Entry  Thu Nov 6 12:53:09 2014, diego, Update, ASC, X arm restored 
Entry  Thu Nov 6 03:29:00 2014, diego, Update, LSC, IR Resonance Script Status AllPython_findIRresonance_WL_ramp_20_500_0.pngAllPython_findIRresonance_WL_ramp_20_500_0_1.pngAllPython_findIRresonance_WL_ramp_20_500_6.pngAllPython_findIRresonance_WL_ramp_20_500_7_Y_rise.pngAllPython_findIRresonance_WL_ramp_20_500_9.png
Entry  Thu Nov 6 01:48:30 2014, diego, Update, LSC, IR Resonance Script Status 
Entry  Wed Nov 5 17:50:29 2014, manasa, Update, General, PSL and AUXY beatnote in IR found PSLsetup.jpg
    Reply  Wed Nov 5 18:08:00 2014, ericq, Update, LSC, PSL and AUXY beatnote in IR found 
Entry  Tue Nov 4 14:46:00 2014, manasa, Update, Green Locking, Missing beatnotes 
Entry  Mon Nov 3 17:56:57 2014, Koji, Update, LSC, SRM calibration SRY_SRM_CALIB_RAW.pdfSRY_SRM_CALIB.pdf
Entry  Mon Nov 3 17:14:00 2014, ericq, Update, ASC, IMC to IFO angular motion 2014-10-03-MC2T_to_POPQPD.pdf
    Reply  Mon Nov 3 17:43:14 2014, Koji, Update, ASC, IMC to IFO angular motion 
Entry  Sat Nov 1 02:13:11 2014, Koji, Configuration, LSC, LSC settings 
Entry  Fri Oct 31 19:59:26 2014, Koji, Update, General, Some locking work / PRMI analysis PRMIsb_PRCL_OLTF.pdfPRMIsb_MICH_OLTF.pdfPRMIsb_PRCL_SPE.pdfPRMIsb_MICH_SPE.pdf
Entry  Mon Jun 11 16:08:58 2012, Jenne, Update, Environment, Rattling in the HEPA 
    Reply  Mon Jun 11 21:35:55 2012, Jenne, Update, Environment, Rattling in the HEPA 
       Reply  Fri Oct 31 11:46:15 2014, manasa, Update, , Rattling HEPA : Eventually stops 
          Reply  Fri Oct 31 15:34:47 2014, Steve, Update, PSL, PSL HEPAs are running again HepaVariac.jpg
Entry  Fri Oct 31 02:19:37 2014, ericq, Update, LSC, Some SRMI progress 
Entry  Tue Oct 21 17:44:28 2014, jamie, Omnistructure, Computer Scripts / Programs, new version of cdsutils (351) installed 
    Reply  Thu Oct 30 16:25:22 2014, ericq, Omnistructure, Computer Scripts / Programs, new version of cdsutils (361) installed 
Entry  Thu Oct 30 02:54:38 2014, diego, Update, LSC, IR Resonance Script Status AllPython_findIRresonance_WL_X_ramp_20_500_2.pngAllPython_findIRresonance_WL_Y_ramp_20_500_2.pngAllPython_findIRresonance_WL_ramp_20_500_2.png
Entry  Mon Oct 27 19:15:54 2014, ericq, Update, LSC, Trying to PRMI on 165 
    Reply  Wed Oct 29 03:33:38 2014, ericq, Update, LSC, Trying to PRMI on 165 
       Reply  Thu Oct 30 01:21:37 2014, Jenne, Update, LSC, No MICH in REFL165 MICH_to_REFL165_29Oct2014.pdf
Entry  Fri Sep 5 15:28:38 2014, Steve, Update, SUS, HeNe laser test preparation beforeRSMqpdMoved.jpgafterSRMqpdMoved.jpg1103Ptest.pngND1onQPD.png
    Reply  Fri Sep 5 16:25:36 2014, Steve, Update, SUS, center ITMY oplev 
    Reply  Tue Sep 9 08:22:28 2014, Steve, Update, SUS, HeNe laser test preparation HeNecompared.png
       Reply  Tue Sep 9 16:59:32 2014, Steve, Update, SUS, HeNe laser test preparation 1103PqpdTranss.png
          Reply  Wed Sep 10 14:58:58 2014, Jenne, Update, SUS, OpLev test: New channels 
             Reply  Thu Sep 11 17:12:42 2014, Steve, Update, SUS, OpLev test: old SP qpd connected 
                Reply  Fri Sep 12 16:30:48 2014, Steve, Update, SUS, HeNe laser test preparation ND2.pngqpd222ND21103P.jpg
                   Reply  Wed Sep 17 13:41:00 2014, Jenne, Update, SUS, New calibrated channels for test QPD NewQPDcalibratedChans.png
                      Reply  Thu Sep 18 09:17:47 2014, Steve, Update, SUS, HeNe laser test  calibrated_16hrs.pngQPD222cal.jpg1103P40s40min.png
                         Reply  Mon Sep 22 10:14:07 2014, Steve, Update, SUS, HeNe laser test  1103Pmon3d.png
                            Reply  Tue Sep 23 08:34:14 2014, Steve, Update, SUS, HeNe laser test  tempDrop.png
                               Reply  Thu Sep 25 10:53:32 2014, Steve, Update, SUS, HeNe laser test  centeredDay6.png
          Reply  Wed Sep 10 15:31:16 2014, Steve, Update, SUS, HeNe laser test preparation SRMqpdisBack0nSRMsus.pngslowVSfast.png
    Reply  Wed Oct 15 17:09:49 2014, manasa, Update, General, Diode laser test preparation 
       Reply  Wed Oct 29 18:07:28 2014, manasa, Update, General, Diode laser test preparation 
Entry  Tue Oct 21 18:40:46 2014, manasa, Update, General, End laser fiber setup 
    Reply  Fri Oct 24 10:08:24 2014, manasa, Update, General, Y AUX laser - fiber coupled 
       Reply  Fri Oct 24 18:53:23 2014, rana, Update, General, Y AUX laser - fiber coupled 
       Reply  Mon Oct 27 12:17:46 2014, manasa, Update, General, Y AUX laser coupling telescope design AUXmode.zipAUXmode.png
          Reply  Wed Oct 29 11:45:11 2014, manasa, Update, General, Y AUX laser - fiber coupled (52%) 31.png
Entry  Tue Oct 28 20:47:08 2014, diego, Update, IOO, IMC WFS sensing matrix measurement 6x
Entry  Tue Oct 28 14:07:28 2014, Koji, Update, IOO, IMC WFS sensing matrix measurement 00.png
    Reply  Tue Oct 28 15:27:25 2014, ericq, Update, IOO, IMC WFS sensing matrix measurement 45.png
Entry  Tue Oct 28 01:12:57 2014, Jenne, Update, SUS, ETMX bad :( 
    Reply  Tue Oct 28 02:44:08 2014, Jenne, Update, SUS, ETMX bad :( 
       Reply  Tue Oct 28 11:45:21 2014, manasa, Update, SUS, ETMX - observation 
Entry  Mon Oct 27 22:19:17 2014, Jenne, Update, CDS, c1iscex restarted 
Entry  Thu Oct 23 02:08:40 2014, Jenne, Update, LSC, Increased DARM gain 6x
    Reply  Fri Oct 24 02:14:05 2014, Jenne, Update, LSC, Increased DARM gain even more DARM_23Oct2014.pdf
Entry  Thu Oct 23 17:45:54 2014, Jenne, Update, General, Pianosa frozen 
Entry  Tue Oct 7 10:09:07 2014, manasa, Update, General, Chiara not responding 
    Reply  Tue Oct 7 16:19:50 2014, ericq, Update, General, Chiara not responding 
       Reply  Tue Oct 7 16:41:12 2014, Jenne, Update, General, Chiara not responding 
       Reply  Thu Oct 23 13:08:55 2014, ericq, Update, General, Gap in local Chiara backups 
Entry  Thu Oct 16 03:18:48 2014, Jenne, Update, CDS, Daqd segfaulting again 
    Reply  Thu Oct 16 12:22:43 2014, ericq, Update, CDS, Daqd segfaulting again 
       Reply  Fri Oct 17 15:17:31 2014, jamie, Update, CDS, Daqd "fixed"? 
          Reply  Fri Oct 17 16:54:11 2014, jamie, Update, CDS, Daqd "fixed"? 
             Reply  Thu Oct 23 01:39:34 2014, Jenne, Update, CDS, Daqd "fixed"? 
Entry  Mon Sep 15 18:55:51 2014, rana, Update, DAQ, 40m frames onto the cluster 
    Reply  Wed Oct 22 21:06:33 2014, Chris, Update, DAQ, 40m frames onto the cluster 
Entry  Wed Oct 15 20:10:29 2014, ericq, Update, LSC, Interim DARM Signal 7x
    Reply  Thu Oct 16 16:21:42 2014, ericq, Update, LSC, Interim DARM Signal dcDARMSweep-300.pdfdcDARMSweep-120.pdfdcDARMSweep-50.pdfdcDARMSweep-0.pdf
       Reply  Thu Oct 16 21:20:59 2014, rana, Update, LSC, misleading modelling 
          Reply  Fri Oct 17 03:05:00 2014, ericq, Update, LSC, DARM locked on DC Transmission difference TRdifflock.pngOct17lock.pdf
             Reply  Fri Oct 17 13:19:48 2014, Jenne, Update, LSC, POP22 ?!?! 
          Reply  Tue Oct 21 00:38:40 2014, ericq, Update, LSC, sweep + RMS as uncertainty dcCARMSweep_uncertainties.png
             Reply  Wed Oct 22 06:32:29 2014, rana, Update, LSC, sweep + RMS as uncertainty 
Entry  Wed Oct 22 02:35:45 2014, Jenne, Update, LSC, Efforts at hopping PRMI to REFL165 
Entry  Thu Oct 9 16:31:53 2014, ericq, Update, LSC, CARM W/N TFs carm2SQRTinv.pdfcarm2REFLDC.pdf
    Reply  Thu Oct 9 18:30:59 2014, Jenne, Update, LSC, CARM W/N TFs 6x
       Reply  Fri Oct 10 00:20:37 2014, rana, Update, LSC, CARM W/N TFs carm40.pngcarm.pdf
          Reply  Wed Oct 15 02:59:04 2014, rana, Update, LSC, CARM W/N TFs spring.pdfantispring.pdf
             Reply  Thu Oct 16 22:35:05 2014, rana, Update, LSC, CARM W/N TFs carm_spring.pdfcarm_antispring.pdf
       Reply  Wed Oct 15 13:38:33 2014, Jenne, Update, LSC, CARM W/N TFs 7x
          Reply  Mon Oct 20 17:50:30 2014, Jenne, Update, LSC, CARM W/N TFs (Others were all wrong!) 7x
Entry  Fri Oct 17 17:52:55 2014, Jenne, Update, LSC, RAM offsets 16x
Entry  Thu Oct 16 03:13:23 2014, Jenne, Update, LSC, PRMI on REFL165, and more 
Entry  Wed Oct 15 22:39:17 2014, Jenne, Update, LSC, The Plan 
Entry  Fri Oct 10 03:05:09 2014, ericq, Update, LSC, Which side of optical spring are we on? comparison.pdf
    Reply  Fri Oct 10 03:25:11 2014, Jenne, Update, LSC, Which side of optical spring are we on (simulation) 10x
    Reply  Mon Oct 13 12:01:28 2014, ericq, Update, LSC, Which side of optical spring are we on? AOInjection_SqrtInv_REFLDC.pngAOinjection_SqrtInv_REFLDC.xml.zip
       Reply  Mon Oct 13 21:20:56 2014, Jenne, Update, LSC, Which side of optical spring are we on? (No progress) 
          Reply  Mon Oct 13 21:59:47 2014, rana, Update, Computer Scripts / Programs, Which side of optical spring are we on? (No progress) 
             Reply  Tue Oct 14 17:38:31 2014, ericq, Update, Computer Scripts / Programs, Rossa and Allegra wiped, Ubuntu 12.04 installed 
                Reply  Tue Oct 14 23:44:42 2014, diego, Update, Computer Scripts / Programs, Rossa and Allegra wiped, Ubuntu 12.04 installed 
                   Reply  Wed Oct 15 17:18:10 2014, Jenne, Update, Computer Scripts / Programs, Dataviewer fix with Ubuntu 12.04 
          Reply  Wed Oct 15 02:58:03 2014, Jenne, Update, LSC, Which side of optical spring are we on?  PRFPMI_MC2injection_PosCARMoffset_REFLDC_TRX_response_14Oct2014_TRX.pdfPRFPMI_MC2injection_PosCARMoffset_REFLDC_TRX_response_14Oct2014_REFLDC.pdfPRFPMI_MC2injection_NegCARMoffset_REFLDC_TRX_response_14Oct2014_TRX.pdfPRFPMI_MC2injection_NegCARMoffset_REFLDC_TRX_response_14Oct2014_REFLDC.pdf
             Reply  Wed Oct 15 19:56:38 2014, Jenne, Update, LSC, Which side of optical spring are we on? Meas vs Model AntispringModel_NegOffsetMeas_comparison.pdfSpringModel_NegOffsetMeas_comparison.pdf
Entry  Mon Oct 13 16:08:49 2014, Jenne, Update, CDS, Frame builder is mad Daqd_problem_maybe.png
    Reply  Mon Oct 13 16:57:26 2014, Koji, Update, CDS, Frame builder is mad 
       Reply  Mon Oct 13 17:09:38 2014, ericq, Update, CDS, Frame builder is mad 
Entry  Thu Oct 9 10:52:37 2014, manasa, Update, General, Power outage II & recovery 
    Reply  Thu Oct 9 11:56:35 2014, Steve, Update, VAC, Power outage II & recovery 
       Reply  Thu Oct 9 13:29:14 2014, Jenne, Update, PSL, Power outage II & recovery 
       Reply  Thu Oct 9 17:33:28 2014, Steve, Update, VAC, Power outage II & recovery pumpingAgain.png
          Reply  Thu Oct 9 19:14:04 2014, ericq, Update, General, Power outage II & recovery 
          Reply  Fri Oct 10 14:41:04 2014, Steve, Update, VAC, Power outage II & recovery recovery_poweroutage.png
Entry  Mon Jun 9 11:42:00 2014, Jenne, Update, CDS, Computer status 
    Reply  Mon Jun 9 12:19:17 2014, ericq, Update, CDS, Computer status 
       Reply  Mon Jun 9 22:26:44 2014, rana, zach, Update, CDS, SLOW controls recovery 
          Reply  Wed Jun 11 14:36:57 2014, Jenne, Update, CDS, SLOW controls recovery 
             Reply  Wed Jun 11 15:57:18 2014, Jenne, Update, CDS, Note on cables for talking to slow computers 06111401.PDF
                Reply  Thu Jun 12 15:31:47 2014, Jamie, Update, CDS, Note on cables for talking to slow computers 
             Reply  Wed Jun 11 16:01:31 2014, Steve, Update, CDS, c1Vac1 and c1vac2 rebooted beforeReboot.png
                Reply  Fri Oct 10 14:27:44 2014, Steve, Update, CDS, c1Vac1 and c1vac2 reboot was a failure c1vac1resetReboot.pngc1Vac1&2down.jpg
       Reply  Wed Oct 8 15:31:31 2014, Jenne, Update, CDS, Computer status 
    Reply  Mon Jun 9 22:40:36 2014, Jenne, Update, CDS, Fast front end computers up 
    Reply  Tue Jun 10 09:25:29 2014, Jamie, Update, CDS, Computer status: should not be changing names 
Entry  Wed Oct 8 03:37:44 2014, ericq, Update, LSC, PRFPMI, other sign of CARM offset 
    Reply  Wed Oct 8 03:49:42 2014, Jenne, Update, LSC, PRFPMI, other sign of CARM offset 
Entry  Wed Oct 8 03:20:46 2014, Jenne, Update, LSC, Do we need AO for acquisition? EstimatedNoisePerformance.pngBodeLSCvsALS.pngCARMnoise_7Oct2014.zip
Entry  Tue Oct 7 19:40:58 2014, ericq, Update, LSC, CM, REFL11 Wiring 
Entry  Tue Oct 7 00:18:12 2014, Jenne, Update, LSC, Ygreen PSL alignment, ETMX strain relief 
Entry  Thu Oct 2 20:54:45 2014, Koji, Update, IOO, IMC WFS measurements IMC_RIN_141002.pdfIMC_WFS_141002.pdf
    Reply  Fri Oct 3 13:03:05 2014, ericq, Update, IOO, IMC WFS measurements WFS1PIT.pdfWFS2PIT.pdfWFS1YAW.pdfWFS2YAW.pdfanalyzeWfs.zip
       Reply  Sun Oct 5 10:09:49 2014, rana, Update, IOO, IMC WFS measurements 
          Reply  Sun Oct 5 23:43:08 2014, Koji, Update, IOO, IMC WFS measurements 
Entry  Fri Oct 3 03:02:17 2014, ericq, Update, LSC, No luck locking DRMI 
Entry  Tue Feb 28 11:20:51 2012, steve, Update, SAFETY, safety audit 2012 safety12.JPG
    Reply  Fri Mar 30 09:37:13 2012, steve, Update, SAFETY, safety audit 2012 CORRECTIONS 
       Reply  Wed Mar 6 11:33:09 2013, steve, Update, SAFETY, safety audit 2013 IMG_0010.JPG
          Reply  Wed Mar 13 16:04:24 2013, steve, Update, SAFETY, laser safety glasses checked safetyglasseschecked.jpg
             Reply  Wed Feb 19 08:07:01 2014, steve, Update, safety, annual laser safety glasses check  AA2014checked.jpg2014check.jpg
                Reply  Tue Feb 25 16:54:57 2014, steve, Update, safety, safety audit 2014 
                   Reply  Thu Feb 27 13:11:13 2014, steve, Update, safety, safety audit correction noDaisyChaining.jpgZbThumbnail.info
                   Reply  Thu Mar 13 16:05:48 2014, steve, Update, safety, safety audit 2014 T1400198-v1-CIT-LIGO_Labs_Annual_Safety_Audit_2014.pdf
                      Reply  Mon Mar 17 10:50:58 2014, steve, Update, safety, 2014 annual crane certification 2014craneCert.jpg
                         Reply  Thu Oct 2 14:36:52 2014, steve, Update, PEM, oil drops on vertex crane VertexOilDrops.jpg
                      Reply  Mon Apr 28 17:27:29 2014, steve, Update, safety, safety audit 2014 
                         Reply  Tue Apr 29 00:11:03 2014, steve, Update, safety, safety audit 2014 
                            Reply  Fri May 2 08:15:54 2014, steve, Update, safety, safety audit 2014 solidCoverRequired.jpg
          Reply  Tue Mar 19 10:30:00 2013, steve, Update, SAFETY, crane inspection 2013 sippingOIL.jpg03191301.PDF
          Reply  Fri May 31 10:25:17 2013, steve, Update, safety, first aid kits refilled refilledFAidK.jpg
             Reply  Thu Jun 6 16:33:19 2013, steve, Update, safety, updated laser inventory ELSOconnected.jpg
          Reply  Fri Aug 30 08:08:29 2013, steve, Update, safety, fire horns-flashers tested OK 
Entry  Wed Oct 1 19:40:46 2014, ericq, Update, LSC, Arms IR aligned 
Entry  Thu Sep 18 02:42:28 2014, Jenne, Update, LSC, AO path partly engaged Zoom_TRXTRY4_EngagingAO_1095059162.png0020.pdf
    Reply  Thu Sep 18 17:44:55 2014, Jenne, Update, LSC, Old AO cable pulled 
       Reply  Tue Sep 30 17:26:18 2014, ericq, Update, LSC, New AO cable in place 
    Reply  Fri Sep 19 04:05:05 2014, ericq, Update, LSC, AO path partly engaged TFSR785_19-09-2014_020555.pdfTFSR785_19-09-2014_033920.pdf
       Reply  Fri Sep 19 13:12:07 2014, Jenne, Update, LSC, AO path glitches 
Entry  Wed Sep 24 13:28:48 2014, Steve, Update, VAC, vent is completed ventiscompleted.pngatAtm.png
    Reply  Wed Sep 24 16:02:58 2014, Jenne, Update, VAC, vent is completed 
       Reply  Wed Sep 24 18:17:46 2014, ericq, Update, General, Alignment Restored 
       Reply  Thu Sep 25 08:21:15 2014, Steve, Update, VAC, vent day 1 ventDay1.png
          Reply  Mon Sep 29 09:11:25 2014, Steve, Update, VAC, vent day 5 RGA scan v77_bg-mag-d5.png
             Reply  Mon Sep 29 10:29:25 2014, Steve, Update, VAC, RGA is not running rgascanTimeStamp.png
Entry  Fri Sep 26 11:44:55 2014, nicolas, Frogs, Computer Scripts / Programs, Loaded larry's fake filter into C1:ALS-OFFSETTER2 
Entry  Fri Sep 26 09:13:17 2014, Steve, Update, SUS, vent day 2 ventDay2.pngITMY.png
Entry  Mon Jun 16 21:22:16 2014, Jenne, Update, Computer Scripts / Programs, Rossa having a bad day 
    Reply  Wed Jun 18 19:30:28 2014, Jenne, Update, Computer Scripts / Programs, Rossa having a better day 
       Reply  Thu Sep 25 15:41:15 2014, ericq, Update, Computer Scripts / Programs, Rossa having a better day 
Entry  Fri Sep 12 00:40:23 2014, Jenne, Update, LSC, DRMI locking 
    Reply  Fri Sep 12 11:25:42 2014, Koji, Update, LSC, DRMI locking 
       Reply  Fri Sep 12 12:00:59 2014, ericq, Update, LSC, DRMI locking 
    Reply  Fri Sep 12 14:11:17 2014, ericq, Update, LSC, DRMI locking 7x
       Reply  Wed Sep 17 15:40:00 2014, ericq, Update, LSC, DRMI locking dcAngleDiff_srcL.pdfdrfpmiVertexSensing.zip
          Reply  Tue Sep 23 17:37:10 2014, ericq, Update, LSC, DRMI locking SRCcorrection.pdf
             Reply  Wed Sep 24 11:02:38 2014, manasa, Update, LSC, Moving SRM 
                Reply  Thu Sep 25 11:33:41 2014, Jenne, Update, LSC, POY alignment laser 
Entry  Wed Sep 24 18:56:45 2014, ericq, Update, General, Ottavia slowness 
ELOG V3.1.3-