ID |
Date |
Author |
Type |
Category |
Subject |
Text |
 |
6185
|
Wed Jan 11 14:06:28 2012 |
Leo Singer | HowTo | Computer Scripts / Programs | HowTo for getting data from NDS off site | This may or may not be general knowledge
already, but Jamie and I added a HowTo explaining
how to retrieve channel data from the frame |
|
6383
|
Wed Mar 7 23:28:41 2012 |
Lab Cleanup Crew | HowTo | Environment | True Beauty.... | Or,
how a lab should
look at the end of every day. |
|
6389
|
Fri Mar 9 10:17:06 2012 |
steve | HowTo | PEM | do not leave tables open | Type: How not to
Please do not leave optical tables
open! You will be held responsible for creating |
|
6399
|
Sat Mar 10 15:29:47 2012 |
Zach | HowTo | Computer Scripts / Programs | ModeMatchr | For your mode matching pleasure, I |
|
6415
|
Wed Mar 14 13:27:15 2012 |
Zach | HowTo | Computer Scripts / Programs | ModeMatchr | I have added to ModeMatchr the capability |
|
6442
|
Sun Mar 25 20:13:31 2012 |
rana | HowTo | SUS | Optical Lever Servo Tuning thoughts | To start the optical lever filter design,
I looked into the noise on ITMY. It should
be similar to the other arm cavity optics |
|
6637
|
Thu May 10 14:49:06 2012 |
Koji | HowTo | General | How to clean & bake black glass pieces | |
|
6833
|
Tue Jun 19 20:26:50 2012 |
Jenne | HowTo | Locking | Summer Plan | Jenne and Yuta's
Summer Plan |
|
7746
|
Mon Nov 26 18:56:34 2012 |
Jenne | HowTo | Computers | Data logging suggestions | We've been talking for a while about how
we want to store data. I'm not in love
with keeping it on the elog, although I think |
|
7747
|
Mon Nov 26 19:27:59 2012 |
Riju | HowTo | | Testing AG4395A+GPIB | Riju, Jenne
We have checked the transfer function
of a bandpass filter using AG4395A network |
 |
7765
|
Fri Nov 30 09:59:53 2012 |
Steve | HowTo | General | How not to | Clean cabinet S15 doors were left open.
You have to lock it up! |
|
7768
|
Fri Nov 30 14:21:18 2012 |
rana | HowTo | Computer Scripts / Programs | The mystery of PDFs and you. As deep as the mystery of Rasputin. | |
|
7776
|
Mon Dec 3 07:40:00 2012 |
Steve | HowTo | Alignment | how was the BS chamber misalinged |
|
|
7794
|
Wed Dec 5 17:38:41 2012 |
Riju | HowTo | | Photodiode transimpedance | I have started making the circuit to measure
the transimpedance for the photodiode PDA10CF
using Jenne's laser. I will continue it tomorrow. |
|
7807
|
Tue Dec 11 08:53:52 2012 |
Steve | HowTo | PEM | cables needs care | How NOT
to:
The |
|
7809
|
Tue Dec 11 10:09:04 2012 |
Ayaka | HowTo | PEM | cables needs care |
|
|
7872
|
Wed Jan 2 15:33:23 2013 |
Jenne | HowTo | Locking | We should retry in-air locking | Immediate things to do include finishing
installation of new TTs and re-routing of
oplev paths in the BS chamber, but after |
|
7873
|
Thu Jan 3 19:19:59 2013 |
rana | HowTo | Electronics | cable racks | Today I found 3 power cables in the
orange Pomona cable tray, put in
so that the cables were |
|
7877
|
Mon Jan 7 00:08:16 2013 |
Jenne | HowTo | Alignment | In-vac plan | List of things to do, in order:
* Remove BS heavy door.
Steve, |
|
8190
|
Wed Feb 27 19:27:29 2013 |
Annalisa | HowTo | COMSOL Tips | Mirror support Eigenfrequency | I studied the eigenfrequencies of
a mirror support using COMSOL.
|
 |
8226
|
Mon Mar 4 20:03:42 2013 |
Annalisa | HowTo | COMSOL Tips | Study of mirror mount eigenfrequencies | I studied the eigenfrequencies of
a mirror mount designed with COMSOL.
I imposed fixed constraints for the |
   |
8231
|
Tue Mar 5 14:59:32 2013 |
Steve | HowTo | VAC | dry-forepump replaced | TP3 turbo pump's dry-foreline pump was
replaced.
How to do it: |
 |
8265
|
Sun Mar 10 13:29:29 2013 |
Koji | HowTo | IOO | How to calculate the accumulated round-trip Gouy phase | How to calculate the accumulated round-trip
Gouy phase (and namely the transverse mode
spacing) of a general cavity |
|
8441
|
Thu Apr 11 03:25:29 2013 |
Jenne | HowTo | SUS | Idea for how to properly balance SUS actuators | We have calibrated the overall actuators of
each suspension independent of the optical
levers. So, we know how much we are
|
|
8919
|
Wed Jul 24 19:21:56 2013 |
Jamie | HowTo | SUS | SUS MEDM screen modernization | I started poking around at what we want
for new SUS MEDM screens. Rana and
I decided we'd start with the ASC TIPTILT |
|
9005
|
Tue Aug 13 11:54:40 2013 |
Alex Cole | HowTo | Electronics | RF PD Fiber-Coupled Laser Operation | This post pertains to the fiber-coupled
diode laser mounted in rack 1Y1.
To turn the laser on, first turn |
|
9027
|
Mon Aug 19 10:03:17 2013 |
Steve | HowTo | General | how not to leave a cable | We can not leave cables connected like
this. This is a burned toast award. |
|
9059
|
Fri Aug 23 21:01:38 2013 |
Alex Cole | HowTo | Electronics | Automated Photodetector Frequency Response System | This post describes how to use the
Automated Photodetector Frequency Response
System. |
|
9093
|
Mon Sep 2 03:51:14 2013 |
rana | HowTo | General | How To Coil Cables | http://youtu.be/pEd7ru24Vx0 |
|
9097
|
Tue Sep 3 10:54:33 2013 |
Steve | HowTo | General | How To Coil Cables |
|
|
9187
|
Thu Oct 3 00:01:59 2013 |
rana, jenne | HowTo | LSC | steps to full IFO | In moving now to full |
|
9189
|
Thu Oct 3 01:18:57 2013 |
Koji | HowTo | LSC | steps to full IFO | I vote on PRMI+1arm -> PRFPMI |
|
9219
|
Tue Oct 8 00:21:01 2013 |
manasa | HowTo | Green Locking | ALS arm stabilization | Step by
step procedure for stabilizing arms using
ALS servo |
|
9305
|
Mon Oct 28 18:57:27 2013 |
Masayuki | HowTo | LSC | read 'scope and spectrum analyser datas |
The
command to get the data from spectrum analyzer |
|
9318
|
Wed Oct 30 08:32:55 2013 |
Evan | HowTo | Computer Scripts / Programs | matplotlibrc | FYI, you can trick out matplotlib by creating
a matplotlibrc config |
|
9319
|
Wed Oct 30 14:58:44 2013 |
Steve | HowTo | General | shutting down a computer |
We have tried to ssh into c1iscey
yesterday morning. It just did not work. |
|
9573
|
Fri Jan 24 12:44:25 2014 |
Gabriele | HowTo | LSC | Procedure to measure PRC length | Here is how to measure the PRC length with
a set of distance measurements in the optical
setup. |
8x |
9574
|
Fri Jan 24 13:10:12 2014 |
Jamie | HowTo | LSC | Procedure to measure PRC length |
|
|
9575
|
Sat Jan 25 21:09:16 2014 |
gabriele | HowTo | LSC | Procedure to measure PRC length | I know the drawing is wrong.
I put random distances, not realistic ones,
and I did not try to get something close |
|
9578
|
Mon Jan 27 17:49:46 2014 |
rana | HowTo | Computer Scripts / Programs | sendmail started on nodus: fixing SwiftMail on Dokuwiki | Since the recent filesystem fracas, the
new accounts could not be created on nodus
/ dokuwiki (for the controls workshop, for |
|
9744
|
Sun Mar 23 14:20:07 2014 |
rana | HowTo | LSC | BLRMS screens | We should make screens like this
for the LSC signals, errors, ALS, etc. |
|
9885
|
Wed Apr 30 21:31:25 2014 |
rana | HowTo | IOO | Mystery Alignment again | Looks like there was some mysterious MC
alignment shift around 5:30 PM today, but
no elog.....?? Now things are drifting much |
|
9944
|
Tue May 13 00:46:58 2014 |
rana | HowTo | PSL | PMC relocking | The PMC runs out of range sometimes due
to the daily temperature swing. The voltage
swings up after sunset and then starts to |
|
10014
|
Mon Jun 9 20:07:53 2014 |
nicolas | HowTo | Computer Scripts / Programs | Latex (math) in the elog |
|
|
10086
|
Sat Jun 21 01:25:12 2014 |
Nichin | HowTo | Electronics | PD Trasimpedence measurement theory | Here
is the logic that I have been using to calculate
the transimpedence of PDs. Please let me |
|
10152
|
Tue Jul 8 15:07:24 2014 |
Nichin | HowTo | Electronics | RF Multiplexer in rack 1Y1 | The RF
multiplexer is configured as shown in the
figure. It is now effectively a 15x1 RF mux. |
|
10210
|
Wed Jul 16 01:27:01 2014 |
Nichin | HowTo | Computer Scripts / Programs | HP8591E spectrum analyzer remote scan | The script for running continuous scans
on HP 8591E spectrum analyzer is located
at scripts/general/netgpibdata |
|
10381
|
Wed Aug 13 23:58:49 2014 |
rana | HowTo | Computer Scripts / Programs | HP8591E spectrum analyzer remote scan |
|
|
10391
|
Thu Aug 14 19:23:25 2014 |
rana | HowTo | IOO | How do I set the FSS offset to make the PZT voltage start at the right place? | When the IMC locks, we want the FAST
OUT of the TTFSS box to be close to zero
volts. We also want the control signal from |
|
10473
|
Mon Sep 8 16:23:25 2014 |
Larry | HowTo | Computer Scripts / Programs | accessing 40m data remotely with python |
Attached is an example script showing
how to access 40m data remotely. The only |
|