40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 45 of 341  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  2217   Mon Nov 9 15:11:02 2009 AlbertoUpdateLSCEverything put back as it was


   
        
            
  
  2218   Mon Nov 9 15:21:37 2009 JenneUpdateGeneralDrill Press is down for the count

    
        
  
  2219   Mon Nov 9 16:32:36 2009 AlbertoFrogsEnvironmentShot of the white board yesterday before erasingYesterday Rana and I needed some room on
the white board in the Control Room. We had
to erase some of the stuff present on the
 DSC_0980.JPGDSC_0980.JPG 
  2220   Mon Nov 9 18:27:30 2009 AlbertoFrogsComputersOMC DCPD Interface Box Disconnected from the power SupplyThis afternoon I inadvertently disconnected
one of the power cables coming from the power
supply on the floor next to the OMC cabinet
  
  2221   Mon Nov 9 18:32:38 2009 robUpdateComputersOMC FE hosedIt won't start--it just sits at Waiting
for EPICS BURT, even though the EPICS is
running and BURTed.
  
  2222   Mon Nov 9 19:04:23 2009 robUpdateComputersOMC FE hosed


   
        
            
  
  2223   Mon Nov 9 19:09:09 2009 JenneUpdatePEMNoise floor of the Ranger SeismometerTo estimate the noise floor of the Ranger,
Rana and I locked the mass on the seismometer,
so there will be no (aka minimal) signal
 Ranger_noiseFloor_Spectra.png 
  2224   Mon Nov 9 19:44:38 2009 rob, ranaUpdateComputersOMC FE hosed 
We found that someone had set the
name of megatron to scipe11. This is the
  
  2225   Tue Nov 10 10:51:00 2009 josephb, alexUpdateComputersMegatron on, powercycled c1omc, and burt restored from 3am snapshotLast night around 5pm or so, Alex had remotely
logged in and made some fixes to megatron.
First, he changed the local name
  
  2226   Tue Nov 10 13:02:36 2009 AlbertoUpdateLSCX and Y Arm Cavity Poles MeasurementFrom fitting the arm cavity transfer functions
I got the following values for the cavity
pole frequencies.
 SummaryOfFits.pdfCodeAndData.tar 
  2227   Tue Nov 10 17:01:33 2009 AlbertoConfigurationIOOc1ioovme and c1iool0 rebooted This afternoon, while I was trying to add
the StochMon channels to the frames, I rebooted
the c1ioovme and c1iool0.
  
  2228   Tue Nov 10 17:49:20 2009 AlbertoMetaphysicsComputersTest Point Number MappingI found this interesting entry by Rana
in the old (deprecated) elog : here
I wonder if Rolf has ever written
  
  2229   Tue Nov 10 19:19:57 2009 AlbertoUpdateABSLRotated polarizer on the PSL table, along the MC input pick off beam Aligning the beam for the PLL of the AbsL
Experiement I rotated the polarizer along
the path of the MC Input pick off beam (=
  
  2230   Tue Nov 10 19:21:53 2009 AlbertoUpdateABSLPLL AlignmentI've been trying to lock the PLL for the
AbsL Experiment but I can't see the beat
(between the auxiliary NPRO and the PSL).
  
  2231   Tue Nov 10 21:46:31 2009 ranaSummaryComputersTest Point Number Mapping


   
        
            
  
  2232   Wed Nov 11 00:55:47 2009 JenneUpdateAdaptive FilteringTerms put on some ADC inputsMostly a note to self:  I have put
terminators on the ADC inputs which are usually
the PEM-SEIS-GUR2_(XYZ) channels.  Since
  
  2233   Wed Nov 11 01:33:52 2009 peteUpdateCDSRCG ETMY code update I've added the side coil to the model
controller and plant, and the oplev quad
to the model controller and plant.  After
  
  2234   Wed Nov 11 09:48:04 2009 steveUpdateIOOwhere is IOO-RFAMPD_DCMON ?RFAMPD_DCMON disappered on Nov 5, 2009  rfampddc.jpg 
  2236   Wed Nov 11 12:29:44 2009 AlbertoFrogsPSLMC Locked on the wrong mode?This morning, after Steve pointed out that
the readout RFAMPD_DC was zero, I thought
of realigning the beam on the photodiode.
 PB110184-1.JPG 
  2237   Wed Nov 11 12:50:10 2009 JenneUpdatePEMSeismometer Noise CharacteristicsThe attached plot shows the spectra of
the 3 Z axes of the 3 seismometers we have
(this data is from ~20Aug2009, when the Ranger
 HuddleTest_Aug2009data.png 
  2238   Wed Nov 11 15:04:52 2009 AlbertoUpdateABSLWorking on the AP tableI've opened the AP table and I'm working
on it.
  
  2239   Wed Nov 11 16:18:57 2009 AlbertoUpdateABSLWorking on the AP table


   
        
            
  
  2240   Wed Nov 11 17:10:51 2009 JenneUpdateABSLWorking on the AP table

    
        
  
  2241   Wed Nov 11 17:33:54 2009 KojiUpdateABSLWorking on the AP tableYes it did.
For long time, the crystal temperature
C1:PSL-126MOPA_LTMP was 43~46deg. Now
  
  2242   Wed Nov 11 18:43:57 2009 rana, kojiHowToPhotosIlluminated Paintbrush Technique   IMG_0215.JPGIMG_0214.JPG 
  2243   Wed Nov 11 20:46:07 2009 peteUpdateCDSRCG ETMY phase I updateThe .mdl code for the mdc and
mdp
  
  2244   Wed Nov 11 20:57:06 2009 kiwamuUpdateElectronicsMulti-resonant EOM --- LC tank circuit ---I have been working about multi-resonant
EOM since last week.
In order to characterize the behavior
 DSCN0160.JPGLCtank_complete.png 
  2245   Wed Nov 11 21:30:20 2009 HaixingUpdateGeneralmagnetic levitation modelling files uploaded to svnI have created a directory under the svn.
The link is https://nodus.ligo.caltech.edu:30889/svn/trunk/docs/haixing
  
  2246   Thu Nov 12 01:18:34 2009 haixingUpdateSUSopen-loop transfer function of mag levi system (comparison between simulink and measurement)I built a Simulink model of the magnetic
levitation system and try to explain
the dip in the open-loop transfer function
 block_diagram.pngcontribution_plot.pngmech_resp_plot.png 
  2247   Thu Nov 12 02:02:18 2009 ranaSummaryLSCArm Locking with no feedback to the ETM or ITMSteps:
1) Turn off feedback to ETMY (the
ETMY button on the LSC screen).
 nohands-2.pdf 
  2248   Thu Nov 12 09:43:29 2009 steveUpdatePEMconstruction has started at CESThe concrete  floor cutting has begun
next door at CES
 cuttingconcr.jpgcutcon1.JPGcutcon2.JPG 
  2249   Thu Nov 12 10:45:02 2009 AlbertoUpdatePSLAbandoned Frequency GeneratorThis morning I found a frequency generator
connected to something on the PSL table sitting
on the blue step next to the sliding doors.
  
  2250   Thu Nov 12 10:45:36 2009 AlbertoUpdateABSLWorking on the AP tableI've opened the AP table and I'm working
on it.
Also auxiliary NPRO turned on and
  
  2251   Thu Nov 12 11:19:10 2009 KojiUpdatePSLAbandoned Frequency GeneratorLast night there was an activity for a
calibratuon work, which I helped. I can take
care of the FG.
  
  2252   Thu Nov 12 11:34:38 2009 AlbertoUpdateABSLWorking on the AP table


   
        
            
  
  2253   Thu Nov 12 12:50:35 2009 AlbertoUpdateComputersStochMon calibrated channels added to the data trendI added the StochMon calibrated channels
to the data trend by including the following
channel names in the C0EDCU.ini file:
  
  2254   Thu Nov 12 12:51:45 2009 AlbertoUpdateABSLWorking on the AP table

    
        
  
  2255   Thu Nov 12 15:40:27 2009 josephb, koji, peterUpdateComputersETMY and Megatron test take 1We connected megatron to the IO chassis
which in turn was plugged into the rest of
the ITMY setup.  We had manually turned
  
  2256   Thu Nov 12 16:13:05 2009 AlbertoUpdatePSLMC Trans OffsetOn Rana's suggestion I checked the MC
transmission QPD (C1:IOO-MC_TRANS_SUM). I
found that the readout is almost zero when
  
  2257   Thu Nov 12 16:53:59 2009 AlbertoUpdateABSLWorking on the AP table


   
        
            
  
  2258   Thu Nov 12 17:15:43 2009 KojiUpdatePSLMC Trans OffsetOK. I have been keeping my eyes on the
MC transmission. In deed, the MC trans has
been well kept at around 7.7 since the last
 MC_TRANS.png 
  2259   Thu Nov 12 17:24:29 2009 Koji, Joe, PeterConfigurationCDSETMY CDS test startedWe started the test of the new CDS system
at ETMY.
The plan is as follows:
  
  2260   Thu Nov 12 17:42:04 2009 KojiUpdatePSLMC Trans OffsetPC_DRIVE is also improving after the last
PSL work!

 PC_DRV.png 
  2261   Thu Nov 12 18:10:27 2009 AlbertoUpdateABSLPLL LockedI locked the PLL and made some first measuremtns
of the spectrum of the error signal. I'll
post them later.
  
  2262   Fri Nov 13 03:38:47 2009 kiwamuUpdateElectronicsmulti-resonant EOM --- impedance of LC tank circuit ----I have measured the impedance of the LC
tank circuit which I referred on my
last entry.
 LCtank_impedance.pngLCtank_model.png 
  2263   Fri Nov 13 05:03:09 2009 kiwamuUpdateElectronicsmulti-resonant EOM --- input impedance of LC tank ----I measured the input impedance of the
LC tank circuit with the transformer. The
 input_impedance.pnginput_impedance2.png 
  2264   Fri Nov 13 09:47:18 2009 josephbUpdateComputersMegatron status lights litMegatron's top fan, rear ps, and temperature
front panel lights were all lit amber this
morning.  I checked the service manual,
  
  2265   Fri Nov 13 09:54:14 2009 josephbConfigurationComputersMegatron switched to tcshI've changed megatron's controls account
default shell to tcsh (like it was before). 
It now sources cshrc.40m in /cvs/cds/caltech/
  
  2266   Fri Nov 13 10:28:03 2009 josephb, alexUpdateComputersMegatron is back to its old selfI called Alex this morning and explained
the problems with megatron.
Turns out when he had been setting
  
  2267   Fri Nov 13 14:04:27 2009 josephb, kojiUpdateComputersUpdated wiki with RCG instructions/tipsI've placed some notes pertaining to what
Koji and I have learned today about getting
the RCG code working on the 40m wiki at:
  
ELOG V3.1.3-