  2810   Mon Apr 19 16:31:42 2010 KevinUpdatePSLInnolight 2W LaserKoji and Kevin 
We unpacked the Innolight 2W laser,
took an inventory, and scanned the operations
  
  2811   Tue Apr 20 00:32:30 2010 JenneUpdatePEMGuralp Breakout Box put back


   
        
            
 Gur2X_before_20Apr2010.jpgGur2X_after_replace_100k_resistors_20Apr2010.jpg 
  2812   Tue Apr 20 07:48:42 2010 steveUpdatePSLion pump HV turned onWe found ref-cavity HV was off yesterday
afternoon. It was turned back on.
  
  2813   Tue Apr 20 08:00:52 2010 steveUpdateSUSETMY damping restoredETMY sus damping was restored   
  2816   Tue Apr 20 11:14:31 2010 AidanUpdateGreen LockingRaicol crystals arrived and we investigated them 
 Here
is Crystal 724 polished side 2 with all photos
  
  2817   Tue Apr 20 13:00:52 2010 ZachUpdateelogelog restarted I restarted the elog with the restart
script as it was down.
  
  2818   Tue Apr 20 13:02:14 2010 ZachUpdateGreen Locking1W NPRO output profileEDIT:
I used an IFIT (inverse fast idiot transform)
to change the x-axis of the plot from Hz
 profile_fit_4_19_10.png 
  2819   Tue Apr 20 13:37:36 2010 JenneUpdateGreen Locking1W NPRO output profile


   
        
            
  
  2820   Tue Apr 20 18:02:22 2010 JenneUpdateCOCNew SRM and PRM Hung[Jenne, Steve]
We removed the old SRM and PRM from
their cages, and are temporarily storing
  
  2821   Tue Apr 20 19:37:02 2010 KojiUpdateGreen Locking1W NPRO output profileBeautiful fitting.

  
  2822   Tue Apr 20 20:15:37 2010 KevinUpdatePSLInnolight 2W Output Power vs Injection CurrentKoji and Kevin measured the output power
vs injection current for the Innolight 2W
laser.
 PvsI_2W.jpg 
  2823   Wed Apr 21 10:09:23 2010 kiwamuUpdateGreen Lockingwaist positon of Gaussian beam in PPKTP crystalsTheoretically the waist position of
a Gaussian beam (1064) in our PPKTP crystal
differs by ~6.7 mm from that of the incident
 focal_positin_edit.png 
  2824   Wed Apr 21 11:32:31 2010 josephbUpdateCDS40m CDS hardware update and software requestsThis is mostly a reminder to myself about
what I discussed with Jay and Alex this morning.
The big black IO chassis are "almost"
  
  2825   Wed Apr 21 15:53:57 2010 JenneUpdatePEMSeismometers now on the granite slabThe 3 seismometers are now on the granite
slab.  The Ranger is now aligned with
the Xarm (perpendicular to the Mode Cleaner)
 P4210048.JPG 
  2826   Wed Apr 21 16:48:38 2010 josephbUpdateCDSHardware updateAlberto and myself went to downs and acquired
the 3rd 4x processor (Dual core, so 8x cores
total) computer.  We also retrieved
 irwin.jpg 
  2827   Wed Apr 21 21:46:53 2010 KojiUpdateIOOMC spot diagnosisZach and Koji
We
measured uncalibrated angle-to-length coupling
  
  2828   Wed Apr 21 21:56:27 2010 KevinUpdatePSLInnolight 2W Vertical Beam ProfileKoji and Kevin measured the vertical beam
profile of the Innolight 2W laser at one
point.
 bp2.jpgbp2.dat 
  2829   Wed Apr 21 22:11:48 2010 ranaUpdatePSLInnolight 2W Vertical Beam ProfileBack in Gainesville in 1997, I learned
how to do this using the chopper wheel.
  
  2830   Wed Apr 21 23:35:37 2010 KojiUpdatePSLInnolight 2W Vertical Beam ProfileGood fit. I assumed sqrt(x) is a typo of
sqrt(2).

  
  2832   Thu Apr 22 15:44:34 2010 josephbUpdateComputers I updated the default FILTER.adl file located
in /home/controls/cds/advLigo/src/epics/util/
on megatron.  I moved the yellow ! button
 New_example_CDS_filter.png 
  2833   Thu Apr 22 20:28:40 2010 JenneUpdatePEMSeismometer Noise Characteristics


   
        
            
 Gur1_Gur2_noise.png 
  2834   Thu Apr 22 21:42:24 2010 AlbertoUpdatePSLInnolight 2W Vertical Beam Profile 
 What kind of fit did you use?
How are the uncertainties in the parameters
  
  2836   Fri Apr 23 21:02:14 2010 rana, joeUpdateLSCStarted dev of LSC FEJoe and I started working on the new LSC
FE control today. We made a diagram of the
system in Simulink, but were unable to compile
 Untitled.png 
  2837   Sat Apr 24 15:05:41 2010 KevinUpdatePSL2W Vertical Beam ProfileThe vertical beam profile of the Innolight
2W laser was measured at eight points along
the axis of the laser.
 vbp.jpg 
  2838   Sat Apr 24 15:50:47 2010 KojiUpdatePSLre: 2W Vertical Beam Profile1. The vertical axis should start from
zero. The horizontal axis should be extended
so that it includes the waist. See Zach's
  
  2839   Sun Apr 25 02:56:07 2010 ranaUpdateLSCStarted dev of LSC FELSC
Plant Model. That is all. 
  
  2840   Sun Apr 25 10:40:21 2010 KojiUpdateLSCStarted dev of LSC FEOnce you made a CDS model, please update
the following wiki page.  This will eventually
help you.
  
  2841   Mon Apr 26 10:21:45 2010 josephbUpdateLSCStarted dev of LSC FE

    
        
  
  2843   Mon Apr 26 11:14:04 2010 KojiUpdateGreen LockingTemperature scan for PPKTPI scanned the temperature of the crystal
oven on Friday night in order that we can
find the optimal temperature of the crystal
 SHG_pow.png 
  2844   Mon Apr 26 11:29:37 2010 josephbUpdateComputersUpdated bitwise.pm in RCG SVN plus other fixesTo fix a problem one of the models was
having, I checked the CVS version of the
Bitwise.pm file into the SVN (located in
  
  2845   Mon Apr 26 12:24:58 2010 josephbUpdateGeneralDaily Downs updateTalked with Jay briefly this morning.
We are due another 1-U 4 core (8
CPU) machine, which is one of the ones currently
  
  2846   Mon Apr 26 16:51:37 2010 KevinUpdatePSLre: 2W Vertical Beam ProfileI tried Koji's suggestions for improving
the fit to the vertical beam profile; however,
I could not improve the uncertainties in
  
  2847   Mon Apr 26 17:34:31 2010 KojiUpdatePSLre: 2W Vertical Beam ProfileGive me the plot of the fit, otherwise
I am not convinced.

  
  2848   Mon Apr 26 21:12:53 2010 KojiUpdateSUSPRM/SRM standoffs gluedKiwamu and Koji
The PRM/SRM were balanced with the
standoffs. We glued them to the mirror.
  
  2850   Tue Apr 27 14:18:53 2010 kiwamuUpdateGreen Lockingwaist positon of Gaussian beam in PPKTP crystalsThe mode profile of Gaussian beams in
our PPKTP crystals was calculated.
I
 mode_in_PPKTP.png 
  2851   Tue Apr 27 15:29:16 2010 KevinUpdatePSLre: 2W Vertical Beam ProfileI thought that the micrometer I was using
to move the razor through the laser beam
was metric; however, it is actually english.
 vbp.jpgvbp_residuals.jpg 
  2852   Tue Apr 27 22:28:58 2010 ZachUpdateIOOMC alignmentBeginning last week, I have been helping
Koji with some of the IO work that must be
done for the 40m upgrade. The first thing
 MC_misaligned.png 
  2853   Wed Apr 28 08:55:19 2010 ZachUpdateelogelog restarted Restarted the elog with the script
as it was down.
  
  2854   Wed Apr 28 09:21:16 2010 ZachUpdateelogelog restartedAnd again.


  
  2855   Wed Apr 28 12:05:44 2010 ZachUpdateIOOMC alignmentI have worked out the first set of adjustments
to make on the MC mirrors (all angle figures
are in units of the increments on the control
  
  2856   Wed Apr 28 14:15:58 2010 AlbertoUpdateIOOMC alignment 
 That's interesting.
Would it be possible to write about
  
  2857   Wed Apr 28 14:22:36 2010 KevinUpdatePSLre: 2W Vertical Beam ProfileI used the Mathematica CurveFit package
that we use in Ph6/7 to make the fits for
the beam profile data. I wrote two functions
 BeamFit.nb.tar 
  2858   Wed Apr 28 14:42:55 2010 ZachUpdateIOOMC alignmentSure. I figured I would put up a How-To
if it works. 
  
  2859   Wed Apr 28 16:15:02 2010 KevinUpdatePSLAccelerometer CalibrationKoji, Steve, and Kevin looked into calibrating
the Wilcoxon accelerometers. Once calibrated,
the accelerometers will be used to monitor
  
  2860   Thu Apr 29 14:37:16 2010 josephbUpdateCDSNew Channel Name to Memory Location fileAwhile back we had requested a
feature for the RCG code where a single file
would define a memory location's name as
  
  2861   Thu Apr 29 15:48:47 2010 josephbUpdateCDSNew CDS overview diagram in wikiI've added a diagram in the wiki under
IFO Upgrade 2009-2010->New CDS->Diagram
section Joe_CDS_Plan.pdf (the .svg file I
  
  2862   Fri Apr 30 23:16:51 2010 KojiUpdateSUSSRM/PRM ready for bakingKiwamu and Koji
- Checked the SRM/PRM balancing after
the gluing.
  
  2864   Sun May 2 15:28:25 2010 KojiUpdateIOOSpot Positions of MC1/MC3Summary
The spot positions on the MC mirrors
were measured with coil balance gains.
 spot_position.png 
  2867   Sun May 2 17:16:43 2010 KojiUpdateSUSHow to steer the incident beam to the MC?Deviations of the MC spot from the center
of the mirrors were measured.
MC1H = +0.29 mm
 steering.png 
  2868   Mon May 3 00:36:49 2010 KojiUpdateSUSHow to steer the incident beam to the MC?Actually, I tried some tweaks of the input
steering to get the  beam being more centered
on the MC mirrors on Saturday evening.
  
ELOG V3.1.3-