 14:42:01 2010, yuta, Summary, CDS, damped MC suspensions dam.png
    Reply  Sun Oct 24 18:06:35 2010, kiwamu, Summary, Locking, setup for green beat green_beat_note.png
    Reply  Mon Oct 25 02:14:38 2010, Koji, Summary, Locking, setup for green beat 
Entry  Thu Oct 28 23:17:15 2010, yuta, Summary, CDS, [EMERGENCY] accidentally deleted daqd 
Entry  Fri Oct 29 01:18:03 2010, Koji, Summary, SUS, PRM standoff glued IMG_3674.jpg
    Reply  Fri Oct 29 11:25:15 2010, josephb, yuta, Summary, CDS, [EMERGENCY] accidentally deleted daqd 
Entry  Fri Oct 29 18:37:33 2010, yuta, Summary, CDS, daqd and current CDS status 06-25-2009.NN_24ThreatLevel.GJH2L69BK.1.jpg
Entry  Sat Oct 30 05:27:53 2010, yuta, Summary, CDS, CDS time delay measurement delaysetup.pngCDSdelay.png
    Reply  Sat Oct 30 14:35:43 2010, Koji, Summary, CDS, CDS time delay measurement CDS_system_investigation_090323.pdf
Entry  Sun Oct 31 00:19:35 2010, rana, Summary, Computer Scripts / Programs, HP3563A netGPIB function 
    Reply  Mon Nov 1 15:47:15 2010, yuta, Summary, CDS, CDS time delay measurement downupsampling.pngCDSdelay2.png
    Reply  Mon Nov 1 16:43:24 2010, Koji, Summary, CDS, CDS time delay measurement 
Entry  Mon Nov 1 19:32:08 2010, yuta, Summary, CDS, fb crashed? during c1ioo and c1mcs connection at ASC 
Entry  Wed Nov 3 02:23:11 2010, yuta, Summary, CDS, checking whitening filter board MC3SEN.png
Entry  Wed Nov 3 02:37:39 2010, yuta, Summary, Green Locking, coarse locked green beat frequency Screenshot_LowFreqLock.png
    Reply  Wed Nov 3 03:00:47 2010, Koji, Summary, Green Locking, coarse locked green beat frequency 
    Reply  Wed Nov 3 09:32:00 2010, rana, Summary, CDS, Eurocard board swapping 
Entry  Wed Nov 3 17:01:01 2010, josephb, Summary, CDS, Comparison of RFM read times  
Entry  Fri Nov 5 15:20:18 2010, josephb, alex, Summary, CDS, 40m computer slow down solved 
    Reply  Fri Nov 5 21:49:12 2010, rana, Summary, CDS, 40m computer slow down solved 
Entry  Sat Nov 6 01:54:15 2010, Frank, Summary, Computers, virus definition file update on laptop for dinocam 
Entry  Sat Nov 6 07:26:54 2010, yuta, Summary, IOO, reduced common mode displacement of the beam through MC1 to MC3 A2LMCalign.png
    Reply  Sat Nov 6 16:13:14 2010, rana, Summary, CDS, 40m computer slow down solved 
    Reply  Tue Nov 9 05:40:12 2010, yuta, Summary, IOO, MC aligning going on MCalignNov9.png
    Reply  Wed Nov 10 02:51:35 2010, yuta, Summary, IOO, limitation of current MC aligning MCalignNov9.png
    Reply  Wed Nov 10 11:46:19 2010, Koji, Summary, IOO, limitation of current MC aligning 
    Reply  Wed Nov 10 12:21:18 2010, yuta, Summary, IOO, limitation of current MC aligning 
    Reply  Wed Nov 10 14:28:33 2010, Koji, Summary, IOO, limitation of current MC aligning 
Entry  Thu Nov 11 04:32:53 2010, yuta, Summary, CDS, found poor contact of DAC cable, previous A2L results were wrong 
Entry  Thu Nov 11 05:56:04 2010, yuta, Summary, IOO, setting up temporary oplev for coil balancing of MCs MC2coils.png
    Reply  Thu Nov 11 11:51:30 2010, Koji, Summary, CDS, found poor contact of DAC cable, previous A2L results were wrong 
    Reply  Thu Nov 11 23:35:23 2010, Koji, Summary, CDS, found poor contact of DAC cable, previous A2L results were wrong IMG_3698.jpgbad-boys.pngIMG_3705.jpgIMG_3706.jpg
Entry  Mon Nov 15 15:02:00 2010, Koji, Summary, PSL, power measurements around the PMC 
Entry  Wed Nov 17 20:44:59 2010, yuta, Summary, CDS, no QPD channels on c1sus machine today 
Entry  Thu Nov 18 16:32:21 2010, yuta, Summary, CDS, current damping status for all optics c1sus handles c1susdampings.png
Entry  Thu Nov 18 17:42:20 2010, Joonho Lee, Summary, Electronics, CCD cables. Upgrade_plan_(Nov18).pdf
    Reply  Sat Nov 20 03:37:11 2010, yuta, Summary, CDS, CDS time delay measurement - the ripple c1tst16Kdelay.png
Entry  Mon Nov 22 13:16:52 2010, josephb, Summary, CDS, CDS Plan for the week 
Entry  Tue Nov 23 11:32:03 2010, Joonho, Summary, Electronics, RF distribution unit. Frequency_Distribution_Unit_Arrangement.jpg
Entry  Tue Nov 23 23:13:40 2010, kiwamu, Summary, CDS, plan: we will install C1LSC 
ELOG V3.1.3-