40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 46 of 339  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  14809   Thu Jul 25 00:26:47 2019 MilindUpdateCamerasConvolutional neural networks for beam trackingSomehow I never got around to doing the
pixel sum thing for the new real data from
the GigE. Since I have to do it for the presentation,
 centroid.pdfsubplot_yaw_test.pdf 
  14808   Wed Jul 24 20:23:52 2019 gautamUpdateCamerasUpgraded Pylon from 5.0.12 to 5.2.0Since there are multiple SURF projects
that rely on the cameras:


I moved the new installs
  
  14807   Wed Jul 24 20:05:47 2019 MilindUpdateCamerasCNNs for beam tracking || Tales of desperationAt the lab meeting today, Rana suggested
that I use the Pylon app to collect more
data if that's what I need. Following
 saturation_percentage.pdf 
  14806   Wed Jul 24 16:45:32 2019 JonUpdateCamerasUpgraded Pylon from 5.0.12 to 5.2.0I upgraded Pylon, the C/C++ API for the
GigE cameras, to the latest release, 5.2.0.
It is installed in the same location as before,
 IMG_3525.jpg 
  14805   Wed Jul 24 12:24:43 2019 MilindUpdateIOOunstick.py and ifotestMoved the unstick.py code to the ifotest
repository here.
It now handles signals like those generated
  
  14804   Wed Jul 24 04:20:35 2019 KruthiUpdateCalibration-RepairMC2 pitch and yaw calibrationSummary:  I calibrated MC2
pitch and yaw offsets to spot position in
mm. Here's what I did:
 Pitchyaw_calibration.png 
  14803   Wed Jul 24 02:06:05 2019 KruthiUpdateCamerasHDR imagesI have been trying a couple of HDR algorithms,
all of them seem to give very different results.
I don't know how suitable these algorithms
 6x 
  14802   Wed Jul 24 00:22:24 2019 gautamUpdateALSPSL frequency locked to XARM length using ALSSummary:

I succeeded in locking the PSL
frequency to the XARM cavity length, with
 ALS_X_noise_POX.pdfBR_comparison.pdfALS_CARM_OLG.pdf 
  14801   Tue Jul 23 21:59:08 2019 JonUpdateCamerasPlan for GigE camerasThis afternoon Gautam and I assessed what
to do about restoring the GigE camera software.
Here's what I propose:
  
  14800   Mon Jul 22 23:53:16 2019 gautamUpdateALSIR ALS locking attemptSummary:

My goal tonight was to lock the
PSL frequency to be resonant in the
 ALS_X_outOfLoopnoise.pdfALS_X_inLoopnoise.pdfCARM_loopShape.pdf 
  14799   Mon Jul 22 21:04:40 2019 ranaUpdateComputersmaking rossa great again
copied over /etc/fstab lines from
pianosa sothat the NFS mounts work correctly
added
symlinks so that the NFS dirs mount in the
 seis.pdf 
  14798   Mon Jul 22 13:32:55 2019 KruthiUpdateSUSTest mass pitch adjustment test[Kruthi, Milind]

On Friday, Milind and I performed
the pitch adjustment test Rana had asked
 6x 
  14797   Mon Jul 22 13:26:41 2019 KruthiUpdateIOOMC lockedThe MC2 has 2
GigE cameras right now. I'll
put back the analog asap.
  
  14796   Mon Jul 22 12:57:35 2019 KruthiUpdateLoss MeasurementMC2 loss mapIn my script I have used "CAM-ETMX_SNAP"
only; while entering it in the elog
I made a mistake, my bad!
  
  14795   Mon Jul 22 07:21:13 2019 gautamUpdateCDSpainosa messed withSomebody changed the settings on painosa
without elogging anything about it. Why does
this keep happening? I thought the point
  
  14794   Sun Jul 21 22:16:34 2019 ranaUpdateGeneralrossa Xdisp bricked"bricked" is to mean that it
has the functionality of a brick and can
be tossed. But rossa seems to have just gotten
  
  14793   Sun Jul 21 20:23:35 2019 ranaUpdateIOOMC lockedI found the MC2 face camera disabled(?)
and the MC servo board input turned off.
I turned the MC locking back on but I don't
  
  14792   Sun Jul 21 19:27:25 2019 MilindUpdateLoss MeasurementMC2 loss mapI think ezca.Ezca().write() takes the string
"CAM-ETMX_SNAP" as an argument
and not C1:CAM-ETMX_SNAP. See this,
  
  14791   Sun Jul 21 17:17:03 2019 KruthiUpdateLoss MeasurementMC2 loss mapThe camera server keeps throwing the error:
failed to grab frames. Milind suggested that
it might a problem with the ethernet cable,
  
  14790   Sun Jul 21 12:55:38 2019 gautamUpdateCDSCM board Latch Enable test scriptDATED, SEE   LatchLogic.pdfLatchLogicTest.png 
  14789   Sun Jul 21 12:54:18 2019 gautamUpdateLoss MeasurementMC2 loss mapCan you please be more specific about what
the error is? Is this the usual instability
with the camera server code? Or was it something
  
  14788   Sun Jul 21 02:07:04 2019 KruthiUpdateLoss MeasurementMC2 loss mapI'm running the MC2 loss map scripts
on pianosa now. The camera server is throwing
an error and is not grabbing snapshots :(
  
  14787   Sat Jul 20 14:43:45 2019 MilindUpdateCamerasCNNs for beam tracking || Analysis of results<Adding details>

See Attachment #2.

 frame0.pdfsubplot_yaw_test.pdfintensity_histogram.mp4network2.pdf 
  14786   Sat Jul 20 12:16:39 2019 gautamUpdateCamerasCNNs for beam tracking || Analysis of results
Make the MSE a subplot on the same
axes as the time series for easier interpretation.
Describe
the training dataset - what is the pk-to-pk
  
  14785   Sat Jul 20 11:57:39 2019 gautamSummaryCDSP2 interface boardThe boards arrived. I soldered on a DIN96
connector, and tested that the goemetry will
work. It does 
 IMG_7773.JPG 
  14784   Sat Jul 20 11:24:04 2019 gautamUpdateGeneralrossa brickedSummary:

SnapPy
  
  14783   Sat Jul 20 01:03:37 2019 gautamUpdate Dataviewer errorWhat channels are you trying to read?




  
  14782   Fri Jul 19 22:48:08 2019 KruthiUpdate Dataviewer errorI'm not able to get trends of
the TM adjustment test that Rana had
asked us to perform, from the dataviewer.
  
  14781   Fri Jul 19 19:44:03 2019 gautamUpdateCDSDatabase file testSummary:

The database files for C1ISCAUX
seem to work file - the exception being the
 Whitening.png 
  14780   Fri Jul 19 17:42:58 2019 gautamUpdateGeneralrossa Xdisp brickedFor some reason, rossa's Xdisplay won't
start up anymore. This happened right after
the UPS reset. Koji and I tried ~1.5 hours
  
  14779   Fri Jul 19 16:47:06 2019 MilindUpdateCamerasCNNs for beam tracking || Analysis of resultsI did a whole lot of hyperparameter tuning
for convolutional networks (without 3d convolution).
Of the results I obtained, I am attaching
 7x 
  14778   Fri Jul 19 15:54:47 2019 gautamUpdateGeneralControl room UPS Batteries need replacementThe control room UPS started making a beeping
noise saying batteries need replacement.
I hit the "Test" button and the
  
  14777   Fri Jul 19 15:51:55 2019 gautamUpdateGeneralProjector lightbulb blown out[chub, gautam]

Bulb replaced. Projector is back
on.
  
  14776   Fri Jul 19 12:50:10 2019 gautamUpdateSUSDC bias actuation options for SOSRana and I talked about some (genius)
options for the large range DC bias actuation
 heaterPitch_2018.pdfScreenshot_from_2019-07-19_16-39-21.png 
  14775   Thu Jul 18 22:34:40 2019 KojiSummaryCDSiscaux electronics modificationsThe whitening filter modules have been
restored to the crates. The SMA cables have
been restored and fastened by a spanner.
  
  14774   Thu Jul 18 22:03:00 2019 KruthiUpdateCamerasMC2 and cameras[Kruthi, Yehonathan, Gautam]

Today evening, Yehonathan and I
aligned the MC2 cameras. As of now there
  
  14773   Thu Jul 18 19:58:56 2019 gautamUpdateCDSWork on Acromag chassisNow that the .db files were prepared, I
wanted to test for errors. So I did the following:


Acromags were mounted on
 IMG_7771.JPGIMG_7770.JPGIMG_7772.JPG 
  14771   Thu Jul 18 10:46:04 2019 gautamUpdateCDSDatabase files madeI completed the translation of the .db
files for the EPICS database records from
the VME notation to the Acromag/Modbus/Asyn
  
  14770   Thu Jul 18 00:51:52 2019 KojiSummaryCDSiscaux electronics modificationsAlong with the plan in ELOG
14744, the ISC PD interface and the whitening
filter board have been modificed. The ISC
 LSC_whitening2.jpgLSC_whitening.jpg 
  14769   Wed Jul 17 21:22:41 2019 gautamUpdateCDSCM board Latch Enable subtlety[koji, gautam]

Koji pointed out an important subtlety
pertaining to the "LATCH ENABLE"
  
  14768   Wed Jul 17 20:12:26 2019 KruthiUpdateCamerasAnother GigE in place of analog cameraI've taken the MC2 analog  zoomed_out_gige.pngosems_mc2.pngMC2.pdf 
  14767   Wed Jul 17 17:56:18 2019 KojiConfigurationComputersGave resolv.conf to giadaKruthi noticed that she could not login
to rossa from giada.

I checked /etc/resolv.conf and
  
  14766   Wed Jul 17 03:05:01 2019 KruthiUpdateASSMC spot position measurement scripts[Kruthi, Gautam, Rana]

Gautam installed Atom text editor on Pianosa
yesterday.
  
  14765   Tue Jul 16 16:00:01 2019 gautamUpdateCDSc1iscaux Supermicro setupI worked on preparing for the c1iscaux
upgrade a bit today.


 IMG_7769.JPG 
  14764   Tue Jul 16 15:17:57 2019 KojiHowToCDSFinal bit bug of the BIO CDS module Yutaro talked about the BIO bug in KAGRA
elog. http://klog.icrr.u-tokyo.ac.jp/osl/?r=9536

I think I made the similar change
  
  14763   Tue Jul 16 15:00:03 2019 gautamUpdateSUSMultiple small EQsThere were several small/medium
earthquakes in Ridgecrest and one medium
  
  14762   Mon Jul 15 18:55:05 2019 gautamUpdateIOOMegatron hard-rebooted[koji, gautam]

In addition to c1psl needing a
reboot, megatron was un-ssh-able (although
  
  14761   Mon Jul 15 14:53:40 2019 MilindUpdateIOOkeyed psl crate, unstick.pyMode cleaner was not locked today. Koji
came in and concluded that PSL had died.
So we keyed it. Then we ran my unstick.py
  
  14760   Mon Jul 15 14:09:07 2019 MilindUpdateCamerasCNN LSTM for beam trackingI've set up network with a CNN encoder
(front end) feeding into a single LSTM cell
followed by the output layer (see attachment
 cnn-lstm.pngfft_yaw.pdfyaw_motion.pdf 
  14759   Mon Jul 15 03:30:47 2019 KruthiUpdateCalibration-RepairWhite paper as a Lambertian scattererI made some rough measurements, using the
setup I had used for CCD calibration, to
get an idea of how good of a Lambertian scatterer
 BRDF_paper.png 
ELOG V3.1.3-