40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 41 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject
  4881   Fri Jun 24 22:35:23 2011 ranaConfigurationCDSdataviewer broken on pianosa

When I try to get minute trend, it says "word too long".

  4886   Sun Jun 26 16:17:22 2011 ranaUpdateCDSdiagonalization of MC input matrix

I have updated the scripts/SUS/peakFit/ directory so that it now finds the SUS input matrix coefficients in addition to just finding the free-swinging peaks.

Procedure:

  1. Get OSEM sensors data via NDS2 from a time when the optics have been kicked and then left free swinging.
  2. Downsample the data to 64 Hz and save.
  3. Make power spectra with a 1 mHz resolution (i.e. we need a few hours of data) and  ~10 averages.
  4. use the fminsearch lorentzian peak fitter -> save the peak frequencies
  5. Make Transfer Function estimate matrix at the peak frequencies between all OSEMs (this makes a 5x4 complex matrix)
  6. The matrix should be real, so make sure its mostly real and then take the real part only
  7. Normalize (height of biggest peak for each f_DOF should be 1)
  8. Add a Butterfly mode vector. This makes the sensing matrix go from 5x4 to 5x5. (Butterfly a.k.a. Pringle)
  9. Invert
  10. Normalize so that the biggest element in each Sensor2DOF column is 1.
  11. Load values into MEDM screen and then verify by another free swinging data run.

 

The attached PDF shows how much rejection of the unwanted DOFs we get between the existing diagonal input matrix and this new empirical matrix. Previously, the decoupling was only a factor of a few for some of the modes. Now the decoupling is more like orders of magnitude (at least according to this calculation). It will be worse when we load it and then try another free swinging run. However, the fact that the suppression can be this good means that the variation in the coefficients at the ~hours time scale is at least this small (~< 0.1%)

 

That's the basic procedure, but there are a lot of important but mainly technical details:

  1. Free swinging data must be taken with the angle bias ON. Otherwise, we are not measuring the correct sensing gain (i.e. the magnets are not in their nominal place within the OSEM-LED beam)
  2. Data must be checked so that the shadow sensor outputs are in their linear regime: if they are exploring the cubic part, then the fundamental is being suppressed.
  3. Instead of just using the peak frequency, I average a few points around the peak to get better SNR before inversion. I think this will make the results more stable.
  4. All previous input matrix diagonalization efforts (Buckley, Sakata & Kawamura, Black, Barton, Gonzalez, Adhikari & Lawrence, Saulson,...) for the past ~15 years have been using the spectra's peak height data. Today's technique uses the TF and so is more precise. The coherent transfer function is always better than just using the magnitude data.
  5. This method is now fairly automatic - there's no human intervention in fudging values, choosing peak heights, frequencies, etc.
  6. We'll have to rerun this, of course, after the mirrors are aligned and after the OSEM whitening fiasco is cleaned up somewhat.

I'll set the optics to be aligned and then swing tonight.

Attachment 1: inMatDiag.pdf
inMatDiag.pdf
  4888   Sun Jun 26 22:38:20 2011 ranaUpdateCDSMC1 LR dead for > 1 month; now revived temporarily

 Since the MC1 LRSEN channel is not wasn't working, my input matrix diagonalization hasn't worked today wasn't working. So I decided to fix it somehow.

I went to the rack and traced the signal: first at the LEMO monitor on the whitening card, secondly at the 4-pin LEMO cable which goes into the AA chassis.

The signal existed at the input to the AA chassis but not in the screen. So I pressed the jumper wire (used to be AA filter) down for the channel corresponding to the MC1 LRSEN channel.

It now has come back and looks like the other sensors. As you can see from this plot and Joe's entry from a couple weeks ago, this channel has been dead since May 17th.

The ELOG reveals that Kiwamu caught Steve doing some (un-elogged) fooling around there. Burnt Toast -> Steve.

bt.jpg

993190663   =      free swinging ringdown restarted again

Attachment 1: lrsen.png
lrsen.png
  4889   Mon Jun 27 00:23:11 2011 ranaUpdateCDSETMX SIDE problem

The slow readback of the ETMX side seems to also have something flaky and bi-stable. This is not an issue for damping, but it disables the SIDE watchdog for ETMX and makes it unsafe if we accidentally use the wrong damping sign.

Attachment 1: etmx-side.png
etmx-side.png
  4918   Thu Jun 30 06:54:07 2011 josephbUpdateCDSModified the automated scripts for producing model webviews

Dave Barker pointed out last week that the webview of our simulink model files, generated from the installed models (i.e. in /opt/rtcds/caltech/c1/target/<system name>/simLink/) was not handling libraries properly.  Essentially the web pages generated couldn't see inside library parts.

This was caused by 2 problems.  The first being the userapps not being in the matlab path when the slwebview call was done, so it couldn't even find the libraries.  The second problem is the slwebview code by default doesn't follow libraries and links, and needs a special command to be told to do so.

I added the following lines to the webview_simlink_update.m file:

addpath('/opt/rtcds/caltech/c1/core/trunk/src/epics/simLink/lib')
for sub = {'cds','isc','isi','sus','psl'}
 for spath = {'common/models','c1/models/lib'}
   addpath(['/opt/rtcds/caltech/c1/userapps/release/' sub{1} '/' spath{1}]);
 end
end

I also changed the following:

temp = slwebview(final_files{x},'viewFile',false);

became

temp = slwebview(final_files{x},'viewFile',false,'FollowLinks','on','FollowModelReference','on');

After confirming these changes worked, I have sent a corrected version to Dave and Keith.

The webview results can be found at: https://nodus.ligo.caltech.edu:30889/FE/

 

 

  4961   Tue Jul 12 10:18:05 2011 JamieUpdateCDSC1:DAQ-FB0_C1???_STATUS indicators red, restored after controller restarts

Yesterday I found the C1:DAQ-FB0_C1???_STATUS lights to be red for the SUS, MCS, SCX, and SCY controllers.  I know this has something to do with model communication with the framebuilder, but I unfortunately don't remember exactly what it is.  I decided to try restarting the affected models to see if that cleared up the problem.  It did.  After restarting c1scx, c1scy, c1sus, and c1mcs everything came back up green.

We need some better documentation about what all of these status indicators mean.

  5006   Wed Jul 20 20:04:54 2011 JamieUpdateCDSC1:DAQ-FB0_C1XXX_STATUS sometimes unexplainably goes red

I have been noticing this happening occasionally, but I don't understand what is causing:

status-fb-red1.png

The channel in question above is C1:DAQ-FB0_C1SCX_STATUS.  This channel is (I believe) reporting some status of the front end model communication with the frame builder, but I'm not sure exactly what.

Usually this problem goes away when I restart the model or the frame builder, but it didn't work this time.  Tomorrow I will figure out what this channel means, why it's sporadically going red, and how to correct it.

  5030   Mon Jul 25 13:01:24 2011 kiwamuUpdateCDSc1ioo Make problem

[Suresh / Kiwamu]

HELP US Jamieeeeeeee !! We are unable to compile c1ioo.

 

It looks like something wrong with Makefile.

We ran make c1ioo -- this was successful every time. However make install-c1ioo doesn't run.

The below is the error messages we got.

        make install-target-c1ioo
        make[1]: Entering directory `/opt/rtcds/caltech/c1/core/branches/branch-2.1'
        Please make c1ioo first

Then we looked at Makefile and tried to find what was wrong. Then found the sentence (in 36th line from the top) saying

        if test $(site)no = no; then echo Please make $$system first; exit 1; fi;\

We thought the lack of the site-name specification caused the error.

So then we tried the compile it again with the site name specified by typing

     export site=c1

in the terminal window.

It went ahead a little bit further, but it still doesn't run all through the Make commands.

 

  5031   Mon Jul 25 13:09:39 2011 JamieUpdateCDSc1ioo Make problem

> It looks like something wrong with Makefile.

Sorry, this was my bad.  I was making a patch to the makefile to submit back upstream and I forgot to revert my changes.  I've reverted them now, so everything should be back to normal.

  5049   Wed Jul 27 15:49:13 2011 jamieConfigurationCDSdataviewer now working on pianosa

Not exactly sure what the problem was, but I updated to the head of the SVN and rebuilt and it seems to be working fine now.

  5060   Fri Jul 29 12:39:26 2011 jamieUpdateCDSc1iscex mysteriously crashed

c1iscex was behaving very strangely this morning.  Steve earlier reported that he was having trouble pulling up some channels from the c1scx model.  I went to investigate and noticed that indeed some channels were not responding.

While I was in the middle of poking around, c1iscex stopped responding altogether, and became completely unresponsive.  I walked down there and did a hard reset.  Once it rebooted, and I did a burt restore from early this morning, everything appeared to be working again.

The fact that problems were showing up before the machine crashed worries me.  I'll try to investigate more this afternoon.

  5094   Tue Aug 2 16:43:23 2011 jamieUpdateCDSNDS2 server on mafalda restarted for access to new channels

In order to get access to new DQ channels from the NDS2 server, the NDS2 server needs to be told about the new channels and restarted.  The procedure is as follows:

ssh mafalda
cd /users/jzweizig/nds2-mafalda
./build_channel_history
./install_channel_list
pkill nds2
# wait a few seconds for the process to quit and release the server port
./start_nds2

This procedure needs to be run every time new _DQ channels are added.

We need to set this up as a proper service, so the restart procedure is more elegant.

An additional comment from John Z.:

    The --end-gps parameter in ./build_channel_history seems to be causeing
    some trouble. It should work without this parameter, but there is a
    directory with a gps time of 1297900000 (evidently a test for GPS1G)
    that might screw up the channel list generation. So, it appears that
    the end time requires a time for which data already exists. this
    wouldn't seem to be a big deal, but it means that it has to be modified
    by hand before running. I haven't fixed this yet, but I think that I
    can probably pick out the most recent frame and use that as an end-time
    point. I'll see if I can make that work...

  5136   Mon Aug 8 00:12:58 2011 ranaUpdateCDSdiagonalization of MC input matrix

I've finally completed the SUS/peakFit/ scripts which find the new input matrix for the SUS. MC1, MC2, MC3, and ITMX have been matrix'd.

I tried to do the BS, but it came out with very funny matrix elements. Also the BS is missing its DAQ channels again (JAMIE !) so we can't diagnose it with the free swinging method.

To continue, we have to get some good data and try this again. Right now there are some weird issues with a lot of the optics. I've also set the damping gains for the optics with the new matrices.

 Ex.

new_matrix = findMatrix('ITMX')

writeSUSinmat('ITMX', new_matrix)

writeSUSinmat.m

this script writes the values to the MEDM input SUS matrix. To do the writing, I used the low level 'caput' command instead of ezcawrite since the ezca libraries are getting deprecated.

caput doesn't really have good diagnostics, so I use matlab to check the return status and then display to the terminal. You can just rerun it if it gives you an error.

 

 

A coupled of normalization notes:

1) The POS/PIT/YAW rows are scaled so that the mean of abs(FACE elements) = 1. Previously, I had the max element = 1.

2) The SIDE row is scaled so that the SIDE element = +1.

3) I then normalized the ROWS according to the geometrical factors that Jamie has calculated and almost put into the elog.

 

All these scripts have been added to the SVN. I've removed the large binary data files from the directory though. You can just rsync them in to your laptop if you want to run this stuff remotely.

  5137   Mon Aug 8 00:58:26 2011 ranaUpdateCDSdiagonalization of MC input matrix

Besides the purpose of correctly tuning the suspensions, my hidden goal in the input matrix diagonalization has been to figure out what the 'true' sensing noise of the OSEMs is so that we can accurately predict the noise impact on the OAF.

The attached plot shows the DOFs of ITMX calibrated into microns or microrad as per Jamie's ethereal input matrix calculations.

The main result is in the ratio of POS to BUTTER. It tells us that even at nighttime (when this data was taken) we should be able to get some reduction in the arms at 1 Hz.

Whether we can get anything down to 0.1 Hz depends on how the arm control signal compares to the POS signal here. I leave it to Jenne to overlay those traces using a recent Arm lock.

Attachment 1: null.png
null.png
  5143   Mon Aug 8 19:45:27 2011 jamieUpdateCDSactivateDQ script run; SUS channels being acquired again

> Also the BS is missing its DAQ channels again (JAMIE !) so we can't diagnose it with the free swinging method.

I'm not sure why the BS channels were not being acquired.  I reran the activateDQ script, which seemed to fix everything.  The BS DQ channels are now there.

I also noticed that for some reason there were SUS-BS-ASC{PIT,YAW}_IN1_DQ channels, even though they had their acquire flags set to 0.  This means that they were showing up like test point channels, but not being written to frames by the frame builder.  This is pretty unusual, so I'm not sure why they were there.  I removed them.

  5162   Wed Aug 10 00:21:10 2011 jamieUpdateCDSupdates to peakFit scripts

I updated the peakFit routines to make them a bit more user friendly:

  • modified so that any subset of optics can be processed at a time, instead of just all
  • broke out tweakable fit parameters into a separate parameters.m file
  • added a README that describes use

These changes were committed to the 40m svn.

  5211   Fri Aug 12 16:50:37 2011 YoichiConfigurationCDSFE Status screen rearranged
I rearranged the FE_STATUS.adl so that I have a space to add c1ffc in the screen.
So, please be aware that the FE monitors are no longer in their original positions
in the screen.
  5214   Fri Aug 12 17:27:49 2011 YoichiSummaryCDSToggle button for RCG
Bottom line: I made an RCG block to realize a toggle button easily.

Read on if you need such a button, or if you want to know how to
write a new RCG block with C.

-----------------
When I was making MEDM screens for FFC, I wanted to have a toggle
button to enable/disable the FFC path.
I wanted to have something like the ON/OFF buttons of the filter bank
screens, the one changes its state every time I click on it.
However, I could not find an easy way to realize that.

From MEDM, I can send a value to an EPICS channel using a "Message Button".
This value is always the same, say 1.
In the RCG model, I used a cdsEpicsMomentary block so that whenever the channel
gets 1, it stays to be 1 for a while and turns back to 0 in a second or so.
This generates a pulse of 1 when I click on a message button on a MEDM screen.
Then I needed a block to keep its internal state (0 or 1), and flips its state
whenever it receives a pulse of 1.
Since I couldn't find such a block in the current RCG library, I implemented one
using the cdsFunctionCall block. It allows you to implement a block with C code.

There is a good explanation of how to use this block in the CDS_PARTS library.
Here is basically what I did.

(1) Drag and drop thee cdsFunctionCall block to my model.

(2) In the "Block Properties", I put the following line in the Description field.
inline cdsToggle /opt/rtcds/caltech/c1/userapps/release/cds/common/src/cdsToggle.c
This means to call a function cdsToggle(), whose code is in the file indicated above.

(3) The contents of the source code is very simple.
void cdsToggle(double *in, int inSize, double *out, int outSize){
  static double x = 0;
  static double y = 0;

  if (*in != y){
    y = *in;
    if (y == 1){
      x = (x == 1) ? 0 : 1;
      *out = x;
    }
  }
}
The function prototype is always the same. *in and *out are the pointers to the arrays of doubles
for input and output signals of the block. In simuLink, the signals have to be
multiplexed so that the RCG can know how many signals are handed to or returned from the function.
In order to keep the internal state of my custom block, I used "static" keyword in the
declaration of the variables. The rest of the code should be obvious.

(4) Just compile the model as usual. The RCG will automatically include the source code and put
a call to the function in the proper place.

I made the block a library so that people can use it.
/opt/rtcds/caltech/c1/userapps/trunk/cds/common/models/cdsToggle.mdl
is the one.
For the usage of it, please have a look at
/opt/rtcds/caltech/c1/userapps/trunk/isc/c1/models/c1lsc
  5312   Sat Aug 27 15:47:59 2011 ranaUpdateCDSOSEM noise / nullstream and what does it mean for satellites

In the previous elog of mine, I looked at the nullstream (aka butterfly mode) to find out if the intrinsic OSEM noise is limiting the displacement noise of the interferometer or possibly the Wiener FF performance.

The conclusion was that its not above ~0.2 Hz. Due to the fortuitous breaking of the ITMX magnet, we also have a chance to check the 'bright noise': what the noise is with no magnet to occlude the LED beam.

As expected, the noise spectra with no magnets is less than the calculated nullstream. The attached plot shows the comparison of the LL OSEM (all the bright spectra look basically alike) with the damped

optic spectra from 1 month week ago.

From 0.1 - 10 Hz, the motion is cleanly larger than the noise. Below ~0.2 Hz, its possible that the common mode rejection of the short cavity lengths are ruined by this. We should try to see if the low frequency

noise in the PRC/SRC is explainable with our current knowledge of seismicity and the 2-dimensional 2-poiint correllation functions of the ground.

So, the question is, "Should we try to upgrade the satellite boxes to improve the OSEM sensing noise?"

Attachment 1: Untitled.png
Untitled.png
  5315   Sun Aug 28 22:49:40 2011 SureshUpdateCDSfb down

I recompiled c1ioo after making some changes and restarted fb. (about 9:45 - 10PM PDT)  But it failed to restart.  It responds to ping, but does not allow a ssh or telnet. The screen output is:

allegra:~>ssh fb
ssh: connect to host fb port 22: Connection refused
allegra:~>telnet fb 8087
Trying 192.168.113.202...
telnet: connect to address 192.168.113.202: Connection refused
telnet: Unable to connect to remote host: Connection refused
allegra:~>
 

Nor am I able to connect to c1ioo either....

 

 

  5316   Mon Aug 29 00:49:00 2011 kiwamuUpdateCDSRe : fb down

Fb is in a bad situation. It needs a MANUAL fsck to fix the file system.

HELP US, Jamieeeeeeeeeeee !!!

 

When Suresh and I connected a display and tried to see what was going on, the fb computer was in a file system check.

This was because Suresh did a hardware reboot by pressing a power button on the front panel.

Since the file checking took so long time and didn't proceed fast, we pressed the reset button and again the power button.

Actually the reset button didn't work (maybe ?) it just made some light indicators flashing.

After the second reboot the reboot message said that it needs a manual fsck to fix the file system. This maybe because we interrupted the file checking.

We are leaving it to Jamie because the fsck command would do something bad if unfamiliar persons, like us, do it.

 

In addition to it, the boot message was also saying that line 37 in /etc/fstab was bad.

We logged into the machine with a safe mode, then found there was an empty line in 37th line of fstab.

We tried erasing this empty line, but failed for some reasons. We were able to edit it by using vi, but wasn't able to save it.

  5317   Mon Aug 29 12:05:32 2011 jamieUpdateCDSRe : fb down

fb was requiring manual fsck on it's disks because it was sensing filesystem errors.  The errors had to do with the filesystem timestamps being in the future.  It turned out that fb's system date was set to something in 2005.  I'm not sure what caused the date to be so off (motherboard battery problem?)  But I did determine after I got the system booting that the NTP client on fb was misconfigured and was therefore incapable of setting the system date.  It seems that it was configured to query a non-existent ntp server.  Why the hell it would have been set like this I have no idea.

In any event, I did a manual check on /dev/sdb1, which is the root disk, and postponed a check on /dev/sda1 (the RAID mounted at /frames) until I had the system booting.  /dev/sda1 is being checked now, since there are filesystems errors that need to be corrected, but it will probably take a couple of hours to complete.  Once the filesystems are clean I'll reboot fb and try to get everything up and running again.

  5319   Mon Aug 29 18:16:10 2011 jamieUpdateCDSRe : fb down

fb is now up and running, although the /frames raid is still undergoing an fsck which is likely take another day.  Consequently there is no daqd and no frames are being written to disk.  It's running and providing the diskless root to the rest of the front end systems, so, so the rest of the IFO should be operational.

I burt restored the following (which I believe is everything that was rebooted), from Saturday night:

/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1lscepics.snap
/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1susepics.snap
/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1iooepics.snap
/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1assepics.snap
/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1mcsepics.snap
/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1gcvepics.snap
/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1gfdepics.snap
/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1rfmepics.snap
/opt/rtcds/caltech/c1/burt/autoburt/snapshots/2011/Aug/27/23:07/c1pemepics.snap

 

  5323   Tue Aug 30 11:28:56 2011 jamieUpdateCDSframebuilder back up

The fsck on the framebuilder (fb) raid array (/dev/sda1) completed overnight without issue.  I rebooted the framebuilder and it came up without problem.

I'm now working on getting all of the front-end computers and models restarted and talking to the framebuilder now.

  5324   Tue Aug 30 11:42:29 2011 jamieUpdateCDStestpoint.par file found to be completely empty

The testpoint.par file, located at /opt/rtcds/caltech/c1/target/gds/param/testpoint.par, which tells GDS processes where to find the various awgtpman processes, was completely empty.  The file was there but was just 0 bytes.  Apparently the awgtpman processes themselves also consult this file when starting, which means that none of the awgtpman processes would start.

This file is manipulated in the "install-daq-%" target in the RCG Makefile, ultimately being written with output from the src/epics/util/updateTestpointPar.pl script, which creates a stanza for each front-end model.  Rebuilding and installing all of the models properly regenerated this file.

I have no idea what would cause this file to get truncated, but apparently this is not the first time: elog #3999.  I'm submitting a bug report with CDS.

 

  5325   Tue Aug 30 14:33:52 2011 jamieUpdateCDSall front-ends back up and running

All the front-ends are now running.  Many of them came back on their own after the testpoint.par was fixed and the framebuilder was restarted.  Those that didn't just needed to be restarted manually.

The c1ioo model is currently in a broken state: it won't compile.  I assume that this was what Suresh was working on when the framebuilder crash happened.  This model needs to be fixed.

  5408   Wed Sep 14 20:04:05 2011 jamieUpdateCDSUpdate to frame builder wiper.pl script for GPS 1000000000

I have updated the wiper.pl script (/opt/rtcds/caltech/c1/target/fb/wiper.pl) that runs on the framebuilder (in crontab) to delete old frames in case of file system overloading.  The point of this script is to keep the file system from overloading by deleting the oldest frames.  As it was, it was not properly sorting numbers which would have caused it to delete post-GPS 1000000000 frames first.  This issue was identified at LHO, and below is the patch that I applied to the script.


--- wiper.pl.orig  2011-04-11 13:54:40.000000000 -0700
+++ wiper.pl       2011-09-14 19:48:36.000000000 -0700
@@ -1,5 +1,7 @@
 #!/usr/bin/perl
 
+use File::Basename;
+
 print "\n" .  `date` . "\n";
 # Dry run, do not delete anything
 $dry_run = 1;
@@ -126,14 +128,23 @@
 
 if ($du{$minute_trend_frames_dir} > $minute_frames_keep) { $do_min = 1; };
 
+# sort files by GPS time split into prefixL-T-GPS-sec.gwf
+# numerically sort on 3rd field
+sub byGPSTime {
+    my $c = basename $a;
+    $c =~ s/\D+(\d+)\D+(\d+)\D+/$1/g;
+    my $d = basename $b;
+    $d =~ s/\D+(\d+)\D+(\d+)\D+/$1/g;
+    $c <=> $d;
+}
+
 # Delete frame files in $dir to free $ktofree Kbytes of space
 # This one reads file names in $dir/*/*.gwf sorts them by file names
 # and progressively deletes them up to $ktofree limit
 sub delete_frames {
        ($dir, $ktofree) = @_;
        # Read file names; Could this be inefficient?
-       @a= <$dir/*/*.gwf>;
-       sort @a;
+       @a = sort byGPSTime <$dir/*/*.gwf>;
        $dacc = 0; # How many kilobytes we deleted
        $fnum = @a;
        $dnum = 0;
@@ -145,6 +156,7 @@
          if ($dacc >= $ktofree)  { last; }
          $dnum ++;
          # Delete $file here
+         print "- " . $file . "\n";
          if (!$dry_run) {     
            unlink($file);
          }

  5424   Thu Sep 15 20:16:15 2011 jamieUpdateCDSNew c1oaf model installed and running

[Jamie, Jenne, Mirko]

New c1oaf model installed

We have installed the new c1oaf (online adaptive feed-forward) model.  This model is now running on c1lsc.  It's not really doing anything at the moment, but we wanted to get the model running, with all of it's interconnections to the other models.

c1oaf has interconnections to both c1lsc and c1pem via the following routes:

c1lsc ->SHMEM-> c1oaf
c1oaf ->SHMEM-> c1lsc
c1pem ->SHMEM-> c1rfm ->PCIE-> c1oaf

Therefore c1lsc, c1pem, and c1rfm also had to be modified to receive/send the relevant signals.

As always, when adding PCIx senders and receivers, we had to compile all the models multiple times in succession so that the /opt/rtcds/caltech/c1/chans/ipc/C1.ipc would be properly populated with the channel IPC info.

Issues:

There were a couple of issues that came up when we installed and re/started the models:

c1oaf not being registered by frame builder

When the c1oaf model was started, it had no C1:DAQ-FB0_C1OAF_STATUS channel, as it's supposed to.  In the daqd log (/opt/rtcds/caltech/c1/target/fb/logs/daqd.log.19901) I found the following:

Unable to find GDS node 22 system c1oaf in INI files

It turns out this channel is actually created by the frame builder, and it could not find the channel definition file for the new model, so it was failing to create the channels for it.  The frame builder "master" file (/opt/rtcds/caltech/c1/target/fb/master) needs to list the c1oaf daq ini files:

/opt/rtcds/caltech/c1/chans/daq/C1OAF.ini
/opt/rtcds/caltech/c1/target/gds/param/tpchn_c1oaf.par

These were added, and the framebuilder was restarted.  After which the C1:DAQ-FB0_C1OAF_STATUS appeared correctly.

SHMEM errors on c1lsc and c1oaf

This turned out to be because of an oversight in how we wired up the skeleton c1oaf model.  For the moment the c1oaf model has only the PCIx sends and receives.  I had therefore grounded the inputs to the SHMEM parts that were meant to send signals to C1LSC.  However, this made the RCG think that these SHMEM parts were actually receivers, since it's the grounding of the inputs to these parts that actually tells the RCG that the part is a receiver.  I fixed this by adding a filter module to the input of all the senders.

Once this was all fixed, the models were recompiled, installed, and restarted, and everything came up fine.

All model changes were of course committed to the cds_user_apps svn as well.

  5426   Thu Sep 15 21:56:01 2011 MirkoUpdateCDSc1oaf check, possible shmem problem

After Jamie installed the c1oaf model ( entry 5424 ) I went and checked the intermodel communication.

Remember the config is:

c1lsc ->SHMEM-> c1oaf
c1oaf ->SHMEM-> c1lsc
c1pem ->SHMEM-> c1rfm ->PCIE-> c1oaf

I checked at least one of every communications type.

-All signals reach their destinations.
-c1lsc_to_c1oaf_via_shmem is more noisy adding noise to the signal. lsc runs at 16kHz and oaf at 2kHz but that should actually smooth things out.

c1lsc_to_c1oaf_via_shmem.png

 

Attachment 1: c1lsc_to_c1oaf_via_shmem.png
c1lsc_to_c1oaf_via_shmem.png
Attachment 2: c1oaf_to_c1lsc_via_shmem_fixed_sine_inj_at_100Hz.png
c1oaf_to_c1lsc_via_shmem_fixed_sine_inj_at_100Hz.png
Attachment 3: c1oaf_to_c1lsc_via_shmem_white_noise_inj.png
c1oaf_to_c1lsc_via_shmem_white_noise_inj.png
Attachment 4: c1pem_to_c1oaf_via_rfm.png
c1pem_to_c1oaf_via_rfm.png
  5486   Tue Sep 20 17:45:30 2011 kiwamuUpdateCDSdaqd is restarting by hisself ?

[Jenne / Kiwamu]

 Fb was sick. Dataviewer and Fourier Tools didn't work for a while.

After 10 minutes later they became healthy again. No idea what exactly was going on.

One thing we found was that : during the sickness of fb, it looks like daqd was restarting by hisself. Is this normal ??

Here is the bottom sentences of restart.log. Apparently daqd was rebooting although we didn't command to do so.

  daqd_start Tue Sep 20 02:41:17 PDT 2011
  daqd_start Tue Sep 20 13:18:12 PDT 2011
  daqd_start Tue Sep 20 17:33:00 PDT 2011

  5535   Sat Sep 24 01:38:14 2011 kiwamuUpdateCDSc1scx and c1x01 restarted

[Koji / Kiwamu]

 The c1scx and c1x01 realtime processes became frozen. We restarted them around 1:30 by sshing and running the kill/start scripts.

  5561   Wed Sep 28 02:42:04 2011 kiwamuUpdateCDSsome DAQ channel lost in c1sus : fb, c1sus and c1pem restarted

Somehow some DAQ channels for C1SUS have disappeared from the DAQ channel list.

Indeed there are only a few DAQ channels listed in the C1SUS.ini file.

I ran the activateDQ.py and restarted daqd.

Everything looks okay.  C1SUS and C1PEM were restarted because they became frozen.

  5579   Fri Sep 30 02:56:56 2011 kiwamuUpdateCDSC1IOO.ini and C1LSC.ini files reverted

[Suresh/Kiwamu]

We found that the C1LSC.ini and C1IOO.ini file had been refreshed and there were a few recorded channels in the files.

So we manually recovered C1LSC.ini file using the daqconfig GUI screen.

For the C1IOO.ini file we simply replaced it by the archived one which had been saved in 22nd of September.

Then we restarted daqd.

  5580   Fri Sep 30 03:14:18 2011 kiwamuUpdateCDSsuspension became crazy : c1sus rebooted

Quote from #5579

Then we restarted daqd.

[Suresh / Kiwamu]

The c1lsc and c1sus machine were rebooted.

 

- - (CDS troubles)

 After we restarted daqd and pressed some DAQ RELOAD buttons the c1lsc machine crashed.

The machine didn't respond to ssh, so the machine was physically rebooted by pressing the reset button.

Then we found all the realtime processes on the c1sus machine became frozen, so we restarted them by sshing and typing the start scripts.

However after that, the vertex suspensions became undamped, even though we did the burt restore correctly.

This symptom was exactly the same as Jenne reported (#5571).

We tried the same technique as Jenne did ; hardware reboot of the c1sus machine. Then everything became okay.

The burt restore was done for c1lsc, c1asc, c1sus and c1mcs.

 

- - (ITMX trouble)

During the trial of damping recovery, the ITMX mirror seemed stacked to an OSEM. The UL readout became zero and the rest of them became full range.

Eventually introducing a small offset in C1:SUS-ITMX_YAW_COMM released the mirror. The amount of the offset we introduced was about +1.

  5607   Mon Oct 3 20:47:51 2011 kiwamuUpdateCDSc1lsc and c1sus didn't run

[Mirko / Jenne / Kiwamu]

Just a quick update. All the realtime processes on the c1lsc and c1sus machine didn't run at all.

Somehow the c1xxxfe.ko kernel module, where xxx is x04, x02, lsc, ass, sus, mcs, pem and rfm failed to be insmod.

The timing indicators on the c1lsc and c1sus machine are saying NO SYNC.

 

- According to log files (target/c1lsc/logs/log.txt)

insmod: error inserting '/opt/rtcds/caltech/c1/target/c1lsc/bin/c1lscfe.ko': -1 Unknown symbol in module

- dmesg on c1lsc (c1sus also dumps the same error message):

[   45.831507] DXH Adapter 0 : sci_map_segment - Failed to map segment - error=0x40000d01
[   45.833006] c1x04: DIS segment mapping status 1073745153

DXH dapter is a part of the Dolphine connections.

When a realtime codes is waking up, the code checks the Dolphin connections.

The checking procedure is defined by dolphin.c (/src/fe/doplhin.c).

According to a printk sentence in dolphin.c the second error message listed above will return status "0" if everything is fine.

The first error above is an error vector from a special dolphin's function called sci_map_segment, which is called in dolphin.c.

So something failed in this sci_map_segment function and is preventing the realtime code from waking up.

Note that sci_map_segment is defined in genif.h and genif.c which reside in /opt/srcdis/src/IRM_DSX/drv/src.

  5608   Mon Oct 3 21:20:30 2011 JenneUpdateCDSc1lsc and c1sus didn't run

[Jenne, Mirko, Kiwamu, Koji, and Jamie by phone]

We just got off the phone with Jamie.  In addition to all the stuff that Kiwamu mentioned, Mirko reverted the c1oaf model and C-code to stuff that was working successfully on Friday (using "svn export, rev # 1134) since that's what we were working on when all hell broke loose.

We did a few rounds of "sudo shutdown -h now" on c1lsc and c1sus machines, and pulled the power cords out.  

We also switched the c1ioo and c1lsc 1PPS fibers in the fanout chassis, to see if that would fix the problem.  Nope.  c1ioo is still fine, and c1lsc is still not fine.

Still getting "No Sync".

We're going to call in Alex in the morning, if we can't figure it out soon.

  5609   Mon Oct 3 23:52:49 2011 kiwamuUpdateCDSsome more tests for the Dolphin

[Koji / Kiwamu]

 We did several tests to figure out what could be a source of the computer issue.

The Dolphin switch box looks suspicious, but not 100% sure.

 

(what we did)

 + Removed the pciRfm sentence from the c1x04 model to disable the Dolphin connection in the software.

 + Found no difference in the Makefile, which is supposed to comment out the Dolphin connection sentences.

   ==> So we had to edit the Makefile by ourselves

 + Did a hand-comilpe by editing the Makefile and running a make command.

 + Restarted the c1x04 process and it ran wihtout problems.

   ==> the Dolphin connection was somehow preventing the c1x04 process from runnning.

 +  Unplugged the Dolphin cables on the back side of the Dolphin box and re-plug them to other ports.

   ==> didn't improve the issue.

 + During those tests, c1lsc frequently became frozen. We disabled the automatic-start of c1lsc, c1ass, c1oaf by editting rtsystab.

  ==> after the test we reverted it.

 + We reverted all the things to the previous configuration.

  5610   Tue Oct 4 07:51:36 2011 steveUpdateCDSc1lsc and c1sus are still down

 

 c1lsc and c1sus are still down. Only ETMX and ETMY are damped

  5611   Tue Oct 4 10:35:08 2011 MirkoUpdateCDSc1lsc and c1sus running again

[Alex, Mirko]

Alex fixed the computers this morning. It was in fact a dolphin problem:

Hi Jenne,  figured it out. Even though dxadmin said the Dolphin net was fine, it wasn't. Something happeneed to DIS networkmanager and I had to restart it. It is running on fb: 
controls@fb ~ $ ps -e | grep dis 12280 ?        00:00:00 dis_networkmgr
controls@fb ~ $ sudo /etc/init.d/dis_networkmgr restart
Once the restart was done both c1lsc and c1sus nodes were configured correctly, they printed the usual "node 12 is OK" "node 8 is OK" messages into the dmesg and was able to run /etc/start_fes.sh on lsc and sus to load all the FEs.  Alex

Some lights on c1lsc were still red: C1:DAQ-FBO_C1SYS_SYS and the smaller red light left of it. Restarted the fb. Didn't help. Restarted c1lsc, all green now.
Restored autoburt from Oct 3. 19:07 on c1lsc and c1sus.
  5621   Wed Oct 5 14:18:09 2011 kiwamuUpdateCDSsome DAQ channel lost in c1sus : fb, c1sus and c1pem restarted

I found again the ini files had been refreshed.

I ran the activateDQ.py script (link to the script wiki page) and restarted the daqd process on fb.

The activateDQ.py script should be included into the recompile or rebuild scripts so that we don't have to run the script everytime by hands.

I am going to add this topic on the CDS todo list (wiki page).

Quote from #5561

Somehow some DAQ channels for C1SUS have disappeared from the DAQ channel list.

 

  5663   Thu Oct 13 21:44:48 2011 MirkoUpdateCDSSeismic BLRMS channels, new RMS calculation

[Rana, Koji, Mirko]

We looked into the CDS RMS block c-code as described in Rolfs RCG app guide. Seems the block uses a first order LP filter with a corner freq. / time of 20k execution cycles. There are also some weird thersholds at +-2000counts in there.

I was looking into implementing a hand-made RMS block, by squaring, filtering, rooting. The new RMS (left) seems nicer than the old one (bottom right). Signal was 141counts sinus at 4Hz.

Filters used: Before squaring: 4th order butterworth BP at given freq. & (new) 6th order inverse Chebyshew 20dB at 0.9*lower BP freq. and 1.1*upper BP freq. => about 1dB at BP freq.

                       After squaring: 4th order butterworth LP @ 1Hz.

C1PEM execution time increased from about 20us to about 45us.

Made a new medm screen with the respective filters in place of the empty C1PEM_OVERVIEW. Should go onto the sitemap.

New_RMS_vs_old_RMS.png

Original RMS LP is slower than 0.1Hz, see below for single LP at 0.1Hz in the new RMS. Original RMS is faster than single LP @ 0.01Hz

Original_RMS_LP_slower_than_0.1Hz.png

Some of the channels are recorded as 256Hz DAQ channels now. Need to figure out how to record these as 16Hz EPICS channls.

  5676   Mon Oct 17 10:43:14 2011 MirkoUpdateCDSCommited changes to c1rfm

I want to make changes to c1rfm. Found uncommited changes to it from Sept 27. Since we recompiled it since then it should be safe to commit them, so I did. See svn log for details.

  5677   Mon Oct 17 11:06:31 2011 MirkoUpdateCDSPiping data from c1lsc to c1oaf

Changed, recompiled, installed and restarted c1rfm and c1oaf to get the MC1-3 Pitch and Yaw data into the c1oaf model.
Also changed c1oaf to use MCL as a witness channel (as well as an actuator).
Added the changes to svn.

  5679   Mon Oct 17 14:26:22 2011 MirkoUpdateCDSSeismic BLRMS channels, new RMS calculation

Quote:

[Rana, Koji, Mirko]

We looked into the CDS RMS block c-code as described in Rolfs RCG app guide. Seems the block uses a first order LP filter with a corner freq. / time of 20k execution cycles. There are also some weird thersholds at +-2000counts in there.

I was looking into implementing a hand-made RMS block, by squaring, filtering, rooting. The new RMS (left) seems nicer than the old one (bottom right). Signal was 141counts sinus at 4Hz.

Filters used: Before squaring: 4th order butterworth BP at given freq. & (new) 6th order inverse Chebyshew 20dB at 0.9*lower BP freq. and 1.1*upper BP freq. => about 1dB at BP freq.

                       After squaring: 4th order butterworth LP @ 1Hz.

C1PEM execution time increased from about 20us to about 45us.

Made a new medm screen with the respective filters in place of the empty C1PEM_OVERVIEW. Should go onto the sitemap.

New_RMS_vs_old_RMS.png

Original RMS LP is slower than 0.1Hz, see below for single LP at 0.1Hz in the new RMS. Original RMS is faster than single LP @ 0.01Hz

Original_RMS_LP_slower_than_0.1Hz.png

Some of the channels are recorded as 256Hz DAQ channels now. Need to figure out how to record these as 16Hz EPICS channls.

 Channels are now going into EPICS channels (e.g. C1:PEM-ACC1_RMS_1_3 ). Adapted the PEM_SLOW.ini file. Channels don't yet show up in dataviewer. Probably due to other C1PEM maschine

  5695   Wed Oct 19 12:06:26 2011 MirkoUpdateCDSIncluded the MC servo channel in CDS

[Jamie, Mirko]

Included the 'Servo' output from the D040180 in c1ioo, which I hoped would be a better measure of the MC length fluctuations. It goes into ADC6, labeled CH7 on the physical board.
Servo-output => C1:IOO-MC_SERVO. (Already present is Out1-output => C1:IOO-MC_F).
At low freq. the servo signal is about 4.5dB bigger. Both are recorded at 256Hz now which is the reason for the downward slope at about 100Hz.

MC_F_versus_MC_SERVO.png

Coh_MC_F_MC_SERVO.png

  5702   Wed Oct 19 16:53:38 2011 kiwamuUpdateCDSsome screens need labels

Untitled.png

Some of the sub-suspension screens need labels to describe what those row and column are.

  5727   Fri Oct 21 18:20:54 2011 MirkoUpdateCDSFirst OAF version running

[Jenne, Jamie, Mirko]

We got the first version of the oaf code based on Matt"s code running!! :-)
Produces already data for e.g. MICH DOF. But don"t trust that. It's only 10 taps long and delay is not adjusted.

  5731   Mon Oct 24 20:00:21 2011 MirkoUpdateCDSTiny little scripts

Located in /opt/rtcds/caltech/c1/userapps/release/cds/common/scripts

Script 1: Diagreset.sh
Hits the diag reset buttons on the models on c1lsc and c1sus computers.

Script 2: Burtrest.sh
Restores the burt files from "today" 4am. Use a text editor if you want to change the times.

  5736   Tue Oct 25 18:09:44 2011 jamieUpdateCDSNew DEMOD part

I forgot to elog (bad Jamie) that I broke out the demodulator from the LOCKIN module to make a new DEMOD part:

DEMOD.png

The LOCKIN part now references this part, and the demodulator can now be used independently.  The 'LO SIN in' and 'LO COS in' should receive their input from the SIN and COS outputs of the OSCILLATOR part.

  5755   Fri Oct 28 12:47:38 2011 jamieUpdateCDSCSS/BOY installed on pianosa

I've installed Control System Studio (CSS) on pianosa, from the version 3.0.2 Red Hat binary zip.  It should be available as "css" from the command line.

CSS is a new MEDM replacement. It's output is .opi files, instead of .adl files.  It's supposed to include some sort of converter, but I didn't play with it enough to figure it out.

Please play around with it and let me know if there are any issues.

links:

ELOG V3.1.3-