40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 46 of 344  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  2406   Sun Dec 13 20:50:45 2009 ranaSummaryIOOMach Zender CalibrationI ramped the MZ PZT (with the loop disabled
on the input switch) to calibrate it. Since
the transmission has been blocked, I used
 Untitled.png 
  2407   Sun Dec 13 23:18:09 2009 ranaSummaryIOODisplacement noise on the PSL tableFor the Laser Gyro, I wondered how much
mechanical noise we might get with a non-suspended
cavity. My guess is that the PMC is better
 mz.pdf 
  2436   Mon Dec 21 01:14:08 2009 ranaSummaryElectronicsNoise measurement of the Rai Weiss FET preamp box I shorted the input to the box and
then put its output into the SR560 (low noise,
G = 100, AC). I put the output of the SR560
 IMG_0242.JPGPicture_2.pngRWnoise.png 
  2452   Sat Dec 26 19:22:13 2009 KojiSummaryGeneralMode coupling of two astigmatic beamsIn this note, amplitude and power couplings
of two astigmatic (0,0)-th order gaussian
modes are calculated.
 mode_coupling.pdf 
  2499   Sun Jan 10 23:22:56 2010 JenneSummaryGeneralScattering Measurements of 35W Beam DumpsOn Friday, Rana and I measured the scatter coming from  P1090014_copy.JPGScatterometerSetup.png 
  2507   Tue Jan 12 09:14:52 2010 steveSummaryGeneralScattering Measurements of 35W Beam Dumps 
 What was the power level, polarization
and beam size at beam trap?
  
  2511   Tue Jan 12 14:28:01 2010 steveSummaryEnvironmentlab temp of 7 years

    
        
 labtemp7y.png 
  2514   Thu Jan 14 11:44:06 2010 josephbSummaryComputersMemory locations for TST model for ITMYThe main communications data structure
is RFM_FE_COMMS, from the rts/src/include/iscNetDsc40m.h
file.  The following comments regard
  
  2535   Thu Jan 21 10:09:27 2010 KojiSummaryIOOPhotos of the optical tablesI made a wiki page dedicated for the photos
of the optical tables.
The current layouts were uploaded.
  
  2539   Thu Jan 21 15:16:16 2010 josephb, kojiSummaryComputersMegatron used to lock Y armWe
succeeded in having a stable single arm (Y)
lock using Megatron to replace c1iscey.
Now
  
  2583   Tue Feb 9 17:18:45 2010 josephbSummaryComputersLocking Y arm successful with fully replaced front-end for ITMYWe were able to lock the Y-arm using Megatron
and the RCG generated code, with nothing
connected to c1iscey.
  
  2584   Tue Feb 9 17:51:48 2010 JenneSummaryIOOInput Mode Matching Telescope design is completeThe upgrade's input mode matching telescope
design is complete.  A summary document
is on the MMT
  
  2588   Wed Feb 10 23:44:56 2010 KojiSummaryCOCPhase Map AnalysisIn the middle of the last month, Kiwamu
and I went to Garilynn's lab to measure the
phase maps of the new ITMs and SRMs.
 SRM01_HR_RoC_rad_15mm.pngSRM01_HR_RoC_scan.png 
  2645   Sun Feb 28 16:45:05 2010 ranaSummaryGeneralPower ON Recovery
    Turned ON the RAID above linux1.

   Hooked up a monitor and keyboard and
then turned ON linux1.
    After
  
  2664   Tue Mar 9 09:32:31 2010 KojiSummaryGeneralWideband measurement of Fast PZT responseI have measured a wideband response
of the fast PZT in the LWE NPRO 700mW in
the Alberto's setup.
 PZT_response.png 
  2682   Thu Mar 18 15:33:17 2010 kiwamuSummaryElectronicsadvantege of our triple resonant EOMIn
this LVC meeting I discussed about triple
resonant EOMs with Volker who was a main
 electrode.png 
  2683   Thu Mar 18 19:00:04 2010 KojiSummaryElectronicsadvantege of our triple resonant EOMDid you find what is the merit of their
impedance matching technique?

  
  2688   Sat Mar 20 18:34:19 2010 kiwamuSummaryElectronicsRE:advantege of our triple resonant EOMYes, I found it.
Their advantage is that their circuit
is isolated at DC because of the input capacitor.
  
  2692   Mon Mar 22 02:03:57 2010 ranaSummaryElectronicsUPDH Box #17: ReadyIt took too long to get this box ready
for action. I implemented all of the changes
that I made on the previous one (#1437).
  
  2693   Mon Mar 22 10:07:30 2010 KojiSummaryElectronicsUPDH Box #17: ReadyFor your reference: Voltage noise of LM7815/LM7915
(with no load)
 15V_power_supply.pdf 
  2720   Sun Mar 28 20:05:33 2010 ranaSummaryPSLFSS Work from Sunday: AOM/VCO level set wrongJust before working on the FSS today, I
noticed that the VCO RF output level was
set incorrectly.
 Untitled.png 
  2721   Sun Mar 28 20:51:31 2010 ranaSummaryPSLFSS Work from Sunday: Cavity Suspension is Ridiculously Undamped!What
is the Transfer Function of the suspension
 Untitled.png 
  2722   Sun Mar 28 23:17:46 2010 ranaSummaryPSLFSS Work from Sunday: noise specThis is the error point spectrum - it is
filled with huge multiples of ~75 kHz as
Yoichi noticed a couple years ago.
 in2.png 
  2723   Sun Mar 28 23:47:47 2010 ranaSummaryPSLFSS Work from Sunday: Open Loop GainI measured the open loop gain of the FSS
(as usual, I have multiplied the whole OLG
by 10dB to account for the forward loop gain
 fssloop.pngsweep2.png 
  2724   Mon Mar 29 01:11:33 2010 ranaSummaryPSLFSS Work from Sunday: RF Out SpectrumI measured the RF spectrum coming out
the FSS RFPD to look for saturations - its
close to the hairy edge. This is with
 rfout.pngTEK00000.PNGTEK00001.PNGTEK00002.PNG 
  2726   Mon Mar 29 02:07:50 2010 KojiSummaryPSLFSS Work from Sunday: Open Loop Gain


   
        
            
  
  2735   Tue Mar 30 21:11:42 2010 kiwamuSummaryGreen Lockingconversion efficiency of PPKTPWith a
30mm PPKTP crystal the conversion efficiency
 efficiency_waist_edit.png 
  2736   Tue Mar 30 22:13:49 2010 KojiSummaryGreen Lockingconversion efficiency of PPKTPQuestion:
Why does the small spot size for
the case (A) have small efficiency as the
  
  2740   Wed Mar 31 11:52:32 2010 kiwamuSummaryGreen LockingRe:conversion efficiency of PPKTPGood point. There is a trick 
to avoid a divergence.
Actually the radius of the cylindrical
  
  2762   Sun Apr 4 00:21:42 2010 rana, kojiSummaryElectronicsCheckout of EG&G (PARC) preamp model #113, s/n 49135We tested out the functionality of the
EG&G 113 preamp that I found in one of
the cabinets. This is one of the ancestors
 IMG_0628.JPG 
  2793   Mon Apr 12 19:50:30 2010 AidanSummaryGreen LockingTemperature sweep of the Lightwave: df/dT = 2.8GHz/KThe beams from the Innolight and Lightwave
NPROs were both incident on a 1GHZ New Focus
PD. Mott and I swept the temperature of the
 LightWave_temp_sweep.pdfLightWave_Temp.m 
  2794   Mon Apr 12 20:48:51 2010 Aidan, MottSummaryGreen LockingTemperature sweep of the Innolight: df/dT ~ 3.3GHz/K

    
        
 Innolight_temp_sweep.pdfInnolight_Temp.m 
  2797   Tue Apr 13 12:39:51 2010 Aidan, MottSummaryGreen LockingTemperature sweep of the Innolight: df/dT ~ 3.3GHz/KPlease put those numbers onto wiki somewhere
at the green page or laser characterization
page.
  
  2814   Tue Apr 20 09:15:15 2010 steveSummarySAFETYannual safety audit   safa.PDF 
  2835   Fri Apr 23 18:30:49 2010 Aidan, Jenne, KojiSummaryGreen LockingGreen means GO!Jenne, Koji and I assembled the Covesion
Oven today, inserted a PPKTP crystal from
Raicol, aligned the crystal to a 50mW focus
 IMG_2405.jpgIMG_2417.jpg 
  2863   Sun May 2 13:04:51 2010 KojiSummarySUSCoil Actuator Balancing and Spot PositionI liked to know quantitatively where the
spot is on a mirror.

With an interferometer and A2L
 coil_balance.png 
  2865   Sun May 2 15:38:12 2010 ranaSummarySUSCoil Actuator Balancing and Spot Position 
Oh, but it gets even better: in order
to trust the A2L script in this regard you
  
  2866   Sun May 2 16:52:44 2010 KojiSummarySUSCoil Actuator Balancing and Spot PositionYes, of course. But so far I am trusting
that the coils are inheretly balanced.
Probably you are talking about the
  
  2891   Thu May 6 19:23:54 2010 FrankSummaryComputerssvn problemsi tried to commit something this afternoon
and got the following error message:
Command: Commit  
  
  2899   Sat May 8 02:38:08 2010 KojiSummaryIOOMC incident powerAs per Steve's request I checked the
MC incident power as a function of time.
The output is negative: the lower
 MC_input.png 
  2903   Mon May 10 17:47:16 2010 josephbSummaryCDSFinishedSo I finished writing a script which takes
an .ipc file (the one which defines channel
names and numbers for use with the RCG code
  
  2908   Mon May 10 20:33:29 2010 KojiSummaryCDSFinishedThis IPC stuff looks really a nice improvement
of CDS.
Please just maintain the wiki updated
  
  2928   Thu May 13 23:59:46 2010 ZachSummaryIOOMC table leveled After the recent removal of the old
IMMT and the relocation of the Faraday isolator,
the MC table was tilted a bit (southward
  
  2929   Fri May 14 03:30:45 2010 KojiSummaryIOOMC table leveledThanks Zach.This was a great job.
It was not mentioned but: was the
Faraday clamped down on the table?
  
  2931   Fri May 14 10:33:01 2010 ZachSummaryIOOMC table leveledAh... no, I didn't. That explains why there
were loose dogclamps on the table. I wrapped
them in foil and put them on the clean cart.
  
  2935   Sat May 15 04:13:33 2010 KojiSummaryIOOMC table leveledFixing at the next time is absolutely OK.

  
  2995   Wed May 26 18:54:55 2010 AidanSummaryGreen LockingMounted Crystal 724 in the Doubling OvenAndri and I mounted the Raicol Crystal
#724 in one of the new Covesion Ovens. The
procedure was the same as before - see
  
  3048   Thu Jun 3 22:33:31 2010 valeraSummaryCDSsimulated plant work I put matlab files and a summary
into the 40m wiki for the fitting of the
40m Optickle transfer functions and generating
  
  3052   Sun Jun 6 08:08:05 2010 rana, sanjitSummaryElectronicsCapacitor Bridge TestTo get a feel for the Capacitive Bridge
problems, we setup a simple bridge using
fixed (1 nF) caps on a breadboard. We used
 CapacitanceBridge.png 
  3061   Wed Jun 9 21:05:44 2010 ranaSummaryComputersop540m is not to be usedThis is a reminder (mainly for Steve, who somehow   
ELOG V3.1.3-