40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 339 of 344  Not logged in ELOG logo
ID Datedown Author Type Category Subject Text Attachments
  286   Wed Jan 30 13:09:55 2008 AndreyUpdateSUSNew results for XARM (pdf)
See attachments: pdf-presentation with plots
in "true" axes Q_ETMX and Q_ITMX, and seismic
 New_Results_XARM.pdfAccel-Seismic_10AM.pdf 
  285   Wed Jan 30 11:49:30 2008 AlbertoSummaryElectronicsRF monitor's filters final schematics and transfer functionsThese are the final schematics for the 6th
order Chebyshev filters of the RF monitor
board. I'm also attaching the TF as I measured.
 8x 
  284   Tue Jan 29 14:56:39 2008 robUpdateDMFseisBLRMS 1.0
The [COLOR=red]seisBLRMS[/COLOR] 1.0 program
crashed at ~7:20 pm last night, so we didn't
  
  283   Mon Jan 28 19:35:55 2008 ranaSummaryPEMAccelerometer and Seismometer Coherences[FONT=Arial][COLOR=purple]The attached PDF
shows that there is some strange behavior
at low frequencies.[/COLOR][/FONT]
 Acc.pdf 
  282   Mon Jan 28 18:56:47 2008 ranaUpdateDMFseisBLRMS 1.0[B]I made all of the updates I aludded to
before:[/B]
  
  281   Mon Jan 28 17:16:54 2008 AndreyConfigurationComputersMatlab libraries DO NOT WORK properly sometimes
Working in Matlab, I encountered at two different
times today the license distribution problem:
  
  280   Mon Jan 28 15:11:38 2008 robHowToDMFrunning compiled matlab DMF tools
I compiled Rana's seisBLRMS monitor, and
it's now running on mafalda.  To start your
  
  279   Mon Jan 28 12:42:48 2008 DmassBureaucracyTMICoffeeThere is tea in the coffee carafe @ the 40m.
It is sitting as though it were fresh coffee.
There is also nothing on the post it.
  
  278   Sun Jan 27 21:44:48 2008 ranaUpdateCDSSeismic BLRMS on MatlabI wrote a matlab script to produce band limited
RMS trends from our accelerometers. It mimics
the code written
 seisBLRMS.m 
  277   Sun Jan 27 13:13:21 2008 tobinMetaphysicsGeneraldepartureIt's been grand.  Thanks for having me!

GWAVES IN '08!
  
  276   Sat Jan 26 22:00:03 2008 JohnUpdateGeneralLSC-TRY_OUT and ETMY-QPDIn the path from the ETM to the trans PD and
QPD at the Y end I have replaced a BS1-1064-10-2037-45P
with a polariser. The power falling on these
  
  275   Sat Jan 26 18:48:43 2008 JohnSummaryComputersRestart iscepicsiscepics died this afternoon. We restarted
it and restored settings from yesterday.
I've written up instructions in the wiki.
  
  274   Sat Jan 26 18:12:45 2008 ranaHowToComputersextra processes and crashesThere were a load of extra processes on op440m;
they were all related to rogue DV processes
(frameMemRead, framer4, xmgrace, etc.)
  
  273   Sat Jan 26 02:34:34 2008 AndreyUpdateComputer Scripts / ProgramsOvernight Measuremts in XARM
I am running the program for measuring RMS
of peaks in XARM tonight. I just started
  
  272   Sat Jan 26 02:08:53 2008 JohnOmnistructureLSCFibresThere is now a fibre running from the SP table
to the ISCT at the Y-end. In the coming days
I will try to mode match the beam from this
  
  271   Sat Jan 26 02:02:43 2008 JohnSummaryGeneralNew ChannelsI added the following channels.

# C1ASC_QPDs
  
  270   Fri Jan 25 21:36:40 2008 ranaUpdateCDSmDV / channel issues[COLOR=orange]Fri Jan 25 21:30:00 2008[/COLOR]

  
  269   Fri Jan 25 17:11:07 2008 Max , AndreyConfigurationGeneralNEW_FETCH_SHOUROV and GET_DATA do not work
The problem which started yesterday after
Andrey's framebuilder restart still persists.
  
  268   Fri Jan 25 15:53:59 2008 AlbertoUpdateElectronics40 dB from the 3rd order ChebyschevI managed to tune the 7 knobs in the 3rd order
Chebyshev bandpass filter obtaining the tranfer
function attached to this entry. We have
 166MhzElog.png 
  267   Fri Jan 25 13:36:13 2008 josephbConfigurationCamerasWorking GiGE video on MafaldaFinally got the GiGE camera sample viewer
video running on Mafalda by updating to the
latest API (version 1.16 from Dec 16, 2007)
  
  266   Fri Jan 25 11:38:16 2008 josephbConfigurationCamerasWorking GiGE video on Linux - sort of1)I have been able to compile the SampleViewer
program which can stream the video from the
Prosilica 750C camera.  This was accomplished
 snap.tiff 
  265   Fri Jan 25 10:14:35 2008 robConfigurationSUSChanges to Dataviewer channels (XARM)[quote]
2) [COLOR=red]BAD NEWS.[/COLOR] While "clicking
the appropriate blue button" on the DAQ MEDM
  
  264   Fri Jan 25 09:22:21 2008 steveUpdatePEMburned toast award goes toDYM for  collaborating with the enemy. 

In order to minimize the number of ants visiting
  
  263   Fri Jan 25 08:55:26 2008 robConfigurationGeneralChanges to Dataviewer channels (XARM)
As a general rule,
  
  262   Thu Jan 24 22:52:18 2008 AndreyBureaucracyGeneralAnts around a dirty glass (David - please read!)
Dear coleagues,
  
  261   Thu Jan 24 22:10:49 2008 AndreyConfigurationComputer Scripts / ProgramsProblem with channels - help of Rana, Robert or Steve is needed
I definitely spoiled something (changes some
settings) by chaotically clicking those blue
  
  260   Thu Jan 24 20:03:40 2008 AndreyConfigurationSUSChanges to Dataviewer channels (XARM)
1) [COLOR=blue]Good news.[/COLOR] I added
a chanel "C1:SUS-ETMX_POS" to Dataviewer.
  
  259   Thu Jan 24 12:50:50 2008 JohnSummaryTreasureSugar NapoleonsSome pictures from the group meeting yesterday.  Sweeties.pdf 
  258   Thu Jan 24 11:52:56 2008 steveUpdatePEMthe mud is cleaned up & MOPA shutter is openedSafety glasses are required again!

I have just opened the mopa shutter.
  
  257   Wed Jan 23 20:52:40 2008 ranaSummaryEnvironmentFlooding from construction areaWe noticed tonight around 7 PM that [B]there
was a lot of brown water in the control room
and also in the interferometer area[/B] mostly
 Shop-Vac_Action.MOVFlooding.pdf 
  256   Wed Jan 23 12:31:36 2008 AndreySummarySUSDissapointing Results of XARM optimization (PDF-file)
I attach a PDF-file which summarizes briefly
the results of measurements/calculations
 Sad_Results_XARM.pdf 
  255   Wed Jan 23 11:41:06 2008 steveUpdatePEMsulfur smell in 40mLed - acid car batteries were overcharged
in the machine shop next door
and sulfuric acid smell is coming over to
  
  254   Wed Jan 23 09:27:55 2008 steveUpdate etmy sus damping restoredSeismis event trips etmy  etmysus.jpg 
  253   Tue Jan 22 13:11:03 2008 tobinUpdateASCETMY oplev recenteredThe light wasn't even on the diode.   
  252   Tue Jan 22 02:33:45 2008 robUpdateLSCDRMI work
0) The ETMY oplev needs work/centering
  
  251   Mon Jan 21 23:30:03 2008 AndreyUpdateComputer Scripts / ProgramsMatlab Program for Q-factor measurements (XARM -> ITMX and ETMX)
Finally I overcame difficulties with adapting
Sonia's Matlab programs for XARM (Sonia's
 Example-ITMX_POS_40.png 
  250   Fri Jan 18 20:53:56 2008 tobinConfigurationGeneralETMY oplevI monkeyed around with the ETMY oplev, adding
a folding mirror and moving the HeNe so that
John, Sam, and I have more room for our auxiliary
  
  249   Fri Jan 18 15:31:47 2008 robUpdateLSCThursday's locking
[I]rob, johnnie, andrey[/I]
 DARMnoise080118.png 
  248   Fri Jan 18 11:53:50 2008 AlbertoUpdateElectronicsRF Monitor Band-pass FilterThe response is asymmetric and on the left
side of the peak, we have at least 33dB within
33Mhz, which is enough for all the frequencies.
 Chebyshevb.png 
  247   Thu Jan 17 20:50:55 2008 tobinUpdateGeneralfiber couplingSam, John, and I matched the beam from an
NPRO into a fiber on the SP table today.
 In doing so we used our GigE camera for
  
  246   Thu Jan 17 18:22:14 2008 AlbertoUpdateElectronicsRF Monitor Band-pass FilterAfter we finalized the schematic for the RF
monitor board based on buffered LC resonators,
on Richard Abbott's suggestion to avoid the
 RF166Mhz.pngChebyshevb.pngChebyshev2b.png 
  245   Thu Jan 17 15:11:13 2008 josephbUpdateCamerasWorking on Malfalda1) I can statically compile the ListCamera
code (which basically just goes out and finds
what cameras are connected to the network)
  
  244   Thu Jan 17 14:13:20 2008 robUpdateLSCWednesday's lockingIncremental progress on locking yet again.
 This time the handoff of DARM to the OMC
worked, and progress halted at handing off
  
  243   Wed Jan 16 19:57:49 2008 tobinConfigurationPhotosISCT_EXHere's a photo of the ISCT_EX table, for the
purpose of planning our auxiliary laser arm
locking scheme.   Note the (undumped!) beam
 trx-annotated-small.jpg 
  242   Wed Jan 16 18:24:41 2008 ranaUpdateSUSETMY WatchdogBecause [COLOR=purple][B]Steve keeps complaining
about ETMY[/B][/COLOR], I looked at some
minute trend to see if there was something
 A.pdf 
  241   Wed Jan 16 14:09:45 2008 robUpdateLSCtuesday's locking
I got a little further with the locking (PRFPMI)
last night, after discovering that the cable
  
  240   Wed Jan 16 14:06:24 2008 robUpdateLSCmonday's lockingrob, tobin, johnnie

We did some locking work monday night, with
  
  239   Tue Jan 15 13:15:27 2008 tobinUpdateEnvironmentlots of noiseThey're throwing concrete around at the construction
site.
  
  238   Mon Jan 14 23:11:26 2008 tobinConfigurationGeneralfiberJohn and I removed the fiber that ran from
the SP table to the cleanroom.  We plan to
build a MZ interferometer with this fiber
  
  237   Mon Jan 14 14:41:09 2008 steveUpdateSUSetmy sus damping restored & mz relockedTree days trend of MZ HV drift is typical
these days.
So as the etmy sus inability to hold damping
 etmysus&mzhvtrend.jpg 
ELOG V3.1.3-