ID |
Date |
Author |
Type |
Category |
Subject |
13468
|
Thu Dec 7 22:24:04 2017 |
johannes | Omnistructure | Computers | Acromag XEND progress |
Quote: |
- Need to calibrate the +/- 10V swing of the analog channels via the USB utility, but that requires wiring the channels to the connectors and should probably be done once the unit sits in the rack
- Need to wire power from the Sorensens into the chassis. There are +/- 5V, +/- 15V and +/- 20V present. The Acromags need only +12V-32V, for which I plan to use the +20V, and an excitation voltage for the binary channels, for which I'm going to wire the +5V. Should do this through the fuse rails on the side.
- The current slow binary channels are sinking outputs, same as the XT1111 16-channel module we have. The additional 4 binary outputs of the XT1541 are sourcing, and I'm currently not sure if we can use them with the sos driver and whitening vme boards that get their binary control signals from the slow system.
- Confirm switching of binary channels (haven't used model XT1111 before, but I assume the definitions are identical to XT1121)
- Setup remaining essential EPICS channels and confirm that dimensions are the same (as in both give the same voltage for the same requested value)
- Disconnect DIN cables, attach adapter boards + DSUB cables
- Testing
|
Getting the chassis ready took a little longer than anticipated, mostly because I had not looked into the channel list myself before and forgot about Lydia's post which mentions that some of the switching controls have to be moved from the fast to the slow DAQ. We would need a total of 5+5+4+8=22 binary outputs. With the existing Acromag units we have 16 sinking outputs and 8 sourcing outputs. I looked through all the Eurocrate modules and confirmed that they all use the same switch topology which has sourcing inputs.

While one can use a pull-down resistor to control a sourcing input with a sourcing output,

pulling down the MAX333A input (datasheet says logic low is <0.8V) requires something like 100 Ohms for the pull down resistor, which would require ~150mA of current PER CHANNEL, which is unreasonable. Instead, I asked Steve to buy a second XT1111 and modified the chassis to accomodate more Acromag units.
I have now finished wiring the chassis (except for 8 remaining bypass controls to the whitening board which need the second XT1111), calibrated all channels in use, confirmed all pin locations via the existing breakout boards and DCC drawings for the eurocrate modules, and today Steve and I added more fuses to the DIN rail power distribution for +20V and +15V.
There was not enough contingent free space in the XEND rack to mount the chassis, so for now I placed it next to it.

c1auxex2 is currently hosting all original physical c1auxex channels (not yet calc records) under their original name with an _XT added at the end to avoid duplicate channel names. c1auxex is still in control of ETMX. All EPICS channels hosted by c1auxex2 are in dimensions of Volts. The plan for tomorrow is to take c1auxex off the grid, rename the c1auxex2 hosted channels and transfer ETMX controls to it, provided we can find enough 37pin DSub cables (8). I made 5 adapter boards for the 5 Eurocrate modules that need to talk to the slow DAQ through their backplane connector. |
13469
|
Fri Dec 8 12:06:59 2017 |
johannes | Omnistructure | Computers | c1auxex2 ready - but need more cables | The new slow machine c1auxex2 is ready to deploy. Unfortunately we don't have enough 37pin DSub cables to connect all channels. In fact, we need a total of 8, and I found only three male-male cables and one gender changer. I asked Steve to buy more.
Over the past week I have transferred all EPICS records - soft channels and physical ones - from c1auxex to c1auxex2, making changes where needed. Today I started the in-situ testing
- Unplugged ETMX's satellite box
- Unplugged the eurocrate backplane DIN cables from the SOS Driver and QPD Whitening filter modules (the ones that receive ao channels)
- Measured output voltages on the relevant pins for comparison after the swap
- Turned off c1auxex by key, removed ethernet cable
- Started the modbus ioc on c1auxex2
- Slow machine indicator channels came online, ETMX Watchdog was responsive (but didn't have anything to do due to missing inputs) and reporting. PIT/YAW sliders function as expected
- Restoring the previous settings gives output voltages close to the previous values, in fact the exact values requested (due to fresh calibration)
- Last step is to go live with c1auxex2 and confirm the remaining channels work as expected.
I copied the relevant files to start the modbus server to /cvs/cds/caltech/target/c1auxex2, although kept local copies in /home/controls/modbusIOC/ from which they're still run.
I wonder what's the best practice for this. Probably to store the database files centrally and load them over the network on server start? |
14172
|
Tue Aug 21 03:09:59 2018 |
johannes | Omnistructure | DAQ | Panels for Acromag DAQ chassis | I expanded the previous panels to 6U height for the new DAQ chassis we're buying for the upgrade. I figure it's best if we stick to the modular design, so I'm showing a panel for 8 BNC connectors as an example. The front panel has 12 slots, the back has 10 plus power connectors, switches, and the ethernet plug.
I moved the power switch to the rear because it's a waste of space to put it in the front, and it's not like we're power cycling this thing all the time. Note that the unit only requires +24V (for general operation, +20V also does the trick, as is the situation for ETMX) and +15V (excitation field for the binary I/O modules). While these could fit into a single CONEC power connector, it's probably for the better if we don't make a version that supplies a large positive voltage where negative is expected, so I put in two CONEC plugs for +/- 15 and +/- 24.
I want to order 5-6 of these as soon as possible, so if anyone wants anything changed or sees a problem, please do tell! |
14278
|
Tue Nov 6 19:41:46 2018 |
Jon | Omnistructure | | c1vac1/2 replacement | This afternoon I started setting up the Supermicro 5017A-EP that will replace c1vac1/2. Following Johannes's procedure in 13681 I installed Debian 8.11 (jessie). There is a more recent stable release, 9.5, now available since the first acromag machine was assembled, but I stuck to version 8 for consistency. We already know that version to work. The setup is sitting on the left side of the electronics bench for now. |
14282
|
Wed Nov 7 19:17:18 2018 |
Jon | Omnistructure | | modbusIOC is running on c1vac replacement | Today I finished setting up the server that will replace the c1vac1/2 machines. I put it on the martian network at the unassigned IP 192.168.113.72. I assigned it the hostname c1vac and added it to the DNS lookup tables on chiara.
I created a new targets directory on the network drive for the new machine: /cvs/cds/caltech/target/c1vac. After setting EPICS environment environment variables according to 13681 and copying over (and modifiying) the files from /cvs/cds/caltech/target/c1auxex as templates, I was able to start a modbusIOC server on the new machine. I was able to read and write (soft) channel values to the EPICS IOC from other machines on the martian network.
I scripted it as a systemd-managed process which automatically starts on boot and restarts after failure, just as it is set up on c1auxex. |
14287
|
Fri Nov 9 22:24:22 2018 |
Jon | Omnistructure | | Wiring of Vacuum Acromag Chassis Complete | Wiring of the power, Ethernet, and indicator lights for the vacuum Acromag chassis is complete. Even though this crate will only use +24V DC, I wired the +/-15V connector and indicator lights as well to conform to the LIGO standard. There was no wiring diagram available, so I had to reverse-engineer the wiring from the partially complete c1susaux crate. Attached is a diagram for future use. The crate is ready to begin software developing on Monday. |
14296
|
Wed Nov 14 21:34:44 2018 |
Jon | Omnistructure | | Vacuum Acromags installed and tested | All 7 Acromag units are now installed in the vacuum chassis. They are connected to 24V DC power and Ethernet.
I have merged and migrated the two EPICS databases from c1vac1 and c1vac2 onto the new machine, with appropriate modifications to address the Acromags rather than VME crate.
I have tested all the digital output channels with a voltmeter, and some of the inputs. Still more channels to be tested.
I’ll follow up with a wiring diagram for channel assignments. |
14308
|
Mon Nov 19 22:45:23 2018 |
Jon | Omnistructure | | Vacuum System Subnetwork | I've set up a closed subnetwork for interfacing the vacuum hardware (Acromags and serial devices) with the new controls machine (c1vac; 192.168.113.72). The controls machine has two Ethernet interfaces, one which faces outward into the martian network and another which faces the internal subnetwork, 192.168.114.xxx. The second network interface was configured via the following procedure.
1. Add the following lines to /etc/network/interfaces:
allow-hotplug eth1
iface eth1 inet static
address 192.168.114.9
netmask 255.255.255.0
2. Restart the networking services:
$sudo /etc/init.d/networking restart
3. Enable DNS lookup on the martian network by adding the following lines to /etc/resolv.conf:
search martian
nameserver 192.168.113.104
4. Enable IP forwarding from eth1 to eth0:
$sudo echo 1 > /proc/sys/net/ipv4/ip_forward
5. Configure IP tables to allow outgoing connections, while keeping the LAN invisible from outside the gateway (c1vac):
$sudo iptables -t nat -A POSTROUTING -o eth0 -j MASQUERADE
$sudo iptables -A FORWARD -i eth0 -o eth1 -m state --state RELATED,ESTABLISHED -j ACCEPT
$sudo iptables -A FORWARD -i eth1 -o eth0 -j ACCEPT
6. Finally, because the EPICS 3.14 server binds to all network interfaces, client applications running on c1vac now see two instances of the EPICS server---one at the outward-facing address and one at the LAN address. To resolve this ambiguity, two additional enviroment variables must be set that specify to local clients which server address to use. Add the following lines to /home/controls/.bashrc:
EPICS_CA_AUTO_ADDR_LIST=NO
EPICS_CA_ADDR_LIST=192.168.113.72
A list of IP addresses so far assigned on the subnetwork follows.
Device |
IP Address |
Acromag XT1111a |
192.168.114.1 |
Acromag XT1111b |
192.168.114.2 |
Acromag XT1111c |
192.168.114.3 |
Acromag XT1111d |
192.168.114.4 |
Acromag XT1111e |
192.168.114.5 |
Acromag XT1121a |
192.168.114.6 |
Acromag XT1121b |
192.168.114.7 |
Perle IOLAN SDS16 |
192.168.114.8 |
c1vac |
192.168.114.9 |
|
14309
|
Mon Nov 19 23:38:41 2018 |
Jon | Omnistructure | | Vacuum Acromag Channel Assignments | I've completed bench testing of all seven vacuum Acromags installed in a custom rackmount chassis. The system contains five XT1111 modules (sinking digital I/O) used for readbacks of the state of the valves, TP1, CP1, and the RPs. It also contains two XT1121 modules (sourcing digital I/O) used to pass 24V DC control signals to the AC relays actuating the valves and RPs. The list of Acromag channel assignments is attached.
I tested each input channel using a manual flip-switch wired between signal pin and return, verifying the EPICS channel readout to change appropriately when the switch is flipped open vs. closed. I tested each output channel using a voltmeter placed between signal pin and return, toggling the EPICS channel on/off state and verifying the output voltage to change appropriately. These tests confirm the Acromag units all work, and that all the EPICS channels are correctly addressed. |
14315
|
Sun Nov 25 17:41:43 2018 |
Jon | Omnistructure | | Vacuum Controls Upgrade - Status and Plans | New hardware has been installed in the vacuum controls rack. It is shown in the below post-install photo.
- Supermicro server (c1vac) which will be replacing c1vac1 and c1vac2.
- 16-port Ethernet switch providing a closed local network for all vacuum devices.
- 16-port IOLAN terminal server for multiplexing/Ethernetizing all RS-232 serial devices.
Below is a high-level summary of where things stand, and what remains to be done.
Completed:
✔ Set up of replacement controls server (c1vac).
- Supermicro 1U rackmount server, running Debian 8.5.
- Hosting an EPICS modbus IOC, scripted to start/restart automatically as a system service.
- First Ethernet interface put on the martian network at 192.168.113.72.
- Second Ethernet interface configured to host a LAN at 192.168.114.xxx for communications with all vacuum electronics. It connects to a 16-port Ethernet switch installed in the vacuum electronics rack.
- Server installed in vacuum electronics rack (see photo).
✔ Set up of Acromag terminals.
- 6U rackmount chassis frame assembled; 15V DC, 24V DC, and Ethernet wired.
- Acromags installed in chassis and configured for the LAN (5 XT1111 units, 2 XT1121 units).
✔ EPICS database migration.
- All vacuum channels moved to the modbus IOC, with the database updated to address the new Acromags. [The new channels are running concurrently at "C1:Vac2-...." to avoid conflict with the existing system.]
- Each hard channel was individually tested on the electronics bench to confirm correct addressing and Acromag operation.
✔ Set up of 16-port IOLAN terminal server (for multiplexing/Ethernetizing the serial devices).
- Configured for operation on the LAN. Each serial device port is assigned a unique IP address, making the terminal server transparent to client TCP applications.
- Most of the pressure gauges are now communicating with the controls server via TCP.
Ongoing this week:
- [Jon] Continue migrating serial devices to ports on the terminal server. Still left are the turbo pumps, N2 gauge, and RGA.
- [Jon] Continue developing Python code for communicating with gauges and pumps via TCP sockets. A beta version of gauge readout code is running now.
- [Chub] Install feedthrough panels on the Acromag chassis. Connect the wiring from feedthrough panels to the assigned Acromag slots.
- [Chub/Jon] Test all the hard EPICS channels on the electronics bench, prior to installing the crate in the vacuum rack.
- [Chub/Jon] Install the crate in the vacuum rack; connect valve/pump readbacks and actuators; test each hard EPICS channel in situ.
- [Jon] Once all the signal connections have been made, in situ testing of the Python interlock code can begin.
|
14320
|
Mon Nov 26 21:58:08 2018 |
Jon | Omnistructure | | Serial Vacuum Signals | All the serial vacuum signals are now interfaced to the new digital controls system. A set of persistent Python scripts will query each device at regular intervals (up to ~10 Hz) and push the readings to soft channels hosted by the modbus IOC. Similar scripts will push on/off state commands to the serial turbo pumps.
IP Addresses/Comm Settings
Each serial device is assigned an IP address on the local subnet as follows. Its serial communication parameters as configured in the terminal server are also listed.
Device |
IP Address |
Baud Rate |
Data Bits |
Stop Bits |
Parity |
MKS937a vacuum gauge controller |
192.168.114.11 |
9600 |
8 |
1 |
even |
MKS937b vacuum gauge controller |
192.168.114.12 |
9600 |
8 |
1 |
even |
GP307 vacuum gauge controller |
192.168.114.13 |
9600 |
8 |
1 |
even |
GP316a vacuum gauge controller |
192.168.114.14 |
9600 |
8 |
1 |
even |
GP316b vacuum gauge controller |
192.168.114.15 |
9600 |
8 |
1 |
even |
N2 pressure line gauge |
192.168.114.16 |
9600 |
7 |
1 |
odd |
TP2/3 |
192.168.114.17/18 |
9600 |
8 |
1 |
none |
Hardware Modifications
- Each of the five vacuum gauge controllers has an RJ45 adapter installed directly on its DB9/DB25 output port. Because the RJ45 cable now plugs directly into the terminal server, instead of passing through some additional adapters as it formerly did, it was necessary to reverse the wiring of the controller TXD and RXD pins to Ethernet pins. The DB9/25-to-RJ45 adapters on the back of the controllers are now wired as follows.
- For the MKS controllers: DB2 (RXD) --> Eth4; DB3 (TXD) --> Eth5; DB5 (RTN) --> Eth6
- For the Granville-Phillips controllers: DB2 (TXD) --> Eth5; DB3 (RXD) --> Eth4; DB7 (RTN) --> Eth6
- I traced a communications error with the GP307 gauge controller all the way back to what I would have suspected least, the controller itself. The comm card inside each controller has a set of mechanical relay switches which set the communications parameters (baud rate, parity, etc.). Knowing that this controller was not part of the original installation, but was swapped in to replace the original in 2009, I pulled the controller from the rack and checked the internal switch settings. Sure enough, the switch settings (pictured below) were wrong. In the background of the photo is the unit removed in 2009, which has the correct settings. After setting the correct communications parameters, the controller immediately began communicating with the server. Did these readouts (PRP, PTP1) never work since 2009? I don't see how they could.
|
14325
|
Fri Nov 30 15:53:52 2018 |
Jon | Omnistructure | General | N2 pressure gauge fix | I've made a repair to the N2 pressure monitor. I don't believe the polarity of the analog signal into the controller actually was reversed. I found the data sheet (attached) for the transducer model we have installed. Its voltage should read ~0 at 0 PSI and 100mV at 100 PSI. As wired, the input voltage reads +80 mV as it should.
The controller calibrates the sensor voltage to PSI (i.e., applies a scale and offset) based on two settable reference points which appeared to be incorrect. I changed them to:
- 0 mV = 0 PSI (neglecting the small dark bias)
- 100 mV = 100 PSI
After the change, the pressure reads 80 PSI. Let's see if the time history now shows a sensible trend.
Quote: |
[koji, gautam, jon, steve]
- We suspect analog voltage from N2 pressure gauge is connected to interfacing Omega controller with the 'wrong' polarity (i.e pressure is rising over ~4 days and then rapidly falling instead of the other way around). This should be fixed.
|
|
14327
|
Sun Dec 2 16:08:44 2018 |
Jon | Omnistructure | Upgrade | Feedthroughs for Vacuum Acromag Chassis | Below is an inventory of the signal feedthroughs that need to be installed on the vacuum Acromag crate this week.
Type |
Qty |
Connects to |
# Chs |
Signals |
DB-37 female |
1 |
Main AC relay box |
18 |
Valve/roughing pump control |
DB-9 female |
5** |
Satellite AC relay boxes |
3-4/box |
Valve control |
DB-25 male |
1 |
Turbo pump 1 controller |
5 |
Pump status readbacks |
DB-9 male |
30 |
Valve position indicators |
2/valve |
Valve position readbacks |
DB-9 male |
3 |
Roughing pump controllers |
1/pump |
Pump status readbacks |
DB-9 male |
1 |
Cryo pump controller |
2 |
Pump status readbacks |
**The original documentation lists five satellite boxes (one for each test mass chamber and one for the beamsplitter chamber), but Chub reports not all of them are in use. We may remove the ones not used. |
14330
|
Tue Dec 4 10:38:12 2018 |
Jon | Omnistructure | Upgrade | Updated Feedthrough List for Vacuum Acromag Chassis | Based on new input from Chub, attached is the revised list of signal cable feedthroughs needed on the vacuum system Acromag crate. I believe this list is now complete. |
14331
|
Tue Dec 4 18:24:05 2018 |
gautam | Omnistructure | General | N2 line disconnected | [jon, gautam]
In the latest installment in this puzzler: turns out that maybe the trend of the "N2 pressure" channel increasing over the ~3 day timescale it takes a cylinder of N2 to run out is real, and is a feature of the way our two N2 cylinder lines/regulators are setup (for the automatic switching between cylinders when one runs out). In order to test this hypothesis, we'd like to have the line pressure be 0 initially, and then just have 1 cylinder hooked up. When we went into the drill-press area, we heard a hiss, turns out that one of the cylinders is leaking (to be fair, this was labelled, but i thought it isn't great to have a higher N2 concentration in an enclosed space). Since we don't need any actuation ability, I valved off the leaky cylinder, and disconnected the other properly functioning one. Attachment #1 shows the current state. |
14333
|
Thu Dec 6 17:33:33 2018 |
Jon | Omnistructure | General | N2 line disconnected | I believe I finally have the N2 gauge working correctly. The wiring is unchanged from its original state and the controller has been recalibrated.
After letting the line pressure drop to 0 PSI as indicated by the analog gauge in the drill-press room, I recorded the number of counts read by the Omega controller. Then I pressurized the line to 80 PSI, again indicated by the analog gauge, and recorded the Omega counts again. I entered these two reference points into the controller (automatically determines the gain and offset from these), then confirmed the readings to agree with the anaog gauge as I varied the line pressure.
The two reference points are:
0 PSI : 13 counts
80 PSI : 972 counts
Quote: |
[jon, gautam]
In the latest installment in this puzzler: turns out that maybe the trend of the "N2 pressure" channel increasing over the ~3 day timescale it takes a cylinder of N2 to run out is real, and is a feature of the way our two N2 cylinder lines/regulators are setup (for the automatic switching between cylinders when one runs out). In order to test this hypothesis, we'd like to have the line pressure be 0 initially, and then just have 1 cylinder hooked up.
|
|
14348
|
Wed Dec 12 18:27:07 2018 |
Jon | Omnistructure | Upgrade | Analog signals, A/D Acromag added to vacuum system | There turned out to be a few analog signals for the vacuum system after all. The TP2/3 foreline pressure gauges were never part of the digital system, but we wanted to add them, as some of the interlock conditions should be predicated on their readings. Each gauge connects to an old Granville-Phillips 375 controller which only has an analog output. Interfacing these signals with the new system required installing an Acromag XT1221 8-channel A/D unit. Taking advantage of the extra channels, I also moved the N2 delivery line pressure transducer to the XT1221, eliminating the need for its separate Omega DPiS32 controller. When the new high-pressure transducers are added to the two N2 tanks, their signals can also be connected.
The XT1221 is mounted on the DIN rail inside the chassis and I have wired a DB-9 feedthrough for each of its three input signals. It is assigned the IP 192.168.114.27 on the vacuum subnet. Testing the channels in situ revealed a subtley in calibrating them to physical units. It was first encountered by Johannes in a series of older posts, but I repeat it here in one place.
An analog-input EPICS channel can be calibrated from raw ADC counts to physical units (e.g., sensor voltage) in two ways:
- Via LINR="LINEAR" by setting the engineering-units fields EGUF="[V_max_adc]", EGUL="[V_min_adc]"
- Via LINR="NO CONVERSION" by manually setting the gain ASLO="[V/count]" and offset AOFF="[V_offset]"
From the documentation, under the engineering-units method EPICS internally computes:

where EGUF="eng units full scale", EGUL="eng units low", and "full scale A/D counts" is the full range of ADC counts. EPICS automatically infers the range of ADC counts based on the data type returned by the ADC. For a 16-bit ADC like the XT1221, this number is 2^16 = 65,536.
The problem is that, for unknown reasons, the XT1221 rescales its values post-digitization to lie within the range +/-30,000 counts. This corresponds to an actual "full scale A/D counts" = 60,001. If a multiplicative correction factor of 65,536/60,000 is absorbed into the values of EGUF and EGUL, then the first term in the above summation can be corrected. However, the second term (the offset) has no dependence on "full scale A/D counts" and should NOT absorb a correction factor. Thus adjusting the EGUF and EGUL values from, e.g., 10V to 10.92V is only correct when EGUL=0V. Otherwise there is a bias introduced from the offset term also being rescaled.
The generally correct way to handle this correction is to use the manual "NO CONVERSION" method. It constructs calibrated values by simply applying a specified gain and offset to the raw ADC counts:
calibrated val = (measured A/D counts) x ASLO + AOFF
The gain ASLO="[(V_max_adc - V_min_adc) / 60,001]" and the offset AOFF="0". I have tested this on the three vacuum channels and confirmed it works. Note that if the XT1221 input voltage range is restricted from its widest +/-10V setting, the number of counts is not necessarily 60,001. Page 42 of the manual gives the correct counts for each voltage setting. |
14375
|
Thu Dec 20 21:29:41 2018 |
Jon | Omnistructure | Upgrade | Vacuum Controls Switchover Completed | [Jon, Chub, Koji, Gautam]
Summary
Today we carried out the first pumpdown with the new vacuum controls system in place. It performed well. The only problem encountered was with software interlocks spuriously closing valves as the Pirani gauges crossed 1E-4 torr. At that point their readback changes from a number to "L OE-04, " which the system interpreted as a gauge failure instead of "<1E-4." This posed no danger and was fixed on the spot. The main volume was pumped to ~10 torr using roughing pumps 1 and 3. We were limited only by time, as we didn't get started pumping the main volume until after 1pm. The three turbo pumps were also run and tested in parallel, but were isolated to the pumpspool volume. At the end of the day, we closed every pneumatic valve and shut down all five pumps. The main volume is sealed off at ~10 torr, and the pumpspool volume is at ~1e-6 torr. We are leaving the system parked in this state for the holidays.
Main Volume Pumpdown Procedure
In pumping down the main volume, we carried out the following procedure.
- Initially: All valves closed (including manual valves RV1 and VV1); all pumps OFF.
- Manually connected roughing pump line to pumpspool via KF joint.
- Turned ON RP1 and RP2.
- Waited until roughing pump line pressure (PRP) < 0.5 torr.
- Opened V3.
- Waited until roughing pump line pressure (PRP) < 0.5 torr.
- Manually opened RV1 throttling valve to main volume until pumpdown rate reached ~3 torr/min (~3 hours on roughing pumps).
- Waited until main volume pressure (P1a/P1b) < 0.5 torr.
We didn't quite reach the end of step 8 by the time we had to stop. The next step would be to valve out the roughing pumps and to valve in the turbo pumps.
Hardware & Channel Assignments
All of the new hardware is now permanently installed in the vacuum rack. This includes the SuperMicro rack server (c1vac), the IOLAN serial device server, a vacuum subnet switch, and the Acromag chassis. Every valve/pump signal cable that formerly connected to the VME bus through terminal blocks has been refitted with a D-sub connector and screwed directly onto feedthroughs on the Acromag chassis.
The attached pdf contains the master list of assigned Acromag channels and their wiring. |
14377
|
Fri Dec 21 11:13:13 2018 |
gautam | Omnistructure | VAC | N2 line valved off | Per the discussion yesterday, I valved off the N2 line in the drill press room at 11 am PST today morning so as to avoid any accidental software induced gate-valve actuation during the holidays. The line pressure is steadily dropping...
Attachment #1 shows that while the main volume pressure was stable overnight, the the pumpspool pressure has been steadily rising. I think this is to be expected as the turbo pumps aren't running and the valves can't preserve the <1mtorr pressure over long timescales?
Attachment #2 shows the current VacOverview MEDM screen status. |
14379
|
Fri Dec 21 12:57:10 2018 |
Koji | Omnistructure | VAC | N2 line valved off | Independent question: Are all the turbo forelines vented automatically? We manually did it for the main roughing line.
|
14380
|
Thu Jan 3 15:08:37 2019 |
gautam | Omnistructure | VAC | Vac status unknown | Larry W came by the 40m, and reported that there was a campus-wide power glitch (he was here to check if our networking infrastructure was affected). I thought I'd check the status of the vacuum.
- Attachment #1 is a screenshot of the Vac overview MEDM screen. Clearly something has gone wrong with the modbus process(es). Only the PTP2 and PTP3 gauges seem to be communicative.
- Attachment #2 shows the minute trend of the pressure gauges for a 12 day period - it looks like there is some issue with the frame builder clock, perhaps this issue resurfaced? But checking the system time on FB doesn't suggest anything is wrong.. I double checked with dataviewer as well that the trends don't exist... But checking the status of the individual daqd processes indeed showed that the dates were off by 1 year, so I just restarted all of them and now the time seems correct. How can we fix this problem more permanently? Also, the P1b readout looks suspicious - why are there periods where it seems like we are reading values better than the LSB of the device?
I decided to check the systemctl process status on c1vac:
controls@c1vac:~$ sudo systemctl status modbusIOC.service
● modbusIOC.service - ModbusIOC Service via procServ
Loaded: loaded (/etc/systemd/system/modbusIOC.service; enabled)
Active: active (running) since Thu 2019-01-03 14:53:49 PST; 11min ago
Main PID: 16533 (procServ)
CGroup: /system.slice/modbusIOC.service
├─16533 /usr/bin/procServ -f -L /opt/target/modbusIOC.log -p /run/...
├─16534 /opt/epics/modules/modbus/bin/linux-x86_64/modbusApp /opt/...
└─16582 caRepeater
Jan 03 14:53:49 c1vac systemd[1]: Started ModbusIOC Service via procServ.
Warning: Unit file changed on disk, 'systemctl daemon-reload' recommended.
So something did happen today that required restart of the modbus processes. But clearly not everything has come back up gracefully. A few lines of dmesg (there are many more segfaults):
[1706033.718061] python[23971]: segfault at 8 ip 000000000049b37d sp 00007fbae2b5fa10 error 4 in python2.7[400000+31d000]
[1706252.225984] python[24183]: segfault at 8 ip 000000000049b37d sp 00007fd3fa365a10 error 4 in python2.7[400000+31d000]
[1720961.451787] systemd-udevd[4076]: starting version 215
[1782064.269844] audit: type=1702 audit(1546540443.159:38): op=linkat ppid=21820 pid=22823 auid=4294967295 uid=1000 gid=1000 euid=1000 suid=1000 fsuid=1000 egid=1000 sgid=1000 fsgid=1000 tty=pts0 ses=4294967295 comm="git" exe="/usr/bin/git" res=0
[1782064.269866] audit: type=1302 audit(1546540443.159:39): item=0 name="/cvs/cds/caltech/target/c1vac/.git/objects/85/tmp_obj_uAXhPg" inode=173019272 dev=00:21 mode=0100444 ouid=1001 ogid=1001 rdev=00:00 nametype=NORMAL
[1782064.365240] audit: type=1702 audit(1546540443.255:40): op=linkat ppid=21820 pid=22823 auid=4294967295 uid=1000 gid=1000 euid=1000 suid=1000 fsuid=1000 egid=1000 sgid=1000 fsgid=1000 tty=pts0 ses=4294967295 comm="git" exe="/usr/bin/git" res=0
[1782064.365271] audit: type=1302 audit(1546540443.255:41): item=0 name="/cvs/cds/caltech/target/c1vac/.git/objects/58/tmp_obj_KekHsn" inode=173019274 dev=00:21 mode=0100444 ouid=1001 ogid=1001 rdev=00:00 nametype=NORMAL
[1782064.460620] audit: type=1702 audit(1546540443.347:42): op=linkat ppid=21820 pid=22823 auid=4294967295 uid=1000 gid=1000 euid=1000 suid=1000 fsuid=1000 egid=1000 sgid=1000 fsgid=1000 tty=pts0 ses=4294967295 comm="git" exe="/usr/bin/git" res=0
[1782064.460652] audit: type=1302 audit(1546540443.347:43): item=0 name="/cvs/cds/caltech/target/c1vac/.git/objects/cb/tmp_obj_q62Pdr" inode=173019276 dev=00:21 mode=0100444 ouid=1001 ogid=1001 rdev=00:00 nametype=NORMAL
[1782064.545449] audit: type=1702 audit(1546540443.435:44): op=linkat ppid=21820 pid=22823 auid=4294967295 uid=1000 gid=1000 euid=1000 suid=1000 fsuid=1000 egid=1000 sgid=1000 fsgid=1000 tty=pts0 ses=4294967295 comm="git" exe="/usr/bin/git" res=0
[1782064.545480] audit: type=1302 audit(1546540443.435:45): item=0 name="/cvs/cds/caltech/target/c1vac/.git/objects/e3/tmp_obj_gPI4qy" inode=173019277 dev=00:21 mode=0100444 ouid=1001 ogid=1001 rdev=00:00 nametype=NORMAL
[1782064.640756] audit: type=1702 audit(1546540443.527:46): op=linkat ppid=21820 pid=22823 auid=4294967295 uid=1000 gid=1000 euid=1000 suid=1000 fsuid=1000 egid=1000 sgid=1000 fsgid=1000 tty=pts0 ses=4294967295 comm="git" exe="/usr/bin/git" res=0
[1783440.878997] systemd[1]: Unit serial_TP3.service entered failed state.
[1784682.147280] systemd[1]: Unit serial_TP2.service entered failed state.
[1786407.752386] systemd[1]: Unit serial_MKS937b.service entered failed state.
[1792371.508317] systemd[1]: serial_GP316a.service failed to run 'start' task: No such file or directory
[1795550.281623] systemd[1]: Unit serial_GP316b.service entered failed state.
[1796216.213269] systemd[1]: Unit serial_TP3.service entered failed state.
[1796518.976841] systemd[1]: Unit serial_GP307.service entered failed state.
[1796670.328649] systemd[1]: serial_Hornet.service failed to run 'start' task: No such file or directory
[1797723.446084] systemd[1]: Unit serial_MKS937b.service entered failed state.
I don't know enough about the new system so I'm leaving this for Jon to debug. Attachment #3 shows that the analog readout of the P1 pressure gauge suggests that the IFO is still under vacuum, so no random valve openings were effected (as expected, since we valved off the N2 line for this very purpose). |
14383
|
Fri Jan 4 10:25:19 2019 |
Jon | Omnistructure | VAC | N2 line valved off | Yes, for TP2 and TP3. They both have a small vent valve that opens automatically on shutdown.
Quote: |
Independent question: Are all the turbo forelines vented automatically? We manually did it for the main roughing line.
|
|
14384
|
Fri Jan 4 11:06:16 2019 |
Jon | Omnistructure | Upgrade | Vac System Punchlist | The base Acromag vacuum system is running and performing nicely. Here is a list of remaining questions and to-do items we still need to address.
Safety Issues
- Interlock for HV supplies. The vac system hosts a binary EPICS channel that is the interlock signal for the in-vacuum HV supplies. The channel value is OFF when the main volume pressure is in the arcing range, 3 mtorr - 500 torr, and ON otherwise. Is there something outside the vacuum system monitoring this channel and toggling the HV supplies?
- Exposed 30-amp supply terminals. The 30-amp output terminals on the back of the Sorensen in the vac rack are exposed. We need a cover for those.
- Interlock for AC power loss. The current vac system is protected only from transient power glitches, not an extended loss. The digital system should sense an outage and put the IFO into a safe state (pumps spun down and critical valves closed) before the UPS battery is fully drained. However, it presently has no way of sensing when power has been lost---the system just continues running normally on UPS power until the battery dies, at which point there is a sudden, uncontrolled shutdown. Is it possible for the digital system to communicate directly with the UPS to poll its activation state?
Infrastructure Improvements
- Install the new N2 tank regulator and high-pressure transducers (we have the parts; on desk across from electronics bench). Run the transducer signal wires to the Acromag chassis in the vacuum rack.
- Replace the kludged connectors to the Hornet and SuperBee serial outputs with permanent ones (we need to order the parts).
- Wire the position indicator readback on the manual TP1 valve to the Acromag chassis.
- Add cable tension relief to the back of the vac rack.
- Add the TP1 analog readback signals (rotation speed and current) to the digital system. Digital temperature, current, voltage, and rotation speed signals have already been added for TP2 and TP3.
- Set up a local vacuum controls terminal on the desk by the vac rack.
- Remove gauges from the EPICS database/MEDM screens that are no longer installed or functional. Potential candidates for removal: PAN, PTP1, IG1, CC2, CC3, CC4.
- Although it appeared on the MEDM screen, the RGA was never interfaced to the old vac system. Should it be connected to c1vac now?
|
14410
|
Sun Jan 20 23:41:00 2019 |
Jon | Omnistructure | VAC | Notes on vac serial comm, adapter wiring | I've attached my handwritten notes covering all the serial communications in the vac system, and the relevant wiring for all the adapters, etc. I'll work with Chub to produce a final documentation, but in the meantime this may be a useful reference. |
14493
|
Thu Mar 21 18:36:59 2019 |
Jon | Omnistructure | Upgrade | Vacuum Controls Switchover Completed | Updated vac channel list is attached. There are several new ADC channels.
Quote: |
Hardware & Channel Assignments
All of the new hardware is now permanently installed in the vacuum rack. This includes the SuperMicro rack server (c1vac), the IOLAN serial device server, a vacuum subnet switch, and the Acromag chassis. Every valve/pump signal cable that formerly connected to the VME bus through terminal blocks has been refitted with a D-sub connector and screwed directly onto feedthroughs on the Acromag chassis.
The attached pdf contains the master list of assigned Acromag channels and their wiring.
|
|
14589
|
Thu May 2 15:15:15 2019 |
Jon | Omnistructure | Computers | susaux machine renamed | Now that the replacement susaux machine is installed and fully tested, I renamed it from c1susaux2 to c1susaux and updated the DNS lookup tables on chiara accordingly. |
14590
|
Thu May 2 15:35:54 2019 |
Jon | Omnistructure | Upgrade | c1susaux upgrade documentation | For future reference:
- The updated list of c1susaux channel wiring (includes the "coil enable" --> "coil test" digital outputs change)
- Step-by-step instructions on how to set up an Acromag system from scratch
|
14600
|
Thu May 9 22:26:39 2019 |
Jon | Omnistructure | PSL | Second ADC added to PSL Acromag crate | This evening I added a second ADC module to the prototype Acromag chassis. This chassis can now read out all the PSL diagnostic channels.
I configured the second ADC identically to the first ("ADC0"), and assigned it IP address 192.168.113.122 . I confirmed it is visible on the martian network.
There was an existing but unused DB-15 feedthrough which I used for ADC1 channels 1-7. The eighth channel I left unwired, but there are slots available in the neighboring DB-25 feedthough, if that channel is needed in the future. The channel wiring assignments are as follows.
ADC1 Channel |
DB-15 Feedthrough Pin |
0+ |
1 |
0- |
9 |
1+ |
2 |
1- |
10 |
2+ |
3 |
2- |
11 |
3+ |
4 |
3- |
12 |
4+ |
5 |
4- |
13 |
5+ |
6 |
5- |
14 |
6+ |
7 |
6- |
15 |
7+ |
not connected |
7- |
not connected |
I tested all seven of these channels by applying a calibrated voltage source and measuring the response via the Windows Acromag software. All work and are correctly calibrated to better than 0.1%. |
14814
|
Fri Jul 26 19:53:53 2019 |
Jon | Omnistructure | Cameras | GigE Camera Server | I've started setting up the last new rackmount SuperMicro as a dedicated server for the GigE cameras. The new machine is currently sitting on the end of the electronics test bench. It is assigned the hostname c1cam at IP 192.168.113.116 on the martian network. I've installed Debian 10, which will be officially supported until July 2024.
I've added the /cvs/cds NFS mount and plan to house all the client/server code on this network disk. Any dependencies that must be built from source will be put on the network disk as well. Any dependencies that can be gotten through the package manager, however, will be installed locally but in an automated way using a reqs file.
We should ask Chub to reorder several more SuperMicro rackmount machines, SSD drives, and DRAM cards. Gautam has the list of parts from Johannes' last order. |
15067
|
Tue Dec 3 20:32:37 2019 |
rana | Omnistructure | DAQ | NDS2 situation | Recently, accordian to Gautam, the NDS2 server has been dying on Megatron ~daily or weekly. The prescription is to restart the server.
- I could find no instructions (that work) in the elog or wiki. We must remove the misleading entries from the wiki and update it with whatever works as of today.
- There is a line (which has been commented out) in the Megatron crontab which is close to the right command, but it has the wrong path.
- Running the command from the CRON (/home/nds2mgr/nds2-megatron/test_restart), gives several errrors.
- when I run the init.d command which is in the script, it seems to run fine
- the server then takes several minutes to get itself together; i.e. just because it is running doesn't mean that you can get data. I recommend waiting 5-10 minutes.
Also, megatron is running Ubuntu 12 !! Let's decide on a day to upgrade it to a Debian 18ish....word from Rolf is that Scientific Linux is fading out everywhere, so Debian is the new operating system for all conformists. |
15284
|
Thu Mar 26 17:41:18 2020 |
Jon | Omnistructure | BHD | BHD docs compilation | Since there has been a proliferation of BHD Google docs recently, I've linked them all from the BHD wiki page. Let's continue adding any new docs to this central list. |
15412
|
Thu Jun 18 22:33:57 2020 |
Jon | Omnistructure | VAC | Vac hardware purchase list | Replacement Hardware Purchase List
I've created a purchase list of hardware needed to restore the aging vacuum system. This wasn't planned as part of the BHD upgrade, but I've added it to the BHD procurement list since hardware replacements have become necessary.
The list proposes replacing the aging TP3 Varian turbo pump with the newer Agilent model which has already replaced TP2. It seems I was mistaken in believing we already had a second Agilent pump on hand. A thorough search of the lab has not turned it up, and Steve himself has told me he doesn't remember ordering a second one. Fortunately Steve did leave us a detailed Agilent parts list [ELOG 14322].
It also proposes replacing the glitching TP2 Agilent controller with a new one. The existing one can be sent back for repair and then retained as a spare. Considering that one of these controllers is already malfunctioning after < 2 years, I think it's a very good idea to have a spare on hand.
Known Hardware Issues
Below is our current list of vacuum hardware issues. Items that this purchase list will address (limited to only the most urgent) are highlighted in yellow.
- Replace the UPS
- Need a 240V socket for TP1 (currently TP1 is not protected from power loss)
- Need RS232/485 comms with the interlock server (current UPS: serial readbacks have failed, battery is failing)
- Remove/replace the failed pressure gauges (~5)
- Add more cold cathode sensors to the main volume for sensor redundancy (currently the main-volume interlocks rely on only 1 working sensor)
- Replace TP3 (controller is failing)
- Replace TP2 controller (serial interface has failed)
- Remove RP2
- Dead and also not needed. We already have to throttle the pumpdown rate with only two roughing pumps
- Remove/refurbish the cryopump
- Contamination risk to have it sitting connectable to the main volume
|
17193
|
Mon Oct 17 11:57:27 2022 |
Chris | Omnistructure | CDS | Timing system monitoring | I started a GPS timing monitor script, /opt/rtcds/caltech/c1/Git/40m/scripts/cds/tempusTimingMon/tempusTimingMon.py , which runs inside a docker container on optimus. It accesses the GPS receiver (EndRun Tempus LX) status via pysnmp, and creates the following epics channels with pcaspy:
C1:DAQ-GPS_TFOM “The Time Figure of Merit (TFOM) value ranges from 3 to 9 and indicates the current estimate of the worst case time error. It is a logarithmic scale, with each increment indicating a tenfold increase in the worst case time error boundaries.” (nominally 3, corresponding to 100 nsec)
C1:DAQ-GPS_STATE “Current GPS signal processor state. One of 0, 1 or 2, with 0 being the acquisition state and 2 the fully locked on state.”
C1:DAQ-GPS_SATS “Current number of GPS satellites being tracked.”
C1:DAQ-GPS_DAC “Current 16 bit, Voltage Controlled TCXO DAC value. Typical range is 20000 to 40000, where more positive numbers have the effect of raising the TCXO frequency.”
C1:DAQ-GPS_SNR “The current average carrier to noise ratio of all tracked satellites, in units of dB. Values less than 35 indicate weak signal conditions.”
Attached is a 1-day trend of the above channels, along with the IRIG-B timing offsets from the IOPs. No big timing excursions or slippages were seen yet, although the c1sus IOP (FEC-20) timing seems to be hopping around by one IOP sample time (15 µsec). |
5
|
Fri Oct 19 16:11:38 2007 |
pkp | Other | OMC | OMC PZT response | Sam and I locked the laser to the OMC cavity and looked at the error signal as a function of the voltage applied to the OMC PZT.
Here are two plots showing the response as a function of frequency from 1 kHz to 100 kHz and another high-res response in the region of 4.5 kHz to 10 kHz. |
6
|
Sat Oct 20 11:54:13 2007 |
waldman | Other | OMC | OMC and OMC-SUS work | [Rich, Chub, Pinkesh, Chris, Sam]
Friday the 18th was a busy day in OMC land. Both DCPDs were mounted to the glass breadboard and the OMC-SUS structure was rebuilt to the point that an aluminum dummy mass is hanging, unbalanced. The OSEMs have not be put on the table cloth yet, but everything is hanging free. As for the DCPDs, if you recall one beam is 3mm off center from the DCPD tombstone. Fortunately, one DCPD is nearly 3mm offcenter from the case in the right direction, so the errors nearly cancel. The DCPD is too high, so the beam isn't quite centered, but they're close. We'll get photos of the beam positions in someday. Also, the DC gain between the two PDs is, at first glance, different by 15%. DCPD1, the one seen in transmission has 315 mV of signal while DCPD2 has 280 mV. Not sure why, could be because of beam alignment or tolerances in the Preamp or the angle incident on the diode or the QE of the diodes. The glass cans have *not* been removed.
|
8
|
Mon Oct 22 19:27:14 2007 |
pkp | Other | OMC | PZT calibration/ transfer function. | We measured the PZT transfer function by comparing the PZT response of the circuit with the cavity in the loop, with that of the circuit without the cavity in the loop. Basically measure the transfer function of the whole loop with the laser/PZT and Op-amps in it. Then take another measurement of the transfer function of everything else besides the PZT and from both these functions, we can calculate the PZT response.
The calibration was done by using the error signal response to a triangular wave of volts applied to the PZT. A measurement of the slope of the error signal , which has three zero-crossings as the cavity sweeps through the sidebands, gives us the Volts/Hz response. In order to derive a frequency calibration of the x axis, we assume that the first zero crossing corresponds to the first side band (-29.5 MHz) and the third one corresponds with the other sideband (+29.5 MHz). And then by using the fact that we know the response of the cavity to a constant frequency shift, we can use the Volts/Hz measurement to calculate the Volts/nm calibration. The slope that was calculated was 3.2e-6 V/Hz and using the fact that the cavity is 1 m in length and the frequency is 1064 nm, we get a calibration of 0.9022 V/nm.
|
9
|
Tue Oct 23 09:01:00 2007 |
rana | Other | OMC | PZT calibration/ transfer function. | Are you sure that the error signal sweep is not saturated on the top ends? This is usually the downfall
of this calibration method. |
10
|
Tue Oct 23 11:08:20 2007 |
steve | Other | General | brush fires | There are big brush fires around LA
40 days plot show no effect in the 40m lab |
11
|
Wed Oct 24 01:43:32 2007 |
Andrey Rodionov | Other | General | PDF-file -> Will report about first results for XARM during Wednesday meeting |
Here is the pdf-file with some graphs showing first results for XARM optimization.
We will discuss alltogether during our Wednesday meeting which starts at 2.40PM. Probably it would be necessary to project this pdf-file to the big screen,
so someone should bring laptop and probably connect it to the projector. I do not have a laptop.
See you on that meeting. |
12
|
Wed Oct 24 08:58:09 2007 |
steve | Other | PSL | laser headtemp is up | C1:PSL-126MOPA_HTEMP is 19.3C
Half of the chiller's air intake was covered by loose paper |
14
|
Thu Oct 25 17:52:45 2007 |
waldman | Other | OMC | OMCs with QPDs | [Rich, Chub, Pinkesh, Sam]
Yesterday we got the QPD, OTAS, and PZT cabling harness integrated with the OMC. We found a few things out, not all of them good. The QPDs went on no problem and could be fairly well aligned by hand. We "aligned" them by looking at all four channels of the QPD on the scope and seeing that there is signal. Since the beam is omega = 0.5 mm, this is a reasonable adjustment. We then connected the OTAS connector to the OTAS and found that the heater on the OTAS was bonded on about 30 degrees rotated from its intended position. This rotated the connector into the beam and caused a visible amount of scattering. This wasn't really a disaster until I removed the connector from the heater and broke the heater off of the aluminum parts of the OTAS. Two steps backwards, one step forward. After the OMC, OMC-SUS integration test we will re-bond the heater to the aluminum using VacSeal. In the meantime, the OMC has been moved to Bridge 056 for integration with the OMC-SUS. More on that as we make progress. |
16
|
Thu Oct 25 23:35:36 2007 |
waldman | Other | OMC | Hang the OMC! | [Pinkesh, Sam]
We tried, convicted and hung the OMC today. The OMC was found guilty of being overweight, and unsymmetrically balanced. The unsymmetry was kind of expected and was corrected with a hefty stack of counterweights positioned over the counterweighting holes. The stacks will be measured at some future date and correctly sized objects machined. The overweightness showed up when the level hanging breadboard was about 5 mm low. This showed up in the board height above the table as well as the OSEM flag positions within their holes. The problem was remedied with a liposuction of the intermediate mass. We removed both small vertical cylinder weights that Chris added, and then we removed the heavy steel transverse weight that can be used to adjust the tip around the long axis (I forgot what its called).
The top of the breadboard ended up about 154 mm off the table. The breadboard is 39 mm thick, and the optics are centered (30 - 12.7) = 17.3 mm below the surface for a as hanging beams height of 154 -39 - 17.3 = 97.7 mm or about an 0.150 inches lower than we were aiming for. Can I get a refund?
We screwed up in multiple ways:
- The slotted disks that capture the wires do not have the alignment bore used to center the wire in the hole
- We didn't correctly route the far field QPD cable so it runs funny
- We didn't have a tool which could be used to get two of the DCPD preamp box mounting screws (which are M3's chub!)
- We don't have the cable clamps to tie off the electrical cables to the intermediate mass
- We don't have any of the cabling from the OMC-SUS top to the rack so we can't test anything
- We haven't uploaded pretty pictures for all to see
We left the OMC partially suspended by the OMC-SUS and partly resting on the installation lab jacks which are currently acting as EQ stops. After we fix the cabling we will more permanently hang it. PS, It looks like the REFL beam extraction will be tricky so we need to get on that.... |
19
|
Fri Oct 26 17:34:43 2007 |
waldman | Other | OMC | OMC + earthquake stops |
[Chub, chris, Pinkesh, Sam]
Last night we hugn the OMC for the first time and came up with a bunch of pictures and some problems. Today we address some of the problems and, of course, make new problems. We replaced the flat slotted disks with the fitted slotted disks that are made to fit into the counterbore of the breadboard. This changed the balance slightly and required a more symmetric distribution of mass. It probably did not change the total mass very much. We did find that the amount of cable hanging down strongly affected the breadboard balance and may also have contributed to the changing balance.
We also attached earthquake stops and ran into a few problems:
- The bottom plate of the EQ stops is too thick so that it bumps into the tombstones
- The vertical member on the "waist" EQ stops is too close to the breadboard, possibly interfering with the REFL beam
- The "waist" EQ stops are made from a thin plate that doesn't have enough thickness to mount helicoils in
- Helicoil weren't loaded in the correct bottom EQ stops
- The DCPD cable loops over the end EQ stop looking nasty but not actually making contact
However, with a little bit of jimmying, the EQ stops are arrayed at all points within a few mm of the breadboard. Meanwhile, Chub has cabled up all the satellite modules and DCPD modules and Pinkesh is working on getting data into the digital system so we can start playing games. Tonight, I intend to mount a laser in Rana's lab and fiber couple a beam into the 056 room so we can start testing the suspended OMC. |
29
|
Tue Oct 30 00:47:29 2007 |
rana | Other | IOO | MC Ringdowns | I did a bunch of MC ringdown measurements using the PD that Rob set up. The idea is to put a fast PD (PDA255)
looking at the transmission through MC2 after focusing by a fast lens. The input to the MC is turned off fast
by flipping the sign of the FSS (Andri Gretarsson's technique).
With the laptop sitting on the MC can, its easy to repeat many ringdowns fast:
- Turn off the MC autolocker. Relock the MC with only the acquisition settings; no boosts
and no RGs. This makes it re-acquire fast. Turn the MC-WFS gain down to 0.001 so that
it keeps it slowly aligned but does not drift off when you lose lock.
- Use low-ish gain on the FSS. 10 dB lower than nominal is fine.
- Setup the o'scope (100 MHz BW or greater) to do single shot trigger on the MC2 trans.
- Flip FSS sign.
- Quickly flip sign back and waggle common gain to get FSS to stop oscillating. MC
should relock in seconds.
Clearly one can scriptify this all just by hooking up the scope to the ethernet port.
Attached are a bunch of PNG of the ringdowns as well as a tarball with the actual data. A sugar
napoleon to whomever can explain the 7 us period of the wiggle before the vent! |
33
|
Tue Oct 30 20:15:24 2007 |
tobin | Other | Environment | earthquake | Rana, Tobin
Largish (M5.6) earthquake in San Francisco sent our optics swinging. |
35
|
Wed Oct 31 08:34:35 2007 |
rana | Other | IOO | loss measurements | In the end, we were unable to get a good scatter measurement just because we ran out of steam. The idea was to get a frame
grab image of MC2 but that involves getting an unsaturated image.
In the end we settle for the ringdowns, Rob's (so far unlogged) cavity pole measurement, and the MC transmission numbers. They
all point to ~100-150 ppm scatter loss per mirror. We'll see what happens after wiping. |
37
|
Wed Oct 31 09:45:28 2007 |
waldman | Other | OMC | Resolution to DAQland saga | [Jay, Sam]
We did a rough accounting for the linear delay this morning and it comes out more or less correct. The 10 kHz 3rd order butterworth AA/AI filter gives ~90 degrees of phase at 6 kHz, or 42 microseconds. Taken together, the two AA and AI filters are worth 80 microseconds. The 1.5 sample digital delay is worth 1.5/32768 = 45 microseconds. The remaining 160 - 125 = 35 microseconds is most likely taken up by the 64 kHz to 32 kHz decimation routine, assuming this isn't accounted for already in the 1.5 sample digital delay.
It remains to be seen whether this phase delay is good enough to lock the laser to the OMC cavity |
42
|
Wed Oct 31 23:55:17 2007 |
waldman | Other | OMC | QPD tests | The 4 QPDs for the OMC have been installed in the 056 at the test setup. All 4 QPDs work and have medm screens located under C2TPT. The breadboard mounted QPDs are not very well centered so their signal is somewhat crappy. But all 4 QPDs definitely see plenty of light. I include light and dark spectra below. QPDs 1-2 are table-mounted and QPD 2 is labeled with a bit of blue tape. QDPs 3-4 are mounted on the OMC. QPD3 is the near field detector and QPD4 is the far field. In other words, QPD3 is closest to the input coupler and QPD4 is farthest.
Included below are some spectra of the QPDs with and without light. For QPDs 1 & 2, the light source is just room lights, while 3&4 have the laser in the nominal OMC configuration with a few mWs as source. The noise at 100 Hz is about 100 microvolts / rtHz. If I recall correctly, the QPDs have 5 kOhm transimpedance (right Rich?) so this is 20 nanoamps / rtHz of current noise at the QPD. |
43
|
Thu Nov 1 01:28:04 2007 |
waldman | Other | OMC | First digital lock of OMC | [Pinkesh, Sam]
We locked a fiber based NPRO to the suspended OMC tonight using the TPT digital control system. To control the laser frequency, we took the PZT AI output and ran it on a BNC cable down the hallway to the Thorlabs HV box. The Thorlabs is a singled ended unit so we connected the AI positive terminal only and grounded the BNC to the AI shield. We could get a -6 to 1.5 V throw in this method which fed into the 10 k resisotr + 9 V battery at the input of the HV box. The HV out ran to the NPRO PZT fast input.
We derived our error signal from a PDA255 in reflection with a 29.5 MHz PDH lock. The signal feeds into one of the unused Tip/Tilt AA channels and is passed to the PZT LSC drive through the TPT_PDH1 filter bank. In the PZT_LSC filter we put a single pole at 1 Hz which, together with the phase we mentioned the other night (180 degrees at 3 kHz) should allow a 1 kHz-ish loop. In practice, as shown below, we got a 650 Hz UGF with 45 degrees of phase margin and about 6 dB of gain margin.
The Lower figure shows the error point spectrum with 3 settings. REF0 in blue shows lots of gain peaking at 1.5 kHz-ish, just where its expected - the gain was -40. The REF1 has gain of -20 and shows no gain peaking. The current trace in red shows some gain peaking cuz the alignment is better but it also has included a 1^2:20^2 boost which totally crushes the low frequency noise. We should do a better loop sweep after getting the alignment right so we can see how much boost it will really take.
Just for fun, we are leaving it locked overnight and recording the PZT_LSC data for posterity. |
32
|
Tue Oct 30 19:32:13 2007 |
tobin | Problem Fixed | Computers | conlogger restarted | I noticed that the conlogger wasn't running. It looks like it hasn't been running since October 11th. I modified the restart_conlogger script to insist that it run on op340m instead of op440m, and then ran it on op340m. |
|