40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 339 of 344  Not logged in ELOG logo
New entries since:Wed Dec 31 16:00:00 1969
    Reply  Tue Jan 19 00:10:44 2010, rana, Update, Electronics, triple resonant circuit for EOM 
Very cool.  
      
    Reply  Tue Jan 19 02:40:38 2010, Koji, Update, Electronics, triple resonant circuit for EOM 
The design looks very good. I have some questions.
1. As far as I remember, you've got the gain of slightly worse than 10 for a 55MHz single resonant case. Why your expectation of the gain (G=11)
for the highest resonance better than this?
    Reply  Tue Jan 19 03:04:14 2010, Koji, Update, Electronics, triple resonant circuit for EOM 
Self-follow:
I got the answer of Q3 from the follow-up entry.
For Q4, once you get the impedance of the LC network lower than n^2*50, the EOM gain will be quite low. This means that the resonance is anyway
Entry  Tue Aug 24 11:23:32 2010, steve, Update, PEM, tripod leg installation completed 7x
Bertine Robby, Bertin and Jerry completed the installation by pouring concrete yesterday and cleaning up today.
Atm1-2, steel bars, grouted feet and side forms are ready
Atm3,    bounding agent is applied for better bounding
Entry  Wed Jan 16 14:09:45 2008, rob, Update, LSC, tuesday's locking 

I got a little further with the locking (PRFPMI) last night, after discovering that the cable going from the CM board to the MC board was unplugged at
the MC side.  This explains why we weren't able to engage the AO path last night.  Tonight, I got up to the point where DARM is handed off to OMC transmission,
Entry  Thu Apr 9 12:23:49 2009, pete, Update, Locking, tuning ETM common mode FPMI-DARM-CARM-ETM-fineScan.pdf
Pete, Yoichi
Last night, we put the IFO in FP Michelson configuration.  We took transfer functions of CARM and DARM, first using CM excitations directly
on the ETMs, and then using modulations of the laser frequency via MC excitation.  We found that there was basically no coupling into DARM using the
    Reply  Tue Jul 25 14:04:06 2017, Steve, Update, VAC, turbo controller installed and we are running at vac normal TP2@75Krpm.png
Gautam and Steve,

Spare Varian turbo-V 70 controller, Model 969-9505, sn 21612 was swapped in. It is running the turbo fine @ 50Krpm but it does not allow it's
V4 valve to be opened............
Entry  Wed Mar 30 16:57:13 2011, kiwamu, Update, General, turned off c1aux  
[Steve / Kiwamu]
 As a part of the video cable session, we reconnected some power cords on 1Y1 rack.
During the work we momentarily turned off c1aux, which handles DMF, Illumintators, mechanical shutters and the old video epics.
Entry  Tue Jan 5 13:23:45 2010, Alberto, Omnistructure, Environment, turning page 
In the lab there are lots of old posters with outdated autocad drawings, or printouts with schematics of old electronics hanging on the walls.
Can we get rid of those and start giving the lab a fresh and modern look?
Entry  Mon Jan 28 21:32:38 2013, jamie, Update, Alignment, tweaking of alignment into half PRC 
[Koji, Jamie]
We tweaked up the alignment of the half PRC a bit.  Koji started by looking at the REFL and POP DC powers as a function of TT2 and PRM alignment. 
    Reply  Wed Mar 24 04:22:51 2010, kiwamu, matt, Update, Green Locking, two NPRO PLL  
Now some pedestals, mirrors and lenses are left on the PSL table, since we are on the middle way to construct a PLL setup which employs two NPROs instead
of use of PSL laser.
So Please Don't steal any of them.
    Reply  Wed Mar 24 14:52:02 2010, Alberto, Update, Green Locking, two NPRO PLL  


    
        
            Quote:
        
        
            
            Now some pedestals, mirrors and lenses are left on the PSL table, since we are on the middle way to construct a PLL
Entry  Fri Jun 22 20:00:14 2012, Jamie, Omnistructure, Electronics, two RG-405 cables ran from 1X2 rack to control room 
[Yaakov, Eric, Jenne, Yuta]
Two of our surfs, Yaakov and Eric, pulled two unused RG-405/SMA cables that had been running from 1X2 to (mysteriously) 1Y2 racks.  They left
the 1X2 end where it was and pulled the 1Y2 end and rerouted it to the control room.  We labeled both ends appropriately.
    Reply  Fri Apr 1 23:49:24 2011, kiwamu, Summary, Green Locking, two states in green beat-note 
According to the measurement done by Aidan and me, there are two beat-note state.
One gave us a small beat signal and the other gave us a bigger signal by approximately 20 dB.
 
Entry  Wed Aug 27 18:03:47 2014, ericq, Update, Green Locking, uPDH Box Checkup uPDH_X.JPGuPDH_Y.JPGupdhTFs.pdfupdhNoises.pdfuPDH_Aug27.zip
 Quick post of plots and data; I'll fill in more detail tonight. 
TL;DR: I pulled both green PDH boxes and made LISO models, compared TFs and noise levels. 

Pictures of X and Y boards, respectively
    Reply  Thu Aug 28 17:34:20 2014, ericq, Update, Green Locking, uPDH Box Checkup TEK00006.PNG
I had noticed in the past, that the digital control signal monitor for the X end would saturate well before the ADC should saturate (C1:ALS-X_SLOW_SERVO_IN1,
which is from the "output mon" BNC on the box). It turns out that there is some odd saturation happening inside the box itself.
In this scope trace, the servo input is being driven with a 0.02Vpp, 0.1Hz sine wave, gain knob at 1.0. This is bad. 
    Reply  Fri Aug 29 17:28:07 2014, rana, Update, Green Locking, uPDH Box Checkup 
 
 I've been having trouble locking
the X - green for the past few hours. Has there been some configuration change down there that anyone knows about?
    Reply  Fri Aug 29 23:53:35 2014, ericq, Update, Green Locking, uPDH Box Checkup 
I had pulled out both X and Y servo boxes for inspection, put the Y box back, soldered in a missing op amp power capacitor on the X end box, and had
not yet put back the X end box yet because of the saturation issue I was looking into. Otherwise nothing was changed at the ends; I didn't open the tables
at all, or touch laser/SHG settings, just unplugged the servo boxes. 
    Reply  Tue Sep 2 20:02:06 2014, ericq, Update, Green Locking, uPDH Box Checkup 
I narrowed down the saturation point in the X green PDH box to the preamp inside the AD8336, but there is still no clear answer as to why it's happening. 
As per Jenne's request, I put the X end PDH box back for tonight's work. It locks, but we have an artificially low actuation range. With SR785,
I confirmed a PDH UGF around 5k. Higher than that, and I couldn't reliably measure the UGF due to SR560 saturations. The analyzer is not currently in the
    Reply  Wed Sep 3 00:17:22 2014, rana, Update, Green Locking, uPDH Box Checkup 
What monitor point is being plotted here? Or is it a scope probe output?
If this saturation is in the uPDH-X but not in the uPDH-Y, then just replace the VGA chip. Because these things have fixed attenuation inside,
they often can't go the rails even when the chip is new.
    Reply  Wed Sep 3 20:38:40 2014, ericq, Update, Green Locking, uPDH Box Checkup 
The traces were from the front panel output BNCs, but the VGA preamp exhibited this asymmetric saturation at its output.  
In any case, I tried to replace the Xend box's AD8336 with a new one, and in doing so, did some irreparable damage to the traces on the board  I was not able to get a new AD8336 into the board. There are some ATF ELOGs
Entry  Fri Aug 22 18:00:08 2014, jamie, Omnistructure, CDS, ubuntu12 awgstream installed 
I installed awgstream-2.16.14 in /ligo/apps/ubuntu12.  As with all the ubuntu12 "packages", you need to source the ubuntu12 ligoapps environment
script:

controls@pianosa|~ > . /ligo/apps/ubuntu12/ligoapps-user-env.sh
controls@pianosa|~ > which awgstream
/ligo/apps/ubuntu12/awgstream-2.16.14/bin/awgstream
controls@pianosa|~
Entry  Thu Jul 10 17:33:26 2014, jamie, Omnistructure, Computer Scripts / Programs, ubuntu12 software installed, gds 2.16.3.2 
Rana wanted the latest GDS installed (for newest DTT), so I made an ubuntu 12 install directory into which I installed

    gds-2.16.3.2
    root_v5.34.03

I installed this stuff in
/ligo/apps/ubuntu12
Entry  Fri May 16 20:55:18 2014, Jamie, Frogs, lore, un-full-screening Ubuntu windows with F11 
Last week Rana and I struggled to figure out how to un-full-screen windows on the Ubuntu workstations that appeared to be stuck in some sort of full
screen mode such that the "Titlebar" was not on the screen.  Nothing seemed to work.  We were in despair.
Well, there is now hope: it appears that this really is a "fullscreen" mode that can be activated by hitting F11.  
    Reply  Sun Apr 26 01:10:18 2015, rana, Update, ASC, unBroken Xass? xasstune_150426.pngxassnoise.pdf
Today I tried some things, but basically, lowering the input gain by 10 made the thing stable. In the attached screenshotstrip, you can see what happens
with the gain at 1. After a few cycles of oscillation, I turned the gain back to 0.1.

There still is an uncontrolled DoF, but I that's just the way it is since we only have one mirror (the BS) to steer into the x arm once the
    Reply  Sun Apr 26 15:05:35 2015, Jenne, Update, ASC, unBroken Xass? 
Thank you both.

I have updated the .snap file, so that it'll use these parameters, as Rana left them.  Also, so that the "unfreeze" script
works without changes (since it wants to make the overall gain 1), I have changed the Xarm input matrix elements from 1 to 0.1, for all of them. 
    Reply  Thu Apr 26 09:22:17 2012, steve, Update, , under the east end optical table 


    
        
            Quote:
        
        
            
            I added an U channel based bottom shelf at the south end today.
Entry  Wed Feb 15 11:34:01 2012, steve, Update, , under the shouth end optical table P1080535.JPGP1080537.JPG
I added an U channel based bottom shelf at the south end today.
Entry  Fri Jun 5 01:10:13 2009, rob, pete, Update, Locking, undermined 
We were stymied early in the evening by a surreptitiously placed, verbo-visually obfuscated command in the drstep script. 
    Reply  Tue Aug 8 17:04:26 2017, Steve, Update, VAC, unintended pump down pumping_down.png
IFO pressure 2 Torr,    PSL  shutter closed.  I'm pumping down with 2 roughing pumps with ion pump gate valves open and annulosses
at atm.

The vacuum envelope was vented to 17 Torr while I was replacing the USP battery stack. More about this later.....
    Reply  Tue Aug 8 17:44:11 2017, Steve, Update, VAC, unintended pump down stopped_pumping.png
Pumpdown stopped for over night  at ~  1 Torr

The roughing line disconnected.  Valves condition indicator  "moving " means that it is closed and it's cable disconnected
so it can not move.
    Reply  Wed Aug 9 11:59:51 2017, Steve, Update, VAC, unintended pump down at vacuum normal pdc.pngpd80b@vacnormal.png
pd80b has reached Vac Normal. IFO pressure 0.5 mTorr

We need our vauum channels back in dataviewer.




Entry  Sat Jul 18 16:59:01 2015, jamie, Update, CDS, unloaded, turned off loading of, symmetricom kernel module on fb 
fb has been loading a 'symmetricom' kernel module, presumably because it was once being used to help with timing.  It's no longer needed,
so I unloaded it and commented out the lines that loaded it in /etc/conf.d/local.start.
Entry  Thu May 14 02:36:05 2009, pete, Update, Locking, unstable IFO mc3.jpg
It seems that the MC3 problem is intermittent (one-day trend attached).  I tried to take advantage of a "clean MC3" night, but the watch
script would usually fail at the transition to DC CARM and DARM.  It got past this twice and then failed later, during powering up.   I
need to check the handoff.
    Reply  Wed Jul 24 12:24:43 2019, Milind, Update, IOO, unstick.py and ifotest 
Moved the unstick.py code to the ifotest repository here. It now
handles signals like those generated by Ctrl-C and so forth. It can still be run as python
unstick.py <machine1> <machine2> etc.
Entry  Thu Aug 27 12:34:48 2009, Yoichi, Update, Locking, up to arm power 70 
Last night, I tried to run locking scripts.
The power went up to 70 a couple of times .
Then it failed to switch to RF CARM.
Entry  Sun Jul 31 17:28:38 2016, rana, Omnistructure, General, upclean 
I cleaned up the south Electronics bench today.

The other two, as well as several of the desks are in some chaotic state of degradation. Please clean up your areas and put away projects which do not need to remain staged for several months. Try to eliminate "that's
Entry  Thu Feb 16 04:29:30 2012, kiwamu, Update, LSC, upconversion noise from BS motion Untitled.png
Sometimes ago I reported that there have been a kind of upconversion noise when PRM was excited (#6211).
This time I found another one, which showed up when BS was excited.
Assuming this is related to some kind of scattering process and also assuming this is from the same scattering
Entry  Fri Sep 10 02:35:30 2010, rana, kiwamu, valera, tara, Configuration, PSL, update 40mPSL.pdf
Over the last couple nights we got the beam into the FSS path and all the way to the IMC and out onto the AP table.
Tara and Valera have calculated a mode-matching solution for the reference cavity. It utilizes only a single lens between the AOM and the reference
cavity. Valera and Steve will move the reference cavity into place in the morning.
    Reply  Wed Sep 8 11:46:53 2010, kiwamu, Update, PSL, update of the layout 40mPSL.png
I put some green stuff on the layout drawing.
I continue to refine the positions of these stuff.
 
    Reply  Wed Feb 22 01:53:57 2012, kiwamu, Update, LSC, update on glitch table 
I tried SRMI. The glitch rate wasn't as high as that of PRMI but it happened once per 10 sec or so.
 

    
        
            
Entry  Thu Mar 8 04:13:12 2012, kiwamu, Update, LSC, update on the locking activity 
[Keiko / Kiwamu]
 Some updates on the locking activity:

    Started summarizing the data of the Michelson lock in a wiki page:
    
        https://wiki-40m.ligo.caltech.edu/Interferometer_Characterization/Michelson_Noise_Budget
    Reply  Fri Mar 9 13:34:13 2012, keiko, Update, LSC, update on the locking activity 
We tried to measure the sensing matrix for MICH and PRCL last night. They look too much mixed as we expect... the matrix may be posted later. We suspect
the IX and IY of the MICH excitation is not balanced very well, although Kiwamu adjusted that about two weeks ago, and it is mixing the dof. We'll try
to balance it again, ans see the matrix. 
    Reply  Sat Mar 10 02:00:03 2012, keiko, Update, LSC, update on the locking activity 
ITMX and ITMY balance for the MICH excitation (lockin) is adjusted again. Now it's ITMx = -0.992, ITMy = 1 for MICH (lockin output matrix values).
RA: what were the old values? Does this change make any difference for the signal mixing noticed before?
    Reply  Tue Jul 20 23:52:36 2010, kiwamu, Update, VAC, update: slow vent has started untitled.png
The vent is still going on. At this moment the pressure inside of the chambers is about 630 Torr.
Koji and I have replaced the 2nd instrument grade compressed air cylinder by the 3rd cylinder around 9 pm.
So far the vent speed has been nicely kept at about 1 Torr / min.
Entry  Fri May 2 01:58:52 2014, rana, Configuration, Computer Scripts / Programs, updateDB configured to index NFS during CRON daily 
I wanted to use locate to find some files today, but found that it
doesn't index any of our NFS mounted files (i.e. the whole /cvs/cds/ and /opt/rtcds/ ).
So I went into /etc/updatedb.conf and edited it like so, so that it no longer ignores NFS type file systems:
Entry  Wed Apr 3 01:32:04 2013, Jenne, Update, Computers, updated EPICS database (channels selected for saving) 
I modified /opt/rtcds/caltech/c1/chans/daq/C0EDCU.ini to include the C1:LSC-DegreeOfFreedom_TRIG_MON channels.  These are the same
channel that cause the LSC screen trigger indicators to light up. 
I vaguely followed Koji's directions in elog 5991, although I didn't add new grecords,
    Reply  Wed Apr 3 14:45:34 2013, Jamie, Update, Computers, updated EPICS database (channels selected for saving) 


    
        
            Quote:
        
        
            

           I modified /opt/rtcds/caltech/c1/chans/daq/C0EDCU.ini to include the C1:LSC-DegreeOfFreedom_TRIG_MON channels.  These are
Entry  Tue May 12 17:51:25 2020, rana, Summary, Computer Scripts / Programs, updated LESS syntax highlight on nodus 
apt install source-highlight

then modified bashrc to point to /usr/share instead of /usr/bin
Entry  Wed Mar 20 14:44:47 2013, Jamie, Update, Optics, updated calculations of PRC/SRC g-factors and ARM mode matching 
Below are new alamode calculations of the PRC and SRC g-factors and arm mode matchings.  These include fixes to the ABCD matrices for the flipped
folding mirrors that properly (hopefully) take into account the focusing effect of passing through the optic substrates.
I've used nominal curvatures of -600 m for the G&H PR2/SR2 optics, and -700 m for the Laseroptik PR3/SR3 dichroics.
ELOG V3.1.3-