40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 38 of 170  Not logged in ELOG logo
Entry  Tue Jun 2 21:22:07 2015, rana, koji, Configuration, IOO, AOM inserted in beam and aligned 
    Reply  Fri Sep 4 10:25:19 2015, Steve, Configuration, IOO, AOM stage is ready stage_AOM-EOM.jpgA-EOMholder.pdf
       Reply  Mon Sep 7 18:25:16 2015, rana, Configuration, IOO, AOM stage is ready 
Entry  Mon Sep 7 16:30:56 2015, rana, HowTo, Computer Scripts / Programs, increase of window border size on Rossa 
Entry  Fri Sep 4 04:05:51 2015, ericq, Update, LSC, DRMI locked on 1F and 3F 
    Reply  Fri Sep 4 15:20:31 2015, ericq, Update, LSC, Vertex Sensing PRFMI_ITM.pdfPRFMI_BS.pdfDRMI.pdfPRFPMI.pdf
    Reply  Fri Sep 4 20:06:23 2015, rana, Update, LSC, DRMI locked on 1F and 3F 
Entry  Tue Sep 1 17:07:06 2015, ericq, Update, LSC, IR beatnote confusion 
    Reply  Tue Sep 1 17:38:58 2015, ericq, Update, LSC, IR beatnote confusion 
       Reply  Wed Sep 2 13:44:04 2015, ericq, Update, LSC, IR beatnote confusion 
          Reply  Thu Sep 3 17:15:26 2015, ericq, Update, LSC, IR beatnote confusion GREENvIRbeats.pdf
             Reply  Fri Sep 4 09:36:48 2015, Steve, Update, LSC, IR beatnote confusion..... 
Entry  Fri Sep 4 00:58:29 2015, rana, Update, CDS, soldering the Generic Pentek interface board 
    Reply  Fri Sep 4 08:00:49 2015, Ignacio, Update, CDS, RC low pass circuit (1s stage) of Pentek board circuit.pdfcircuit.png
       Reply  Fri Sep 4 09:23:32 2015, Ignacio, Update, CDS, Modified Pentek schematic schematic.pdf
Entry  Fri Sep 4 04:12:05 2015, ericq, Update, Computer Scripts / Programs, MATLAB down on all workstations 
Entry  Thu Sep 3 19:52:24 2015, rana, Summary, SUS, SUS drift monitor 07.png
Entry  Mon Aug 24 16:10:07 2015, ericq, Update, SUS, ETMY Oplev laser power is falling ETMYsum_trend.pdf
    Reply  Mon Aug 24 16:46:49 2015, ericq, Update, SUS, ETMY Oplev laser power is falling OLsum_trend.pdf
       Reply  Thu Sep 3 08:53:55 2015, Steve, Update, SUS, ETMY Oplev laser power is falling ETMYoplev2y.png
Entry  Thu Sep 3 02:30:46 2015, rana, Update, CDS, c1cal time reduced by deleting LSC sensing matrix 
Entry  Thu Sep 3 00:45:25 2015, Ignacio, Update, IOO, Remeasured MC2 to MCL TF + Improved subtraction performance 8x
Entry  Thu Sep 3 00:29:45 2015, rana, Update, ASC, ASS X not working 
Entry  Thu Sep 3 00:14:09 2015, rana, Configuration, IOO, IMC fast gain change for lock acq 
Entry  Wed Sep 2 23:50:00 2015, rana, Update, PSL, PMC LO dying PMCLO.png
Entry  Thu Aug 20 02:31:09 2015, ericq, Update, LSC, PRFPMI is back lock.pdf
    Reply  Tue Aug 25 04:15:51 2015, ericq, Update, LSC, PRFPMI is back 
       Reply  Tue Aug 25 16:09:54 2015, ericq, Update, IOO, IMC Tweak imcTweak.pdfCARM_TF.pdf
          Reply  Fri Aug 28 19:05:53 2015, rana, Update, IOO, IMC Tweak 
             Reply  Tue Sep 1 11:56:56 2015, ericq, Update, IOO, IMC loop shapes IMCshapes_Aug31_2015.pdfIMC_Aug31_2015.zip
                Reply  Wed Sep 2 01:31:22 2015, ericq, Update, IOO, IMC loop shapes imc_olg_trend.pdfimc_xover_trend.pdf
       Reply  Thu Aug 27 04:23:04 2015, ericq, Update, LSC, PRFPMI is back 
          Reply  Fri Aug 28 02:20:35 2015, Ignacio, Update, LSC, PRFPMI and MCL FF carmin.pngcarmout.png
Entry  Tue Sep 1 10:26:24 2015, Ignacio, Update, IOO, More MCL Subtractions (Post FF) coherence.pngmclpostwiener.pngmclpostwiener1020.pngmclxycoh.pnguntitled.png
Entry  Tue Sep 1 06:58:11 2015, Ignacio, Update, WienerFiltering, MCL FF => WFS1 and WFS2 FF => ARMS FF 6x
Entry  Tue Sep 1 02:44:44 2015, Koji, Summary, CDS, c1oaf, c1mcs modified for the IMC angular FF c1oaf_screenshot1.pngc1oaf_screenshot2.pngc1mcs_screenshot.pngOAF_MEDM1.pngOAF_MEDM2.png
Entry  Mon Jul 27 16:47:53 2015, ericq, Update, IOO, MC2 -> MCL Actuator TF mc2_2_mcl.pngMC2_2_MCL_TF.txt.zip
    Reply  Thu Jul 30 02:06:20 2015, Ignacio, Update, IOO, MC2 <-> MCL Actuator TF fitted TF_BODE.pngMC2_2_MCL.pngTF_INV_BODE.pngMCL_2_MC2.png
    Reply  Wed Aug 12 22:33:36 2015, Ignacio, Update, IOO, Re-measured MC2 -> MCL TF bode_TF.pngCoherence.png
    Reply  Fri Aug 28 20:15:49 2015, rana, Update, IOO, MC2 -> MCL Actuator TF 
       Reply  Mon Aug 31 07:49:11 2015, ericq, Update, IOO, MC2 -> MCL Actuator TF 
          Reply  Mon Aug 31 14:15:23 2015, Ignacio, Update, IOO, Measured the MC_F whitening poles/zeroes Data.ziptf.png
Entry  Sun Aug 30 23:47:02 2015, Ignacio, Update, IOO, MISO Wiener Filtering of MCL 6x
    Reply  Mon Aug 31 09:36:05 2015, Ignacio, Update, IOO, MISO Wiener Filtering of MCL image1.JPG
Entry  Sat Aug 29 04:53:24 2015, Ignacio, Update, IOO, MCL Wiener Feedforward Final Results 6x
    Reply  Sun Aug 30 00:03:13 2015, rana, Update, IOO, MCL Wiener Feedforward Final Results 
       Reply  Sun Aug 30 10:57:29 2015, Ignacio, Update, IOO, MCL Wiener Feedforward Final Results 
          Reply  Sun Aug 30 12:20:08 2015, ericq, Update, IOO, MCL Wiener Feedforward Final Results 
          Reply  Sun Aug 30 13:31:48 2015, rana, Update, IOO, MCL Wiener Feedforward Final Results 
             Reply  Sun Aug 30 13:55:09 2015, Ignacio, Update, IOO, Summary pages MCF Aug26.pngAug30.png
Entry  Mon Aug 10 22:18:19 2015, Ignacio, Update, IOO, Ready to do some online mode cleaner subtraction stsx.pngperformance.pngfilter.zip
    Reply  Tue Aug 11 11:30:19 2015, Ignacio, Update, IOO, SISO (T240-X) FF of MCL MCL.pngMCTRANS.pngYARM.png
       Reply  Wed Aug 12 01:32:18 2015, Ignacio, Update, IOO, Improved SISO (T240-X) FF of MCL filter.pngstsx.pngmclonline.pngyarmonline.pngsub.png
    Reply  Wed Aug 19 01:45:10 2015, Ignacio, Update, IOO, Doubly Improved SISO (T240-X) FF of MCL 6x
       Reply  Thu Aug 20 11:09:10 2015, rana, Update, IOO, some points about seismic FF 
       Reply  Thu Aug 27 01:41:41 2015, Ignacio, Update, IOO, Triply Improved SISO (T240-X) FF of MCL 1.png2.png4.png5.png3.png
          Reply  Fri Aug 28 00:59:55 2015, Ignacio, Update, IOO, Final SISO FF Wiener Filter for MCL bode.png2.png3.png4.png6.png
Entry  Tue Aug 25 16:39:06 2015, Steve, Update, safety, safety training 
Entry  Tue Aug 25 16:33:31 2015, Ignacio, Steve, Configuration, PEM, Seismometer enclosure copper foil progress picture1.jpgpicture2.jpgIMG_1966.JPGIMG_1969.JPG
Entry  Mon Aug 24 14:05:47 2015, ericq, Update, SUS, EricG Investigating L2A 
Entry  Sat Aug 22 15:48:32 2015, Koji, Summary, LSC, Arm locking recovery 
Entry  Fri Aug 21 08:38:37 2015, Steve, Update, IOO, PMC locked PMClocked.png
Entry  Thu Aug 20 18:08:28 2015, Ignacio, Frogs, 40m upgrading, Fatality. Something broke. image1.JPG
Entry  Thu Aug 13 20:32:07 2015, Ignacio, Update, LSC, Working towards YARM FF  
    Reply  Thu Aug 13 23:57:33 2015, Ignacio, Update, LSC, YARM coherence plots YARM_psd.pngYARM_GUR1_COH.pngYARM_STS_COH.pngYARM_GUR1_COH.png
    Reply  Fri Aug 14 21:40:26 2015, Ignacio, Update, LSC, Quick static offline subtractions of YARM arms_wiener.png
    Reply  Sat Aug 15 02:10:35 2015, Ignacio, Update, LSC, MCL FF => YARM FF YARM_LIVES.png
    Reply  Wed Aug 19 00:55:35 2015, Ignacio, Update, LSC, LSC-YARM-EXC to LSC-YARM-IN1 TF measurement + error analysis master_plot.pngcoherence.png
Entry  Tue Aug 18 03:56:09 2015, ericq, Update, LSC, locking efforts newALSref.pdfxCoh.pdfyCoh.pdf
Entry  Mon Aug 10 15:25:05 2015, Steve, Update, PEM, wasp nest waspN.jpg
    Reply  Tue Aug 11 11:56:36 2015, Ignacio, Jessica, Update, PEM, Wasps obliterated maybe... IMG_1942.JPGIMG_1943.JPGIMG_1944.JPG
       Reply  Mon Aug 17 17:48:12 2015, Koji, Update, PEM, Wasps obliterated maybe... 
Entry  Tue Aug 11 16:13:28 2015, Eve, Update, General, Gaussianity tests 
    Reply  Sun Aug 16 23:26:40 2015, Eve, Update, General, Gaussianity tests Gaussianity_noc1.pngGaussianity_noc1.png
Entry  Fri Aug 14 23:49:34 2015, Koji, Summary, General, B&K Shaker fixed IMG_1947.JPG
Entry  Thu Aug 13 12:06:39 2015, Jessica , Summary, IOO, Better predicted subtraction did not work as well Online 6x
Entry  Wed Aug 12 16:39:46 2015, Ignacio, Update, IOO, MISO WIener (T240-X and T240-Y) FF of MCL 6x
    Reply  Wed Aug 12 16:48:26 2015, Ignacio, Update, IOO, Better? Nope. MISO WIener (T240-X and T240-Y) FF of MCL 6x
Entry  Wed Aug 12 14:35:46 2015, ericq, Update, Computer Scripts / Programs, PDFs in ELOG smooth.pdf
Entry  Tue Aug 11 18:43:42 2015, Jessica, Update, IOO, MCL Online Subtraction SeisX_bode.pngSeisY_bode.pngMCL_first.pngYarm_first.png
Entry  Tue Aug 11 10:13:32 2015, Jessica, Update, General, Conductive SMAs seem to work best best4.pngisolated4.png
Entry  Thu Jul 16 03:01:57 2015, ericq, Update, LSC, Old beatbox hooked back up beat_comparison.pngaLIGO_vs_beatbox.xml.zip
    Reply  Thu Jul 23 03:09:05 2015, ericq, Update, LSC, aLIGO demod board lives! beatbox_vs_aLIGO.png
       Reply  Thu Jul 30 14:42:03 2015, ericq, Update, LSC, aLIGO demod board lives! partialALSbudget.pngdemodDriveLevels.pngALScoherences.pngpartialALSbudget.zip
          Reply  Thu Jul 30 15:58:00 2015, ericq, Update, LSC, Beat note Alignment fluctuation effects measured RF_RIN.pngRF_RINspec.pngRFampCoh.xml.zip
             Reply  Tue Aug 4 03:02:30 2015, ericq, Update, LSC, Beat note Alignment fluctuation effects measured coherences.pnglinX.png
                Reply  Tue Aug 11 02:40:29 2015, ericq, Update, LSC, 50m delay lines - Rough calibrations 
Entry  Thu Aug 6 04:36:41 2015, ericq, Update, ASC, Reviving PRC angular feedforward 
    Reply  Tue Aug 11 02:26:46 2015, ericq, Update, ASC, PRC Angular FF Lives! fitExample.pngFFspectra.pngPITsub.pngYAWsub.png
Entry  Mon Jul 20 11:57:17 2015, ericq, Update, General, Arm Locking recovered 
    Reply  Wed Jul 22 15:09:40 2015, ericq, Update, General, IMC work 
       Reply  Mon Aug 10 11:57:45 2015, ericq, Update, General, IMC work 
Entry  Thu Aug 6 21:03:45 2015, Ignacio, HowTo, WienerFiltering, How to do online static IIR Wiener filtering iir.png
Entry  Thu Aug 6 11:45:01 2015, Jessica, Update, General, ALS Delay Line front panel testing conductive_X.pngconductive_Y.pngisolated_X.pngisolated_Y.png
Entry  Thu Aug 6 01:38:19 2015, ericq, Update, Computer Scripts / Programs, Chiara gets new Ethernet card 
    Reply  Thu Aug 6 09:16:57 2015, Steve, Update, VAC, Chiara gets new Ethernet card ChiaraNetCard.png23.png
Entry  Wed Aug 5 17:15:08 2015, Eve, Update, Summary Pages, Fixed ASC Tab 
Entry  Wed Aug 5 10:56:07 2015, ericq, Update, CDS, Many models crashed  crashes.png
Entry  Mon Aug 3 18:19:09 2015, Jessica, Update, General, Anodization of front panels accounted for redo_conduct1X.pngredo_conduct1Y.png
Entry  Mon Aug 3 08:16:19 2015, Steve, Update, SUS, ETMX damping restored ETMXrestored.png
Entry  Thu Jul 30 19:12:52 2015, Ignacio, Update, IOO, YAW and PIT WFS Wiener filtering YAW.pngPIT.png
Entry  Thu Jul 30 18:58:36 2015, Jessica, Update, General, ALS Delay Line Box Front Panel Testing Xarm_diff.pngYarm_diff.pngXarm_isolated.pngYarm_isolated.png
Entry  Thu Jul 30 14:27:18 2015, Eve, Update, Summary Pages, ALS, ASC, LSC Summary Pages 
ELOG V3.1.3-