40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 341 of 344  Not logged in ELOG logo
ID Date Author Type Categorydown Subject Text Attachments
  108   Thu Nov 15 18:36:48 2007 JohnSummary PSL table workI've rotated the lambda/2 plate to 340deg
(from 6 deg) and blocked one arm of the Mach-Zender.
Undo both if you need to.
  
  130   Wed Nov 28 12:43:53 2007 AndreyBureaucracy Here was the PDF-file of my presentation
I was  making a report with powerpoint presentation
during that Wednesday's 40-m meeting.
  
  215   Thu Dec 27 12:12:02 2007 pkpUpdate Update on GigE CameraSo I finally got the linux software to compile
on mafalda. I got the software to dump all
the information regarding the camera onto
  
  254   Wed Jan 23 09:27:55 2008 steveUpdate etmy sus damping restoredSeismis event trips etmy  etmysus.jpg 
  548   Fri Jun 20 02:20:33 2008 YoichiUpdate PMC transmittance degradationThe PMC transmitted light power has been degrading
constantly for last two weeks (see the attachment
1).
 pmc_trans_long_trend.pdfpmc_trans_improvement.pdf 
  563   Wed Jun 25 09:46:45 2008 SharonUpdate Adaptive FiltersI have been learning about different methods
for applying adaptive filters to improve
the Mode Cleaner lock in specific, and other
  
  577   Thu Jun 26 18:29:44 2008 JenneUpdate MC Back onlineJenne, Rob, Yoichi

I was playing with the Mode Cleaner earlier
  
  680   Wed Jul 16 11:26:47 2008 Max JonesUpdate This WeekBaffles. 

I got a battery for the magnetometer today
  
  704   Mon Jul 21 09:52:05 2008 SharonUpdate Adaptive code changesThanks to Alex, we now save the coefficients
of the adaptive filter every cycle. When
we choose ENABLE: OFF on the MEDM screen,
  
  709   Mon Jul 21 19:48:57 2008 SharonUpdate how tp restart C1ASSHow to restart C1ASS:

1. reboot
  
  720   Wed Jul 23 10:47:05 2008 SharonUpdate Weekly updateThis week I spent some time with Alex who
updated the adaptive code to save the filter's
coeffs all the time, stop when I open the
  
  723   Wed Jul 23 13:52:26 2008 SharonUpdate MEDM changesThere is a new MEDM screen now when you go
from c1ass>top>pem.
Instead of having 12 "mini filters" screens
 matrix 
  739   Fri Jul 25 13:30:53 2008 SharonUpdate Changes in ASS computerI editted the simulink diagram of the ASS
computer so it now has 2 more channels reading
2 sets of the FIR coefficients to match Alex's
  
  740   Fri Jul 25 17:32:46 2008 SharonUpdate ASS computerSo, it seems a bit too complicated getting
the coefficients the way I wanted it to happen
(simulink-.ini...). 
  
  747   Mon Jul 28 12:02:32 2008 SharonUpdate accelerometers settingsJenne, Sharon

  
  750   Mon Jul 28 17:58:05 2008 SharonUpdate TOP screen changesI wanted to test the adaptive code with a
downsampling rate of 32 instead of 16. To
do this I entered a 32 Hz ((2048/32)/2 -
  
  760   Tue Jul 29 21:04:55 2008 SharonUpdate OSEM's Power SpectrumFrom 16:30 this afternoon  8x 
  765   Wed Jul 30 12:36:19 2008 SharonUpdate Weekly updateThis week included many computer's issues.
I tested Alex's new C code (the one that
saves the FIR coefficients and restores them
  
  814   Fri Aug 8 11:04:34 2008 SharonUpdate MCL Wiener filterI took some old data from Rana and converted
the units of the Weiner filter to m/m so
to make the effect of the seismometer and
 m_per_m.png 
  841   Fri Aug 15 16:45:43 2008 SharonUpdate Converting from FIR to IIRI have been looking into different techniques
to convert from FIR to IIR. This is so we
can see how effective the adaptive FIR filter
 fir2iir50.pngfir2iir400.pngfir2iir1000.png 
  850   Tue Aug 19 10:36:34 2008 SharonUpdate Calibrating accelerometersI took apart the accelerometers near MC1 and
MC2.
The 2 sets of 3 accelerometers are now covered
  
  854   Tue Aug 19 17:00:19 2008 SharonUpdate Wiener TF calibration - update[I]This is an update for post 814[/I]

I added the calibration gains I got for the
 m_per_m.png 
  855   Tue Aug 19 17:15:34 2008 SharonUpdate MEDMI plugged in the gains I got for the accelerometers
in the accelerometers' filters in the PEM
screen of the adaptive filter
  
  863   Wed Aug 20 17:02:01 2008 SharonUpdate More FIR to IIR I tested another method for converting from
FIR to IIR other than the 2 mentioned in
post 841.
 polefit1.pdf 
  870   Fri Aug 22 13:58:39 2008 SharonSummary Trend of the Wiener TFIn order to understand if we really need an
adaptive filter, I used old data of MC_L
and the accelerometers and seismometer to
 Same_start_time1.pdfsame_length.pdf 
  916   Wed Sep 3 18:45:01 2008 AlbertoConfiguration PD3 gainAlberto, Yoichi,

We found that the PD3 servo was unstable
  
  1442   Mon Mar 30 12:29:17 2009 YoichiConfiguration MC1 glitches not seen during the weekendThe attached is the MC trend for the past
12 hours.
There is no MC1 glitches in the OSEM signals.
 MC_drift.pdf 
  1556   Thu May 7 17:59:23 2009 AlbertoConfiguration MC WFSThis afternoon the MC could not get locked.
I
first checked the Osems values at the MC
mirrors and compared them to the trend of
  
  1739   Mon Jul 13 16:59:10 2009 ZachUpdate GigE Phase CameraToday, I moved the router from on top of
the PSL into the control room in order to
perform dark field tests on the GC650 (which
  
  1797   Mon Jul 27 14:43:34 2009 ChrisUpdate PhotodetectorsI found two ThorLabs PDA55 Si photodetectors
that says detect visible light from DC to
10MHz that I'm going to use from now on. 
  
  1907   Fri Aug 14 18:33:02 2009 ClaraUpdate Record of Accelerometer and Seismometer MovementsRather than make a new elog post every
time I move something, I'm going to just
keep updating this Google spreadsheet, which
  
  2984   Tue May 25 17:04:37 2010 KevinUpdate Beam Profile After Mode CleanerI fit the data from the beam profile that
Jenne measured on 5/21/2010. The distances
are measured from halfway between MC1 and
 mcfit.pngmcerrors.png 
  3027   Tue Jun 1 18:39:59 2010 NancyUpdate Lead spheres for the seismographs 
the lead spheres that were placed
below the granite slab have been  flattened
 P6010170.JPGP6010166.JPGP6010164.JPG 
  3168   Wed Jul 7 12:45:00 2010 nancyUpdate Weekly UpdateWednesday after the meeting - Started report,
learnt mode cleaner locking from Kiwamu and
Rana, saw how to move optics on the tables
  
  3560   Sun Sep 12 23:02:53 2010 valeraUpdate PMC mode matchingKiwamu and I found that the first lens
in the PMC mode matching telescope was mislabeled.
It is supposed to be PLCX-25.4-77.3-C and
 pmc.pdfpmc-abcd.tiff 
  3561   Sun Sep 12 23:16:52 2010 valeraUpdate FSS mode matchingThe attached plot shows the beam scans
of the beam leaking from the back mirror
of the PMC to the BS cube that first turns
 fss.pdffssaom-abcd.tifffssrc-abcd.tiff 
  3562   Mon Sep 13 00:19:32 2010 ranaUpdate VCO Driver Output power v. slider control voltageI measured the RF power output of the VCO
Driver box as a function of slider value.
I measured using the Gigatronics Handheld
 vco.png 
  3579   Wed Sep 15 19:29:13 2010 valeraSummary PSL power budget
    
        

            Location
  
  3580   Fri Sep 17 01:36:14 2010 valeraUpdate PMC line widthThe attached plots show the PMC cavity
line width measurement with 1 mW and 160
mW into the PMC. The two curves on each plot
 TEK00009.PNGTEK00010.PNG 
  3897   Thu Nov 11 15:27:43 2010 valera, steveConfiguration ISS AOM installed We installed the ISS AOM in the PSL.
The AOM was placed right after the EOM. The
beam diameter is ~600 um at the AOM. The
  
  4317   Thu Feb 17 22:51:04 2011 josephb, valeraSummary dither alignment modelWe made a model for the dither angular
stabilization system c1ass.mdl. The attached
file shows the diagram.
 ass-model.png 
  4335   Tue Feb 22 00:18:47 2011 valeraConfiguration c1ioo and c1ass work and related fb crashes/restartsI have been editing and reloading the c1ioo
model last two days. I have restarted the
frame builder several times. After one of
  
  4339   Tue Feb 22 23:11:42 2011 valeraUpdate new medm screens: C1ASS.adl and C1MCASS.adl   C1MCASS.jpegC1ASS.jpeg 
  4345   Wed Feb 23 16:34:42 2011 valeraConfiguration pmc lens stagedI put the PMC last mode matching lens (one
between the steering mirrors) on a translation
stage to facilitate the PMC mode matching.
 PMCrefl.JPGP1070438.JPGP1070439.JPG 
  4625   Wed May 4 13:51:51 2011 valeraConfiguration Intermittent MC3 UL PD signalThe attached plot shows the 30 day trend
of the MC3 UL PD signal. The signal dropped
to zero at some point but now it is close
 mc3ulpdmon.pdf 
  4627   Wed May 4 15:22:39 2011 kiwamuUpdate Re: Intermittent MC3 UL PD signalI
went push all the possible connectors for
the MC3 shadow sensors including the SCSIs,
  
  4959   Mon Jul 11 10:10:31 2011 IshwitaConfiguration AA board The AA board shown in attachment 1 will
be used in the seismometer hardware setup.
A cartoon of this setup is shown in attachment
 P7080305.JPGseismometers.png 
  4999   Wed Jul 20 11:42:47 2011 Ishwita, ManuelUpdate Weekly summary
    We gave a white-board presentation
on derivation of formula for optimum Wiener
filter coefficients and wrote a latex document
  
  5015   Thu Jul 21 23:36:51 2011 JennyUpdate Fitting beam waist with MATLABI am starting work on the PSL table at
the 40m. My goal is to lock  the laser coming
from the nearby table to the FP cavity and
 twobeamfit2.jpg 
  6282   Wed Feb 15 11:34:01 2012 steveUpdate under the shouth end optical tableI added an U channel based bottom shelf
at the south end today.
 P1080535.JPGP1080537.JPG 
ELOG V3.1.3-