40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 339 of 344  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
Entry  Thu Nov 18 00:40:31 2010, yuta, Update, IOO, PRM reflected beam reached AP table 
Entry  Thu Nov 18 16:32:21 2010, yuta, Summary, CDS, current damping status for all optics c1sus handles c1susdampings.png
Entry  Fri Nov 19 17:12:22 2010, yuta, Update, CDS, ETMX damped, but with weird TO_COIL matrix ETMXdamping.png
Entry  Sat Nov 20 01:58:56 2010, yuta, HowTo, CDS, editting RT models and MEDM screens 
Entry  Sat Nov 20 02:25:30 2010, yuta, Update, CDS, 2 LOCKINs for suspension models LockinRoll.png
   +  Reply  Sat Nov 20 03:37:11 2010, yuta, Summary, CDS, CDS time delay measurement - the ripple c1tst16Kdelay.png
Entry  Mon May 21 21:27:39 2012, yuta, Update, CDS, MEDM suspension screens using macro 
   +  Reply  Tue May 22 20:46:38 2012, yuta, Update, CDS, MEDM suspension screens using macro 
Entry  Thu May 24 16:13:05 2012, yuta, Update, Computers, ASS scripts on new ubuntu machines 
   +  Reply  Tue May 29 21:05:30 2012, yuta, Update, IOO, PMC, MC alignment are shit 
Entry  Wed May 30 01:35:15 2012, yuta, Update, Green Locking, aligned Y arm green beam 
Entry  Wed May 30 15:51:22 2012, yuta, Update, IOO, MC beam spot oscillation specMC3_onoff_localdamping.pdf
   +  Reply  Wed May 30 19:27:38 2012, yuta, Update, IOO, MC beam spot oscillation 
Entry  Thu May 31 01:27:16 2012, yuta, Update, Green Locking, PSL and Y arm green beams aligned 
Entry  Thu May 31 01:36:17 2012, yuta, Update, Green Locking, GREEN_TRX/GREEN_TRY PDs 
Entry  Thu May 31 02:27:24 2012, yuta, Update, IOO, script for reliefing MC WFS 
Entry  Thu May 31 04:03:17 2012, yuta, Update, IOO, script for MC beam spot measurement 
Entry  Thu May 31 16:19:07 2012, yuta, Update, Green Locking, temperature setting for PSL doubling crystal 
Entry  Sat Jun 2 03:19:37 2012, yuta, Update, Green Locking, Y green beat note found? - too small CIMG1437.JPG
Entry  Tue Jun 5 21:09:40 2012, yuta, Update, Computer Scripts / Programs, hacked ezca tools 
Entry  Wed Jun 6 02:28:02 2012, yuta, Update, Green Locking, tried to see Yarm length change with weak beat note beatycoarseringdown20120605.pngbeatysetup20120605.png
Entry  Wed Jun 6 15:16:00 2012, yuta, Update, IOO, MC WFS offsets adjusted 
Entry  Wed Jun 6 21:11:45 2012, yuta, Update, Green Locking, improved Y arm green alignment beatygreenpower20120606.png
Entry  Thu Jun 7 01:46:05 2012, yuta, Summary, Green Locking, Y green beat - found it!! CIMG1504.JPG
   +  Reply  Thu Jun 7 02:25:27 2012, yuta, Update, Green Locking, improved Y arm green alignment - even more beatygreenpower20120607.png
   +  Reply  Thu Jun 7 02:59:31 2012, yuta, Update, Green Locking, Y green beat - found it!! 
Entry  Thu Jun 7 03:37:26 2012, yuta, Update, CDS, mx_stream restarted on c1lsc, c1ioo  
Entry  Thu Jun 7 05:39:41 2012, yuta, Update, Green Locking, coarsely stabilized Y arm length with ALS MyFirstALS20120607.png
   +  Reply  Thu Jun 7 18:46:13 2012, yuta, Update, SUS, PRM oplev centered 
Entry  Fri Jun 8 15:08:27 2012, yuta, Update, Green Locking, aligned/mode-matched Y green beat setup 
Entry  Mon Jun 11 21:50:08 2012, yuta, Update, Green Locking, beatbox looks OK CIMG1522.JPG
Entry  Tue Jun 12 01:58:33 2012, yuta, Update, Green Locking, aligned Y arm to Y end green 
   +  Reply  Tue Jun 12 20:35:46 2012, yuta, Update, Green Locking, c1gcv recompiled c1gcv20120612-2.png
Entry  Tue Jun 12 23:18:18 2012, yuta, Update, Green Locking, I-Q signals for the beat FINEIQplot20120612.pngCOARSEIQplot20120612.pngbeatysetup20120612.png
Entry  Wed Jun 13 02:11:59 2012, yuta, Update, Green Locking, my first modescan (sort of) modescan20120612_1.png
   +  Reply  Wed Jun 13 03:03:38 2012, yuta, Update, Green Locking, my first modescan (sort of) 
Entry  Wed Jun 13 17:39:13 2012, yuta, Update, Green Locking, calibrating the beatbox ALS-BEATY_COARSE_I_IN1_DQ.pngALS-BEATY_COARSE_Q_IN1_DQ.pngALS-BEATY_FINE_I_IN1_DQ.pngALS-BEATY_FINE_Q_IN1_DQ.png
Entry  Thu Jun 14 01:36:34 2012, yuta, Update, Green Locking, can't scan Y arm for 1FSR BEATY_COARSE_LoopOnOff.png
Entry  Thu Jun 14 04:53:39 2012, yuta, Summary, Green Locking, designing ALS loop for mode scan ALSloop.pngALSopenloop.pngyarmlength.png
Entry  Thu Jun 14 21:37:37 2012, yuta, Update, Green Locking, succeeded in 1FSR mode scan YarmScan20120614.png
   +  Reply  Fri Jun 15 00:50:54 2012, yuta, Update, Green Locking, scanned Y arm for 5FSR YarmScan20120614_2.png
Entry  Fri Jun 15 13:33:39 2012, yuta, Update, Green Locking, ADC noise contribution to ALS YarmALSnoise20120615.png
Entry  Sat Jun 16 01:03:21 2012, yuta, Update, Green Locking, used longer delay line for mode scan YarmScan20120615.png
   +  Reply  Sat Jun 16 13:01:17 2012, yuta, Update, Green Locking, scanned Y arm for 5FSR YarmScanDV.png
   +  Reply  Sat Jun 16 18:17:00 2012, yuta, Update, Green Locking, Y arm length using 5FSR scan ALS-BEATY_COARSE_I_IN1_DQ.pngCalibYarmScan20120614_2.png
   +  Reply  Sat Jun 16 19:32:11 2012, yuta, Update, Green Locking, Y arm length using 5FSR scan 
Entry  Mon Jun 18 02:31:43 2012, yuta, Summary, Green Locking, analysis of mode scan data coarse5FSRscan.pngfine1FSRscan.pngHOMRFSB.pngcoarse5FSRscanHOMRFSB.png
Entry  Mon Jun 18 17:28:03 2012, yuta, Summary, Computers, bugs in CDS_PARTS/simLinkParts/Fcn model_sindegbug.pngdv_sindegbug.png
Entry  Mon Jun 18 23:54:31 2012, yuta, Update, Green Locking, phase tracker for ALS newIQLOCK.pngYarmScan20120618.pngfine8FSRscan.png
Entry  Tue Jun 19 23:36:19 2012, yuta, Update, LSC, calibrated POY error signal LSCyarmTF_usingITMY.pngLSCyarm_HAover1plusG.pngPOYerrorcalibration.png
ELOG V3.1.3-