  3289   Mon Jul 26 10:02:42 2010 josephbUpdateCDSRerouted RFM around c1lsc, took RFM card out of c1lscIf you're refering to just the medm screen, 
those can be restored from the SVN. 
As we're moving to a new directory structure,
  
  3292   Mon Jul 26 12:31:36 2010 kiwamuUpdateCDSfront end machine for the X endA brief
report about the new front end machine "C1ISCEX"
installed on the X end (old Y end).
  
  3293   Mon Jul 26 14:24:46 2010 josephb, kiwamuUpdateCDSRFM test take 1Kiwamu and I strung a temporary RFM fiber
from the c1iscex machine (in the new 1X9
rack) to the c1sus machine (in the new 1X4
  
  3316   Thu Jul 29 11:33:38 2010 kiwamuUpdateCDSPCI5565 driver for RFM Yesterday I installed a PCI-5565
driver on new C1SUS in order to test the
  
  3317   Thu Jul 29 12:13:28 2010 kiwamuSummaryCDSnear term plan [Joe and Kiwamu]
 current_setup_v2.png 
  3319   Thu Jul 29 12:31:24 2010 josephbUpdateCDSWorking DAC, working IOP - next up SUSOk, after a few minutes of talking to Alex,
I got the correct "GUI syntax"
through my head, and we now have a simple
 Simple_Green_Control.png 
  3321   Thu Jul 29 15:35:21 2010 josephb, kiwamuUpdateCDSWorking out ADC/DAC/BO wiringWe are currently using the SUS wiring diagram
found on Ben Abbott's page (link here)
to determine the ADC/DAC/BO channel numbers
  
  3323   Thu Jul 29 17:12:48 2010 josephb, kiwamuUpdateCDSRe:Working out ADC/DAC/BO wiringWe
have installed  4 BO boards, 3 DAC boards
and 1 ADC board for new C1SUS.
They
 DSC_2302.png 
  3342   Sat Jul 31 17:37:36 2010 josephbUpdateCDSCables needed for CDS testLast Thursday, Kiwamu and I went through
the cabling necessary for a full damping
test of the vertex optics controled by the
  
  3353   Tue Aug 3 11:17:10 2010 kiwamuUpdateCDSDiagrams for Cables needed for CDS testCurrent Wiring Setup for the Suspension
Controls
 sus_wiring.pngsus_new_wiring.pngsus_missing_stuff.png 
  3399   Wed Aug 11 13:28:44 2010 josephbUpdateCDSNew cdsIPCx parts, old part breaks modelsWhile working on a test stand at LLO, I've
discovered that there's a new update to the
Real Time Code Generator that breaks virtually
  
  3405   Thu Aug 12 11:19:04 2010 kiwamuUpdateCDScurrent statusCurrent status of the new CDS test (summaries   
  3407   Thu Aug 12 11:59:31 2010 kiwamuHowToCDSset up ntp daemom(sad story)
When I was working on a new front
end machine c1sus, I found that
  
  3408   Thu Aug 12 14:01:53 2010 josephbUpdateCDScurrent statusFirst, awesome progress.
Second, the Binary Output parts do
  
  3414   Thu Aug 12 18:30:08 2010 kiwamuUpdateCDSRe: current statusYes.  
The medm screen C1SUS_GDS_TP.adl
showed some numbers which correspond
  
  3428   Tue Aug 17 02:07:11 2010 YoichiUpdateCDSDACs have correct number of channels


   
        
            
  
  3432   Wed Aug 18 11:40:59 2010 josephb,kiwamu,yoichiUpdateCDSEnd station working with latest RCG codeWe were able to get the latest SVN checkout
(revision 2009), working with the c1x00 (IOP)
and c1vgl models at the new X end on the
  
  3434   Wed Aug 18 12:24:58 2010 josephb,kiwamuUpdateCDSshmem issueApparently its possible to have working
models get into a bad state in regards to
shared memory, which prevents the model from
  
  3458   Mon Aug 23 19:55:31 2010 kiwamuUpdateCDSsome progress {Joe, Kiwamu}
Today
  
  3473   Thu Aug 26 13:08:03 2010 josephbUpdateCDSWatch dogs for Vertex optics turned offWe are in the process of doing a damping
test with the real time code and have turned
off the vertex optics watchdogs temporarily,
  
  3474   Thu Aug 26 17:10:26 2010 kiwamuUpdateCDSnew CDS test[Joe, Kiwamu] 
W
  
  3479   Fri Aug 27 14:03:43 2010 kiwamuUpdateCDSWatch dogs for Vertex optics turned offFor
a futher damping test, I again turned off
the vertex optics watchdogs temporarily,
  
  3480   Fri Aug 27 17:27:41 2010 kiwamuUpdateCDSnew CDS test { Joe, Kiwamu }
Yes
  
  3481   Fri Aug 27 19:30:31 2010 ranaUpdateCDSSLOW controlsFor the future SLOW controls our current
plan is to keep using the VME based stuff
and associated processors (Baja, Motorola,
  
  3490   Mon Aug 30 22:45:49 2010 kiwamuUpdateCDSbinary outputs for the new CDS{ Joe and Kiwamu }
Today we made some efforts to
get the binary outputs (BOs) working.
  
  3492   Tue Aug 31 02:50:45 2010 kiwamuUpdateCDSvertex suspensions controlled by the new CDSI plugged the
new CDS to the vertex suspensions.
  
  3494   Tue Aug 31 11:50:14 2010 kiwamuUpdateCDSmaximum number of BIOs { Joe and Kiwamu },
 
  
  3498   Tue Aug 31 16:42:26 2010 josephbUpdateCDSTemporarily reverting to CDS revision 2005Apparently updating to the latest revision
of the RCG has some issues with diaggui and
awgtpman.  Alex had to do some recompiling
  
  3507   Wed Sep 1 12:24:47 2010 josephbUpdateCDSTrying to get up to date CDS code runnningAlex, Joe:
We copied the latest x02 to c1x02
and modified to our the config block in it.
  
  3515   Thu Sep 2 16:45:48 2010 josephbUpdateCDSNumbering scheme of the PCI busRolf has recently written a document describing
how one should fill out an IO chassis and
how the numbering works out.  This can
  
  3516   Thu Sep 2 17:43:30 2010 josephbUpdateCDSOne working BO output module, others not so much Joe and Kiwamu:
We found one bug in the RCG code,
where the second input for the CDO32 part
  
  3527   Mon Sep 6 20:38:58 2010 KojiUpdateCDSSusension model reviewedI have reviewed the suspension model of
C1SUS and refined it.
It is comaptible to the current one
 suspension_model.pdf 
  3528   Mon Sep 6 21:08:44 2010 ranaUpdateCDSSusension model reviewedWe must remember
that we are using the Rev.B
SOS Coil Drivers and not the Rev. A. 
  
  3534   Tue Sep 7 15:31:28 2010 josephb, alexUpdateCDSBinary Output working/ IO chassis fixedAs noted previously,
we were having problems with getting multiple
32 channel binary output cards working. 
  
  3545   Wed Sep 8 11:56:24 2010 kiwamuSummaryCDSSeptember CDS test plan Joe and Kiwamu
We discussed about our CDS plan for
this September. The summary of the plan
  
  3546   Wed Sep 8 14:44:37 2010 josephbUpdateCDSUpdated parse_mdl_to_ipc.py and feCodeGen.plI updated parse_mdl_to_ipc.py to correctly
work with the 3 new cdsIPCx parts, namely
cdsIPCx_PCIE (for dolphin connections), cdsIPCx_RFM
  
  3553   Thu Sep 9 14:42:40 2010 josephbUpdateCDSUpdating suspensions modelI've been working on updating the suspensions
model, incorporating Koji's refinements as
well as trying to simplify the model and
 SingleSUS.png 
  3564   Mon Sep 13 10:22:48 2010 josephbUpdateCDSRCG bugs/feature request wiki pageI've started a wiki page under the Upgrade
09/New CDS section regarding known bugs and
pending feature requests for the Real Time
  
  3576   Wed Sep 15 14:34:57 2010 josephbSummaryCDSPlan for RFM switch overSteps for RFM switch over:
1) Ensure the new frame builder code
is working properly:
  
  3583   Fri Sep 17 12:11:42 2010 josephbUpdateCDSDowns updateIn doing a re-inventory prior to the IOO
chassis installation, I re-discovered we
had a missing interface board that goes in
  
  3584   Fri Sep 17 14:55:01 2010 josephbUpdateCDSTook 5565 RFM card from IOVME to place in the new IOO chassisI took the 5565 RFM card out of the IOVME
machine to so I could put it in the new IO
chassis that will be replacing it. 
  
  3589   Mon Sep 20 11:39:45 2010 josephbUpdateCDSSwitch overI talked to with Alex this morning, discussing
what he needed to do to have a frame builder
running that was compatible with the new
  
  3590   Mon Sep 20 16:59:26 2010 josephbUpdateCDSMegatron in 1X2 rack, to be come c1ioo[Rana, Koji, Joe]
We pulled the phase shifters in the
1X2 rack out to make room for megatron. 
  
  3593   Tue Sep 21 16:05:21 2010 josephbUpdateCDSFirst pass at rack diagramI've made a first pass at a rack diagram
for the 1X1 and 1X2 racks, attached as png.
Gray is old existing boards, power
 1X1_1X2_racks.png 
  3594   Wed Sep 22 16:35:45 2010 josephbUpdateCDSFibers pulled, new FB install tomorrow[Aidan, Tara, Joe]
We pulled out what used to be the
LSC/ASC fiber from the 1Y3 arm rack, and
  
  3600   Thu Sep 23 12:05:20 2010 josephb, alexUpdateCDSfb40m down, new fb in progressAlex came over this morning and we began
work on the frame builder change over. 
This required fb40m be brought down and disconnected
  
  3602   Thu Sep 23 21:01:11 2010 josephb, alexUpdateCDSfb40m still down, new fb still in progressUnfortunately, copying the data to the USB/SATA
drive over at downs took longer than expected
for Alex.  We will be installing the new
  
  3606   Fri Sep 24 22:58:40 2010 josephbUpdateCDSModified front end medm screensTo startup medm screens for the new suspension
front end, do the following:
1) From a control room machine, log
  
  3609   Sun Sep 26 18:29:23 2010 rana, JohnUpdateCDSModified front end medm screensIssues
 megamind-poster3.jpg 
  3612   Mon Sep 27 17:35:13 2010 josephbUpdateCDSUpdated Suspension screens/Megatron now c1ioo/Further work on fbThe medm screens have been updated further,
with the hidden matrices added in bright
colors.  An example screen shot is attached.
 MC1_Example_Screen.png 