New entries since: | Wed Dec 31 16:00:00 1969 | |
Fri Dec 20 23:00:41 2013, Koji, Update, VAC, power supply replaced with a short vent
|
Sat Dec 21 10:53:35 2013, Steve, Update, VAC, power supply replaced with a short vent-pumpdown completed
|
Thu Jan 2 10:50:24 2014, Steve, Update, VAC, vacuum monitor is still blank  
|
Thu Jan 2 13:35:06 2014, Koji, Update, VAC, vacuum monitor is still blank
|
Fri Jan 3 11:18:41 2014, Steve, Summary, VAC, power supply replaced with a short vent
|
Mon Jan 13 16:50:55 2014, Steve, Update, VAC, Maglev controller needs service
|
Tue Jan 21 17:26:59 2014, Jenne, Summary, VAC, Rebooted RGA computer and reset RGA settings
|
Wed Jan 22 15:24:11 2014, Steve, Summary, VAC, Rga scan after reboot 
|
Thu Jan 23 08:04:04 2014, Steve, Update, VAC, vacuum control screen is blank
|
Thu Jan 23 13:23:10 2014, Steve, Update, VAC, 40m IFO is at atmosphere
|
Mon Jan 27 09:08:00 2014, Steve, Update, VAC, 4 days at atmosphere 
|
Tue Jan 28 11:13:50 2014, Koji, Update, VAC, vacuum monitor is still blank
|
Tue Jan 28 16:26:40 2014, Steve, Update, VAC, vacuum computers are back without safety
|
Wed Feb 5 08:14:59 2014, Steve, Update, VAC, vacuum computers are back without safety
|
Wed Feb 5 19:36:50 2014, Steve, Update, VAC, pumpdown at 25 Torr
|
Wed Feb 5 19:53:51 2014, Steve, Update, VAC, pumpdown stops for the day at 14 Torr
|
Thu Feb 6 11:14:07 2014, Steve, Update, VAC, pumpdown completed
|
Mon Feb 10 09:45:53 2014, Steve, Update, VAC, vacuum normal is reached 
|
Tue Feb 11 10:44:15 2014, Steve, Update, VAC, RGA scan at day 6
|
Tue Feb 18 10:38:55 2014, Steve, Update, VAC, RGA scan at day 13 
|
Fri Mar 7 16:13:03 2014, Steve, Update, VAC, pumping speed is recovered
|
Wed Mar 12 08:40:42 2014, Steve, Update, VAC, RGA scan at day 35
|
Mon Mar 24 10:41:46 2014, Steve, Update, VAC, RGA scan at day 50
|
Mon Mar 24 19:42:12 2014, Charles, Frogs, VAC, Power Failure
|
Tue Mar 25 14:52:57 2014, steve, Update, VAC, vacuum is recovered
|
Fri Mar 28 16:26:20 2014, steve, Update, VAC, RGA scan after power failure
|
Wed Apr 2 16:34:15 2014, Steve, Update, VAC, Maglev controller needs service
|
Thu Apr 3 17:05:52 2014, Steve, Update, VAC, Maglev controller swapped
|
Thu Apr 10 16:09:29 2014, Steve, Update, VAC, RGA scan at 75% pumping speed
|
Mon Apr 21 10:14:00 2014, Steve, Update, VAC, Maglev controller serviced
|
Tue Apr 29 16:42:29 2014, Steve, Update, VAC, TP2 drypump replaced
|
Tue May 27 11:00:43 2014, Steve, Update, VAC, RGA scan at day 111
|
Mon Jun 30 10:06:39 2014, Steve, Update, VAC, low on pneumatic pressure of vacuum valves  
|
Wed Jul 2 11:47:26 2014, Steve, Update, VAC, broken changeover regulator of N2 supply
|
Mon Jul 21 10:51:06 2014, Steve, Update, VAC, N2 supply run out
|
Thu Aug 21 15:07:48 2014, Steve, Update, VAC, RGA scan at day 197
|
Mon Sep 22 15:20:32 2014, Steve, Update, VAC, RGA scan at day 229 
|
Wed Sep 24 08:40:29 2014, Steve, Update, VAC, Vent has started 
|
Wed Sep 24 13:28:48 2014, Steve, Update, VAC, vent is completed 
|
Wed Sep 24 16:02:58 2014, Jenne, Update, VAC, vent is completed
|
Thu Sep 25 08:21:15 2014, Steve, Update, VAC, vent day 1
|
Mon Sep 29 09:11:25 2014, Steve, Update, VAC, vent day 5 RGA scan
|
Mon Sep 29 10:29:25 2014, Steve, Update, VAC, RGA is not running
|
Tue Sep 30 16:18:57 2014, Steve, Update, VAC, pump down #78 has started
|
Tue Sep 30 18:02:53 2014, Steve, Update, VAC, pump down #78 stops at 320 Torr
|
Wed Oct 1 10:21:19 2014, Steve, Update, VAC, pump down #78 stops at 3.5 Torr
|
Wed Oct 1 16:26:53 2014, Steve, Update, VAC, pump down #78 completed
|
Thu Oct 2 09:23:23 2014, Steve, Update, VAC, vent 77
|
Fri Oct 3 10:10:37 2014, Steve, Update, VAC, cold cathode gauge reading switched
|
Mon Oct 6 10:23:43 2014, Steve, Update, VAC, Unexpected power shutdown
|
|