40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 340 of 344  Not logged in ELOG logo
Entry  Mon Sep 24 20:28:13 2012, rana, Summary, elog, restarted elog: was unresponsive 
 
Entry  Wed May 15 23:38:04 2013, rana, Update, elog, categories trimmed 
I deleted a bunch of useless categories from the 40m elogd.cfg file. IF you find your category has been deleted, you can now learn how to categorize
yourself into the existing categories. ELOG restarted and log file zeroed.
Entry  Wed Feb 5 18:36:56 2014, rana, Frogs, elog, MicroSoft BingBot is attacking us 
 The ELOG was frozen, with this in the .log file:   
GET /40m/?id=1279&select=1&rsort=Type HTTP/1.1
Cache-Control: no-cache
Entry  Fri Jun 6 14:56:09 2014, ericq, Update, elog, Aaaaaand we're back! 
ELOG is back up and running after last Friday's disk-crash-a-thon. SVN is still a work in progress. Jenne and I are now restarting computers and such.
Entry  Wed Jun 25 01:18:24 2014, Akhil, Update, elog, Weekly Update 
 Plans for the Week:

    Phase and noise characterization of the UFC RF Frequency Counter.
     Characterization of the temperature actuator.

Progress and Problems Faced:
Entry  Wed Jun 25 14:52:22 2014, Andres Medina, Update, elog, Placing a lens between the steering mirrors and another lens between the second steering mirror and the cavity SchematicForXendGreenGoingToTheCavity.pdf
 I was asked to calculate the lenses that we need in order to obtained a Gouy phase close to 90 degrees between the two mirrors that are in the
Xend green. Yesterday, I measured the distances between the mirrors, and the distance between the mirror relative to the cavity as illustrate in the image
attached below. I looked in to the 40m elog and Manasa did the last update on the length of the cavity. She measured 37.7 + 0.05m. The waist size
    Reply  Thu Jul 31 18:54:03 2014, Chris, Frogs, elog, MicroSoft BingBot is attacking us 


    
        
            Quote:
        
        
            

            The ELOG was frozen, with this in the .log file:   
    Reply  Thu Jul 31 21:21:49 2014, Koji, Frogs, elog, MicroSoft BingBot is attacking us 
Oh, this is cool! Thanks!
I could not figure out how to place robot.txt as it was not so obvious how elogd handles the files in the "logfile" directory.
Entry  Mon Dec 22 13:34:34 2014, Koji, Update, elog, Strange ELOG serach 
I tried to find my own entry and faced with a strange behavior of the elog.
The search button invoked the following link and no real search has been done:
http://nodus.ligo.caltech.edu:8080/40m/?mode=summvry&reverse=0&reverse=1&npp=50&m&y&Authorthor=Koji
    Reply  Mon Dec 22 16:21:15 2014, ericq, Update, elog, Strange ELOG search 
In order to fix ELOG search, I have started running ELOG v2.9.2 on Nodus.
Sadly, due to changes in the software, we can no longer use one global write password. Instead, we must now operate
with registered users. 
    Reply  Tue Dec 23 16:49:32 2014, ericq, Update, elog, Strange ELOG search 
 So, despite having registered users, it turns out that the "Author" field is still open for editing when making posts. I.e. we don't
really need to make new accounts for everyone. 
Thus, I've made a user named "elog" with the old write password
Entry  Wed Feb 11 16:49:41 2015, rana, Update, elog, ELOGD restarted 
No elog response from outside and no elogd process on nodus, so I restarted it using 'start-elog.csh'.
Entry  Sun Apr 26 00:08:56 2015, rana, HowTo, elog, Troubles with putting plots in external locations 48.png
If it all possible, don't use links to your home directory. Its not robust. It would be like if you clicked on your Google Music and it told you
to ask me to sing that song to you. Imagine that on auto-repeat next time your fancy-bone itches.
Entry  Sat Mar 26 18:28:24 2016, Koji, Update, elog, elogd flakiness 
Elogd have been restarted several times today because it died everytime I submit something.
Here is the copy of the log.


GET /OMC_Lab/255?cmd=loc&value=Submit HTTP/1.1
Entry  Fri Jan 27 19:40:03 2017, rana, Metaphysics, elog, word wrapping & large images 
"Why does the word wrapping not work in our browsers with ELOG?" I sometimes wonder. Some of the elogs are fine, but often the 40m one has
the text run off the page.

I found that this is due to people
Entry  Tue May 22 17:29:27 2018, keerthana, Update, elog, MEDM Diagram for the auxilary laser system control and display. MEDM_aux.png
(keerthana, gautam, jon)

In the morning, Jon gave me an overview of the Auxiliary laser system which we are planning to setup. Based on the diagram he uploaded in the
elog, I have made the MEDM diagram for controlling and displaying the parameters. Here the parameters which we will be controlling are temperature (in
Entry  Thu Jun 7 14:35:26 2018, keerthana, Update, elog, Table- useful for doing the scanning. 
I think this table will help us to fix the scanning range of the Marconi frequency. This will also help in predicting the position of the resonance peak
corresponding to the injected frequency.

fdiff = fm ±80
Entry  Mon Jun 11 11:45:13 2018, keerthana , Update, elog, Comparison of the analytical and finesse values of TMS and FSR. finesse1.pdf



Quantity
Analytical Value
Finesse Value
Percentage
Error 


Free Spectral range (FSR)
3.893408 MHz
    Reply  Mon Jun 11 18:10:51 2018, Koji , Update, elog, Comparison of the analytical and finesse values of TMS and FSR. 
Hmm? What is the definition of the percentage error? I don't obtain these numbers from the given values.
And how was the finesse value obtained from the simulation result? Then what is the frequency resolution used in Finesse simulation?
    Reply  Mon Jun 11 19:16:49 2018, keerthana, Update, elog, Comparison of the analytical and finesse values of TMS and FSR. fitting_1.pdf
The percentage error which I found out =[(analytical value - finesse value)/analytical value]*100

But inorder to find the finesse value, I just used curser to get the central frequency of each peak and by substracting one from the other I
found TMS and FSR.
    Reply  Mon Jun 11 22:05:03 2018, Koji, Update, elog, Comparison of the analytical and finesse values of TMS and FSR. 
> The percentage error which I found out =[(analytical value - finesse value)/analytical value]*100

Yes, I this does not give us 0.70%

(3.893408 - 3.8863685)/3.893408 *100 = 0.18%
    Reply  Mon Jun 11 22:18:18 2018, keerthana, Update, elog, Comparison of the analytical and finesse values of TMS and FSR. 
Oopss !! I made a mistake while taking the values from my notes. Sorry.




Quote:



> The percentage error which I found out =[(analytical value - finesse value)/analytical value]*100
Entry  Wed Jun 13 11:59:03 2018, keerthana, Update, elog, command line enabled code for frequency scanning 
I have modified the code for frequency scanning and have made it completely command line enabled. The code is written in python. It is saved in the name
"frequency_scanning_argparse.py". I have uploaded it to the Mode-Spectroscopy Github repository.

Inorder to use this code there are two ways.
Entry  Thu Jun 21 13:24:00 2018, keerthana, Update, elog, The cavity scan data of June 20 AS110_Beat.pdfYEND_Beat.pdf
(Jon, Keerthana, Sandrine)

We tried to align the AUX and PSL laser yesterday. We collected the data from the spectrum analyser for the Y-ARM reflection and also for the
Y-ARM transmission from the ETM mirror. I am attaching the plots here.
Entry  Thu Jul 5 17:33:36 2018, keerthana, sandrine, Update, elog, Lights not working 

N/S ARM FL.
N/S ARM INC.


These two lights inside the 40m-lab are not working.
Entry  Thu Jul 5 17:58:04 2018, keerthana, sandrine, Update, elog,  setup1.jpgsetup2.jpg
(Analisa, Sandrine, Keerthana)

Today Annalisa helped us to understand the new set up used to make the frequency scans of the AUX laser. While tracking the cables it seemed
that there were quite a lot of cables near the mixer. So we have reconnected one of the splitter which was splitting the RF out put signal from the Agilent
Entry  Thu Jul 12 14:06:39 2018, keerthana, Update, elog, Finesse and Analytical solution - Comparison finesse_cavity.pngAnalytical1.pdfFinesse_Analytical.pdfDifference.pdf
I tried to compare the cavity scan data we get from the Finesse simulation and that we expect from the Analytical solution. The diagram of the cavity
I defined in Finesse is given below along with the values of different quantities I used. For the analytical solution I have used two different equations
and they are listed below.
Entry  Fri Dec 7 19:42:47 2018, rana, Frogs, elog, can't upgrade DokuWiki because of PHP / SL7 
All of our wikis (except the 40m one which unfortunately got turned into ligo.org mess) use DokuWiki. This now has an auto-upgrade feature through the
Admin web interface.

I tried this recently and it fails with this message:
Entry  Fri Mar 13 12:48:47 2020, Larry Wallace, Update, elog, Cert Renewal 
Updated the cert in /etc/httpd/ssl. The new cert is good until March 12, 2022.
Entry  Fri Apr 16 11:31:00 2021, rana, Update, elog, elog stuck ~10 AM today 
found it unresponsive. Restarted fine using procedure documented in wiki
    Reply  Tue May 21 17:03:45 2013, Steve, Update, endtable upgrade, enclosure tops are sealed  ETMYoptable.jpgsurgtubclamps.jpgquickrelease.jpgreinforcbridge.jpg


    
        
            Quote:
        
        
            

            
    Reply  Thu May 23 12:02:48 2013, Steve, Update, endtable upgrade, ETMY - oplev ETMYopl.jpg
 Temporary oplev in place. The spot on the qpd is still big. My two lens solution did not work.
I will finalize optical component position of the oplev after the the arm transmitted and green beam optics in place. They have priority.
 
    Reply  Thu May 30 11:10:00 2013, Steve, Update, endtable upgrade, ETMY - oplev ETMYoplev.jpg


    
        
            Quote:
        
        
            

            Temporary oplev in place. The spot on the qpd is still big. My two lens solution did not work.
    Reply  Thu May 30 20:45:53 2013, Annalisa, Update, endtable upgrade, ETMY - oplev 


    
        
            Quote:
        
        
            

           
            
                
           
    Reply  Fri May 31 11:15:01 2013, Annalisa, Update, endtable upgrade, ETMY - Mode Matching for green - new calculation 
 Since the beam waist after the Faraday had changed since the last time I measured it (maybe alignment changed a bit), I made a new mode matching
calculation for green. I attached the results.
I'm going to align the beam into the Yarm.
Entry  Tue Jun 4 10:44:13 2013, Steve, Update, endtable upgrade, PI pzt holders are ready PIpztholders.jpg
The PI pzt holders are back from the shop. They are numbered 1, 2 & 3 and machined to match.
Tapered black delrin opener is to gauge the gap if it is too small to fit pzt. This is to prevent holder to be opened too much.
    Reply  Thu Jun 6 09:58:13 2013, Steve, Update, endtable upgrade, enclosure to chamber connection thinwallconnector.jpg06061301.PDF
 
 Thin wall connector from McMCarr#55275K25 was tested in 150 mW, 1 mm beam
size of 1064 nm  overnight. It did not show any degradation.
Entry  Tue Jun 25 19:18:07 2013, gautam, Configuration, endtable upgrade, plan of action for PZT installation 
  This entry is meant to be a sort of inventory check and a tentative plan-of-action
for the installation of the PZT mounted mirrors and associated electronics on the Y-endtable. 
Hardware details:
    Reply  Wed Jul 3 21:19:04 2013, gautam, Configuration, endtable upgrade, plan of action for PZT installation DAC_bank.pngASC_schematic.pdf
 This is an update on the situation as far as PZT installation is concerned. I measured the required cable (PZT driver board to PZT) lengths for
the X and Y ends as well as the PSL table once again, with the help of a 3m long BNC cable, just to make sure we had the lengths right. The quoted cable
lengths include a meter tolerance. The PZTs themselves have cable lengths of 1.5m, though I have assumed that this will be used on the tables themselves.
    Reply  Mon Jul 8 13:45:19 2013, gautam, Configuration, endtable upgrade, Driver board verification 
With the help of an expansion card,  I verified that the + 15V and + 24V from the eurocrate in the slot I've identified
for the PZT driver boards are making their way to the board. The slot is at the right-most end of the eurocrate in 1Y4, and the rack door was getting in
the way of directly measuring these voltages once I hooked up the driver board to the expansion card. So I just made sure that all the LEDs on the expansion
    Reply  Wed Jul 10 22:41:06 2013, gautam, Configuration, endtable upgrade, PZT Driver Board HV_Amplifier.pdf
 I did the following with the PZT Driver Board: 
Entry  Thu Jul 11 09:15:10 2013, Steve, Update, endtable upgrade, ETMY optable grounded 
ETMY optical table top was grounded to the ETMY chamber through 1 Mohms this morning. I  also strain releifed relieved a few cables
that were pulling on components directly.
    Reply  Mon Jul 15 11:51:18 2013, gautam, Configuration, endtable upgrade, DAC at 1Y4-Max Output and Power Spectrum max_amp.JPGmax_amp_all_channels.JPGDACOffPowerSpec.pdfDACOnPowerSpec.pdfDAC2kPowerSpectrum.pdf
 Summary:
I measured the maximum output of the DAC at 1Y4 as well as its power spectrum. The results are as follows (plots below):

    Maximum amplitude of differential output: + 10V.
    Power spectrum has a peak at 64 kHz.

Therefore,
    Reply  Mon Jul 15 13:51:17 2013, Koji, Configuration, endtable upgrade, DAC at 1Y4-Max Output and Power Spectrum 
We need the unit of the voltage power spectrum density to be V/sqrt(Hz).
Otherwise we don't understand anything / any number from the plot.
    Reply  Mon Jul 15 15:54:20 2013, gautam, Configuration, endtable upgrade, DAC at 1Y4- Power Spectrum -with the right units DACOffPSD.pdfDAC500PSD.pdfDAC2000PSD.pdf


    
        
            Quote:
        
        
            

           We need the unit of the voltage power spectrum density to be V/sqrt(Hz).
    Reply  Mon Jul 15 17:20:43 2013, Jenne, Configuration, endtable upgrade, DAC at 1Y4- Power Spectrum -with the right units 
Those 'peaks' for the oscillations seem ridiculously broad.  I think you should look again, really quickly, with smaller bandwidth at, say, the
2kHz oscillation, to make sure it looks reasonable.
    Reply  Mon Jul 15 17:59:31 2013, gautam, Configuration, endtable upgrade, DAC at 1Y4- Power Spectrum -6.4kHz bandwidth DAC-6.4_kHz_BW_PSD.pdf


    
        
            Quote:
        
        
            

           Those 'peaks' for the oscillations seem ridiculously broad.  I think you should look again, really quickly, with smaller bandwidth at,
    Reply  Tue Jul 16 14:51:09 2013, gautam, Configuration, endtable upgrade, AI Board-D000186-Modified notches D000186_Frequency_Response.pdf
 I tried shifting the notch frequencies on the D000186-revision D board given to me by Koji. The existing notches were at ~16 kHz and ~32 kHz. I
shifted these to notches at ~64 kHz and ~128 kHz by effecting the following changes (see schematic for
component numbering) on Channel 8 of the board-I decided to check things out on one channel before implementing changes en masse:
    Reply  Thu Jul 18 19:09:08 2013, gautam, Configuration, endtable upgrade, QPD Calibration for PZT Calibration QPD-XCalib.pdfQPD-YCalib.pdfError_Function_Fitting.zip
Summary 
I have been working on setting up a QPD which can eventually be used to calibrate the PZT, and also orient the PZT in the mount such that the pitch
and yaw axes roughly coincide with the vertical and horizontal.
    Reply  Thu Jul 18 20:20:52 2013, gautam, Configuration, endtable upgrade, First mirror glued to PZT and mounted in modified mounts Piezo-mirror.jpg
 
 Yesterday, I mounted the first PZT in one of the modified mounts, and then glued a 2-inch Y2 mirror on it using
ELOG V3.1.3-